freeView Power 80 User Manual
1
TABLE OF CONTENTS
1 GENERAL INFORMATION..................................................................................................................2
1.1 OVERVIEW......................................................................................................................................2
1.2 SAFETY INSTRUCTIONS....................................................................................................................2
1.3 PACKAGE CONTENTS.......................................................................................................................2
1.4 FEATURES ......................................................................................................................................3
2 INSTALLATION....................................................................................................................................4
2.1 INSTALLATION TIPS..........................................................................................................................4
2.2 NETWORK DIAGRAM........................................................................................................................4
2.3 MOUNTING IN A RACK ......................................................................................................................4
2.4 EXTERNAL COMPONENTS ................................................................................................................5
2.5 OPTIONAL MODULES .......................................................................................................................6
3 DAISY CHAINING................................................................................................................................8
3.1 DAISY CHAINING .............................................................................................................................8
4 MANAGING THE DEVICE.................................................................................................................10
4.1 SNMPIV......................................................................................................................................10
4.1.1 INSTALLING THE SOFTWARE .................................................................................................10
4.1.2 USING THE SOFTWARE ........................................................................................................10
4.2 WEB INTERFACE............................................................................................................................13
4.2.1 MAIN MENU.........................................................................................................................13
4.2.2 SYSTEM STATUS..................................................................................................................15
4.2.3 RPM STATUS ......................................................................................................................16
4.2.4 NETWORK...........................................................................................................................17
4.2.5 SNMP................................................................................................................................19
4.2.6 EMAIL .................................................................................................................................21
4.2.7 PPP...................................................................................................................................22
4.2.8 WEB/TELNET ......................................................................................................................23
4.2.9 SYSTEM TIME......................................................................................................................23
4.2.10 RPM SETTING ....................................................................................................................24
4.2.11 RPM ACTION ......................................................................................................................26
4.2.12 RPM SCHEDULE .................................................................................................................27
4.2.13 SAVE/RESTORE SETTINGS...................................................................................................28
4.2.14 EVENT LOG.........................................................................................................................28
4.2.15 SAVE EVENT LOG................................................................................................................29
4.3 TELNET.........................................................................................................................................29
4.4 TELEPHONE ACCESS .....................................................................................................................31
4.4.1 LOGGING IN.........................................................................................................................32
4.4.2 MANAGING POWER PORTS ..................................................................................................32
4.4.3 CHANGING THE PASSWORD..................................................................................................33
4.4.4 RECOVERING THE PASSWORD..............................................................................................33
4.4.5 TELEPHONE PASS-THROUGH................................................................................................33
5 SPECIFICATIONS..............................................................................................................................34
5.1 PRODUCT SPECIFICATIONS ............................................................................................................34
2
1 General Information
1.1 Overview
The freeView Power 80 allows you to remotely control the AC power for up to eight devices
including servers, routers, modems and telephone networks. With the ability to stack up to 16
units together, up to 128 devices can be controlled from a single interface.
The freeView Power 80 supports several methods to log in remotely. The main method is to
access the unit via IP over the LAN or the internet. This method provides the user with a web-
based interface that is fast and easy to use. An alternative is to connect a modem to the unit’s
RS-232 port and access the device via dial-up modem. This method will also allow the user to
control the unit using a web interface. The last method can be used if a computer is not
available to access the freeView Power 80. Using the built-in telephone ports, the network
administrator can access the device by dialing into it from a touch-tone telephone and control it
using commands entered through the phone.
1.2 Safety Instructions
If one of the following situations arises, the equipment should be checked by service personnel.
The power cord is damaged.
Liquid has leaked into the equipment.
The equipment has been exposed to excessive moisture.
The equipment does not work properly and you can not get it to work after reading this
manual.
The equipment has been dropped and damaged.
The equipment shows obvious signs of damage.
1.3 Package Contents
The complete freeView Power 80 package consists of:
freeView Power 80 unit
AC Power Cord
RJ-11 Daisy Chain Cable
Eight (8) RJ-11 to RS-232 Cables
Screws and Mounting Brackets
User Manual and Management Software CD
Ensure that the unit was not damaged during shipping. If you encounter a problem, please
contact your dealer.
Read this manual thoroughly, and follow the installation and operation procedures carefully to
prevent any damage to the product and/or any of the devices connected to it.
freeView Power 80 User Manual
3
1.4 Features
The following are the main features for the freeView Power 80:
Turn any AC powered device on or off via IP network and phone.
Support turning on or off connected equipment manually using push buttons on the device.
Integrated 10/100BASE-T Ethernet port for connection to a TCP/IP network.
IP Address filtering prevent unauthorized computers from accessing the web interface
through the network.
Supports NMS to control RPM through MIB. User also can use MIB to develop their
application interface.
Download data and events log list to server.
Daisy Chain expandable up to 16 units.
When events occur, RPM can notify user by email and trap according to the pre-set
conditions.
Allows users to configure the sequence in which power is turned on or off for each outlet.
This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped
loads. Sequencing also allows users to predetermine which piece of equipment is turned on
first so other equipment dependant on that unit will function properly.
Customize and schedule to turn on or off the connected equipment.
4
2 Installation
2.1 Installation Tips
When installing the freeView Power 80, keep the following points in mind:
Install the unit in a cool and dry place. Refer to the specifications for details on permissible
temperature and humidity ranges.
Install the unit in a location free from electromagnetic interference, vibrations, dust, and
direct exposure to sunlight.
Leave at least 4” (10 cm) of space at the front and rear of the unit for ventilation.
Install the unit on a strong, sturdy surface that can support its weight, or in an EIA standard-
size rack.
2.2 Network Diagram
Figure 1 shows an example of how to install the freeView Power 80 in a network.
Figure 1 – Sample Network Diagram
2.3 Mounting in a Rack
The freeView Power 80 can be mounted in an EIA standard-size, 19-inch rack, which can be
placed in a wiring closet along with other equipment. Attach the one mounting bracket to each
side of the unit, and secure them with the screws provided.
Once the brackets are attached, align the holes in the bracket with those in the rack, and use
the screws provided to install the unit into the rack.
freeView Power 80 User Manual
5
2.4 External Components
The following diagrams show the front and rear panels of the freeView Power 80 (Figures 2 and
3).
Figure 2 – Front Panel
Figure 3 – Rear Panel
Phone Control Port
Connecting the freeView Power 80 to an analog telephone port will allow the device to be
controlled by dialing the telephone number associated with the phone port. The second
telephone port is used to connect an analog telephone to so calls can still be made out using
that line.
Daisy Chain Link Port
Up to 8 units can be stacked together using the provided RJ-11 daisy chain cables.
Daisy Chain LED (Yellow)
For units that are stacked together, the Daisy Chain LED indicates the ID of the current unit.
The master unit will have all LEDs off.
Power LED (Red)
The LED will be on when the receptacle is receiving power.
The LED will be off when the receptacle is not receiving power.
The LED will flash when there is a problem with the receptacle.
6
Manual Switches
The manual switches (A through H) are associated to the corresponding outlets in the back of
the unit. Pressing and holding the button for three seconds will toggle the state between remote
management (through the web and telnet interfaces) and local management. If a port is set to
local management, pressing the button will turn the port on or off.
Remote Control LED (Green)
The LED will be on when the receptacle is configured for remote management.
The LED will be off when the receptacle is configured for local management.
Circuit Breaker
In the event of a power surge or other disruption in the power being supplied to the device, the
circuit breaker will trip, causing the unit and all devices plugged into the unit to be turned off. If
this happens, turn off the unit and check the circuit to ensure that it is free of any shorts or other
problems which may cause another power surge before pressing the circuit breaker button and
turning the unit back on.
Communication Ports
The freeView Power 80 can instruct computers connected to the communication ports to shut
down before power is cut off to the device.
2.5 Optional Modules
The freeView Power 80 includes a freeView Power M1 module (Figure 4) which supports IP
access to the unit. The freeView Power 80 also supports the freeView Power M2 module which
supports IP access, modem access, and environment monitoring (Figure 5).
Figure 4 – freeView Power M1
Figure 5 – freeView Power M2
The following tables describe the functions of the LEDs on both modules.
freeView Power M1
LED Color Condition Description
Green Power state On: Normal power
Red Connection state with device
Flashing: Connected to
incorrect device
freeView Power 80 User Manual
7
freeView Power M2
Yellow Red Green Description
Off Off On Power on
Flashing On On System initializing
On Off On Normal operation
On Flashing On Connected to incorrect device
Flashing Flashing On Writing data to flash memory
LAN Port LED
LED Color Description
Green
On: LAN connection speed is 100M
Flashing: Data transmitting
Yellow
On: LAN connection speed is 10M
Flashing: Data transmitting
8
3 Daisy Chaining
3.1 Daisy Chaining
Up to sixteen units of the freeView Power 80 can be daisy chained to provide up to 128
managed power outlets. Each unit in the chain must be assigned a unique identification
number. The default ID is 0. The following procedure explains how to daisy chain multiple units
together:
1. Make sure that the Terminator is plugged into the first unit’s iLink port (Figure 6).
2. Plug in the first unit and turn it on.
3. Change the first unit’s ID number to “1” by logging into the web GUI, then going to the RPM
Setting menu, then selecting “01” beside “Address Change” then click “Apply” (See section
4.2.10 for details). Each unit that is configured must have its own unique ID, (the default ID
is "0"). After changing the unit’s ID number, you will see the LED beside the number 1 light
up on the front panel of the first unit.
Figure 6 – First Unit with Terminator in leftmost iLink Port
4. Make sure that the Terminator is plugged into the second unit’s iLink port (Figure 7).
5. Remove the Ethernet module from the second unit.
6. Connect the first and second RPM together with an iLink cable.
7. Plug in the second unit and turn it on.
8. Configure the second unit’s ID number to “2” by logging into the web GUI, going to the RPM
Setting menu, select “RPM00” under Select RPM, then select “02” beside “Address Change”
then click “Apply”. After changing the unit’s ID number, you will see the LED beside the
number 2 light up on the front panel of the second unit.
Figure 7 – First and Second Unit Connected with iLink Cable
9. For configurations with two units, the setup is now complete. For configurations with more
units, proceed with the following steps.
10. Remove the Terminator for the second unit.
11. Make sure that the Terminator is plugged into the third unit’s iLink port (Figure 8).
12. Remove the Ethernet module from the third unit.
13. Connect the second and third RPM together with an iLink cable.
14. Plug in the third unit and turn it on.
freeView Power 80 User Manual
9
15. Configure the third unit’s ID number to “3” by logging into the web GUI, going to the RPM
Setting menu, select “RPM00” under Select RPM, then select “03” beside “Address Change”
then click “Apply”. After changing the unit’s ID number, you will see the LED beside the
number 3 light up on the front panel of the third unit.
Figure 8 - First Three Units Connected with iLink Cable
For configurations with more than three units, repeat steps 10-15 for the remaining units.
10
4 Managing the Device
4.1 SNMPIV
The included SNMPIV software allows you to perform maintenance on the device even if you do
not know the IP address of the unit. The SNMPIV software also includes a standard MIB which
allows the unit to be monitored with third-party network management software.
4.1.1 Installing the Software
To install the software, follow these steps:
1. Insert the CD included in the box in your CD-ROM drive.
2. Open Windows Explorer and browse to the CD-ROM drive.
3. Double-click on the file “SNMP Utility.exe”.
4. Follow the instructions displayed on the screen to install the software.
5. After completing the installation, the software can be started by going to Start Menu Æ All
Programs Æ SNMP Utility Æ SNMP Utility (Figure 9).
Figure 9 – Windows Start Menu
4.1.2 Using the Software
The menu is located on the left side of the window. The table on the right side of the window
shows all freeView Power 80 devices on the network (Figure 10).
Figure 10 – SNMP Utility
Network Selection
When the software first starts, it will prompt you to select the network interface to use. To
change the network interface to use, click “Network Selection” to display a list of available
network interfaces (Figure 11), and select the one to use. All devices must be on the same
network as the computer in order to be detected by the software.
freeView Power 80 User Manual
11
Figure 11 – Network Selection
Network Selection
By default, the software will automatically select a network interface card to use (wired or
wireless). To change the network interface to use, click “Network Selection” to display a list of
available network interfaces (Figure 11), and select the one to use. All devices must be on the
same network as the computer in order to be detected by the software.
Configure
The “Configure” button allows you to configure a freeView Power 80 unit selected from the list
on the right side of the window. The first tab to be displayed is the “IP Address” tab (Figure 12).
On this tab, you can set the IP address of the device dynamically using DHCP, given through
BOOTP, or statically by manually entering the information in the window.
Figure 12 – IP Address Tab
After setting the IP address of the device, you can access the web interface or telnet interface of
the unit from any computer on the same network as the device.
The second tab is the “Advanced” tab (Figure 13). This tab allows you to set a password for
accessing the freeView Power 80 device from the SNMPIV software (this does not affect the
12
web or telnet interface passwords). To set a password, enter the password into the “New
password” field, and enter it again in the “Confirm password” field, and click “OK”. Remember to
keep a record of this password, as it cannot be recovered if lost.
Figure 13 – Advanced Tab
On this tab, you can also set the ports used by the device for HTTP (web) and telnet access.
You can also disable web and/or telnet access altogether by unchecking the boxes next to the
applicable interface. If you change a port from the default port, you will have to enter the full IP
address and port in order to access to the device. For example, if you change the HTTP port
from 80 to 81, you must enter “http://192.168.0.5:81” to access the web interface of the device.
Download Firmware
The software offers a convenient method of upgrading the firmware on a device. To upgrade
the firmware on a device, select the device from the list, and click “Download Firmware”. In the
new window (Figure 14), enter the path and name of the firmware file or click “…” to browse for
the file. The file should end in “.bin”. Click “Start”. During the upgrade, the freeView Power 80’s
Red and Yellow LED will flash alternately. After the upgrade has been completed, the unit will
reboot automatically.
Note: In the event the firmware upgrade is interrupted (e.g. due to a power
failure), the unit will revert to the old firmware version. Performing the upgrade
again will load the new firmware onto the unit.
Figure 14 – Firmware Download
freeView Power 80 User Manual
13
Refresh
Click the “Refresh” button to search the network for freeView Power 80 devices.
4.2 Web Interface
To access the web interface of the freeView Power 80, follow these steps:
1. Open a web browser (Internet Explorer 6.0 or higher is recommended).
2. Enter the IP address of the unit into the address bar (e.g. “http://192.168.0.5”)
3. On the login screen, enter the user name and password (Figure 15). By default, both fields
are blank. It is recommended that you change the user name and password as soon as
possible for security reasons.
Figure 15 – Login Window
4.2.1 Main Menu
The main menu consists of four categories (Figure 16).
14
Figure 16 – Main Menu
Information: Provides information for the connected devices.
Configuration: Allows for configuration of the network and devices settings.
Log Information: Displays the log of events that occurred on the device.
Device selection: Not currently used.
Each category consists of different pages which are described in detail in the following sections.
freeView Power 80 User Manual
15
4.2.2 System Status
The System Status page (Figure 17) displays the details of the system along with current
network configuration settings.
Figure 17 – System Status Page
Firmware Version: Current version of firmware on the unit.
Device Number: Unique identifier for the unit.
System Name: The name given to the unit for identification purposes – used with SNMP.
System Contact: The name of the person to contact in case there are problems with the unit –
used with SNMP.
Location: The location of the unit – used with SNMP.
System Time: The local time on the device.
Uptime: The amount of time the unit has been running.
MAC Address: The MAC address of the unit.
The remaining items will be explained in the following sections.
16
4.2.3 RPM Status
The RPM Status page (Figure 18) displays the current status of all of the power outlets, and
allows you to turn outlets on and off.
Figure 18 – RPM Status Page
If a power outlet is off, clicking on the icon to the right of the outlet will turn it on. If a power outlet
is on, clicking on the icon to the right of the outlet will turn it off. Clicking the icon beside “All On”
will turn all of the outlets on. Clicking the icon beside “All Off” will turn all of the outlets off.
Outlets labeled as “non-internet” cannot be controlled from the web interface and will not be
affected by the “All On” and “All Off” buttons.
If there are multiple units in a stack, select the unit to control under “Select RPM”. The yellow
LED on the front panel of the device indicates its ID number in the stack.
freeView Power 80 User Manual
17
4.2.4 Network
The Network page (Figure 19) allows you to change the network settings of the device.
Figure 19 – Network Page
IP Address: The IP address of the unit used for web and telnet access.
Subnet Mask: The subnet mask of the unit.
Gateway: The gateway of the unit, required for accessing external mail servers for email
notifications.
18
Obtain an IP Address: Select whether the unit uses the IP address entered manually in the
fields above, or obtains an IP address from a DHCP server.
Primary DNS Server: The primary DNS server used for name resolution.
Secondary DNS Server: The backup DNS server used for name resolution in the event the
primary DNS server is unavailable.
Connection Type: Determine the connection speed and duplex of the Ethernet port (Auso
Sense, 10Mbps Half-Duplex, 10Mbps Full-Duplex, 100Mbps Half-Duplex, 100Mbps Full-
Duplex). The recommended settings is “Auto Sense”.
Services Provider: The dynamic DNS service provider used (None, 3322.org, dhs.org,
dyndns.org, myddns.com).
Domain Name: Your registered DDNS domain name.
Login Name: The DDNS account login name.
Login Password: The DDNS account login password.
Use External STUN server to get Public IP to register: Set whether a STUN server should be
used to retrieve the public IP address of the device.
Primary STUN Server IP: If a STUN server is used, this is the primary IP address of the STUN
server.
Secondary STUN Server IP: If a STUN server is used, this is the secondary IP address of the
STUN server in the event the primary server is unavailable.
When Connection should be made: Determine when the unit should connect to a PPPoE
internet connection (Disabled, Connect Always).
Login Name: The login name for the PPPoE account.
Login Password: The login password for the PPPoE account.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

Freedom9 80 User manual

Category
Power supply units
Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI