HySecurity StrongArmPark DC Gear Oil Operating instructions

Type
Operating instructions
Page 1
www.hysecurity.com © 2014 P/N MX3661 D0637 Rev A
Installation Instructions
MX3661
StrongArmPark DC Gear Oil Replace
ment
Tools Required
Utility knife
7/32-inch and 6 mm hex keys
Paper towels or clean rags to clean up oil spills
Kit Contents
16 oz waste container
16 oz replacement gear oil bottle
Yorker spout
Bulb extractor
Remove Fill Hole Cap
1. Remove the front access panel and turn o the AC and DC power switches.
2. Use a 7/32-inch hex key to remove the StrongArmPark DC top cover.
3. Remove the ll hole cap using the 6 mm hex key. Set the cap aside on a clean
rag or surface.
4. Remove all the gear oil from the gear box using the bulb extractor. Empty its
contents into the 16 oz waste container provided. e waste container should
be about half full when the majority of the oil from the gear box is extracted.
5. Cap the waste container and set the bulb extractor aside.
6. Cut the tip of the Yorker cap and screw it on the replacement gear oil bottle.
7. Rell the gear box with the gear oil.
Remove top cover
7/32-inch hex key
Drive Belt cover
Leave in place
ON/OFF power switches
(AC and DC)
Fill hole cap
(6 mm hex key)
Remove front
access panel
Drive belt cover
removed for clarity
of photo.
Gear box
Utility
knife
Yorker
cap
Bulb
extractor
Waste
container
Replacement
gear oil bottle
Page 2
www.hysecurity.com © 2014 P/N MX3661 D0637 Rev A
8. Replace the ll hole cap into the gear box.
9. Replace the top cover. Refer to the illustration on page 1.
10. Turn the AC and DC switches ON. is cycles the power which allows the
operator to search for the target magnet and “relearn” it limits.
NOTE: Be aware that the arm will cycle open, and then close, as it relearns its
limits. If you don’t cycle the power, the operator will not “relearn” its limits and
will not operate properly.
Technical Support
For technical support, call your installer or authorized HySecurity distributor.
Obtain the serial number of your operator before calling. For the name of a
distributor near you, call HySecurity at 800-321-9947.