Optiview IRSPD 22X User manual

Type
User manual
IR High Speed 22X Dome Camera
Manual
Model: IRSPD 22X IR SPEED DOME
IRSPD 22X IR SPEED DOME
1
INDEX
Preface ......................................................................................................................... 3
1. Main feature.............................................................................................................. 3
2. Installation................................................................................................................. 4
3. Technical specification............................................................................................... 4
4. Setting........................................................................................................................ 6
4.1 Code Switch setting................................................................................................. 6
4.2 Speed Dome Camera Communication Protocol Setting…………………………… 7
4.3 Speed Dome Camera baud rate Setting……………………………………………….. 8
4.4 Integrative camera video TV system Setting…………………………………………… 8
4.5 RS-485 bus matching resistance setting………………………………………………… 8
5. Speed Dome Camera Address Setting…………………………………………………. 8
6. Self-test process…………………………………………………………………………. 9
7. Self-test process…………………………………………………………………………. 10
7.1 Variable speed……………………………………………………………………………. 10
7.2 Zoom speed…………………………………………………………………………….. 10
7.2 AUTO FLIP ……………………………………………………………………………….. 10
7.3 SCAN SPEED ………………………………………………………………………….. 10
7.4 PRESET FUNCTIONS …………………………………………………………………… 10
7.5 RANDOM SCANNING ………………………………………………………………….. 11
7.6 FRAME SCANNING ……………………………………………………………………..11
7.7 AUTO SCANNING …………………………………………………………………………11
7.8 Stop scanning …………………………………………………………………………….11
7.9 PATTERNS ……………………………………………………………………………….11
7.10 PARK ………………………………………………………………………………….11
7.11 AUTO FOCUS ……………………………………………………………………………..11
7.12 AUTO IRIS …………………………………………………………………………… 11
8. Operation ………………………………………………………………………… 11
9. OSD Operation ……………………………………………………………………… 14
10. OSD Menu ………………………………………………………………………………. 14
11. Main Menu ………………………………………………………………………………….15
12. Camera SETUP ………………………………………………………………………….. 15
12.1 ICON DISPLAY …………………………………………………………………………….. 17
12.2 ZOOM SPEED ………………………………………………………………………………17
12.3 DIGITAL ZOOM ……………………………………………………………………………..17
12.4 FOCUS MODE ………………………………………………………………………………17
12.5 PICTURE DISPLAY ……………………………………………………………………… 17
12.6 PICTURE NEGTIVE …………………………………………………………………………17
12.7 BLACK AND WHITE ………………………………………………………………………17
12.8 PICTURE REVERSE …………………………………………………………………………17
12.9 PICTURE FREEZE ……………………………………………………………………… 17
12.10 BACK LIGHT ……………………………………………………………………… 17
12.11 WHITE BALANCE ……………………………………………………………………17
12.12 SAVE AND UP TO TOP MENU ……………………………………………………… 17
13. PRIVACY ZONE ……………………………………………………… 18
14. PRESET POINT ……………………………………………………… …………………. 18
14.1 PRESET NUMBER …………………………………………………… 18
14.2 PRESET SPEED ………………………………………………… 18
14.3 DWELL TIME
14.4 CHARACTER
14.5 SAVE PRESET
IRSPD 22X IR SPEED DOME
2
14.6 UP TO TOP MENU …………………………………………………… 19
15. CRUISE SETUP
15.1 CRUISE NUMBER
15.2 PRESET INCLUDED
15.3 SAVING
15.4 TEST THE CRUISE
15.5 UP TO TOP MENU
16. PATTERN SETUP
16.1 SET PATTERN START&STOP …………………………………………………… 20
16.2 RUN THE PATTERN
16.3 UP TO TOP MENU
17. AUTO SCAN SETUP
17.1 LEFT LIMIT TIME
17.2 SAVING LEFT LIMIT
17.3 RIGHT LIMIT TIME
17.4 SAVING RIGHT LIMIT …………………………………………………………………….21
17.5 AUTO SCAN SPEED
17.6 TEST THE AUTO SCAN
17.7 UP TO TOP MENU
18. FRAME SCAN SETUP
18.1 SET FRAME SCAN SPEED
18.2 START FRAME SCAN
18.3 UP TO TOP MENU
19. PARK POINT SETUP
19.1 PARK TIME
19.2 FUNCTION STATUS
19.3 SAVE THE SETUP ……………………………………………………………………..22
19.4 UP TO TOP MENU
20. LOCATION INDICATIR
20.1 PAN POSITION
20.2 TILT POSITION
21. BASIC SETUP DISPLAY
Exception Handling ……………………………………………………………………………. 23
Address code chart ……………………………………………………………………………..24
PREFACE
IRSPD 22X IR SPEED DOME
3
This manual will introduce the basic functions, installation, operation and programming of
infrared high speed dome camera. Please read this instruction manual carefully before using
the product.
The Optiview Infrared high speed dome camera is equipped with high DSP integrated
camera, built in with zoom lens and decoder controller. It represents the latest development of
the new generation high technology Infrared High Speed Camera products. It adopts digital
control and have flexible program feature. The high precision drive system can set station or
positions arbitrarily and quickly; it can continue tracing scan on all directions thereby no blind
spot is missed to monitor. The High-power IR led with super low lllumination sensor IR
integrated camera gives a high quality picture on a dark environment. The Super low
illumination function makes it automatically adapt to any lighting environment and target
distance; the camera system is highly reliable and stable with no regular maintenance needed.
It supports protocols such as: PELCO-D,PELCO-P.
Warning
Before operating this product, please read follow safe regulation. To prevent any hazard, this
device only allowed to be used in limited scope.
(1) Only qualified technical engineer to install and maintain
(2) Don‟t install the indoor camera to rain or moisture place; don‟t use it in over limit
temperature, wet or power.
(3)The spare parts only can use by manufacture recommend;
(4) After replacing and maintaining the circuit unit, please use a multimeter to test, av
oid the short circuit and open circuit;
(5)While cleaning a camera cover, please use dry and soft cloth. If heavy dirty, please
use neutral detergent and wipe lightly.
Don't use mordant or abrasive detergent
(6) Be careful to move and no press.
(7) The bracket can bear 4 times of whole camera weight;
Before operating this product, please read this instruction manual carefully.
1. Main Characteristic
Inside IR high speed dome camera parameter
Parameter
Content
Image Sensor Device
1/4" EX-View HAD CCD
Pixel
440,000
Horizontal Resolution
480TVL
Lens
f=2.5mm(WIDE) to 91mm(TELE)F1.6 to F3.8
Optical zoom
26X
Digital zoom
12X
Angle of view(H)
54.2°WIDE endto 2.2°TELE end
Min.working distance
320mmWIDE end,1500mmTELE end
Min illumination
1.0 lux to 0.01 luxICR ON
S/N Ratio
> 50db
Electronic shutter speed
1/1 to1/10000 sec
Gain Aperture control
Auto/Manual
Back light compensation
ON/OFF
C/B
Auto/Manual control
IRSPD 22X IR SPEED DOME
4
IR CUT
Auto
Input power
6 to 12V DC
Inside Decoder parameter
Parameter
Content
IR shoot control
Low than 0.7 Lux auto on
C/B control
Synchronization
IR distance
100 meters / 328 feet
P/T circumrotation
360degree continuous,90degree
P/T speed
Pan:0 degree/S to 280 degree/S,Tilt:0 degree/S to180 degree/S
Preset
128,speed and dwell time optional
Cruise
8 route cruise,each route link with 16 preset
OSD On Screen
Display
English OSD
Privacy zone
2(function selectable)
Cruise memory
routePATTERN
1,88 sec
Scale zoom
Support(Function selectable)
Scan
Auto frame scanauto sector scanrandom scan
Especially course
1. HOME
2.move to reverse 180degree
Memery function
Auto memory & resume state
Baud rate
1200/2400/4800/9600 selectable
Communication
RS485
Protocol
PELCO-D,PELCO-P
Lightningproof
Video,power and communication super lightningproof & defend
surge
AC Adaptor
Included,Input power:AC 90V to 240V
Environment
Temperature:-40°C to + 60°C,Humidity:<90%RH
Bracket
Included
Weight
4.8kg
Certificate
CEFCCISO9000
Waterproof IP
IP66
The Infrared Medium speed dome camera is the most ideal security system, it famous for
high acceleration and steady running. It can run steady from 65 º/Sec to 0.1 º/Sec speed
IRSPD 22X IR SPEED DOME
5
Product appearance
2. Installation
Before the dome is installed, the communication protocol, baud rate and dome address,
should be confirmed. Set the code switch, keeping the setting consistent with the control
system. The relative code switch site and connecting check follows manual.
Attention: When use 1 general line to control two or more speed dome cameras, connect the
two speed dome camera on RS 485 ends joint with 1200ohm resistance. The match
resistance had design on the dial switch; you only need to dial “ON”. (Check 4.5 sections)
3. Technology Specification
Camera housing, inside camera & bracket: Aluminium
Dimension: see follow picture
Weight:
Net weight Packing weight
Camera housing 3.6kg 6.4kg
Inside camera 0.8kg 1.2kg
Temperature:-40ºC 65ºC
Device structure
Horizontal turn 360º continuous roll
Vertical turn +2º~-92º
Manual control Pan Tilt speed
Horizontal 0.1º65º/s manual operation
Vertical 0.1º65º/s manual operation
Preset speed
Horizontal 280º/s
Vertical 180º/s
Electric Index
Input voltageAC 90V260V
Input Power 25VA
Camera parameter
Signal System: PAL / NTSC
Scanning System separate row/ one by one line scanning
CCD 1/4"CCD
Effective Pixels 752(H)x582(v)
IRSPD 22X IR SPEED DOME
6
Horizontal Resolution >480TVL
Minimum Illumination
1.0Lux 1/50 sec(color)
0.1Lux 1/4 sec(color)
0.01Lux 1/4 sec(C/B)
0.05lux 1/2 sec(color)
0.1Lux 1/3 sec(color)
0.01Lux 1/3 sec(C/B)
Gain control:Auto, Manual first
Shutter speed Auto/ Manual 1/50-1/30000
Auto/ Manual 1/4-1/10000
Auto/ Manual 1/2-1/30000
S/N Ratio: 50dB
Video Output: 1.0V±.07V
Lens parameter
Optical Multiple: X16
X18
X22
X27
Electronic Multiple: X4
X8
X10
X12
Focus and Horizontal Angle: F1.4(f=4-64mm)4mm angle 43º,64mm angle 3º
F1.4(f=4.1-73.8mm4.1mm angle 43º, 73.8mm angle 2.5º
F1.6(f=4-88mm)4mm angle 43º, 88mm angle 2º
F1.6(f=3.6-82.8mm)3.6mm angle 45º, 82.8mm angle 2.1º
Focus: Auto, Manual First
Iris Control: Auto, Manual First
Infrared range: 328 ft.
4. Setting
Adjust the camera settings and wirings according to current environment before doing
the installation of the high speed dome camera to its final location such as knowing if a
controller keyboard or a DVR will be used to control the camera, setting the correct camera
address, baud rate,protocol etc. It is always a best practice to test the PTZ camera on a test
bench with your controller or DVR system and check all these settings and settle any
compatibility issues between PTZ camera and its main source of control (which could be a
PTZ controller or a DVR system). Consult your DVR tech support for any questions how to
configure the menu of the DVR for using or connecting a PTZ camera.
IRSPD 22X IR SPEED DOME
7
4.1 Code Switch Place
Systems setting depend on the code swith inside dome camera, as following picture:
Open the code swith cover, the relative code switch site and connecting wire are shown
below for reference.
The up code switch for dome address, the down for setting the communication
protocol, baud rate and relative RS-485 matching resistance.Below picture for indicate
the code switch ON & OFF:
IRSPD 22X IR SPEED DOME
8
4.2 Speed Dome Camera Communication Protocol Setting
Keep the dome camera communication protocol settings consistent with the control system.
Before the dome is installed the code switch of 1,2,3 OFF by Pelco-D & Pelco-P
Protocol,dome camera will auto identify the command under Pelco-D & Pelco-P Protocol,as
below picture:
4.3 Speed Dome Camera baud rate setting
Keep the dome camera baud rate setting consistent with the control system.Dome camera
support baud rate 1200bps,2400bps,4800bps & 9600bps.The 4th,5th on the code switch are
used to set baud rate.Please reference below picture(default value is 9600bps)
Note: Original Pelco keyboard the baud rate is 2400bps, Pelco-P is 4800bps.
4.4 Integrative camera video TV system Setting
IR high speed dome camera Video setting can be set to PAL or NTSC system. The 6
th
pin on
the code switch is used to set video TV system.As below picture, ON for NTSC; OFF for PAL
system (default value is PAL).
6
PALNTSC
6
4.5 RS-485 bus matching resistance setting
To ensure RS-485 bus video compatibility, the matching resistance should be set for the
device that is farthest away from the controller.There is an end matching resistance switch
board. The 8
th
bit shows ON status (see chart below) which means the BUS matching
resistance has been connected (default value is OFF)
Attention: SW1 for set communication protocol, baud rate, video TV system and
matching resistance.Protocol: (default value is Pelco-D, Pelco-P)
IRSPD 22X IR SPEED DOME
9
5. Speed Dome Camera Address Setting
Each PTZ camera must be assigned with a unique Camera address. The camera
addressing scheme is using binary system. For your convenience, you can follow
the chart to set an address to your camera.
6. Self-test process
WELCOME TO USE……” will display on the screen as following when power on.
WELCOME TO
USE……!
Then the system enters into the self-test. During the self-test, the current setup information
will display as followed.
SPEED DOME SETUP
■PELCO--D
ADDRESS:001
■PELCO--P
ADDRESS:002
■PROTOCOL: PELCO
D/P
■BAUD RATE:9600.N.8.1
■CAMERA TYPE: PAL
■FIRMWARE
VERSION:2.10
CONFIGURE DONE
After self checking, the system's information disappeared automatically, if you want to
exam the system information at any time, you can enter OSD (ON SCREEN DISPLAY) menu,
select” "BASIC SETUP DISPLAY" item then display system configure information.
After the self-test, pan and tilt coordinates will display at the right corner of the screen during
the normal work mode.
156□32
For example, current coordinate is 156°for pan and 32°for tilt.
IRSPD 22X IR SPEED DOME
10
Camera Functionalities
7. Self-test process
7.1 Variable speed
Horizontal direction
Vertical Direction
0.1 to 280º/s, depend on joy
stick‟s position
0.1to 180º/s, depend on joy
stick‟s position
0.1 to 280 º/s optional
0.1to 180 º/s optional
7.2 AUTO FLIP
When the camera turn down to perpendicular position, the camera will auto-rotate 180 º. If
the joy stick continue down, the camera will continue to uplift. Once you release joy stick after
the camera flip, the joy stick will recover to normal working. This function could be used to
track when someone pass the underneath of camera, it could also adopt auto flip function.
7.3 SCAN SPEED
The scan speed can be adjusted from 1~280º/s through program the speed dome camera
menu
7.4 PRESET FUNCTIONS
Preset function is setting and call preset position
Preset function is the speed dome camera take numeral(1-128) as position parameter ssuch as
level angle, perpendicular angle and camera lens focus etc. to store in the camera. It can use
the parameters to adjust the camera’s position. Operation is easy to call preset through joy s
tick and other equipment storage. The maximum preset number is 128,from 1 to 128.
Preset setting: Adjust the camera to the just position(include pan and tilt position‟s selection,
the camera zoom, focus and iris etc.), enter the preset number, pressing PRESET key and
keep at least for 5 seconds, then the preset set success.
Call preset:: Call preset is that the camera return to beforehand position quickly and
accurately. Enter preset number, pressing PRESET key and success.
Some preset numbers have special function, no longer have preset function. For exam
ple, The number 33 and 34 are fixed command, you can‟t program these two preset.
The number 33th is flip command which used for 180 º flip. The number 34th is used
for call command, the lens will run to camera‟s 0º position.
7.5 RANDOM SCANNING
Call number 97
th
then begin random scan; Direction and angles of scanning are all ra
ndom.
7.6 FRAME SCANNING
Call number 98
th
then activate frame scan, namely 360 degrees continuous loop scan;
The speed of frame scan can be set in OSD menu.
7.7 AUTO SCANNING
Call number 99
th
then start auto scan, namely sector scan.
The scan scope which contain scan left limitation, right limitation, and scan speed, cou
IRSPD 22X IR SPEED DOME
11
ld be control through software. Please make reference to the OSD menu enactment p
art to set scan limitation
7.8 Stop scanning
Call number 96
th
will stop any scanning; Press pan/tilt up-down, right-left key or the
lens control key can also stop scanning.
7.9 PATTERNS
Pattern can record the standard action and camera lens‟ movement automatically
within 90 seconds. But set and call preset function can't built in the pattern scan
routes, sector scan can set in the pattern routes.
7.10 PARK
When the dwell time is over the setting time, the camera would turn to park, and it
will display PARK. If time set is 0, or no park set, or park function not open, the
camera can't turn to park.
7.11 AUTO FOCUS
AUTO In this mode, camera will auto focus to the only position according to the
scenery‟s far and near
MANUAL manual adjust focus. When received any command to turn up-down or
left-right, the camera will return to auto focus condition automatically.
7.12 AUTO IRIS
AUTOIn this mode, iris will adjust automatically to the most suitable video brightness
OFF manual control.
8. Operation
Basic operations of speed dome are described as followed list.Those operations can be
done via OSD menu.
Function
Operation method
Pan and tilt
movement
Movement of joystick
Zoom in
Press Zoom In key
Zoom out
Press Zoom Out key
Focus far
Press Focus Far key, camera will work on manual focus mode
temporarily. It will automatically turn back to auto focus mode when
you move the joystick.
Focus near
Press Focus Near key, camera will work on manual focus mode
temporarily. It will automatically turn back to auto focus mode when
you move the joystick.
Iris open
Press Iris Open key, camera will work on manual iris mode
temporarily. It will automatically turn back to auto iris mode when
you move the joystick.
Iris close
Press Iris Close key, camera will work on manual iris mode
temporarily. It will automatically turn back to auto iris mode when
you move the joystick.
IRSPD 22X IR SPEED DOME
12
Random
scan
Call of 97 preset. „RANDOM‟ label will appear at the right corner of
the screen.
Frame scan
Call of 98 preset. „FRAME‟ label will appear at the right corner of the
screen.
Auto scan
Call of 99 preset or a little of movement of joystick will stop any
automatically movement, just like auto scan, pattern, frame scan etc.
Stop scan
Call of 96 preset or any movement of joystick.
Set Presets
Enter numbers you wanted, then press „PRESET‟ key for a few
seconds until label „PRESET ***‟ appears on the screen.
Call of
Preset (Go
to preset)
Enter numbers you wanted, then press „PRESET‟ key, then label
„PRESET ***‟ appears on the screen.
Pattern start
and stop
Pattern can repeat the trace of the movement of speed dome during
a certain time. Press number „1‟, then press „PATTERN‟ key for a
few seconds until the label „TRACE‟ appear on the screen. Then
move the speed dome pan, tilt and zoom. Press „ACK‟ key to stop
and confirm the trace. During the recording, „TRACE:**S‟ indicate
the last time. The total time is 90 seconds.
Or:
Set 90 to start a pattern recording;
Set 91 to end a pattern recording;
Run pattern
Press number 1 and then „PATTERN‟ key to ran the pattern. A label
„PATTERN‟ appears on the right corner to indicate work mode. User
can also run the pattern by a call of 87 preset.
Run cruise
A call of 86 preset will run the cruise. During the cruise work mode, a
label „CRUISE‟ appears at the right corner of the screen.
Open and
close OSD
menu
Set or call of 95 preset will open or close the OSD menu at any time.
It is a flip-flop soft switch.
Flip
Call of 33 preset will reverse the camera.
Home
Call of 34 preset will move the camera to pan zero.
Set of the
left limit of
auto scan
Set of 92 preset will set the left limit of auto scan. A label „LEFT
LIMIT‟ will appear at the bottom of the screen.
Set of the
right limit of
auto scan
Set of 93 preset will set the left limit of auto scan. A label „RIGHT
LIMIT‟ will appear at the bottom of the screen.
Set park
station
Set of 87 preset will set the park location. A label „SET PARK‟ will
appear at the bottom of the screen. When there are no movement
control commands from keyboard or DVR for a few times, camera
will move to the parking station, a label „PARK‟ will appear at the
right corner of the screen. The time can be set via the OSD menu.
IRSPD 22X IR SPEED DOME
13
Park enable
Set of 88 preset will enable the parking function. A label „PARK
ENABLE‟ will appear at the bottom of the screen.
Note: Don‟t enable parking function when dome is in any scan work
mode, just like frame scan, auto scan etc. Otherwise, this will result
in a false movement.
Park disable
Set of 89 preset will disable the parking function. A label „PARK
DISABLE‟ will appear at the bottom of the screen.
Actually, a lot of controllers or DVR have no function of sending special control comm
and, so many functions complete through set or call different preset position. And the
special used presets have no normal function. Follow form show special functions thro
ugh preset setting.
Preset Number
Complete Function
87
Set PARK position
88
Open PARK function
89
Stop PARK function
90
PATTERN START
91
PATTERN END
92
Set left limit of auto
scanning
93
Set right limit of auto
scanning
95
Enter/Exit OSD menu
Follow form complete special functions through call preset.
Transfer preset
number
Complete function
33
Horizontal reversal 180º
(Flip)
34
Return to 0º(Home)
86
Start default cruising
group
87
Start PATTERN
95
flip/stop OSD menu
96
Stop Scan
97
Random Scan
98
Frame Scan
99
Auto Scan
9. OSD Operation
OSD menu provides a user friendly interface. User can simply operate the dome and
obtain any information from the dome, no need of memory of so many commands.
The method of opening the menu: OSD menu will appear on the screen for the first time
of set or call of 95 preset at any time. Menu will be closed for the second time of set or call 95
preset.
After entering into the OSD menu, Focus FarFocus NearIris Open and Iris Close keys
will be used to operate the menu item. When exiting the menu and back to the normal work
mode, the function of the four keys will turn back to their original function.
As long as OSD menu is turned on, the function of the four keys is described as
following.
IRSPD 22X IR SPEED DOME
14
Focus Far: Cursor move up
Focus Near: Cursor move down
Iris Open: The values of the item decrease 1, or select another option.
Iris Close: The values of the item increases 1, or select another option, or confirm the
function selected, just like a ENTER key of a PC keyboard.
10. OSD Menu
Enter or exit OSD menu by press 95+PRESE key.
According to PELCO controller to program 95+PRESET, different PELCO control with
different program command.
If using any one of the following Pelco Devices:
CM6700,CM6800
(1) Press key "CAM" after input Camera's number
(2) Input number 95 and press key "PRESET" and keep 2 seconds
(3) In EDIT menu, move cursor to "SET" then press key "ACK", camera main menu will display.
KBD200A/KBD300A/KBD300V(only for direct control)
(1) Press number 95
(2) Press key "PRESET" about 5 seconds until main menu display
CM8500
(1) Press key "CAM" and input Camera's number
(2) Move cursor to "PRESET" on OSD, press button on Joy stick until set tip display
(3) Input 95 and press key "PRESET", the edit words appear, choose ENTER, the main menu display.
CM9500
(1) Press key "CAM" and input camera's number
(2) Brighten “Setup” on main menu, press key SELECT
(3) Brighten “Cam” on Setup menu, press key SELECT
(4) Brighten “Preset” on Cam menu, press key SELECT
(5) Input 95 and press key F1, the main menu display
CM9740/9760
(1)Press key ESCAPE open main menu, select DEF, the detailed menu display
(2)If you are the first time enter this mode, please enter your four number pass-word
(3)Input 95 and select PRESET, the main menu display on Monitor
(4)Select icons QUIT and return default setting menu.
KBD4000/KBD4002/KBD4000V
(1) Press key SPOT MONITOR
(2) Input 95, press key PRESET about 5 seconds until the main menu display on monitor.
PelcoNet
(1) Select SET BOX
(2) Input preset number 95, the main menu will display.
IRSPD 22X IR SPEED DOME
15
11. Main Menu
The screen will be as following after entering into OSD menu.
■CAMERA SETUP
PRIVACY ZONE
PRESET POINT
CRUISE SETUP
PATTERN SETUP
AUTO SCAN SETUP
FRAME SCAN SETUP
PARK POINT SETUP
LOCATION
INDICATOR
BASIC SETUP
DISPLAY
„■‟ is a cursor. It indicates which item is being operated currently. When switch items by
using of the Focus Far and Focus Near keys, cursor „■‟ will move up or down.
Press Iris Close key for any item of the main menu, you will enter into the submenu.
User can operate the dome according to the tips from the menu.
12. Camera SETUP
Move cursor to"CAMERA SETUP" and press Iris Close key, you will enter into the
submenu as follow:
■ICON DISPLAY:OFF
ZOOM SPEED:5
DIGITAL ZOOM:ON
FOCUS MODE:AUTO
PICTURE DISPLAY:ON
PICTURE NEGTIVE:OFF
BLACK AND:WHITE:OFF
PICTURE REVERSE:OFF
PICTURE FREEZE:OFF
BACK LIGHT:ON
WHITE BALANCE:AUTO
SAVE AND UP TO TOP MENU
Each item in this menu is about camera function setting. Select function through
Focus Far and Focus Near key, and then switch by Iris Close key.
Remarks: Part function different according to different brand and model of the
camera.
IRSPD 22X IR SPEED DOME
16
Details for all functions as follow,
12.1 ICON DISPLAY
ON: display as iconic format for the state of camera ZOOM, IRIS, FOCUS (default setting)
OFF: no picture
12.2 ZOOM SPEED
8 grade zoom speed in total: 0-7 grade, 0 grades is slowest speed, 7 grades is the fastest,
(default setting: 5 grades).
12.3 DIGITAL ZOOM
AUTO: If auto focus, press FOCUS FAR and FOCUS NEAR will set the focus, if you
operate pan tilt, camera will return to best focus after pitching and zoom.
OFF: If focus set OFF, press FOCUS FAR and FOCUS NEAR key for focus.
12.4 FOCUS MODE
AUTO: auto focus mode (default setting)
Manual: manual focus mode
12.5 PICTURE DISPLAY
ON: display natural video picture (default setting)
OFF: close video output
12.6 PICTURE NEGTIVE
ON: video picture change to negative
OFF: natural display picture (default setting)
12.7 BLACK AND WHITE
ON: B/W
OFF: COLOR (default setting)
12.8 PICTURE REVERSE
ON: video picture right-left (up-down) reverse
OFF: natural video picture (default setting)
12.9 PICTURE FREEZE
ON: picture freeze
OFF: natural picture (default setting)
12.10 BACK LIGHT
ON: open
OFF: close (default setting)
12.11 WHITE BALANCE
AUTO: auto white balance mode
IRSPD 22X IR SPEED DOME
17
INDOOR: indoor white balance mode
OUTDOOR: outdoor white balance mode
ATW: auto track white balance mode
12.12 SAVE AND UP TO TOP MENU
Save all setting and return to top menu.Memorize all setting when power off.
13. PRIVACY ZONE
Not support.
14. PRESET POINT
Preset positions setting and call
Preset position setting: memory current pan tilt‟s horizontal and vertical direction and
camera state.
Call preset: pan tilt and camera run to beforehand setting and memory state.
Press Iris Close key on PRESET POINT menu, it will display:
■PRESET
NUMBER:003(USED)
PRESET SPEED:64
(MAX64)
DWELL TIME:00
(MAX60)
CHARACTER:OFF
SAVE PRESET
UP TO TOP MENU
14.1 PRESET NUMBER
Select preset number, camera will move to preset position if selected and display
"USED" at right. If not set, it will display NOT.
14.2 PRESET SPEED
Setting horizontal and vertical speed for preset position, 1-64 grade, 1 is the slowest and
64 is the fastest (default setting 64)
14.3 DWELL TIME
Dwell time within 00-60 seconds (default setting 0).
14.4 CHARACTER
ON: Character display on screen
OFF: no Character display
14.5 SAVE PRESET
Setting or revise preset
Adjust pan tilt and camera to the right position and press Iris Close key, and then
begin to memory this preset. Display"... ...OK" and succeed.
14.6 UP TO TOP MENU
IRSPD 22X IR SPEED DOME
18
15. CRUISE SETUP
Drop and enter submenu as following:
■CRUISE NUMBER:1
PRESET INCLUDED:
(01)001 (02)002 (03)005
(04) (05)007 (06)
(07)008 (08) (09)
(10) (11) (12)
(13) (14) (15)
(16)
SAVING
TEST THE CRUISE
UP TO TOP MENU
Each Cruising group tracks 16 presets, for example above format indicate: start
cruise group 1 will cruise 1, 2,5,7,8 preset times after time.
15.1 CRUISE NUMBER
Setting Cruise number (default setting 1)
15.2 PRESET INCLUDED
Setting and display cruise preset, switch by Focus Far and Focus Near key within 16
preset point, set preset number by Iris Open and Iris Close key in range 1-128.
15.3 SAVING
Display “……OK!”And succeed
15.4 TEST THE CRUISE
Press“95 + PRESET”to close the OSD
15.5 UP TO TOP MENU
16. PATTERN SETUP
PATTERB SETUP menu is used for set and run pattern scan. Enter and display:
■SET PATTERN
START&STOP
RUN THE PATTERN
UP TO TOP MENU
IRSPD 22X IR SPEED DOME
19
16.1 SET PATTERN START&STOP
Press Iris Close key, camera begin to memorize run track, included horizontal, vertical
tracking and camera zoom, call preset. Press Iris Close key again, it will stop memory.
Pattern time is 90 seconds and “TRACE: XX”show the time left for tracking.
16.2 RUN THE PATTERN
Press"95+PRESET" can close OSD MENU. The screen will display "PATTERN" when run
PATTERN.
16.3 UP TO TOP MENU
17. AUTO SCAN SETUP
This item for setting the started and end point and speed of Auto scan namely detector
scan. Press Iris Close key and display as follow:
■LEFT LIMIT TIME:01
SAVING LEFT LIMIT
RIGHT LIMIT TIME:01
SAVING RIGHT LIMIT
AUTO SCAN SPEED:64
TEST THE AUTO SCAN
UP TO TOP MENU
Auto scan: Pan Tilt scanning between LEFT LIMIT and RIGHT LIMIT. The horizontal and
vertical position for LIMIT is alterable.
17.1 LEFT LIMIT TIME
Set the dwell time on LEFT LIMIT position, time bound is 0-60 seconds.
17.2 SAVING LEFT LIMIT
Run the pan tilt to aim point, press "Iris Close" key and this point is memorized as the
LEFT LIMIT position and memorize dwell time.
17.3 RIGHT LIMIT TIME
Set the dwell time on Right Limit position, time bound is 0-60 seconds.
17.4 SAVING RIGHT LIMIT
Run the pan tilt to aim point, press "Iris Close" key and this point is memorized as the
RIGHT LIMIT position and memorize dwell time.
17.5 AUTO SCAN SPEED
Speed scope: 0-64
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29

Optiview IRSPD 22X User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI