RAB Lighting W17-30LY is a high-quality, affordable, easy-to-install LED wall pack light designed for energy efficiency. It's perfect for a variety of outdoor lighting applications, including commercial and industrial buildings, parking lots, and security lighting. With its universal voltage driver, the W17-30LY can operate at 120V through 277V, 50 or 60 Hz, making it suitable for use in a wide range of locations. It also features a durable tempered glass lens that is easy to clean and maintain.

RAB Lighting W17-30LY is a high-quality, affordable, easy-to-install LED wall pack light designed for energy efficiency. It's perfect for a variety of outdoor lighting applications, including commercial and industrial buildings, parking lots, and security lighting. With its universal voltage driver, the W17-30LY can operate at 120V through 277V, 50 or 60 Hz, making it suitable for use in a wide range of locations. It also features a durable tempered glass lens that is easy to clean and maintain.

INSTRUCTIONS
W17 WALL PACK INSTALLATION
RAB Lighting is committed to creating high-quality, aordable, well-designed and energy-ecient LED lighting and controls that make it easy for electricians to install
and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
RAB xtures must be wired in accordance with the National Electrical Code and all applicable local codes. Proper grounding is required
for safety. THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR
WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.
WARNING:
• Make certain power is OFF before installing or maintaining xture.
NOTE:
• No user maintenance or cleaning required.
Fixture should not be recessed, surface mount only.
1. Open Reector Door by loosening Reector Door Screw (1),
see Fig. 1.
2. Reector Dooreector Door will hinge downward and remain attached will hinge downward and remain attached
during installation as shown in during installation as shown in Fig 2Fig 2..
3. 3. Line up the Line up the Fixture Fixture to desired location. Use the to desired location. Use the Drill Template Drill Template
(Fig. 2)(Fig. 2) on the inside back surface of the on the inside back surface of the FixtureFixture to match to match
most standard junction boxes. most standard junction boxes. Secure the Secure the FixtureFixture in place with in place with
screws screws (supplied by others)(supplied by others)..
4. 4. Complete the wiring to the supply wires and ground Complete the wiring to the supply wires and ground (see wiring (see wiring
instructionsinstructions Fig. 3 Fig. 3))..
5. 5. Pivot the Pivot the ReectorReector DoorDoor back into place and push until it snaps back into place and push until it snaps
closed. Tighten closed. Tighten Reector Door ScrewReector Door Screw (1) to secure (1) to secure Reector
Door to Fixture.
6. Apply weatherproof silicone sealant around the edge of the wall
box. This is especially important with an uneven wall surface.
MOUNTING FIXTURE TO THE WALL
W1730L /36L W1755L/75L/90L W17150L
FIG. 1
FIG. 2
Fixture
Drill Plate
Reector
Door
Reector Door
Screw
Reector
Mounting Screws (4)
(supplied by others)
INSTRUCTIONS
W17 WALL PACK INSTALLATION
RAB Lighting is committed to creating high-quality, aordable, well-designed and energy-ecient LED lighting and controls that make it easy for electricians to install
and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: mark[email protected]
TROUBLESHOOTING
CLEANING & MAINTENANCE
1. Check that the line voltage at the xture is correct. Refer to
wiring directions.
2. Be sure the xture is grounded properly.
3. Is the photocell, if used, functioning properly?
CAUTION: Be sure xture temperature is cool enough to touch.
Do not clean or maintain while xture is energized.
1. Clean tempered glass lensglass lens with non-abrasive, glass cleaning
solution.
2. Do not open xture to clean the LEDs. Do not touch the LEDs.
3. No user maintenance or cleaning required.
ONOFF WIRING
Note: These instructions do not cover all details or variations in equipment nor do they provide for every possible situation during installation, operation or maintenance.
FIG. 3
Universal voltage driver permits operation at 120V thru 277V, 50 or
60 Hz, follow the wiring directions below.
1. Connect the black xture lead to the LINE supply lead.
2. Connect the white xture lead to the COMMON supply lead.
3. Connect the GROUND wire from xture to supply ground.
DIMENSIONAL DRAWINGS
W17-IN-0720
RAB WARRANTY: RAB’S warranty is subject to all terms and conditions found at rablighting.com/warranty.
73695-RAB
Easy Answers
rablighting.com
Visit our website for product info
Tech Help Line
Call our experts: 888 722-1000
e-mail
Answered promptly - [email protected]
Free Lighting Layouts
Answered online or by request
© 2020 RAB LIGHTING Inc.
Northvale, New Jersey 07647 USA
W17-30L/36L W17-55L/75L/90L
W17-150L
2 3/4"
8 5/8
16 1/2"
2 3/4" 12 1/2"
8 5/8
2 3/4" 9"
8 5/8
  • Page 1 1
  • Page 2 2

RAB Lighting W17-30LY Operating instructions

Type
Operating instructions
This manual is also suitable for

RAB Lighting W17-30LY is a high-quality, affordable, easy-to-install LED wall pack light designed for energy efficiency. It's perfect for a variety of outdoor lighting applications, including commercial and industrial buildings, parking lots, and security lighting. With its universal voltage driver, the W17-30LY can operate at 120V through 277V, 50 or 60 Hz, making it suitable for use in a wide range of locations. It also features a durable tempered glass lens that is easy to clean and maintain.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI