Dante DLM1985 Operating instructions

Category
Security cameras
Type
Operating instructions

This manual is also suitable for

1
DLM1971-DLM1985
PTZ Domes
Installation and Operations Manual
Model Number: DLM1971-DLM1985
Description: PTZ Domes, Color 18x, D/N 23x 26x,
27x, 30x, 35x and 36x
2
Catalog
Chapter 1
Installation manual
………………………………………… ……………………………3
1.Preface………………………………………………………………………………………………… 3
2.Safeguards and warnings………………………………………………………………… …………3
3.Special attention.........................................…………………………………….………………….3
4.Structure of high speed dome camera....................................................................................6
5.Main function features………………………………………………………………………………..6
6.Installation of the speed dome camera……………………………………………………………7
7.Specification………………………………………………………………………………………...…8
Chapter 2 Operation………………………………………………………………………………… ...… 12
1.Basic operation explanation……………………………………………………………….….. ……12
2.PTZ functions
………………………………………………………………………………..………15
3.Function explanation ………………………………………………………………………...……… 15
4.Menu explanation………………………………………………………………………………………16
5.Camera menu setting…………………………………………………………………………..…….. 16
6.Dial switch setting…………………………………………………………………………………..….21
Appendix
…………………………………………………………………………………………..…..… 24
1.P protocol……………………………………………………………………………………….........… 24
2.D protocol…………………………………………………………………………………………...... …26
3.RS-485 Control and feedback data protocol…………………………………………………...... …27
4.Target angle control communication protocol……………………………………………...... …28
Appendix
Troubleshooting ……………………………………………………………………… ……29
1.About image…………………………………………………………………………………….... .… 29
2.About control……………………………………………………………………………………….....…30
3.About installation…………………………………………………..…………………………….....… .30
3
Chapter 1: INSTALLATION MANUAL
1.PREFACE
This manual introduces the function, installation and operation of the integrated speed dome
camera in details. Please thoroughly familiarize yourself with the information in this manual prior to
installation.
This series dome cameras are equipped with DSP integrated camera, in-built zoom lens and
decoder controller.
Protocol P/D is used in this series dome cameras. It can support most popular system
platforms, such as: PELCO, MAXPRO. This manual will not explain the operation of other system if
connecting with other system, please contact with the system manufacture or dealer.
2.SAFEGUARD AND WARNING
Prior to installation and use of this product, the following WARNING should be observed. This
product can be only used in specified range in order to avoid any damage or danger.
Installation and servicing should only be done by qualified service personnel;
It must not be installed where exposed to rain and moisture and it can not be used in
unqualified temperature, humidity and power supply.
Only use replacement parts recommended by manufacturer.
After replacement/repair of this unit’s electrical components, conduct a resistance
measurement to avoid short circuit or turnoff.
Please use the soft cloth to clean the dome. Use neuter cleanser if bad smeared. No use the
strong or corrosive cleanser avoiding scuffing.
Be cautious of moving, never press the drive parts heavily avoiding dome troubles.
The installation materials should be capable of supporting four times the weight of the
enclosure, pan/tilt, camera and lens combination.
Please thoroughly read this manual prior to installation and operation
3. SPECIAL ATTENTION
(Prior to installation and use the speed dome, the following issues should be observed)
Standard voltage is 24VAC
the best range is 24VAC±
±±
±10%. The speed dome will have
abnormal hidden trouble if the voltage is too high or too low for long time. Power supply
should be kept more than 60W, otherwise the speed dome may reset or abnormal control.
The camera should not towards to strong light for long time, otherwise the CCD will easily
disabled, which will cause video lost or video anamorphic.
The speed dome has good waterproof, damp proof capability, reach IP66 standard. But if
the user doesn’t install the wirings in correct way, the rain will enter the dome drive along
4
the cabling, which will cause short circuit of the PCB board even damage the camera. Be
notice that our pendent bracket can not be used for outdoor. Please refer the following
installation of wirings:
Connect the power supply, video, control cables according to the instruction as following
picture:
Note
1.Cover the BNC head with rubber cover after connect the video BNC, to avoid the
BNC touch other metal.
2.RX
.RX
is the anode and cathode of RS-485, do connect them as the above
picture, otherwise the speed dome can’t be controlled normally.
3.It will be better if can connect the EARTH wiring. By connecting to the earth, the
5
RS-485 and video port can pass 10/700us 1500V differential-mode and
4000Vcommon-mode lightning strike and surge testing. Which reach ITU
T
K21
2003
international lightning proof standard and GB9043 standard. But it can’t prevent direct
lightning stroke, will need additional device.
4.Requirements for the connect cables
Requirements for the 24VAC power supply cable
Normally, the power wires have some resistance. There is some loss during voltage
transmission. The longer the wire is and the smaller the wire diameter is the worse loss will be.
Please refer to following wire diameter and distance requirement in order to avoiding the abnormal
work caused by insufficient voltage.
Power supply cable
diameter
0.5mm²(20#) 1.0mm²(18#) 1.5mm²(16#) 2.5mm²(14#)
Dome camera distance 11m(37ft) 18m(60ft) 29m(95ft) 46m(152ft)
Requirements for the video cable
The video wire also has inner loss as the power wire. The more the wire is and the small the
specification is, the worse loss it will be. The high the signal frequency is, the obvious the loss is.
The normal video wires models and the MAX. Transmission distance is listed in following table:
Video cable model Max. transmission
distance
Video cable model Max. transmiss
ion
distance
75-2 About 150m 75-5 About 370m
75-3 About 200m 75-7 About 500m
75-4 About 270m
75-9 About 680m
Requirements for RS-485 control cable
RS-485 cable transmission distance is relative to the cable diameter, transmission rate and
electro-magnetic interference condition. For examples: with a 1.0mm² twisted pair, if under 9600b/s
transmission rate, the longest transmission distance is 800M; if under 4800b/s transmission rate,
the longest transmission distance is 1000M; and if under 2400b/s transmission rate, the longest
transmission distance is 1200M.
Sometimes the installer use star connection mode, which doesn’t meet the industry standard
for RS-485 requirement. If the devices distance is far, it may cause signal reflect, reduce
Anti-interference capability and the camera will lose normal control. The suggestion is to parallel
connect a 120 ohm resistance at the fastest RS-485 anode and cathode; or adopt RS-485 distributor.
6
4. STRUCTURE OF HIGH SPEED DOME CAMERA (SEE PICTURE)
This series of Indoor/outdoor pendent speed dome camera contains three parts. Inspect each
box to make sure all parts are present.
Indoor/outdoor pendent speed dome camera contains following parts:
1. Back box
2. Dome drive
3. Lower dome
5.MAIN FUNCTION FEATURES
Aluminum-alloy back box, 6 inches polycarbonate, integrated design
Indoor and outdoor pendant installation
Accurate motor driving, without shocking, nosing during operation
High-reliability, built-in data never lost when the power is off.
RS-485 displays pan/tilt orientation, preset target angle.
Displays pan/tilt orientation and camera zoom
Built-in function menu, camera and pan/tilt can be set.
Powering-on self-restoring-----users can assign the movement after powering on.
Multi-automatic scan pattern, scan speed can be set by the inside menu.
Function of video freeze, wide dynamic, and backlight compensation.
Day and Night camera can be set to single color or backlight pattern according to the needs of circumstance.
Memory of pattern track function, can memory the preset transfer and all standards P/T/Z track.
Pan/tilt controlling speed’s self-restoring, pan/tilt speed and the depth of zoom lens declines proportionally.
Function of pattern track function, can memory the preset transfer and all standards P/T/Z track.
256 preset positions, which precision error less than 0.1°
°°
°preset target speed: 250°
°°
°/second for pan and 150°
°°
°
/second for tilt.
7
Variable self-touring speed can be set to1°
°°
°
40°
°°
°/second.
8 preset touring function: if the stopping time is between 5 sec and 60 sec can be set by the inside menu.
360°
°°
°continuously pan rotation, tilt rotation with self-flip.
Pan manual control speed: 0.1°
°°
°
150°
°°
°/sec, tilt manual control speed:0.1°
°°
°~
100°
°°
°/sec
7 alarming input, 2 AUX output.
Inside waving and lightening protection
Meeting IP66, CE, ROHS,FCC standards
6. Installation of the speed dome camera
STEP 1 Locate the Install Position
NOTE: Please make sure to airproof and damp-proof when the camera is outdoor installation.
1. Mount and install the back box, please refer to the manufacture’s install explanation. Insert the video ,
control and electrical wires into suspended bracket, and fix it.(see picture 1)
2. Press the environing spring and open the hinged door in the back box.(see picture 2)
3. Insert the video, control and electrical (or warning) wires into the back box through the mount.
4. Tighten the back box into the mount. If it is the outdoor installations, please thread the compound to the
threads in the back box.(see picture 3)
Picture 1 picture 2 Picture 3
STEP 2 Wire Circuit Board
Attach the wiring to the interconnected circuited circuit board inside the back box. When the powering on,
the red LED will light.
NOTE: Please refer to the TROUBLESHOOTING section, if the red LED does not light.
8
STEP 3 Install Dome Drive
GREEN TAB RED TAB
1. Set the protocol, baud rate, dome address and camera type for the needed position.
2. Line up the integrated dome drive’s red and green tabs with the green and red labels. Push the green tab
into the green label and the red tab into the red label, till both sides click into place.
3.
STEP 4 Install lower Dome
1. Apply lubricant to the O-ring. Install the O-ring in the groove on the trim ring of the lower dome.
2. Attach the back trim leash to the lower dome. Use retainer screw (nearest to a mounting screw) inside
lower dome.
Push the lower dome into the back box, line up the mounting screw holes, and install the two mounting screws.
7. SPECIFICATION
6.1STRUCTURE
Back box Aluminum alloy
Dome Drive Aluminum alloy, ABS Poly
Lower Dome Aluminum alloy, polypropylene Transparent Cover
Weight (approximate)
Unit weight Gross weight
3.5 kg 6 kg
Operation Environment indoor/Outdoor style
Working temperature -40°
°°
°
50
Measurement See measurement drawing (unit: mm)
9
6.2 Rotation Index (only for Dome Drive)
Horizontal rotation 360°
°°
°continuous pan rotation
Vertical rotation 0°
°°
°
92°
°°
°rotation
Manual control speed:
Pan 0.1°
°°
°
150°
°°
°/sec manual operation
Tilt 0.1°
°°
°
100°
°°
°/sec manual operation
Preset speed:
Pan 250°
°°
°/sec
Tilt 150°
°°
°/sec
6.3 Electrical index (only for Dome Drive)
Input voltage 18-30VAC; 24VAC
Input power 30VA
Fuse 2.0A
10
6.4 Camera, Lens parameters (Example)
Model 18×color
SONY
18×
day & night
SONY
26×
day & night
SONY
36×
day &
night
SONY
36×
day &
night
SONY
Optical Zoom
18 18 26 36
Electronic Zoom
12
Signal system
PAL/NSTC
Touring System
2:1 interleaved
CCD
1/4”CCD 1/4”HAD CCD
Horizontal
Resolution
>480TVL >540TVL
Lens
F1.4
(f=4.1~73.8mm)
F1.4
(f=4.1~73.8mm)
F1.6
(f=3.6~91mm)
F1.6~4.5
(f=3.4~122.4mm)
Pan angle
4.1mm wide
angle
Lens 48
0
73.8mm tele
angle
Lens 2.8
0
4.1mm wide
angle
Lens 48
0
73.8mm tele
angle
Lens 2.8
0
3.5mm wide
angle
Lens 54.2
0
91mm tele
angle
Lens 2.2
0
3.4mm wide angle
Lens 57.8
0
122.4mm tele angle
Lens 1.7
0
Focus
Auto/Manual First
Minimum
illumination
1/50 sec Shutter
speed(Color)1.0Lux
1/50 sec Shutter
speed
(Color)0.7Lux
1/3 sec Shutter
speed
(B&W)0.1Lux
ICR ON shutter
speed
(B&W) 0.01Lux
IR
1.0lux,1/5
sec
0.2lux,1/3
sec
ICR-ON
mode
0.15lux, 1/50
sec
0.01 lux,1/3
sec
IR
1.0Lux,1/60 sec
0.1Lux,1/4 sec
Night mode
0.1Lux, 1/4 sec
IR
Sync system
Inner Sync/AC linear lock
Inner/outer sync
Shutter Speed
Auto 1/50-1/10000 Auto 1/1-1/10000 Auto
1/3-1/10000
Auto 1/1-1/10000
Iris Ctrl
Auto/ Manual first Auto
Gain Ctrl
Auto/ Manual
Video Output
1.0+0.2VP-P(75ohm,compound) 1.0VP-P
S/N Ratio
50dB >50dB
White Balance
Auto/Manual
WDR
NO
11
Model 22×color
HITACHI
23×
day & night
HITACHI
30x
day & night
HITACHI
35×
day & night
HITACHI
27×
day & night
LG
Optical Zoom
22 23 35 35 27
Electronic Zoom
10 12 10
Signal system
PAL/NSTC
Touring System
2:1 interleaved Between lines 2:1 interleaved
CCD
1/4”CCD 1/4”HAD CCD 1/4”CCD
Horizontal
Resolution
>480TVL >540TVL >480TVL
Lens
F1.6
(f=4~88mm)
F1.6
(f=3.6~82.8mm)
F1.6
(f=3.4~102mm)
F1.6
(f=3.4~119mm)
F1.6
(f=3.6~98mm)
Focus
Auto/Manual First
Minimum
illumination
1.0Lux Color:1.0 Lux
B&W: 0.01 Lux
Color:1.0
Lux(PAL)
B&W: 0.01 Lux
Cut IR
Color:1.0
Lux(PAL)
B&W: 0.01 Lux
Cut IR
Color: 0.3 Lux
B&W:0.01Lux
Sync system
Inner Sync
Shutter Speed
Auto
1/50-1/30000
Auto 1/1.5-1/30000 Auto 1/1.5-1/30000 Auto
1/1.5-1/30000
Auto
1/50-1/10000
Iris Ctrl
Auto/ Manual first
Gain Ctrl
Auto/ Manual
Video Output
1.0VP-P(75ohm,compound output)
S/N Ratio
50dB
White Balance
Auto/Manual
WDR
NO YES YES YES NO
12
Chapter 2 OPERATION
1. BASIC FUNCTION EXPLANATION
After connect all wirings as the instruction and turn on the power, the dome camera will display
it’s configure information. And after configuration is done, the menu will show configure OK
information. If the user sets the POWER UP DONE, the dome will execute this movement and
the tips information disappear; if the user does not set the POWER UP DONE, the tips
information will be kept until the dome camera receive the control command, then the tips
information will disappear and show the system communication control is normal.
Power up display:
When configuring:
Configure OK:
NOTE: 1. VERSION 1.10 is the software version number of the dome camera, and it will change
as the product’s upgrade.
2. PROTOCOL P is control agreement, can support P, D protocol, and it will change as
the dial switch chooses different protocol.
3. ADDRESS 1 is control address, can support 256 addresses, and it will change as the
dial switch chooses different protocol.
4. COMM 4800.N.8.1 is communication information, 4800 is communication baud rate,
VERSION 1.10
PROTOCOL P
ADDRESS 1
COMM 4800.N.8.1
POWER UP DONE
VERSION 1.10
PROTOCOL P
ADDRESS 1
COMM 4800.N.8.1
CONFIGURING
VERSION 1.10
PROTOCOL P
ADDRESS 1
COMM 4800.N.8.1
CONFIGURE OK
13
there are 1200, 2400, 4800, 9600 four baud rate for different dial switch. N.8.1 means no verify, 8
data byte, 1 dwell position.
After the dome finish configure, the user can operate the dome as the following method
Operate Procedure
Pan/Tilt
1. To rocker control keyboard, camera will rotate to the operation
direction if the rocker leans to one direction of up/down/left/right.
The speed depends on the distance between rocker and center. The
camera will move slowly to the operation direction if move the
rocker lightly in one direction. The camera will speed to MAX.
Speed of continuously move the rocker in one direction. The
camera will stop when the rocker returns to the center.
2. To 2-dimension control keyboard, the camera will rotate to the
operating direction if press direction key. The speed depends on
the current speed code. To our KBD100 keyboard, press any one of
1-9, and then press direction key. The pressed number key is the
speed stage. The larger number it is, the higher speed will be. The
camera stops action of release the key.
3. To computer software control, press the direction key of control,
the camera will rotate to the operating direction. The speed
depends on current speed code. Some software can implement
continuous rotation and some only can implement dot movement.
Please refer to the software instruction provided by the
manufacture for detailed operations.
This dome can do 360
0
continuous pan rotation and +2
0
~-92
0
vertical rotations. It will stop rotate when reaching tilt limit.
STOP SCAN Preset 96(hit“9”+“6”+ “Preset”)
PRESET TOUR
Preset 98(hit“9”+“8”+ “Preset”)
PATTERN
1.press pattern scan setting to start
2. run the camera as the designed route
3.press pattern scan setting to stop
4.run the pattern scan, the camera will run the recorded route
AUTO SCAN Preset 99(hit“9”+“9”+ “Preset”)
ZOOM WIDE
1.Press the ZOOM WIDE button or turn the joystick clockwise until
you have the picture you want
2.release the button or joystick
ZOOM TELE
1.Press the ZOOM TELE button or turn the joystick anti-clockwise
until you have the picture you want
2.release the button or joystick
14
IRIS OPEN
Continuously press key OPEN to open iris and increase brightness
gain
IRIS CLOSE
Continuously press key CLOSE to close iris and increase
brightness gain
FOCUS NEAR
Continuously press key NEAR, focus become near from far, the
image becomes fog from clear or becomes clear from fog.
FOCUS FAR
Continuously press key FAR, focus become far from near, the
image becomes fog from clear or becomes clear from fog.
PRESETS
1. When set presetting, press “preset No.”+ key ”PRESET”(about
for 3 seconds)
2. when use presetting, press “preset No.”+ key ”PRESET”
3. Please refer to operation instruction book for controller.
Remarks:
The following stipulations are for presetting,
Preset() function
1-8 Tour
1-7 Preset positions for Alarming input
33 180º flip
34 lever home place
79 Open zoom on
80 Close zoom on
81 Auto low lux shift
82 Open low lux shift
B&W menu
83 Close low lux shift
color menu
84 Open wide dynamic
85 Close wide dynamic
86 Open Backlight Compensation
87 Close Backlight Compensation
88 Open video freeze
89 Close video freeze
92-93 Scan control limit
94 Exit menu
95 Enter menu
96 Scan stop
98 Preset tour
99 Auto scan
15
2. PTZ FUNCTIONS
This series of high-speed dome camera manual pan speed 0.1 º -150 º/second, manual tilt
speed 0.1 º ~100 º/second.
Pan/tilt speed and lens zoom is proportional, darker the lens zoom, slower the speed is!
The current position of P, T, Z three orientations (presetting positions) can be stored and
repeat use.
3. Function explanation
3.1 Screen menu function
It has screen menu function. All information can be displayed by menu to set the function
and parameter (only for LG and CNB camera)
3.2 Multi-cameras control function
Select different camera only by mending dial switch setting, no any hardware or software
needed. It supports LG, SONY, HITACHI, CNB cameras.
3.3 Proportion speed function
Horizontal and tilt speed change automatically with the zoom changes. When zooming
wide, the camera speeds down; then zooming narrow, the camera speeds up to catch better
tracing effect.
3.4 AUTO SCAN
Auto scan refers to the function of 360
0
continuous scan the images at certain speed on
the horizontal lever when keeping the pitching angle unchanged. The left and right limits can
be set for continuous scan at certain speed on the horizontal lever.
3.5 AUTO FLIP
When the camera tilts downward and goes just beyond the vertical position, the dome
rotates 180
0
. When the dome rotates, the camera starts moving upward as long as you
continue to hold the joystick in the down position. Once you let go of the joystick after the
dome rotates, joystick control returns to normal operation. The auto flip function is useful for
following a person who passes directly beneath the camera.
3.6 PRESET
Any position of dome camera PTZ can be conserved. We call it preset (pre-established
position). The preset can be transferred and cleaned.
3.7 PRESET TOUR
The dome camera will transfer pre- established preset 1-8 every 10 second. It will leap over
to next preset position if position in not among 1-8.
3.8 ZERO TEST
The dome camera will turn to horizontal and tilt zero by preset 34 when the inevitable
desynchronizing appears or the operator wants to find zero position during working process. It
can reset the orientation and is convenient for operators.
3.9 LOW SENSITIVITY (COLORS/BLACK AND WHITE SWIFT) FUNCTION
The camera automatically changes CCD sensitivity according to surrounding light. Color
image changes to black& white one in low sensitivity; black& white image changes to color
one in high sensitivity.(related to camera)
3.10 AUTO FOCUS MODE
The camera automatically adjusts lens focus to keep clear image if auto focus mode.
16
Manually operate FAR or NEAR focus adjustment can also adjust focus. The dome camera will
recover auto focus adjustment function if operate horizontal, vertical rotation or control lens
zoom.
3.11AUTO IRIS FUNCTION
The camera automatically adjusts iris to keep normal brightness in auto iris mode.
Manually operate OPEN or CLIOSE iris adjustment button can also adjust iris. The dome
camera will recover auto adjustment function if operated horizontally, vertical rotation or
control lens zoom.
3.12 BACKLIGHT COMPENSATION
The object will become black as the shadow if strong light appears in background.
Backlight compensation function can compensate the brightness automatically to dark
objects in bright light background and adjust the brightness background to avoid the image
full of brightness and get clear image. Too strong backlight can make the object illegibility.
4. MENU EXPLANATION
4.1 Operation explanation
This dome camera has in-built menu to set parameters for cameras and lens. The
contents in this chapter can make you a complete knowledge of this camera and do some
settings according to users’ requirements.
The basic operation contains move menu bar, enter next menu, return former menu,
change setting, verify change and cancel change.
Control up and down command: move menu bar and change setting
Iris open command: enter camera menu or select menu to verify change
Iris closed command: return former menu and cancel change
4.2 OPEN/EXIT MENU
This dome camera opens menu by preset 95 and exit by preset 94 according to P control
protocol. Please refer to controller instruction book for other control equipments.
Press “9”+”5”+”PRESET
Press key 95+ PRESET to enter dome camera menu
Press “9”+”4”+”PRESET”
Press key 94+ PRESET to exit dome camera menu
5. OPEN MAIN MENU
This series dome camera is stipulated according to P/D protocol, and use
preset position No.95 to open the main menu. For other protocol equipment,
please refer to protocol instruction.
NOTE:
1. “< >”symbol means it contains next menu
2. use “up, down” key to move cursor
”, use “OPEN or CLOSE” key to
confirm or exit the menu
17
3. when press “OPEN” key, the cursor becomes
”, then can use “UP or
DOWN” key to amend the parameter; press OPEN key when finish your
amendment.
5.1 MAIN MENU
<SYSTEM INFORMATION>
<DOME SETTING>
NOTE; this instruction book’s example is for
23×
××
× day& night camera, and it will be
Some changes for other cameras.
5.2 SECOND MENU
COMM
PROTOCOL
ADDRESS
VERSION
AUTO EXIT TIME, 5,6,7,8,9,10 minutes
NOTE: Except AUTO EXIT TIME, other items can only be showed not change in the
menu.
5.3 SECOND MENU
<CAMERA
>
<CAMERA
>
<PANTILT
>
<PANTILT
>
<POWER UP>
<LINE SYNC>
<ALARM>
<AUX>
PRESET DOME
DOME SETTINGS
<CAMERA
>
<CAMERA
>
<PANTILT
>
<PANTILT
>
<POWER UP>
<LINE SYNC>
<ALARM>
<AUX>
PRESET DOME
BACK
SYETEM INFORMATION
COMM 2400,N,8,1
PROTOCOL P
ADDRESS 1
VERSION 1.10
AUTO EXIT TIME 10
BACK
<SYSTEM INFORMATION>
<DOME SETTING>
EXIT
18
5.4 THIRD MENU
5.4.1 CAMERA MENU
AUTO FOCUS
ZOOM LIMIT
ZOOM SPEED
AUTO SHARPNESS
SHARPNESS LEVER
AUTO WHITE BALANCE
R GAIN
B GAIN
VIDEO FREEZE
WDR
AUTO FOCUS: ON & OFF, default setting is ON
ZOOM LIMIT: different camera with different zoom, default setting is X276
ZOOM SPEED: 4.2S& 5.8S, default setting is 4.2S
AUTO SHARPNESS: ON&OFF, default setting is ON
SHARPNESS LEVEL: 1~63 levels, default setting is 20
AUTO WHITE BALANCE: ON& OFF, default setting is ON
R GAIN: 0~1023, default setting is 180
B GAIN: 0~1023, default setting is 180
VIDEO FREEZE: ON & OFF, default setting is OFF
WDR (only for HITACHI VK-S454 camera): ON& OFF, and it can available only when the
backlight compensation setting is OFF.
5.4.2 CAMERA MENU
SHUTTER MODE
SHUTTER SPEED
AGC MODE
GAIN
AUTO IRIS
AUTO IRIS LEVEL
AUTO IRIS PEAK
BACKLIGHT COMP (BLC)
DAY/NIGHT MODE
DAY/NIGHT
SHUTTER MODE: AUTO& MAN, default setting is OFF
SHUTTER SPEED:1/1.5~1/30000, default setting is 1/50
AGC MODE: AUTO& MAN, default setting is AUTO
GAIN: 1~30Db, default setting is 6Db
AUTO IRIS: ON&OFF, default setting is ON
AUTO IRIS LEVEL: 1~100(available only when AUTO IRIS MODE IS OFF), and default
setting is 66
AUTO IRIS PEAK: 1~10, default setting is 10
CAMERA
SHUTTER MODE AUTO
SHUTTER SPEED 1/50
AGC MODE AUTO
GAIN 6dB
AUTO IRIS ON
AUTO IRIS LEVEL 66
AUTO IRIS PEAK 8
BACKLIGHT COMP(BLC) OFF
DAY/NIGHT MODE AUTO
DAY/NIGHT DAY
BACK
CAMERA
AUTO FOCUS ON
ZOOM LIMIT X276
ZOOM SPEED MEDIUM
AUTO SHARPNESS AUTO
SHARPNESS LEVER 10
AUTO WHITE BALANCE ON
R GAIN 180
B GAIN 180
VIDEO FREEZE OFF
WDR OFF
BACK
19
BACKLIGHT COMP (BLC): ON& OFF, default setting is OFF
DAY/NIGHT MODE (only for SONY-FCB480, SONY-FCB980, HITACHI VK-S454):
AUTO& MANUAL, default setting is AUTO
DAY/NIGHT (only available when DAY/NIGHT MODE IS MANUAL): DAY COLOR&
NIGHT B&W, default setting is AUTO
5.4.3 PAN& TILT MENU
AUTO FLIP
PROPORTIONAL PAN
PARK ACTION
PARK TIME
SCAN SPEED
AUTO FLIP: ON& OFF, default setting is ON
PROPORTIONAL PAN: ON& OFF, default setting is ON
PACK ACTION: NONE, 1PRESET~8PRESET, AUTO SCAN, PRESET TOUR,
PATTERN total 12 classes. And default setting is NONE.
PARK TIME: 0~60 minutes, default setting is 30.
PRESET TOUR TIME: 5~60 minutes, default setting is 10
SCAN SPEED: 1~40, default setting is 20
5.4.4 PAN& TILT MENU
LIMIT STOPS
MANUAL STOPS
SCAN STOPS
ANGLE DISPLAY
SET AZIMUTH ZERO
LIMIT STOPS: ON& OFF, default setting is OFF
MANUAL STOPS: ON & OFF, default setting is OFF
SCAN STOPS: ON & OFF, default setting is OFF
ANGLE DISPLAY: ON & OFF, set ON to display the pan& tilt angle and zoom, default
setting is ON.
SET AZIMUTH ZERO: Azimuth zero can set the camera to the zero position, then press
iris OPEN key to make sure azimuth zero.
5.4.5 POWER UP ACTION
POWER UP ACTION
POWER UP TIME
POWER UP ACTION: NONE,1PRESET~7PRESET, AUTO SCAN, PRESET TOUR,
PANTILT
AUTO FLIP OM
PROPORTIONAL PAN OFF
PARK ACTION NONE
PARK TIME 30
PRESET TOUR TIME 10
SCAN SPEED 10
BACK
PANTILT
LIMIT STOPS OFF
MANUAL STOPS OFF
SCAN STOPS OFF
ANGLE DISPLAY ON
SET AZIMUTH ZERO
BACK
POWER UP
POWER UP ACTION NONE
POWER UP TIME 10
BACK
20
PATTERN 12 classes, default setting is NONE.
POWER UP TIME: 1~10 minutes, default setting is10.
5.4.6 LINE SYNC
LINE SYNC
LINE SYNC PHASE
LINE SYNC: ON & OFF, default setting is OFF
LINE SYNC PHASE: 0~359, default setting is 0
5.4.7 ALARM INPUTS
ALARM1
ALARM2
ALARM3
ALARM4
ALARM5
ALARM6
ALARM7
ALARM1: 1~7 preset positions, press PATTERN to activate, default setting is1.
ALARM2: 1~7 preset positions, press PATTERN to activate, default setting is2.
ALARM3: 1~7 preset positions, press PATTERN to activate, default setting is3.
ALARM4: 1~7 preset positions, press PATTERN to activate, default setting is4.
ALARM5: 1~7 preset positions, press PATTERN to activate, default setting is5.
ALARM6: 1~7 preset positions, press PATTERN to activate, default setting is6.
ALARM7: 1~7 preset positions, press PATTERN to activate, default setting is7.
5.4.8 AUX OUTPUT
AUX1 MODE
AUX2 MODE
AUX1 MODE: 5V output, can activate it by alarm input or keyboard, default setting is alarm.
AUX12 MODE: Relay output, can activate it by alarm input or keyboard, default setting is alarm.
LINE SYNC
LINE SYNC
ON
LINE SYNC PHASE 0
BACK
ALARM
ALARM1 1
ALARM2 2
ALARM3 3
ALARM4 4
ALARM5 5
ALARM6 6
ALARM7 7
BACK
AUX
AUX1 MODE ALARM
AUX2 MODE ALARM
BACK
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31

Dante DLM1985 Operating instructions

Category
Security cameras
Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI