WaterWay 810-0137 User manual

Type
User manual
RIVER JET INSTALLATION INSTRUCTIONS
8" Wide Eyeball
Eyeball turrets up / down 20%
Vent Enhancement System
Extra Large 2 ½" S intake
Up to 1000 GPM input at 13 PSI
Part No. Description
210-5100 2 ½" S x 1" Spigot
210-5100 2 ½" S x 1" Spigot Stainless Steel
2-Speed motor for increased efficiency
56-frame motor for added strength, cooler
operating temperature and longer motor life
Large 2 ½" intake for improved flow
performance and reduced noise
Large 8" diameter wet end for increased
volume capacity
Thermally protected to extend life
expectancy of motor
Highly versatile wet end can be rotated
every 90°
Part No. Desc. HP Volts Amps
3721621-1T 2-Speed 4 HP 230 Volts 4.4 / 12 Amps
3722021-0T 2-Speed 5 HP 230 Volts 4.8 / 16.4 Amps
3711621-0T 1-Speed 4 HP 230 Volts 12 Amps
3712021-0T 1-Speed 5 HP 230 Volts 16.4 Amps
RIVER JETS
RECOMMENDED: VIPER 56-FRAME PUMP (4 HP MINIMUM)
14.47"
7.47"
4.37"
6.72"
8.36"
1.19"
8.05"
9.08" 8.44"
4.72"
6.45"
1.0"
11"
PRESSURE VERSUS FLOW RATE
Flow Rate (GPM)
50.82 22
46.20 20
41.58 18
36.96 16
32.34 14
27.72 12
23.10 10
18.48 8
9.24 6
23.10 4
4.62 2
0 0
Feet of Head
PSI
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 360 380
5.0 HP
4.0 HP
3.0 HP
810-0137.0618
©2018 Waterway Plastics
2200 East Sturgis Road, Oxnard CA 93030 • Phone 805.981.0262 • Fax 805.981.9403
www.waterwayplastics.com • [email protected]
Designed,
Engineered &
Manufactured
in the USA.
2
RIVER JET PLACEMENT
RIVER JET HOLE SAW CUTOUT SPECIFICATIONS
16" Center to Center 5" Minimum
from Water Level
13-14" Minimum
from Water Level
Water Level
1. River jets should be placed in the following form, two
shoulder jets side by side in a horizontal position. Lower
jet (torso jet) should be placed horizontal in the center
below the shoulder jets (see jet placement diagram).
2. Using a 5 ½" hole saw, drill out 2 holes 7" center to
center. Cut out joining sections to create one oval hole
(see cutout specs for detailed information).
3. Three (3) 4 HP Viper Pumps must be within 10 feet of the
jets for best results.
WARNING: Pumps must be placed in a
flooded system (below water level).
4. Each pump must have a minimum of three (3) 250 GPM
TWM suctions.
5. Each suction line should be a minimum of 2 ½" schedule
40 rigid or flex PVC pipe.
6. Each return line should be a minimum of 2 ½" schedule
40 rigid or flex PVC pipe.
5 ½"
7"
3"
/"
1 ½"
3 ½"
2 /"
With a 5 ½" hole saw, cut out two (2) holes, 7" from center to center. Cut dashed lines with body saw.
810-0137.0618
©2018 Waterway Plastics
WARRANTY
For product registration visit: www.waterwayplastics.com.
For Warranty questions or claims please contact point of purchase.