Harvest TEC 6672C User manual

Type
User manual
6672C-19-Imp&Metric
6/22
Owner’s Manual
Model 6672C
600 Series iPad Integration Conversion Kit
Forage Harvester
2
DECLARATION OF INCORPORATION
MANUFACTURER: Harvest Tec LLC.
2821 Harvey St.
P.O. Box 63
Hudson, WI 54016, U.S.A.
REPRESENTATIVE ESTABLISHED IN COMMUNITY: Profitable Farming Company
Middle Barlington, Roborough
Winkleigh, Devon, EX19 8AG
ENGLAND
The person above certifies and declares that:
VIRTUAL MACHINE: Equipment mounted on a farm press and for the application of innoculants onto
forage crops.
MODEL: 6672C-19-Imp&Metric
BRAND: Harvest Tec
SERIAL NUMBER:
This application preservatives for hay Harvest Tec system meets the Directive 2006/42/EC of the
European Parliment and the Council of 17 May 2006 and other applicable European Directives
including Directive 2004/108/EC on the Electromagnetic compatability.
The application of preservatives for hay Harvest Tec system will be turned on after being installed on
a farm press has been declard in conformity with the Machinery Directive.
Person in the community authorized to provide information on the partly completed machinery and
making this statement:
Richard Snell, President, Profitable Farming Company
Signed on May 21, 2011: Middle Barlington, Roborough
Winkleigh, Devon, EX19 8AG
ENGLAND
3
Harvest Tec 6672C Table of Contents
Page
Installation of iPad Integration Control
4-7
iPad Integration Control Light Signals
4
Large Square Baler Power Cable and Main Wiring Harness Installation
5
Round Baler Power Cable and Main Wiring Harness Installation
6
Small Square Baler Power Cable and Main Wiring Harness Installation
7
Operation
8
Operation of iPad App & Turn On/Off iPad
8
Downloading the Hay App
8
Shutting Down the Hay App
9
Device Selection
10
Demo Tab, Manual Selection & Recommended Preservative
11
Main Menu & Tab Descriptions
12
Screen Menus
13-15
Automatic Mode & Manual Mode
13
Setup mode Large Square Balers
14-17
Setup mode Round Balers
18
Setup mode Small Square Balers
19
Job records Large Square Balers
20
Job records Round & Small Square Balers
21
First time and Annual Startup Instructions
22-24
Large Square Balers
22
Round Balers
23
Small Square Balers
24
Setting Up the system for Initial Use Large Square
25-27
Application Rate
25
Bale Rate Settings
26
Bale Rate Settings-Baler Sensors & RFV Setup
27
Setting Up the system for Initial Use Round Balers
28-29
Setting Up the system for Initial Use Small Square Balers
30-31
Application Rate, Baling Rate & Stroke Counter Setup
31
Operation Instructions Large Square Balers
32-33
Automatic Mode
32
Manual Mode
33
Operation Instructions Round Balers
34-35
Operation Instructions Small Square Baler
36-37
Automatic Mode
36
Manual Mode
37
Job Records
38-42
Large Square
38
Round and Small Square Balers
39
Downloading Job Records
40
Exporting Job Records (emailing records)
41
Exporting Job Records (saving to iPad)
42
Common Questions
43
Troubleshooting
43-45
iPad Troubleshooting
46
Warranty Statement
47
4
Installation of iPad Integration Control
Locate a safe location in the cab of the tractor to place the iPad
Integration Control (030-6672C). Recommended location is securely
fastened out of the operators way in a location that is close enough to
reach with the iPad cord.
Connect the Power / Communication harness (006-6650TM(E)) to the
bottom of the receiver.
To operate the applicator, plug the iPad cord into the communication
port indicated by:
iPad Integration Control Light Signals
Green Slow Blink Power supplied to the applicator system and the unit is going through its startup process.
This will take approximately 25-35 seconds.
Green Double Blink Indicating the iPad module recognizes the iPad but the app is not open or connected.
Green Solid Light Module is connected to the app and is ready to operate.
*Recommended to use the USB cable included with the applicator kit (006-6672USBC)
Bluetooth Receiver Lights
Pre-2020 applcaitors equipped with Bluetooth receivers (030-6672B)
are now equipped with lights to indicate both power and Hay App
connection on the Apple iPad. Clean light regularly
Blinking Lights System is waiting for the processor to connect, which
could take up to 35 seconds.
Red Light The Bluetooth receiver has power
Green Light The Bluetooth receiver is connected to the Hay App.
**600 Series Applicators with serial number before DCP27000 will require the DCP to be sent to Harvest
Tec for a required update in order to use the iPad Integration Module (030-6672C).
Hay App version must be at least 2.7.1 (or higher) to operate with the iPad Integration Module
*Made for Apple iPad badge
Use of the Made for Apple iPad badge means that an accessory has been designed to connect specifically to
the Apple product(s) identified in the badge and has been certified by the developer to meet Apple
performance standards. Apple is not responsible for the operation of this device or its compliance with safety
and regulatory standards.
Please note that the use of this accessory with an Apple product may affect wireless performance.
5
Large Square Baler Power Cable and Main Wiring Harness Installation
1. Locate the tractor power/communication harness (006-6650TM(E)) to the battery and communication
lead to the ISOBUS plug.
2. Connect the red power wire with the 50 amp fuse to the positive side of the battery (12 volt).
a. The power harness must be connected to the battery! The unit will draw more amps than
convenience outlets can handle. Any modifications of the power harness will void systems
warranty. IF MODIFICATIONS ARE REQUIRED CONTACT HARVEST TEC FIRST!
b. This unit will not function on positive ground tractors.
c. If the unit loses power while operating it will not keep track of accumulated pounds of
product used and bale records.
3. Connect the black ground wire to frame of tractor or negative side of battery (12 volt).
4. Connect the iPad Integration Control (030-6672C) to Communication Harness (006-6650TM(E)) in
place of the ISO adapter (shown below) and connect the keyed power wire to a keyed power source.
*Claas 3200-3400 balers will have star wheel assembly 030-4642 for mounting on side of bale chamber
Optional Port
Data
Transfer
iPad Integration Control
030-6672C
Moisture/Bale
Rate Harness
006-7303H(E)
Proximity Sensor (2X)
006-7303S
Star Wheel
Assembly (x2)
030-4641
or
*030-4642
End of Bale Sensor
006-7400
Power/Comm Harness on Baler
006-6650LS2(E)
Power/Comm Harness on Tractor
006-6650TM(E)
Orange Wires
to Keyed Power
006-5650K
Terminating Resistor
006-5650Z
Pump Controller Harness
006-5650FM(E)
Flow Meter
006-4725A
Pump Harness
006-4660Z
Pump Controller
006-5672
*Note: (E) indication is
used for International
Dealers
6
Round Baler Power Cable and Main Wiring Harness Installation
1. Locate the tractor power/communication harness (006-6650TM(E)).
2. On the back of the tractor run the power leads of the power / communication harness (006-6650TM(E))
to battery and the communication lead to ISOBUS plug.
3. Connect the red power wire with the 50 amp fuse to the positive side of the battery (12 volt).
A. The power harness must be connected to the battery! The unit will draw more amps than
convenience outlets can handle. Any modifications of the power harness will void systems
warranty. CONTACT HARVEST TEC IF MODIFICATION IS REQUIRED!
B. This unit will not function on positive ground tractors.
C. If the unit loses power while operating it will not record accumulated product used.
4. Connect the baler power and communication harness (006-6650LS) to the power port on the DCP and
to the display port on the DCP.
5. Connect the iPad integration Control (030-6672C) to Communication Harness (006-6650TM(E)) in
place of the ISO adapter (shown below) and connect the keyed power wire to a keyed power source.
6. Connect the orange wires and attach the plug to the tractor’s ISOBUS port.
7. Connect Flow Meter (006-4725A) and pump harness (006-4660Z) to the Pump Controller.
8. Install one terminating resistor to the pump controller (006-5650Z).
9. Attach moisture cable (006-4640G2) to the DCP
Dual Channel
Processor
(DCP)
006-6671RB
Optional Port
Data
Transfer
Flow Meter
006-4725A
Pump Controller
006-6672
Pump Controller
Harness
006-5650FM(E)
Pump Harness
006-4660Z
Moisture Disc (2X)
006-4641H
RB MC% Harness
006-4640G2
Power/Comm Harness on Baler
006-6650LS(E)
Power/Comm Harness on Tractor
006-6650TM(E)
End of Bale Sensor
006-7400
Terminating Resistor 006-5650Z
Orange Wire to
Keyed Power
006-5650K
iPad Integration Control
030-6672C
*Note: (E) indication is
used for International
Dealers
7
Small Square Baler Power Cable and Main Wiring Harness Installation
1. On the back of the tractor run power leads of the power / communication harness (006-6650TM(E)) to
the battery and communication lead to the ISOBUS plug.
2. Connect the red power wire with the 50 amp fuse to the positive side (12 volt) of the battery.
a. The power harness must be connected to the battery! The unit will draw more amps than
convenience outlets can handle. Any modifications of the power harness will void systems
warranty. IF MODIFICATIONS ARE REQUIRED CONTACT HARVEST TEC FIRST!
b. This unit will not function on positive ground tractors.
c. If the unit loses power while operating it will not keep track of accumulated pounds of
product used and bale records.
3. Connect the black ground wire to frame of tractor or negative side of (12 volt) battery.
4. Connect iPad Integration Control (030-6672C) to Communication Harness (006-6650TM) in place of
the ISO adapter (shown below) and connect the keyed power wire to a keyed power source on tractor.
*Pump Control Harnesses 650 & 645 Models 006-5650FC(E) | 651 Model 006-5650F2M(E)
SYSTEM WIRING DIAGRAM
Dual Channel
Processor (DCP)
006-6671SS
Data
Transfer
Moisture/Bale
Rate Harness
006-7303H(E)
Proximity Sensor (2X)
006-7303S
or 006-5650FC
Optional
Port
Star Wheel Assembly
030-4642 (2X)
End of Bale Sensor and Stroke Counter
006-7400
Power/Comm Harness on Baler
006-6650LS2(E)
Power/Comm Harness on Tractor
006-6650TM(E)
Terminating Resistor
006-5650Z
Pump Controller Harness
006-5650F2M(E)
Flow Meter
H6-4725A
Pump Harness
006-4660Z
Pump Controller
006-5672
Orange Wire to
Keyed Power
006-5650K
*Note: (E) indication is
used for International
Dealers
iPad Integration Control
030-6672C
8
Operation General Operation of SS, RB, LS Balers
Turn On / Off iPad using the Sleep/Wake button
*(Info from Apple User’s Guide)
Turn iPad on. Hold down the Sleep/Wake button until Apple logo appears. iPad will take a moment to load.
You can lock iPad and put it to sleep when you’re not using it. Locking
iPad puts the display to sleep, saves the battery, and prevents
anything from happening if you touch the screen.
When you are not going to use the iPad for an extended period of time put the unit into sleep mode by pressing
the Sleep/Wake button. Press Sleep/Wake button to wake iPad and then unlock iPad by entering passcode.
Turn iPad off. Hold down the Sleep/Wake button for a few seconds until the slider appears onscreen, then drag
the slider to the right.
Downloading Harvest Tec App
1. If iPad does not have Wi-Fi turned on, select the Settings tab then select the Wi-Fi tab (below).
4. Select an available network when detected by the iPad, shown in area above that currently says ‘Other.’
5. Select App Store icon (below) and open. *You will need a Wi-Fi connection available to view App Store.
Download the Hay App in the App Store by searching for
‘Hay App’ in the search bar in the top right corner of screen (right):
*The advertisements displayed on the App Store screen will change.
The app will have the icon as shown:
Note: Made for iPad® running the current iOS operating system
or one version previous required for iPad option
Hay App
Sleep/Wake
Button
2. Turn Wi-Fi on by sliding button to the right.
*Green bar indicates ON
3. Use same process to turn on Bluetooth function
**The Harvest Tec system WILL NOT
appear under the Bluetooth tab in the
Setting App. Open the Hay App to
connect.
9
Shutting Down the Hay App
1. To shut down the Hay App double click the home button (Figure A). This will show the open apps that
are running on your iPad (Figure B).
*Note: By pressing the home button one time to return to the home screen, the Hay App does not shut
down. The system will however, stop applying preservative after 10 seconds.
2. Slide the app you want to shut down by sliding the app toward the top of the iPad, until the app is no
longer visible (Figure C).
Figure A
Figure B
Figure C
10
Operating the Harvest Tec iPad App (continued)
When ready to operate your applicator system, open the Hay App on the iPad by selecting the Hay App icon.
Device Selection
The app will open to the Device Menu screen as shown below.
Pre-2020 applicators which are equipped with the Bluetooth receiver (030-6672B) that are within range (20’) of
the iPad and have power going to them, will be shown under the Active Connections section (below) after the
initial startup of the system (35-45 seconds).
Production year 2020 applicator systems and beyond will include the iPad Integration Module 030-6672C.
When plugging in the iPad cord to the module the app will change to the applicator Main Menu for immediate
operation. Unplug the cord to return to the Device Menu page.
*Hay App version must be at least 2.5.18 (or higher) to operate with the iPad Integration Module (030-6672C)
The In-Active Connections section will show applicator systems that have been connected in the past, but are
not within range of the iPad or do not currently have power going to them (bottom left).
