ASO Safety Solutions ELMON relay 41-312 / 41-812 Owner's manual

Type
Owner's manual
Sicherheitsschaltgerät / Safety Relay / Relais de sécurité
Betriebsanleitung (Original,GülgkeitsieheletzteSeite)
ELMON relay 41-312 / 41-812 Sicherheitsschaltgerät
OperangManual (seelastpageforvalidity)
ELMON relay 41-312 / 41-812 Safety Relay
Manueld´ulisaon (Validitévoirladernièrepage)
ELMON relay 41-312 / 41-812 Relais de sécurité
Page 13-21
DeutschEnglishFrançais
Seite 3-12
Page 22-31
ELMON relay 41-312 / 41-812
12 13
Deutsch
ELMON relay 41-312 / 41-812
Sicherheitsschaltgerät
ELMON relay 41-312
ELMON relay 41-812
ELMON relay 41-322
ELMON relay 41-822
ELMON relay 41-312
ELMON relay 41-812
ELMON relay 41-322
ELMON relay 41-822
ELMON relay 41-312
ELMON relay 41-812
ELMON relay 41-322
ELMON relay 41-822
14
Safety Relay
1. Table of Contents
1. Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . .14
2. Generalsafetyregulaonsandproteconmeasures . . . . . . .15
3. Generalandfuncondescripon . . . . . . . . . . . . . . . . . .16
4. Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
5. Applicaonexample. . . . . . . . . . . . . . . . . . . . . . . . . .17
6. Deviceoverview . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
6.1 Versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
6.2 Signal indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
6.3 Conneconterminals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
6.4 DIPswitchforconguringtheoperangmode . . . . . . . . . . . . . . . . 19
7. Operangmodes . . . . . . . . . . . . . . . . . . . . . . . . . . .19
7.1 Safety output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
7.2 Automacreset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
7.3 Faultself-retaining–manualreset . . . . . . . . . . . . . . . . . . . . . . . 19
7.4 Signalingoutputwithoutanydelay(RLU) . . . . . . . . . . . . . . . . . . . 19
7.5 Signalingoutputdelayed(RL) . . . . . . . . . . . . . . . . . . . . . . . . . . 19
8. Mechanicalmounng . . . . . . . . . . . . . . . . . . . . . . . . .20
9. Electricalconnecon . . . . . . . . . . . . . . . . . . . . . . . . .20
9.1 Supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
9.2 Conneconofsensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
9.3 Conneconofmulplesensorspersensorcircuit. . . . . . . . . . . . . . . 20
9.4 Conneconofcontrolcircuits. . . . . . . . . . . . . . . . . . . . . . . . . . 21
9.5 ConneconReset. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
9.6 Conneconofsignalingcontact. . . . . . . . . . . . . . . . . . . . . . . . . 21
10.Commissioningandfuncontesng. . . . . . . . . . . . . . . . .22
11. Fault diagnosis . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
12. Decommissioning and disposal . . . . . . . . . . . . . . . . . . . .22
13. Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
14. ECDeclaraonofConformity. . . . . . . . . . . . . . . . . . . . .24
All rights reserved to implement technical and operaonally relevant changes of the
products and devices shown in this documentaon at any me without prior noce.
English
14 15
English
ELMON relay 41-312 / 41-812
Safety Relay
2. General safety regulaons and protecon measures
• Themanufactureranduserofthesystem/machineonwhichtheproteconsystemisusedareresponsible
forcoordinangandadheringtoallapplicablesafetyrulesandregulaonsundertheirownresponsibility.
• The proteconsystemguaranteesfunconal safetyincombinaonwiththe superordinatecontrol
system,butnotthesafetyoftheenresystem/machine.Thus,asafetyreviewoftheenresystem/
machineinaccordancewithmachinedirecve2006/42/ECorrelevantproductstandardsisnecessary
prior to use of the device.
• Theoperanginstruconsmustbepermanentlyavailableattheoperanglocaonoftheprotecon
device.Theymustbethoroughlyreadandappliedbyeverypersonwhoistaskedwiththeoperaon,
maintenanceorrepairoftheprotecondevice.
• Theinstallaonandstart-upoftheprotecondevicemayonlybeconductedbyspecializedpersonnel
who arefamiliar withthese operanginstruconsandthe applicableregulaonsonjob safetyand
accidentprevenon.Theinstruconsintheseoperanginstruconsmustbefollowedandadheredto
uncondionally.
• Electricalworkmayonlybecarriedoutbyskilledelectricians.Safetyregulaonsforelectricalengineering
andfromtheprofessionalassociaonmustbefollowed.
• Incaseworkhastobecarriedoutontheswitchingdevice,itmustbeswitchedtoavoltage-freeposion
andcheckedforfreedomfromanyvoltageandsecuredagainstbeingswitchedbackonagain.
• Ifthepotenal-freeconneconsofthesafetyswitchingcontactsaresuppliedwithahazardousvoltage
fromanexternalsource,it mustbe ensuredthatthese arealso switchedo when workingonthe
switchingdevice.
• Theswitchingdevicedoes not containanycomponentsthat theusermust service.Anywarrantyor
liabilityonthepartofthemanufacturerisforfeitedintheeventofanyunauthorizedmodicaonsor
repairstotheswitchingdevice.
• Auxiliaryoutputsmustnotexecuteanysafety-orientatedfuncons.Theyarenotfail-safeandarenot
checkedbytesngeither.
Thesystemmustbecheckedforcorrectfunconinsuitableintervalsbyqualiedpersonsforthe
standard-conform design of the safety system.
Thecheckmustbedocumentedinawaythatallowsittobetracedatanyme.
In the case of non-compliance or deliberate abuse, the manufacturer’s liability will cease.
16
Safety Relay
English
3. General and funcon descripon
TheELMONrelay41-312switchingdeviceisusedtoevaluatesensorssuchassafetycontactmats,safety
contactstripsandsafetybumpersforsecuringcrushandshearlocaons.
AnASOsensorcanbeconnectedtotheswitchingdevice.Thesteady-statecurrentmonitoringofthesensor
ismadepossiblebyanintegratedterminangresistorinthesensor.
Ifthedesiredsteady-statecurrentows,thesafetyrelaysaredrivenandtheswitchingcontactsclosed.
Ifthesensorisoperatedorthesensorcircuitisinterrupted,therelayswitchingcontactsopen.
A signal output with potenal-free switching contacts is available. An operaon of the sensor causes a
reaconofthesignaloutputinaccordancewiththeDIPswitchconguraon.Thesignaloutputmustnot
executeanysafety-orientatedfuncons.Itisnotfail-safeandnotcheckedbytesngeither.
Theswitchingdevice hasbeendesigned and type-approvedin accordancewithEN ISO 13849-1 “Safety-
relatedpartsofcontrolsystems”forcategory3PerformanceLevele.Forcompliancewithcategory3,the
safetyoutputissetupredundantlywithtwoindependentswitchingelements.
Inaddionthedevicehasbeentype-approvedaccordingtoEN62061“Funconalsafetyofsafety-related
electrical,electronicandprogrammableelectroniccontrolsystems“andcanmeetasafetyfunconupto
SIL 3.
ThemonitoringstateofthesensorandtheappliedoperangvoltageareindicatedbyLED.
Ifthereisafaultalarm,allsafetyoutputsareinacve.
Theunitcanbeusedinahouseholdenvironmentaswellasinanindustrialenvironmentupto
analtudeof2000mabovemeansealevel.Theunitmustnotbeoperatedinareaswithmajor
temperature changes.
Funconal circuit diagram
Reset
Mode
R
+U
DILSwitch
Logic
RESET
RESET
IN
IN
L1
N
24V AC/DC
24V AC/DC
AUX
AUX
STOP1
STOP1
STOP2
STOP2
16 17
English
ELMON relay 41-312 / 41-812
Safety Relay
5. Applicaon example
4. Intended use
Theswitchingdevicecanonlyfulllitssafety-relevanttask,ifitisusedasintendedwithinspecicaons.
Theintendeduseoftheswitchingdeviceistheuseasaproteconsysteminconneconwithsafetycontact
mats,safetybumpersandsafetycontactedgeswith8.2kΩresistanceforsteady-statecurrentmonitoring.
Adierentuseoranyuse goingbeyondtheintendeduse is notwithin specicaons.The manufacturer
doesnotacceptanyliabilityforanydamagearisingfromusenotwithinspecicaons.
Anyuseforspecialapplicaonsrequirespriorreleasebythemanufacturer.
Safety-orientatedmonitoringofasafetycontactstripwithstartreleaseviareleasepushbuonandseparate
connuaonofthecontrolcircuits(category3compliantapplicaonaccordingtoENISO13849-1).
InordertocheckthefunconalityoftheloadbreakingK1andK2relaysthebreakcontactsofthesecontactors
areintegratedintothestartcircuit(RESET).
Thesignalingrelayoutputisusedtovisualizetheswitchingstateofthesafetycontactedge.
Circuit diagram in voltage-free state. Sensor not operated.
1Sensor(edge,matorbumper)
2Releasekey
+24 V
M
13
14
K2
23
24
33
34
L1 L2 L3
5
8,2 Κ
14
K1
24 34
13 23 33
3110911
S1
64212 87
41
41
42
42
K2
K1
X1
Reset
0 V
K2
K1
18
Safety Relay
English
6. Device overview
6.1 Versions
Polycarbonatehousingwithbolngsforsurfaceinstallaoninaroughenvironment.
Version Supply voltage
ELMON relay 41-312 230V50/60Hzund24VAC/DC
ELMON relay 41-812 115V50/60Hzund24VAC/DC
Ifthereisnofaultalarm,theoperangstateisshownviathePowerLED(on).Whenafaultalarmisissued,
thenumberofpulsesoutputindicatesthefault:
Pulse Fault alarm
1 Voltage supply outside the valid value range
2 Faultwhentesngsignalinput
3 Output control relay faulty
4 Datatransmissionbetweenmicro-controllersfaulty
6.3 Connec on terminals
L1 N
ELMONrelay41-312:Supplyvoltage230V50/60Hz
ELMONrelay41-812:Supplyvoltage115V50/60Hz
24V AC/DC Supply voltage 24 V AC/DC
IN Conneconsensor
STOP 1 Switchingcontactsafetyrelay1
STOP 2 Switchingcontactsafetyrelay2
AUX Switchingcontactsignalingrelay
RESET Conneconmanualreset/re-start(keyNO;oponal)
6.2 Signal indicators
LED Power(green)
Operangstate(on)
Faultalarm(pulse)
LED Fault(red)
Sensoroperated(on)
Sensorpowercircuitinterrupted
(fastashing)
Fault self-retaining
(slowashing)
LED AUX(yellow)
Signaloutputswitched
18 19
English
ELMON relay 41-312 / 41-812
Safety Relay
6.4 DIP switch for conguring the operang mode
S1(AUX)
„ON“: AUXModesignaloutput: RLU
„OFF“: AUXModesignaloutput: RL(factoryseng)
S2(Reset)
„ON“: Automacreset
„OFF“: Faultself-retaining–manualreset(factoryseng)
7. Operang modes
7.1 Safety output
Separateorcombineduseofthecontrolcircuits(redundantconnuaonoftheswitchingcontacts).Inorder
tomakejointuseoftheswitchingcontactsofbothrelays,abridgemustbesetbetweentheSTOP1 and
STOP2 connecons.
7.2 Automac reset
(S2=„ON“)
Aerremovingafaultina sensor circuitor aera voltagefailure,the switchingunit willautomacally
release output again.
7.3 Fault self-retaining – manual reset
(S2=„OFF“)
Aerremovinglafaultinasensorcircuitoraeravoltagefailure,theswitchingunitwillonlyreleasethe
output(s)again,iftheRESET contacts, 500msaertheeliminaonofthedisrupon are closed by means
ofapushbuon. Thiscompletelypreventsanyautomacre-start.A permanentbridgingof the RESET
contactsdoesnotcauseanautomacreset.
7.4 Signaling output without any delay (RLU)
(S1=„ON“)
In this mode of operation the corresponding AUX
signalingoutputisacvatedwithoutdelay,ifanyfault
is signaled on the corresponding channel. The output
isalwaysinactiveinthe de-energizedstateofthe
switchingdevice.
7.5 Signaling output delayed (RL)
(S1=„OFF“)
Inthisoperatingmodethe AUXsignalingoutputis
acvatedwithadelayof0.5secondsandthenremains
acveforamaximumof3seconds,ifafaultissignaled.
Output
Aux. Relay
Output
Aux. Relay
3s
0,5s
Safetyoutput(symbolic)
Signalingoutput(symbolic)
Safetyoutput(symbolic)
Signalingoutput(symbolic)
20
Safety Relay
English
8. Mechanical mounng
Polycarbonatehousingwithbolngsforsurfaceinstallaoninaroughenvironment.
• Theswitchingdevicemustbemountedproperlyina suitablemounnglocaon.Aerthe
lid has been removed, the casing can be mounted by means of four bolts.
Do not install in the immediate vicinity of an intense heat source.
• Theunitmustnotbeoperatedinareaswithmajortemperaturechanges.
Theswitchingunitcanbeinstalledinanyposion,butinordertoprotectagainstanyingressofhumidityit
shouldbeedsuchthatthecableentriespointdownwards.
9. Electrical connecon
• Theswitchingunitcanbedestroyedbyconnecontotheincorrectterminals.
• Flexibleconneconleadsmustbesecuredagainstanyshiing.Themainsinfeedwiresmust
beaddionallyinsulatedbymeansofinsulaontubes.
• Linesthatareroutedintheopenairoroutsidetheswitchcabinetmustbeprotectedaccor-
dingly. For the unprotected external area only an appropriately approved cable may be used
(forexample:rubberlead).
• Thelimitvalues statedin the TechnicalData”forthe supply voltageandthe switching
capability of the relay must be observed.
9.1 Supply voltage
Thesupplyvoltagecanoponallybeeectedbymeansofamainsvoltageof230VAC50/60Hz
(ELMONrelay41-822:115VAC50/60Hz)oralowvoltageof24VAC/DC.Forasupplywith24V
AC/DCthevoltagemustcorrespondtotherequirementsforprotecvelowvoltages(SELV).The
supplylinetotheswitchingdevicemustbeprotectedbymeansofasuitablefuse.
Never apply both voltages simultaneously !
The 230 V supply voltage must be applied to the L1 Nterminals.Foroperaonwith24V,thesupplyvoltage
must be connected to the 24 V AC/DC terminals.
Foraxedinstallaonaseparangdevicemustbeavailable(forexample,amainswitchforthesystem).A
mainsplugissucientasaseparangdevice,ifitisfreelyaccessible.
9.2 Connecon of sensor
The
sensor
withaterminangresistorof8.2kΩmustbeconnectedtotheIN terminals.
9.3 Connecon of several sensors per sensor circuit
ASO sensors must not be connected in parallel.
One or several sensorscanbeconnectedtothesignal transmierinput.Forthis purpose,the individual
sensorsareconnectedinseriesinaccordancewithFigure1.
20 21
English
ELMON relay 41-312 / 41-812
Safety Relay
9.4 Connecon of control circuits
The control circuits to be monitored are to be connected to the STOP 1 and STOP 2.terminals If a redundant
connuaonoftheswitchingcontactsisnotdesired,abridgecanbeinsertedbetweenSTOP1 and STOP2.
Intheeventofanyredundantuseoftheswitchingcontactsonlyvoltageswiththesamepotenal
maybeconnected.Theuseofdierentvoltagepotenalsdoesnotcorrespondtoanyintended
usewithinspecicaons.
Depending on the nominal current, the control circuits are to be protected by a corresponding fuse or the
nominal current on the control circuits must be limited to the maximum value by means of other measures.
9.5 Connecon Reset
Fortheoperangmode“manualreset”thenecessaryresetswitchmustbeconnectedtotheRESET terminals.
9.6 Connecon of signaling contact
The signaling AUXcontactonlyservesasanauxiliarycontact(signaling,displayetc.)andmustnotbeinte-
grated into the safety circuit.
Safety contact edge SENTIR edge:
A maximum of 5 SENTIR edge devices can be connected in series. The maximum total length of the SENTIR
edge must not exceed 100 m.
The length of a SENTIR edge can be up to 25 m.
The total line length of the series-connected SENTIR edge must not exceed 25 m.
Safety contact bumper SENTIR bumper:
A maximum of 5 SENTIR bumper devices can be connected in series. The maximum total length of the SENTIR
bumpers must not exceed 15 m.
The length of a SENTIR bumper may be up to 3 m.
The total line length of the series-connected SENTIR bumpers must not exceed 25 m.
Safety contact mat SENTIR mat:
A maximum of 10 SENTIR mats can be connected in series. The maximum total surface area must not exceed
10 m2.
ThesizeofaSENTIRmatcanbeupto1350x2350mm.
The total line length of the series-connected SENTIR mat must not exceed 25 m.
Beforeconnecngtheseries-connectedsensors, it is recommended to measure the resistance value of the
wiring.Inthecaseofnon-operatedsensorstheresistancemustbe8.2kΩ±500Ω.Ifthesensor is operated,
theresistancemustnotexceed500Ω.
Fig. 1: Interconnecng several sensors, here using the example of the safety contact edge
Sensor 1
Sensor 2
Sensor „n“
O
C
2
222
22
Safety Relay
English
10. Commissioning and funcon tesng
Aera correspondingconnecon of allelectricalconnecons andswitchingon thesupplyvoltage,the
system/machinemustbecheckedforcorrectfunconality.
Aersuccessfulcommissioning,thesafetySTOP1 and STOP2outputsaredriven(relaycontactsclosed”).
Anoperaonofthesignaltransmiercausesanopeningoftherelaycontacts.
The signaling relay (AUXconnecon)switchesinaccordancewiththepresentDIPswitchposion.Thisis
indicatedbymeansoftheyellowAUX LED.
Thesafetysystemmustbe inspected bycompetentspecialists atsuitable intervals.The check mustbe
documentedinawaythatallowsit tobetracedatanyme.Therequirementsofthesystem/machine
manufactureraretobetakenintoaccountandobserved.
11. Fault diagnosis
Ifthesupplyvoltageiscorrectlywiredandapplied,onlythegreenPowerLEDmaybelitup.IftheredLED
illuminates,thereisafaultinthesystemwhichcanbedelimitedbymeansoftheLED.
* Ifthefaultisnotfoundinthewiring,thefunconoftheelectronicsystemcanbecheckedbyapplying
aresistanceof8.2kΩtothesensor-inputontheswitchingdevice.Subsequently,iftheelectronicswork
perfectly,thesensormustbecheckedbymeansofanohmmeter.Forthispurpose,theconneconof
thesensortotheswitchingdevicemustbeseparatedandconnectedbymeansofanohmmeter.Inthe
caseofanon-operatedsensortheresistancemustbe8.2kΩ±500Ω.If thesensorisoperated,the
resistancemustnotexceed500Ω.
12. Decommissioning and disposal
TheproductsmanufacturedbyASOareexclusivelyintendedforcommercialuse(B2B).Attheendofuse,the
productsmustbedisposedofaccordingtoalllocal,regionalandnaonalregulaons.ASOisalsohappyto
takebacktheproductsanddisposesofthemproperly.
LED Fault Fault removal
green LED
Power
does not light up
Supply voltage is missing,
toolowor
incorrectly connected.
Checkconneconsandsupplyvoltage:
-230VAC(or115V)atterminalsL1 N or
- 24 V AC/DC at terminals 24 V AC/DC
Tolerancerange:±10%
green LED
Power
ashescyclically
(pulseoutput)
Internal fault is indicated
by the number of pulses.
See -> signal displays
red LED
Fault
lights up
The corresponding sensor
isrecognized
as being operated.
-Checktheconneconsofthecorrespondingsensors
(squeezedorbrilesupplylines,etc.)
-Checksignalsensor*
red LED
Fault
fastashing
Sensor circuit interrupted,
sensor not connected,
defecvelyconnectedordefecve
-Checktheconneconsofthecorrespondingsensors
(squeezedorbrilesupplylines,etc.)
-Checksensor*
red LED
Fault
slowashing
Fault self-retaining Carry out manual reset
22
23
English
ELMON relay 41-312 / 41-812
Safety Relay
13. Technical data
Test report no.:
3512 6372
Cer cate no.:
44 780 13 xxxxxx
EC type-examina on no.:
44 205 13176203
Mains voltage UNetz
ELMONrelay41-312:230VAC50/60Hz
ELMONrelay41-812:115VAC50/60Hz
Supply type TypX
Lowvoltage U
E 24VAC/DC±10%
Powerconsumpon P
Netz_max 2,2VA230VAC(oder115V)
P
E_max 1,5 W 24 V DC
P
E_max 1,2 VA 24 V AC
Nominal value RNom =8,2kΩ
Upperswitching
point
R
AO >12,0kΩ
Lowerswitching
point
R
AU <5,0kΩ
Supply voltage Termina ng resistor – sensor
Nominal current DC 3A(30VDC)
Nominal current AC 1A(230VAC)
Mechanicallife-me >10
6
actuaons
Switch-odelay
(reaconme)
< 12 ms
Switch-ondelay 500ms(Poweron700ms)
Ulizaoncategory
AC-15(230VAC;1A;550000Op.)
DC-13(30VDC;3A;120000Op.)
Safety relay
max.switchingcurrent
2A(30VDC)
1A(230VAC)
Mechanicallife-me > 10
6
actuaons
OperangmodeRL:
Switch-ondelay
0,5Sek.
OperangmodeRL:
Switch-onduraon
3Sek.
Auxiliary relay
Housing ABS, transparent lid
(polycarbonate)
Dimensions(HxWxD)
Housing 120 x 80 x 56 mm
Housing incl. cable clamps 120 x 102 x 56 mm
Protecontype
withM16-cableclamps IP65
withM16-blankingplug IP54
Proteconclass II(protecveinsulaon)
Contaminaondegree 2
Overvoltage category III
Ratedinsulaonvoltage 250V
Ratedimpulsevoltageresistance 4,00kV
Weight 350 g
Temperature range -20 °C to +55 °C
Conneconcablecross-secon single-orne-strandedcable
0,75-1,5 mm
2
ELMONrelay41-312(41-812) ENISO13849-1:2008Category3PLe
(MTTFd236years,DC99%)
EN62061:2013SILCL3
(PFHd8,59E-091/h)
Electronics MTTFd 625 years,DC99%
Electromechanics
B10d 2000000
MTTFd380years,DC99%(Nop52560)
Cer ca ons
WiththeRLUversionthesignalrelayswitchessynchronously
totheoperaonofthesensor.
80
102
120
56
24
Safety Relay
English
ELMON relay 41-312
ELMON relay 41-812
ELMON relay 41-322
ELMON relay 41-822
ELMON relay 41-312
ELMON relay 41-812
ELMON relay 41-322
ELMON relay 41-822
ELMON relay 41-312
ELMON relay 41-812
ELMON relay 41-322
ELMON relay 41-822
34 35
Français
ELMON relay 41-312 / 41-812
Relais de sécurité
ELMON relay 41-312
ELMON relay 41-812
ELMON relay 41-322
ELMON relay 41-822
ELMON relay 41-312
ELMON relay 41-812
ELMON relay 41-322
ELMON relay 41-822
ELMON relay 41-312
ELMON relay 41-812
ELMON relay 41-322
ELMON relay 41-822
36
Antriebs- und Steuerungstechnik
Hansastraße 52 • D-59557 Lippstadt
Tel.: +49 2941 9793-0 • Fax: +49 2941 9793-299
www.asosafety.de • e-mail: aso-eu@asosafety.com
11.DB.18.001 Betriebsanleitung Rev 05
Technische Änderungen vorbehalten.
FürIrrtümerundDruckfehlerkannkeineHaungübernommenwerden.
DieseBetriebsanleitungistfürfolgendeVersionsständegülg:
von V 1.0 bis V 1.0
11.DB.18.001 OperangManual Rev 05
Subjecttotechnicalmodicaons.
No liability can be assumed for errors or misprints.
Thisoperangmanualisvalidforthefollowingversions:
from V 1.0 to V 1.0
11.DB.18.001 Manueld’ulisaon Rév 05
Sousréservedemodicaonstechniques.
Nous déclinons toute responsabilité en cas d'erreurs et de fautes d'impression.
Cemoded’emploin’estvalablequepourlesversionssuivantes:
deV1.0àV1.0
Deutsch
English
Français
Sicherheitsschltgerät / Safety Relay / Relais de sécurité
erstelltKHM26.06.2014 geändert:Glab13.12.2019
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

ASO Safety Solutions ELMON relay 41-312 / 41-812 Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI