Table of contents
Section 1 Introduction.......................................................................3
Section 2 Safety information............................................................ 5
Symbols on the product......................................................................5
Warnings............................................................................................ 5
Caution signs......................................................................................7
Section 3 Unpacking and inspecting................................................ 9
Removing transport packaging...........................................................9
Inspecting the product........................................................................ 9
Identifying the product................................................................... 9
Checking delivery items.................................................................9
Inspecting the IED......................................................................... 9
Returning an IED damaged in transit............................................ 9
Section 4 IED hardware................................................................. 11
Overview...........................................................................................11
Variants of case size with local HMI display................................11
Case from the front and rear sides.............................................. 13
Section 5 Powering up the IED...................................................... 19
How to know the voltage level.......................................................... 19
How to connect to the power supply.................................................20
Energizing the IED............................................................................21
Section 6 LHMI overview................................................................23
Local HMI......................................................................................... 23
Keypad........................................................................................ 23
Display.........................................................................................27
LEDs............................................................................................30
Local HMI functionality................................................................ 31
Protection and alarm indication.............................................. 31
Section 7 Connecting to the PCM600 software..............................33
PCM600 tool.....................................................................................33
Connectivity packages.................................................................33
Preparing for the connection............................................................ 34
Installing the PCM600 software........................................................34
Connecting the cables...................................................................... 34
Section 8 Editing the network settings........................................... 37
Table of contents
670/650 series 2.2 IEC 1
Quick start guide
Setting up communication between PCM600 and the IED...............38
Section 9 Working with the PCM software..................................... 43
Table of contents
2 670/650 series 2.2 IEC
Quick start guide
Section 1 Introduction
GUID-DCFD62E5-F592-4513-84B0-EC73C7C61838 v1
The Quick Start Guide contains instructions on how to setup the Relion 670/650
series IED to get started. The guide provides instructions to setup with a
preconfigured IED, however, it is also useful for the customized version of the
IED.
The guide describes basic instructions only. For complete information, see the IED
manuals.
GUID-CE76425E-C9C1-404F-8BB3-AD133E903EE7 V3 EN-US
Figure 1: Sample of an IED
1MRK 500 129-UEN A Section 1
Introduction
670/650 series 2.2 IEC 3
Quick start guide
4
Section 2 Safety information
2.1 Symbols on the product
GUID-E48F2EC3-6AB8-4ECF-A77E-F16CE45CA5FD v4
All warnings must be observed.
Read the entire manual before doing installation or any
maintenance work on the product.
Class 1 Laser product. Take adequate measures to protect your eyes
and do not view directly with optical instruments.
Do not touch the unit in operation. The installation shall take into
account the worst case temperature.
2.2 Warnings
IP1504-1 v2
Observe the warnings during all types of work related to the product.
GUID-C9B6638A-57E7-4E05-9A33-A60E359C54AF v1
Only electrically skilled persons with the proper authorization and
knowledge of any safety hazards are allowed to carry out the
electrical installation.
M2366-2 v2
National and local electrical safety regulations must always be
followed. Working in a high voltage environment requires serious
approach to avoid human injuries and damage to equipment.
M2362-2 v1
Do not touch circuitry during operation. Potentially lethal voltages
and currents are present.
1MRK 500 129-UEN A Section 2
Safety information
670/650 series 2.2 IEC 5
Quick start guide
M2364-2 v1
Always use suitable isolated test pins when measuring signals in
open circuitry. Potentially lethal voltages and currents are present.
M2370-2 v1
Never connect or disconnect a wire and/or a connector to or from a
IED during normal operation. Hazardous voltages and currents are
present that may be lethal. Operation may be disrupted and IED and
measuring circuitry may be damaged.
GUID-BEDD698E-356C-4CF9-9DAE-64DB3CEADEAD v1
Dangerous voltages can occur on the connectors, even though the
auxiliary voltage has been disconnected.
M2369-2 v3
Always connect the IED to protective earth, regardless of the
operating conditions. This also applies to special occasions such as
bench testing, demonstrations and off-site configuration. This is
class 1 equipment that shall be earthed.
M2367-2 v1
Never disconnect the secondary connection of current transformer
circuit without short-circuiting the transformers secondary
winding. Operating a current transformer with the secondary
winding open will cause a massive potential build-up that may
damage the transformer and may cause injuries to humans.
M2372-2 v1
Never remove any screw from a powered IED or from a IED
connected to powered circuitry. Potentially lethal voltages and
currents are present.
SEMOD168311-3 v1
Take adequate measures to protect the eyes. Never look into the
laser beam.
GUID-11CCF92B-E9E7-409C-84D0-DFDEA1DCBE85 v2
The IED with accessories should be mounted in a cubicle in a
restricted access area within a power station, substation or industrial
or retail environment.
Section 2 1MRK 500 129-UEN A
Safety information
6 670/650 series 2.2 IEC
Quick start guide
2.3 Caution signs
IP1503-1 v1
GUID-5D1412B8-8F9D-4D39-B6D1-60FB35797FD0 v2
Whenever changes are made in the IED, measures should be taken
to avoid inadvertent tripping.
GUID-F2A7BD77-80FB-48F0-AAE5-BE73DE520CC2 v1
The IED contains components which are sensitive to electrostatic
discharge. ESD precautions shall always be observed prior to
touching components.
M2695-2 v2
Always transport PCBs (modules) using certified conductive bags.
M2696-2 v1
Do not connect live wires to the IED. Internal circuitry may be
damaged
M2697-2 v2
Always use a conductive wrist strap connected to protective earth
when replacing modules. Electrostatic discharge (ESD) may
damage the module and IED circuitry.
M2698-2 v2
Take care to avoid electrical shock during installation and
commissioning.
M2693-2 v1
Changing the active setting group will inevitably change the IEDs
operation. Be careful and check regulations before making the
change.
GUID-3BEE51C6-8793-4C89-B8A8-07D0FA6EE4CA v3
Avoid touching the enclosure of the coupling capacitor REX061
unit and the shunt resistor REX062 unit. The surface may be hot
during normal operation. The temperature can rise 50°C in REX061
and 65°C in REX062 above the ambient temperature.
1MRK 500 129-UEN A Section 2
Safety information
670/650 series 2.2 IEC 7
Quick start guide
8
Section 3 Unpacking and inspecting
3.1 Removing transport packaging
AMU0600514 v5
IEDs require careful handling.
1. Examine the delivered products to ensure that they have not been damaged
during the transport.
2. Remove the transport packing carefully without force.
The cardboard packaging material is 100% recyclable.
3.2 Inspecting the product
3.2.1 Identifying the product
AMU0600513 v5
1. Locate the IED's order number from the label attached to the IED's case.
2. Compare the IED's order number with the ordering information to verify that
the received product is correct.
3.2.2 Checking delivery items
GUID-2A6D8F5A-470F-40D1-9EAE-60DE4DD85EE6 v1
Check that all items are included in the delivery in accordance with the delivery
documents.
3.2.3 Inspecting the IED
GUID-F6333353-F05D-4B41-BE44-5CE5274E788E v2
Check the IED to see if any damage occurred during transportation.
3.2.4 Returning an IED damaged in transit
GUID-966A05ED-CD30-4F66-957E-00FF38943A73 v4
If damage has occurred during transport, appropriate actions must be taken against
the latest carrier. Please inform the nearest ABB office or representative. Notify
1MRK 500 129-UEN A Section 3
Unpacking and inspecting
670/650 series 2.2 IEC 9
Quick start guide
ABB immediately if there are any discrepancies in relation to the delivery
documents.
Section 3 1MRK 500 129-UEN A
Unpacking and inspecting
10 670/650 series 2.2 IEC
Quick start guide
Section 4 IED hardware
4.1 Overview
IP14270-1 v1
4.1.1 Variants of case size with local HMI display
M15024-3 v6
IEC04000458-2-en.psd
IEC04000458 V2 EN-US
Figure 2: 1/2 19” case with local HMI display.
1MRK 500 129-UEN A Section 4
IED hardware
670/650 series 2.2 IEC 11
Quick start guide
IEC05000762-2-en.psd
IEC05000762 V2 EN-US
Figure 3: 3/4 19” case with local HMI display.
IEC04000460-2-en.psd
IEC04000460 V2 EN-US
Figure 4: 1/1 19” case with local HMI display.
Section 4 1MRK 500 129-UEN A
IED hardware
12 670/650 series 2.2 IEC
Quick start guide
4.1.2 Case from the front and rear sides
IP16286-1 v2
M16105-3 v10
Table 1: Designations for 1/2 x 19” casing with 1 TRM slot
1MRK002801-AC-2-670-1.2-PG V.3 EN
1MRK002801-AC-2-670-1.2-PG V4 EN-US
Rear position Module
X11 PSM
X31 and X32 etc. to X51 and X52 BIM, BOM, SOM, IOM or MIM
X301, X302, X303, X304 SFP
X305 LDCM
X306 LDCM or OEM
X3061, X3062 SFP if OEM is selected
X311: A, B, C, D SLM
X312 LDCM, IRIG-B, GTM
X313 LDCM, IRIG-B, GTM, RS485
X401 TRM
1MRK 500 129-UEN A Section 4
IED hardware
670/650 series 2.2 IEC 13
Quick start guide
SEMOD111882-4 v8
Table 2: Designations for 3/4 x 19” casing with 1 TRM slot
1MRK002801-AC-3-670-1.2-PG V4 EN-US
Rear position Module
X11 PSM
X31 and X32 etc. to X101 and X102 BIM, BOM, SOM, IOM or MIM
X301, X302, X303, X304 SFP
X305 LDCM
X306 LDCM
X3061, X3062 SFP if OEM is selected
X311: A, B, C, D SLM
X312 LDCM, IRIG-B, GTM
X313 LDCM, IRIG-B, GTM, RS485
X401 TRM
Section 4 1MRK 500 129-UEN A
IED hardware
14 670/650 series 2.2 IEC
Quick start guide
SEMOD111884-4 v7
Table 3: Designations for 3/4 x 19” casing with 2 TRM slot
1MRK002801-AC-4-670-1.2-PG V.3 EN
1MRK002801-AC-4-670-1.2-PG V4 EN-US
Rear position Module
X11 PSM
X31 and X32 etc. to X71 and X72 BIM, BOM, SOM, IOM or MIM
X301. X302, X303, X304 SFP
X305 LDCM
X306 LDCM
X3061, X3062 SFP if OEM is selected
X311: A, B, C, D SLM
X312 LDCM, IRIG-B, GTM
X313, X322, X323 LDCM, IRIG-B, GTM, RS485
X401 TRM 1
X411 TRM 2
1MRK 500 129-UEN A Section 4
IED hardware
670/650 series 2.2 IEC 15
Quick start guide
M16106-3 v10
Table 4: Designations for 1/1 x 19” casing with 1 TRM slot
1MRK002801-AC-5-670-1.2-PG V.3 EN
1MRK002801-AC-5-670-1.2-PG V4 EN-US
Rear position Module
X11 PSM
X31 and X32 etc. to X161
and X162
BIM, BOM, SOM, IOM or
MIM
X301, X302, X303, X304 SFP
X305 LDCM
X306 LDCM
X3061, X3062 SFP if OEM is selected
X311: A, B, C, D SLM
X312 LDCM, IRIG-B, GTM
X313 LDCM, IRIG-B, GTM,
RS485
X401 TRM
Section 4 1MRK 500 129-UEN A
IED hardware
16 670/650 series 2.2 IEC
Quick start guide
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50

ABB RELION 650 SERIES Quick start guide

Type
Quick start guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI