ADTRAN TOTAL ACCESS 3000 SHDSL V.35 LTU User manual

Type
User manual

This manual is also suitable for

TOTAL ACCESS
®
3000 SHDSL V.35 LTU
DEFAULT PROVISIONING OPTIONS
FRONT PANEL LED INDICATORS
PWR Off No power
Green Self-test passed and the module is In Service
Yellow Self-test passed and the module is Out of Service
SHDSL Off SHDSL Loop is Out of Service -- Unassigned
Green SHDSL Loop is trained
Red SHDSL Loop is not trained
G.703 Off G.703 port is not configured, Out of Service -- Unassigned, or in alarm
condition
Green G.703 port configured and no alarms
Nx64k Off Service is not configured or in alarm condition
Green Service is configured and operating normally
RTS Off Nx64k service not configured or RTS control line is OFF
Green RTS control line is ON
RLSD Off Nx64k service not configured or RLSD control line is OFF
Green RLSD control line is ON
TST Off Module is not in loopback or BERT
Green Local loopback is active, or BERT running with no errors
Blinking Yellow Module is running a BERT with bit errors
Red BERT running with no pattern sync
ALM Off No alarm condition detected
Yellow Remote alarm condition detected
Red Alarm condition detected locally
V.35 PORT PIN ASSIGNMENTS
INTERFACE CONNECTIONS
The G.703 signal is transmitted to the network either via the Total Access 3000 backplane connectors or
the two BNC connectors mounted on the faceplate. The G.703 signal and the SHDSL signal use the
following backplane amphenol connector Pairs:
SHDSL - Pair 2
G.703 Tx - Pair 8
G.703 Rx- Pair 7
TOTAL ACCESS
3000 SHDSL
V.35 LTU
SHDSL
1182008L5
PWR
SHDSL
G.703
Nx64K
RTS
RLSD
TST
ALM
G.703
N
x
6
4
K
RX
TX
C A U T I O N C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
JOBAID
61182008L5-22A
0202
For a complete Installation and Maintenance faxback: (877) 457-5007, Document #766. Please have your fax number available.
V.35 Port
Circuit No. Circuit Name To/From DCE Pinout (A/B)
102 Signal Ground B
103 Transmit Data To P/S
104 Receive Data From R/T
105 Request To Send To C
106 Clear To Send From D
107 Data Set Ready From E
108/2 Data Terminal Ready To H
109 Received Line Signal Detect From F
113 Transmit Signal Element Timing To U/W
114 Transmit Signal Element Timing From Y/AA
115 Receive Signal Element Timing From V/X
140 Remote Loopback To N
141 Local Loopback To L
142 Test Indicator From NN
Provisioning Options Default
Unit Options
Cross-Connect Map All Idle
Local Management Disabled, Enabled Enabled
LT Mode Clk Source Internal Clock Internal Clock
Nx64 ETC
G.703 RX Clock
NTU Auto Provisioning Disabled, Enabled Disabled
External Port Alarms Disabled, Enabled Enabled
Line Card Service State In Service Out of Service - Unassigned
Out of Service - Maintenance
Out of Service - Unassigned
G.703 Port Service State In Service Out of Service - Unassigned
Out of Service - Maintenance
Out of Service - Unassigned
Nx64K Port Service State In Service Out of Service - Unassigned
Out of Service - Maintenance
Out of Service - Unassigned
SHDSL Options
Rate (Kbps) Enter a new value for N from 3 to 36, 2056 (N=32)
where Rate(Kbps)=(N x 64) + 8:
SNR Margin Alarm Threshold(dB) Disabled, Enabled Disabled
Loop Attenuation Alarm Threshold (dB) Disabled, Enabled Disabled
Test Options
Loopback Timeout(Min) Disabled, Enabled Disabled
BERT Test Pattern All Zeros 2e15-1
All Ones
2e15-1
2e23-1 2e15-1
BERT Test Pattern Polarity Normal, Inverted Normal
Nx64K In-band Pattern Detection Disabled, Enabled Disabled
COMPLIANCE
Caution: Up to -200 VDC may be present on telecommunications wiring.
This product is intended for installation in restricted access locations only and in
equipment with a Type “B” or “E” enclosure.
Code Input Output
Power Code (PC) F C
Telecommunication Code (TC) X
Installation Code (IC) A
PRICING AND AVAILABILITY 800.827.0807
TECHNICAL SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
www.adtran.com
61182008L5-22A
TOTAL ACCESS 3000 SHDSL V.35 LTU MENU TREE
1. Unit Information
SHDSL V.35 LTU
Main
Menu
SHDSL Version
Vendor List Number
Vendor Issue Number
Vendor Software Version
Unit Identification Code (CLEI)
Vendor ID
Vendor Model Number
Vendor Serial Number
Manufacture Date
PROM Checksum
2. Provisioning
3. Status
4. Test
1. Cross-Connect Map
2. Restore Factory Defaults
3. Local Management
4. LT Mode Clk Source
5. Circuit ID
6. Software Update
7. Change Password
9. Line Card Service State
10. G.703 Port Service State
8. NTU Auto Provisioning
11. External Port Alarms
12. Nx64K Port Service State
1. ISDN-PRA V3
2. G.704 CRC-4 Multiframing
3. G.704 Idle Pattern
4. Customer Spare Bits Insertion
5. Customer Spare Bits Pattern
6. Network Spare Bits Insertion
7. Network Spare Bits Pattern
9. Network E-bit Generation
8. Network RAI Generation
1. Tx Clock Source
2. Tx Clock Polarity
3. RTS (Circuit 105)
4. CTS (Circuit 106)
5. RTS to CTS Delay (ms)
6. DSR (Circuit 107)
7. DTR (Circuit 108/2)
8. RLSD (Circuit 109)
1. Dual Sided
2. Custom Transparent
3. Customer Non-Transparent
4. Network Transparent
5. Network Non-Transparent
6. Off
RAM/ROM Power-on Self Test
1. SHDSL Local Loopback
2. SHDSL Remote Loopback
3. SHDSL BERT
4. G.703 Local Loopback
5. G.703 BERT
6. Nx64K Local Loopback
7. Nx64K BERT
1. LTU SHDSL Port
2. LTU G.703 Port
4. NTU SHDSL Port
3. NTU Nx64k Port
1. LTU
2. NTU
1. Local
2. Remote
1. LTU SHDSL
2. LTU G.703
3. SHDSL PM Thresholds
1. Rate (kbps)
2. SNR Margin Alarm Threshold (dB)
3. Loop Attenuation Alarm Threshold (dB)
5. Performance History
6. Terminal Mode
1. Unit Options
2. SHDSL Options
4. Nx64K Options
3. G.703 Options
5. Test Options
General Status
Aggregate Rate (kbps)
SNR Margin (dB) (Cur/Min/Max)
Loop Attenuation (dB) (Cur/Min/Max)
Errored Seconds (ES)
Severely Errored Seconds (SES)
Unavailable Seconds (UAS)
Code Violations Count (CVC)
LOSW Seconds (LOSWS)
Loopback Status
BERT Status
Alarms
SHDSL Version
Vendor List Number
Vendor Issue Number
Vendor Software Version
Unit Identification Code (CLEI)
Vendor ID
Vendor Model Number
Vendor Serial Number
Other Vendor Information
1. Loopback Timeout (Min)
2. BERT Test Pattern Polarity
3. BERT Test Pattern Polarity
4. Nx64K Inband Pattern Detection
5. RL (Circuit 140)
6. LL (Circuit 141)
7. TI (Circuit 142)
WARRANTY
Warranty for Carrier Networks products manufactured by ADTRAN and supplied under Buyers order for international use is five (5) years. For a complete copy of ADTRAN’s International Equipment Warranty, document number
60000003#I-3: (877) 457-5007, Document #583.
SHDSL MENU OPTIONS
The Total Access 3000 SHDSL V.35 Menus can be provisioned only through the Total Access 3000 System Controller Unit (SCU), P/N 1181018L1. These options are accessed via the local terminal or remote access via the 10BaseT or TL1
interfaces. Connect a terminal emulator via the RS-232 (DB-9) connector on the faceplate of the SCU. The terminal must be VT100 or compatible and set for 9600 bps, 8 data bits, no parity, 1 stop bit. At the LOGIN screen, enter the
account name and system password. Select ACCESS MODULES from the Total Access Menu. Access the desired SHDSL module by selecting the corresponding slot number.
  • Page 1 1
  • Page 2 2