To remove a baler from the In-Active list, slide the bar displaying the baler name to the left, and select the
Delete button that will appear (bottom right).
After the iPad connects to
the Bluetooth receiver,
select the applicator you
want to connect with.
11
Operating the Harvest Tec iPad App (continued)
Demo Mode
Selecting the 300 Demo or 600 Demo button (below) will allow you to view the different screens of the
applicator without requiring connection to an applicator system.
*This function is intended to be used as a visual aid, no values will be displayed.
Manual Selection
Selecting the Manual button (below) displayed to the right of the baler name will open the operation manual for
your baler.
*Use the following information for Large Square Balers.
*You do not need to be connected to a baler to open the manual after a baler has been connected.
When finished reviewing the manual, press the Done button in the top left corner to return to the Device Menu.
Recommended Preservative
To view recommended preservative information, application rates, and frequently asked preservative
questions, select Recommended Preservative (below).
*You do not need to be connected to a baler to open the recommended preservative page.
12
Operating the Harvest Tec iPad App (continued)
Tab Descriptions
Automatic Mode: This mode allows you to use all of the applicator features such as adjusting preservative
application on the go and counting total pounds of product used.
Manual Mode: Allows operator to manually turn pumps on and off. This mode also has moisture content
displayed. Use this mode to prime pumps.
Software Versions: Selecting this tab will display the software currently installed.
Setup Mode: This mode allows the operator to adjust bale rate, application rate settings and select tip output.
Job Records: Keep track of up to 300 jobs with total product used, average moisture content, tons baled, and
baling date.
13
Screen Menus
Use the screen shots below to navigate through the operation screens.
Automatic Mode
Manual Mode
Operation Note:
Pressing the Home Button on the iPad WILL NOT immediately stop application of the System (see below):
Select or to stop application
*To close app see the Shutting Down Hay App Section
**When the app is not displayed for 10 seconds,
preservative application will stop.
Bluetooth Connection Indicator
Green
-DCP is connected
Yellow
-DCP connecting
Red
-DCP not connected
Bluetooth Connection Indicator
Green
-DCP is connected
Yellow
-DCP connecting
Red
-DCP not connected
X
-Pump is OFF
-Pump is ON
14
Setup Mode Large Square Balers
*Only used if equipped with Tagger
Turn Tagger ON by selecting the X
Indicates tagger is ON
*If RFV Equipped, additional options
will appear on Bale ID Screen (next)
If using RFV Spray Module,
turn ON by selecting the X
Indicates Spray Module is ON
Make sure Knotter/Dye Tip Distance is
correct
Select correct distance
15
Setup Mode Large Square Baler (continued)
*Select X to turn on options shown
Indicates Crop Eyes are ON
*Only used if equipped with GPS
*Select grey area to change
*Select appropriate GPS unit
*Adjust alarm setting and turn on pump
module by selecting X in grey area
indicates Pump Module is on
Select correct tip setting
*High tips are installed from factory
Press OK if correct tip output
has been selected
16
Setup Mode Large Square Baler (continued)
*Select correct bale weight, length,
and time per bale information
*Turn on Bale Rate sensor,
Green bar indicates sensors are ON
*Ensure all baler sensors are turned OFF
*If using a scale kit, turn sensor ON
17
Setup Mode Large Square Baler (If RFV Equipped)
*Select correct bale weight, length,
and time per bale inforation
*Turn on Bale Rate sensor,
Green bar indicates sensors are ON
*Select correct bale size
Software Versions
18
Setup Mode Round Baler
If using a fixed chamber baler,
select the X to turn on
Adjust the moisture default to the
moisture of the last bale reading
*Select X to turn on options shown
Indicates Crop Eyes are ON
Adjust moisture alarm to desired level
Select desired alarm moisture
Adjust bale weight information
Select desired bale weight
19
Setup Mode Small Square
Turn on Stroke Counter by selecting the X,
Adjust min/max by selecting number areas
Scroll up or down to correct min/max
Indicates Stroke Counter is ON
Select X to turn on options shown
Indicates Crop Eyes are ON
Only used if equipped with GPS
Select grey area to change
Select appropriate GPS unit
Adjust alarm setting by selecting
the grey area
Select desired alarm setting by
scrolling up or down
Input correct weight, length,
time per bale
Select correct weight
20
Job Records Large Square Balers
Type desired Field Name, select Create Job
*When RFV Equipped, Average RFV, Ave
TDN/CA90% info will be added
For Bale details select Bale Button
Use arrows to change jobs shown
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Harvest TEC 6672C User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI