  • Hello! I am an AI chatbot trained to assist you with the Cooper Lighting WP Wal-Pak Glass Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • What safety precautions should be taken before installing the fixture?
    How to remove the door from the housing?
    How to install the wire guard on the door?
    What to do if the door reflector needs to be removed before drilling?
    How to determine the drilling points for a non-cut-off door?
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation,
operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.
NOTE: Specifications and dimensions subject to change without notice.
Wal-Pak Wire Guard
Sheet 1 of 1
2/10/10 IMI-721A
INSTALLATION INSTRUCTIONS
IMPORTANT : READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN FOR FUTURE REFERENCE
GENERAL: Upon receipt of the fixture, thoroughly inspect for any freight
damage which should be brought to the attention of the delivery carrier.
Compare the catalog description listed on the packing slip with the
fixture label on the housing to assure you have received the correct
material.
SAFETY: This fixture must be wired in accordance with the National
Electrical Code and applicable local codes and ordinances. Proper
grounding is required to insure personal safety. Carefully observe
grounding procedure under installation section.
WARNING: Make certain power is OFF before starting installation or
attempting any maintenance. Risk of fire/electric shock. If not qualified,
consult an electrician.
• RISK OF ELECTRIC SHOCK—Disconnect power at fuse or circuit
breaker before installing or servicing
• RISK OF BURN—Disconnect power and allow fixture to cool before
servicing
• RISK OF PERSONAL INJURY—Fixture may become damaged and/or
unstable if not installed properly.
• DO NOT mount luminaire within 6" of a combustible surface.
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 ADH100324
TOOLS REQUIRED: Drill, Phillips screwdriver, drill bit #26
FIELD INSTALLATION PROTECTIVE WIRE GUARD DOOR (FIG. 1 thru 4)
1. Using a Phillips screwdriver, loosening door screw. Support door while it swings open.
2. If necessary, door may be removed by detaching chain and removing chain screw; rotating the door to approximately 100° from closed
position to align the hinge and slide door out to the left. Do not force or rotate the door while sliding out as this will cause the hinges to
break.
3. Using drill bit #26, drill four (4) thru-holes from inside the door and perpendicular to door’s exterior surface FIG. 1. For FCO door FIG 2,
drill two (2) holes on the inside of door and two (2) holes on the outside of door FIG 3. Do not drill through door reflector. To avoid damage,
remove door reflector before drilling.
4. Install wire guard on the door with #8-32 Taptite screws (provided) FIG 4. Re-secure door to link chain. Re-install door by tightening door
screw until it comes to a stop.
Drlling points.
Using #26 drill bit
(non-cut off door)
FIG. 1
NON-CUT
OFF DOOR
FIG. 4
Wire
guard
#8-32
taptite
screw
Inside dirlling points.
Using drill bit #26
Inside door
reflector
FIG. 2
FCO DOOR
Reflector
door screws
Outside drilling points.
Using drill bit #26
(drill hole nornal to surface)
FIG. 3