5
III - Normal operation of the 30 sec. shot clock keyboard
1/ Pressing START / STOP key (1) starts the countdown of the shot clock. Pressing again stops the countdown.
When the countdown reaches 0, a sound signal is generated during 3 seconds. The LED (9) turns red when the shot clock is
stopped and green when the shot clock is running.
2/ Pressing the RESET 24s (2) key for few seconds turns o the display on the BTX6002 and on the keyboard.
When the key is released the shot clock timer is reset to its inial value of 30 sec.
3/ Pressing the CLEAR (3) key causes the blanking of the BTX6002 (the keyboard to displays - -). The timer
continues to countdown.
Pressing this key again causes the LCD display and the BTX6002 to display the current value of the timer.
4/ Pressing the HORN (4) key turns o the horn which comes on when the shot clock reaches 0.
This key does not turn on the horn.
5/ The RESET 20s (8) key is used to set the possession time to 20 seconds. This value can be modied from
the main Scorepad keyboard (see the Scorepad keyboard manual).
IV - Modication of the current shot clock timer value
1/ Stop the shot clock by pressing the START / STOP (1).
2/ Press the C key (6).
The keyboard LCD display, the keyboard LED (9) and the BTX6002 blink.
3/ Pressing the + (5) key increments the shot clock timer value by 1 second.
This value can be greater than the preset value of the RESET (2) (dafault value: 30 seconds).
4/ Pressing the - (7) key decrements the shot clock timer value by 1 second.
5/ Press the C (6) key to go back to normal operation.
V - Retrieval of the shot clock timer value
1/ If by accident, the RESET (2) key was pressed while the shot clock was running, it is possible to retrieve the
value that the timer held at the time of the accident by pressing the CLEAR (3) key within 2 seconds following
the accident.
START
STOP
RESET
14s
RESET
poss.
EFFACE
CLEAR
Time Pad
+
c
-
1 2
3
6
5
7
8
4
20s