FUJITSU Server PRIMERGY CX2550 M6 /
CX2560 M6 Server Node
Upgrade and Maintenance Manual
Upgrade and Maintenance Manual - English
09/2021
Comments… Suggestions… Corrections…
The User Documentation Department would like to know your opinion of this manual. Your
feedback helps us optimize our documentation to suit your individual needs.
Feel free to send us your comments by e-mail to [email protected].
Documentation creation according to DIN EN ISO 9001:2015
To ensure a consistently high quality standard and user-friendliness, this documentation was
created to meet the regulations of a quality management system which complies with the
requirements of the standard DIN EN ISO 9001:2015.
cognitas. Gesellschaft für Technik-Dokumentation mbH www.cognitas.de
Copyright and Trademarks
Copyright 2021 FUJITSU LIMITED
All rights reserved.
Delivery subject to availability; right of technical modifications reserved.
All hardware and software names used are trademarks of their respective manufacturers.
–The contents of this manual may be revised without prior notice.
–Fujitsu assumes no liability for damages to third party copyrights or other rights arising from
the use of any information in this manual.
–No part of this manual may be reproduced in any form without the prior written permission
of Fujitsu.
Microsoft, Windows, Windows Server, and Hyper-V are trademarks or registered trademarks of
Microsoft Corporation in the USA and other countries.
Intel and Xeon are trademarks or registered trademarks of Intel Corporation or its subsidiaries
in the USA and other countries.
Before reading this manual
For your safety
This manual contains important information for safely and correctly using this
product.
Carefully read the manual before using this product. Pay particular attention to
the accompanying manual "Safety Notes and Regulations" and ensure that
these safety notes are understood before using the product. Keep this manual
and the "Safety Notes and Regulations" manual in a safe place for easy
reference while using this product.
Radio interference
This product is a "Class A" ITE (Information Technology Equipment). In a
domestic environment this product may cause radio interference, in which case
the user may be required to take appropriate measures.
VCCI-A
Aluminum electrolytic capacitors
The aluminum electrolytic capacitors used in the printed circuit board
assemblies of the product and in the mouse and keyboard are limited-life
components. Use of these components beyond their operating life may result
in electrolyte leakage or depletion, potentially causing emission of foul odor or
smoke.
As a guideline, in a normal office environment (25 °C) operating life is not
expected to be reached within the maintenance support period (5 years).
However, operating life may be reached more quickly if, for example, the
product is used in a hot environment. The customer shall bear the cost of
replacing replaceable components which have exceeded their operating life.
Note that these are only guidelines, and do not constitute a guarantee of
trouble-free operation during the maintenance support period.
High safety use
This product has been designed and manufactured to be used in commercial
and/or industrial areas as a server.
Upgrade and Maintenance Manual
The product is not suitable for use at visual display workplaces according to §2
of the Workplace Regulations (applies to all server systems except TX server
systems).
When used as visual display workplace, it must not be placed in the direct field
of view to avoid incommoding reflections (applies only to TX server systems).
The device has not been designed or manufactured for uses which demand an
extremely high level of safety and carry a direct and serious risk of life or body
if such safety cannot be assured.
These uses include control of nuclear reactions in nuclear power plants,
automatic airplane flight control, air traffic control, traffic control in mass
transport systems, medical devices for life support, and missile guidance
control in weapons systems (hereafter, "high safety use"). Customers should
not use this product for high safety use unless measures are in place for
ensuring the level of safety demanded of such use. Please consult the sales
staff of Fujitsu if intending to use this product for high safety use.
Measures against momentary voltage drop
This product may be affected by a momentary voltage drop in the power supply
caused by lightning. To prevent a momentary voltage drop, the use of an
uninterruptible power supply is recommended.
(This notice follows the guidelines of Voltage Dip Immunity of Personal
Computer issued by JEITA, the Japan Electronics and Information Technology
Industries Association.)
Technology controlled by the Foreign Exchange and Foreign Trade
Control Law of Japan
Documents produced by Fujitsu may contain technology controlled by the
Foreign Exchange and Foreign Trade Control Law of Japan. Documents which
contain such technology should not be exported from Japan or transferred to
non-residents of Japan without first obtaining authorization in accordance with
the above law.
Harmonic Current Standards
This product conforms to harmonic current standard JIS C 61000-3-2.
Upgrade and Maintenance Manual
Only for Japan: About SATA HDDs
The SATA version of this server supports HDDs with SATA/BC-SATA storage
interfaces. Please note that the usage and operation conditions differ
depending on the type of HDD used.
For more information on the usage and operation conditions of each available
type of HDD, see the following internet address:
https://jp.fujitsu.com/platform/server/primergy/harddisk/
Only for Japan:
Shielded LAN cables should be used in this product.
UK Importer information
Fujitsu Services Limited
22 Baker Street, London, W1U 3BW, United Kingdom
Upgrade and Maintenance Manual
Version history
Issue
number
Issue date Description
V 1.0 11/2020 Early release
V 1.1 06/2021 Update early release
V 2.0 09/2021 General release
Upgrade and Maintenance Manual
Content
1 Introduction 15
1.1 Concept and target groups of this manual 15
1.2 Notational conventions 15
2 Before you start 17
2.1 Basic information 17
2.1.1 Proceeding 17
2.1.2 Advanced Thermal Design (ATD) 17
2.1.3 Installing optional components 18
2.2 Classification of procedures 18
2.2.1 Assignment of unit categories 18
2.2.2 Customer Replaceable Units (CRU) 19
2.2.3 Upgrade and Repair Units (URU) 19
2.2.4 Field Replaceable Units (FRU) 21
2.3 Average task duration 22
2.4 Tools you need at hand 23
2.5 Documentation overview 23
2.5.1 Downloading manuals 23
2.5.2 List of documents 24
2.5.3 Further documents 26
3 Important information 27
3.1 Introduction 27
3.2 Safety instructions 27
3.2.1 Basic safety instructions 27
3.2.2 Before starting up 28
Upgrade and Maintenance Manual
3.2.3 Installation and operation 28
3.2.4 Batteries 31
3.2.5 Working with optical disk drives (ODDs) and media 31
3.2.6 Laser information 33
3.2.7 Modules with Electrostatic-Sensitive Devices (ESD modules) 33
3.2.8 Transporting the server 35
3.2.9 Installing the server enclosure in the rack 36
3.3 CE conformity 36
3.4 ENERGY STAR 37
3.5 FCC Class A Compliance Statement 37
3.6 Other important information 38
3.7 Environmental protection 39
4 Basic hardware procedures 41
4.1 Using diagnostic information 41
4.1.1 Proceeding 41
4.1.2 Locating the defective server 41
4.1.3 Determining the error class 42
4.1.4 Locating the defective component 42
4.2 Shutting down the server node 45
4.3 Removing server nodes from the server enclosure 45
4.4 Handling riser modules 49
4.4.1 Positions of riser modules 49
4.4.2 Removing a riser module 49
4.4.3 Installing a riser module 51
4.5 Handling dummy riser modules 52
4.6 Handling the memory slot air ducts 53
4.7 Installing the CX2550 M6 or CX2560 M6 server node 57
Content
Upgrade and Maintenance Manual
4.8 Switching on the server node 59
5 Basic software procedures 61
5.1 Starting the maintenance task 61
5.1.1 Suspending BitLocker functionality 61
5.1.2 Disabling the boot watchdog 62
5.1.3 Removing backup and optical disk media 63
5.1.4 Verifying and configuring the backup software solution 64
5.1.5 Configuring LAN teaming 64
5.1.6 Switching on the ID indicator 66
5.2 Completing the maintenance task 67
5.2.1 Updating or recovering the BIOS and iRMC S5 67
5.2.2 Verifying system information backup or restore 69
5.2.3 Updating expansion card firmware 70
5.2.4 Resetting the boot retry counter 71
5.2.5 Enabling the boot watchdog 73
5.2.6 Enabling replaced components in the BIOS 74
5.2.7 Reconfiguring the backup software solution 75
5.2.8 Verifying the memory mode 76
5.2.9 Verifying the system time settings 76
5.2.10 Viewing and clearing the System Event Log (SEL) 77
5.2.11 Updating the NIC configuration file in a Linux and VMware
environment 80
5.2.12 Resuming BitLocker functionality 81
5.2.13 Performing a RAID array rebuild 82
5.2.14 Looking for MAC/WWN/GUID and SAS addresses 83
5.2.14.1 Basic information 83
5.2.14.2 Looking for the MAC address of a LAN controller 83
5.2.14.3 Looking for the WWN address of a fibre channel controller 84
5.2.14.4 Looking for the GUID address of an infiniband or Omni-Path
controller 85
5.2.14.5 Looking for SAS addresses of SAS controllers for external
devices 85
5.2.15 Using the Chassis ID Prom Tool 86
5.2.16 Configuring LAN teaming 87
5.2.17 Switching off the ID indicator 88
Content
Upgrade and Maintenance Manual
5.2.18 Performing a fan test 89
6 Expansion cards and OCP mezzanine cards 91
6.1 Safety notes 91
6.2 Basic information 91
6.2.1 CX2550 M6 91
6.2.2 CX2560 M6 93
6.3 Handling slot brackets 96
6.3.1 Installing slot brackets 96
6.3.2 Removing slot brackets 98
6.4 OCP (Open Compute Project) modules 98
6.4.1 Installing the OCP module 98
6.4.2 Removing the OCP module 101
6.4.3 Replacing the OCP module 104
6.5 Handling SFP+ transceiver modules 105
6.5.1 Installing SFP+ transceiver modules 105
6.5.2 Removing SFP+ transceiver modules 111
6.6 Expansion cards in riser modules 115
6.6.1 Installing expansion cards 115
6.6.2 Removing expansion cards 118
6.6.3 Replacing an expansion card 120
6.7 Replacing a dedicated internal RAID module 123
6.8 Flash backup unit (FBU) 129
6.8.1 Safety notes 129
6.8.2 Basic information 129
6.8.3 Installing the FBU 131
6.8.4 Removing an FBU 140
6.8.5 Replacing an FBU 144
6.8.6 Replacing a TFM 145
Content
Upgrade and Maintenance Manual
7 Main memory 151
7.1 Safety notes 151
7.2 Basic information 152
7.2.1 Slots and features 152
7.2.2 Memory population conditions 153
7.2.3 Modes of operation 155
7.2.3.1 DDR4 DIMM 155
7.2.3.2 DDR4 DIMM and Optane PMem module (only for CX2560
M6) 159
7.3 Installing memory modules 163
7.4 Removing memory modules 166
7.5 Replacing memory modules 168
8 Processor (CPU) 171
8.1 Safety notes 171
8.2 Basic information 171
8.3 Replacing a CPU or heat sink 172
9 Liquid cooling (LC) 187
9.1 Safety notes 187
9.2 Basic information 187
9.3 Replacing the CPU or LC kit 192
9.4 Main memory for LC 209
9.4.1 Installing memory modules 209
9.4.2 Removing memory modules 213
9.4.3 Replacing memory modules 216
Content
Upgrade and Maintenance Manual
10 System board and components 219
10.1 Safety notes 219
10.2 Basic information 219
10.3 CMOS battery (CR2450) 220
10.3.1 Replacing the CMOS battery (CR2450) 220
10.4 Trusted Platform Module (TPM) 223
10.4.1 Position of the TPM 223
10.4.2 Installing the TPM 223
10.4.3 Removing the TPM 227
10.4.4 Replacing the TPM 231
10.5 iRMC microSD card 234
10.5.1 Installing the iRMC microSD card 234
10.5.2 Removing the iRMC microSD card 236
10.5.3 Replacing the iRMC microSD card 237
10.6 M.2 SSD 238
10.6.1 Slots and bolts for M.2 SSDs 238
10.6.2 Installing an M.2 SSD 240
10.6.3 Removing an M.2 SSD 243
10.6.4 Replacing an M.2 SSD 245
10.7 Dual microSD 64GB Enterprise 247
10.7.1 Position of the Dual microSD 64GB Enterprise 247
10.7.2 Installing the Dual microSD 64GB Enterprise 247
10.7.3 Removing the Dual microSD 64GB Enterprise 251
10.7.4 Replacing the Dual microSD 64GB Enterprise 252
10.7.5 Replacing the microSD card 255
10.8 System board 256
10.8.1 Replacing the system board 256
11 Cabling 265
11.1 Safety notes 265
Content
Upgrade and Maintenance Manual
11.2 Cabling information 265
12 Appendix 297
12.1 Mechanical overview 297
12.1.1 Server node interior 297
12.1.2 Server node rear 299
12.2 Connectors, controls, and indicators 300
12.2.1 System board connectors 300
12.2.2 Connectors on the server node 302
12.2.3 Controls on the server node 303
12.2.4 Power, ID, CSS and Global Error indicators 304
12.2.5 LAN indicators 306
12.3 Onboard settings 308
12.4 Minimum startup configuration 309
Content
Upgrade and Maintenance Manual
Content
Upgrade and Maintenance Manual
1 Introduction
1.1 Concept and target groups of this manual
This upgrade and maintenance manual provides instructions for the following
procedures:
–Upgrading the server configuration by adding optional hardware
components.
–Upgrading the server configuration by replacing existing hardware
components with superior ones.
–Replacing defective hardware components.
This manual focuses on on-site maintenance tasks. It is recommended to
prepare each service assignment following remote diagnostics procedures, as
described in the "ServerView Suite Local Service Concept (LSC)" manual, see
"Documentation overview" on page 23.
CAUTION
The document at hand comprises procedures of a wide range of
complexity.
â–¶Check the profile of qualification for technicians before assigning
tasks.
â–¶Before you start, carefully read "Classification of procedures" on
page 18.
1.2 Notational conventions
The following notational conventions are used in this manual:
Text in bold Indicates references to names of interface
elements.
Text in monospace Indicates commands and text to be entered by
the user.
Upgrade and Maintenance Manual 15
"Quotation marks" Indicate names of chapters and terms that are
being emphasized.
â–¶ Describes activities that must be performed in
the order shown.
[Abc] Indicates keys on the keyboard.
CAUTION
Pay particular attention to texts marked with this
symbol. Failure to observe this warning may
endanger your life, destroy the system or lead
to the loss of data.
Indicates additional information, notes and tips.
Indicates the procedure category in terms of
complexity and qualification requirements, see
"Classification of procedures" on page 18.
Indicates the average task duration, see
"Average task duration" on page 22.
Introduction
16 Upgrade and Maintenance Manual
2 Before you start
2.1 Basic information
2.1.1 Proceeding
Before you start any upgrade or maintenance task, proceed as follows:
â–¶Carefully read the safety instructions, see "Important information" on
page 27.
â–¶Make sure that all necessary manuals are available, see "Documentation
overview" on page 23. Print the PDF files if required.
â–¶Make yourself familiar with the procedure categories, see "Classification of
procedures" on page 18.
â–¶Ensure that all required tools are available, see "Tools you need at hand" on
page 23.
2.1.2 Advanced Thermal Design (ATD)
The ATD option allows you to operate the system with a wider temperature
range either of 5 °C to 40 °C or 5 °C to 45 °C, depending on your system and
configuration.
This option can only be ordered from the
manufacturer and is indicated by the respective
logo on the identification rating plate.
CAUTION
â–¶In a system that is configured with ATD, only certain components
which support the respectively increased higher operating
temperature range may be installed and used. For applicable
restrictions, see the official configurator tool.
Upgrade and Maintenance Manual 17
2.1.3 Installing optional components
The operating manual of your server gives an introduction to server features
and provides an overview of available hardware options.
Use the Fujitsu ServerView Suite management software and the iRMC S5 web
interface to prepare hardware expansions. For more information about
ServerView Suite documentation, see "Documentation overview" on page 23.
Please see the following ServerView Suite topics:
–Operation
–Virtualization
–Maintenance
–Out-Of-Band Management
For the latest information on hardware options, see the hardware
configurator of your server, available online at the following address:
https://www.fujitsu.com/fts/products/computing/servers/primergy/
index.html
For Japan:
https://www.fujitsu.com/jp/products/computing/servers/primergy/
Please contact your local Fujitsu customer service partner for details on how to
order expansion kits or spare parts.
2.2 Classification of procedures
2.2.1 Assignment of unit categories
The complexity of maintenance procedures varies significantly. Procedures
have been assigned to one of three unit categories, indicating the level of
difficulty and required qualification.
At the beginning of each procedure, the involved unit category is indicated by
one of the symbols introduced in this section.
Before you start
18 Upgrade and Maintenance Manual
Please ask your local Fujitsu service center for more information.
2.2.2 Customer Replaceable Units (CRU)
Customer Replaceable Units (CRU)
Customer Replaceable Units are intended for customer self service and may
be installed or replaced as hot-plug components during operation.
Components that the customer is entitled to replace may differ
according to the service form in his country.
For Japan:
https://www.fujitsu.com/jp/products/computing/servers/primergy/support/
repair.html
Hot-plug components increase system availability and guarantee a high degree
of data integrity and fail-safe performance. Procedures can be carried out
without shutting down the server node or going offline.
Components that are handled as Customer Replaceable Units
–Hot-plug HDD/SSD modules
Peripherals that are handled as Customer Replaceable Units
–Mouse
–Keyboard
–Monitor
2.2.3 Upgrade and Repair Units (URU)
Upgrade and Repair Units (URU)
Before you start
Upgrade and Maintenance Manual 19
Upgrade and Repair Units are non hot-plug components that can be ordered
separately to be installed as options (Upgrade Units) or are available to the
customer through customer self service (Repair Units).
For Japan, customer allows only upgrade. For upgrade units as
customer replaceable, see:
https://www.fujitsu.com/jp/products/computing/servers/primergy/
Server management error messages and diagnostic indicators on the
front panel and system board will report defective Upgrade and Repair
Units as customer replaceable CSS components.
Upgrade and repair procedures involve shutting down the server node.
CAUTION
The device may be seriously damaged or cause damage if it is opened
without authorization or if repairs are attempted by unauthorized and
untrained personnel.
Components that are handled as Upgrade Units
–CPU (upgrade)
–Expansion card
–OCP module
–Flash backup units (FBU)
–Memory modules
–iRMC microSD card
–M.2 SSDs (M.2 SSDs with 80 mm and 100 mm length)
–Dual microSD 64GB Enterprise
–PCIe riser modules
CAUTION
Installing procedures involving Upgrade and Repair Units must be
performed exclusively by Fujitsu service personnel or technicians
trained by Fujitsu. Please note that unauthorized interference with the
system will void the warranty and exempt the manufacturer from all
liability.
Before you start
20 Upgrade and Maintenance Manual
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208
  • Page 209 209
  • Page 210 210
  • Page 211 211
  • Page 212 212
  • Page 213 213
  • Page 214 214
  • Page 215 215
  • Page 216 216
  • Page 217 217
  • Page 218 218
  • Page 219 219
  • Page 220 220
  • Page 221 221
  • Page 222 222
  • Page 223 223
  • Page 224 224
  • Page 225 225
  • Page 226 226
  • Page 227 227
  • Page 228 228
  • Page 229 229
  • Page 230 230
  • Page 231 231
  • Page 232 232
  • Page 233 233
  • Page 234 234
  • Page 235 235
  • Page 236 236
  • Page 237 237
  • Page 238 238
  • Page 239 239
  • Page 240 240
  • Page 241 241
  • Page 242 242
  • Page 243 243
  • Page 244 244
  • Page 245 245
  • Page 246 246
  • Page 247 247
  • Page 248 248
  • Page 249 249
  • Page 250 250
  • Page 251 251
  • Page 252 252
  • Page 253 253
  • Page 254 254
  • Page 255 255
  • Page 256 256
  • Page 257 257
  • Page 258 258
  • Page 259 259
  • Page 260 260
  • Page 261 261
  • Page 262 262
  • Page 263 263
  • Page 264 264
  • Page 265 265
  • Page 266 266
  • Page 267 267
  • Page 268 268
  • Page 269 269
  • Page 270 270
  • Page 271 271
  • Page 272 272
  • Page 273 273
  • Page 274 274
  • Page 275 275
  • Page 276 276
  • Page 277 277
  • Page 278 278
  • Page 279 279
  • Page 280 280
  • Page 281 281
  • Page 282 282
  • Page 283 283
  • Page 284 284
  • Page 285 285
  • Page 286 286
  • Page 287 287
  • Page 288 288
  • Page 289 289
  • Page 290 290
  • Page 291 291
  • Page 292 292
  • Page 293 293
  • Page 294 294
  • Page 295 295
  • Page 296 296
  • Page 297 297
  • Page 298 298
  • Page 299 299
  • Page 300 300
  • Page 301 301
  • Page 302 302
  • Page 303 303
  • Page 304 304
  • Page 305 305
  • Page 306 306
  • Page 307 307
  • Page 308 308
  • Page 309 309
  • Page 310 310

Fujitsu PRIMERGY CX2550 M6 User manual

Category
Servers
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI