Lucent Technologies Definity Audix System Installation And Upgrade

Type
Installation And Upgrade
DEFINITY AUDIX System
Release 3.2.4
Installation and Upgrade
585-300-118
Comcode 107894298
Issue 2
December 1996
Copyright 1996, Lucent Technologies
All Rights Reserved
Printed in U.S.A.
Notice
Every effort was made to ensure that the information in this book was
complete and accurate at the time of printing. However, information
is subject to change.
Your Responsibility for Your System’s Security
Toll fraud is the unauthorized use of your telecommunications system
by an unauthorized party, for example, persons other than your com-
pany’s employees, agents, subcontractors, or persons working on your
company’s behalf. Note that there may be a risk of toll fraud associ-
ated with your telecommunications system and, if toll fraud occurs, it
can result in substantial additional charges for your telecommunica-
tions services.
You and your system manager are responsible for the security of your
system, such as programming and configuring your equipment to pre-
vent unauthorized use. The system manager is also responsible for
reading all installation, instruction, and system administration docu-
ments provided with this product in order to fully understand the fea-
tures that can introduce risk of toll fraud and the steps that can be
taken to reduce that risk. Lucent Technologies does not warrant that
this product is immune from or will prevent unauthorized use of com-
mon-carrier telecommunication services or facilities accessed through
or connected to it. Lucent Technologies will not be responsible for
any charges that result from such unauthorized use.
Lucent Technologies Fraud Intervention
If you suspect that you are being victimized by toll fraud and you need
technical support or assistance, call Technical Service Center Toll
Fraud Intervention Hotline at 1 800 643-2353.
Federal Communications Commission Statement
Part 15: Class B Statement. This equipment has been tested and
found to comply with the limits for a Class B digital device, pursuant
to Part 15 of the FCC Rules. These limits are designed to provide rea-
sonable protection against harmful interference in a residential instal-
lation. This equipment generates, uses, and can radiate radio-
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interfer-
ence to radio or television reception, which can be determined by turn-
ing the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
Reorient the receiving television or radio antenna where
this may be done safely.
To the extent possible, relocate the receiver with respect to
the telephone equipment.
Where the telephone equipment requires ac power, plug the
telephone into a different ac outlet so that the telephone
equipment and receiver are on different branch circuits.
Part 68: Network Registration Number. This equipment is regis-
tered with the FCC in accordance with Part 68 of the FCC Rules. It is
identified by FCC registration number AS593M-11185-MF-E.
Part 68: Answer-Supervision Signaling. Allowing this equipment to
be operated in a manner that does not provide proper answer-supervi-
sion signaling is in violation of Part 68 rules. This equipment returns
answer-supervision signals to the public switched network when:
Answered by the called station
Answered by the attendant
Routed to a recorded announcement that can be adminis-
tered by the CPE user
This equipment returns answer-supervision signals on all DID calls
forwarded back to the public switched telephone network.
Permissible exceptions are:
A call is unanswered
A busy tone is received
A reorder tone is received
Trademarks
DEFINITY is a registered trademark of Lucent Technologies in the
U.S. and throughout the world.
AUDIX is a registered trademark of Lucent Technologies.
Ordering Information
Call: Lucent Technologies Publications Center
Voice 1 800 457-1235 International Voice 317 361-5353
Fax 1 800 457-1764 International Fax 317 361-5355
Write: Lucent Technologies Publications Center
P.O. Box 4100
Crawfordsville, IN 47933
Order: Document No. 585-300-118
Comcode 107894198
Issue 2, December 1996
For additional documents, refer to the section entitled, “Related
Resources” inAbout This Book.”
You can be placed on a Standing Order list for this and other docu-
ments you may need. Standing Order will enable you to automatically
receive updated versions of individual documents or document sets,
billed to account information that you provide. For more information
on Standing Orders, or to be put on a list to receive future issues of this
document, please contact the Lucent Technologies Publications Cen-
ter.
Warranty
Lucent Technologies provides a limited warranty on this product.
Refer to the “Limited use Software License Agreement” card provided
with your package.
European Union Declaration of Conformity
Lucent Technologies Business Communications Systems declares
that DEFINITY AUDIX equipment specified in this document con-
forms to the referenced European Union (EU) Directives and Harmo-
nized Standards listed below:
EMC Directive 89/336/EEC
Low Voltage Directive 73/23/EEC
The “CE” mark affixed to the equipment
means that it conforms to the above
Directives.
Acknowledgment
This document was prepared by the Product Documentation Develop-
ment group, Lucent Technologies, Denver, CO and Columbus, OH.
Contents
Issue 2 December 1996 iii
About This Document ix
Overview ix
Intended Audiences ix
Prerequisite Skills and Knowledge ix
Organization of This Document x
How to Use This Document x
Conventions Used in This Document xi
Trademarks and Service Marks xii
Related Resources xii
How to Get Help xii
How to Make Comments About This Document xiii
1 Prerequisites 1-1
Display Set and Control-Link
Integration 1-2
Task 1: Verify the Selected Site 1-2
Task 2: Gather Required Tools 1-3
Task 3: Review Safety Considerations 1-3
Task 4: Verify the Components and Connectivity 1-4
2 Hardware Installation 2-1
Hardware Installation Tasks 2-1
Worksheets Needed 2-2
Task 5: Install the DEFINITY AUDIX System Assembly 2-2
Slot and Carrier Restrictions 2-4
DEFINITY AUDIX System Slots 2-4
Installation Steps 2-5
Task 6: Connect the Alarm Board Cable 2-10
Alarm Origination/Remote Access Connection 2-10
DEFINITY AUDIX Connection 2-11
Contents
iv Issue 2 December 1996
LAN Connection 2-11
Reserved RS-232 Connection 2-13
MFB Port Usage for DS and CL Integration 2-13
Task 7: Install the Terminals 2-13
Task 7A: Install a Terminal via a Direct Connection 2-14
Task 7B: Install a Terminal via Modems 2-17
Task 7C: Install a Terminal via ADUs 2-19
Task 7D: Install a Terminal via 7400A Data Sets 2-21
Task 8: Install the Control-Link Cable 2-24
Connect to the PI without an IDI 2-24
Connect to the PI with an IDI 2-25
Connect to the Digital Line Interface (TN754) 2-27
Connect to the Packet Gateway Board (G3r only) 2-28
Connect to the TN577 via DSUs (G3r Only) 2-29
Connect to the TN577 via MPDMs (G3r Only) 2-30
Task 9: Install the Printer (Optional) 2-31
Task 10: Finalize and Test the Hardware 2-33
3 Initial System Administration 3-1
Initial System Administration Tasks 3-1
Worksheets Needed 3-2
Control Link (CL) Only 3-2
Display Set (DS) Only 3-2
Windowing on the 715 Terminal 3-3
Task 11: Perform Initial Switch Administration 3-3
Task 12: Activate Customer Options 3-4
Display Customer Options 3-4
Change Customer Options 3-6
Task 13: Activate DEFINITY AUDIX
Server Hardware Options 3-7
Task 13A: Set System Parameters for I
NTUITY
Message Manager 3-8
Task 13B: Check Access for I
NTUITY Message
Manager 3-9
Contents
Issue 2 December 1996 v
Task 14: Perform Initial DEFINITY
AUDIX Administration 3-11
Task 14A: Set the DEFINITY AUDIX Clock 3-12
Task 14B: Assign the DEFINITY AUDIX
Machine Parameters 3-13
Task 14C: Run the Switch Translations Audit 3-14
Task 14D: Administer Voice Ports 3-15
Task 14E: Set Switch-Link Parameters 3-16
Set Switch-Link Parameters for CL Integration 3-16
Set Switch-Link Parameters for DS Integration 3-19
Task 14F: Synchronize DEFINITY AUDIX System
and Switch Clocks 3-20
Task 14G: Set System Parameters Limits 3-21
Task 14H: Run the Switch Translations Audit
a Second Time 3-23
Task 14I: Assign the Time Zone 3-23
Task 14J: Reboot the DEFINITY AUDIX System 3-25
Subtask 14K: Run the Switch Names Audit 3-26
Task 14L: Check Alarm Status 3-27
Task 14M: Check Hardware Status 3-27
Task 15: Activate Parameters and Basic Features 3-30
Task 16: Add Tape 3-32
Task 17: Check the Status of the
Switch Names Audit 3-35
4 Acceptance Checks 4-1
Acceptance Check Tasks 4-1
Worksheets Needed 4-2
Task 18: Alarm Origination
Administration/test and Status Tape 4-2
Task 19: Perform Dial Tone Test for DS
Integrated Systems 4-6
Task 20: Run Test Switch-Link Long 4-7
Task 21: Add Two Test Subscribers 4-8
Contents
vi Issue 2 December 1996
Task 22: Test the Call Answer and
Voice Mail Features 4-10
DCS Subscribers 4-11
Task 23: Run Test Tape Long 4-13
Task 24: Test Local Area Network 4-15
Task 25: Clear Administration, Error, and Alarm Logs 4-16
5 Initial Subscriber Administration 5-1
Initial Subscriber Administration Tasks 5-1
Worksheets Needed 5-2
Task 26: Add the Initial Subscribers 5-2
Task 27: Switch Names Audit (for DS
integration Only) 5-4
Task 28: Complete Initial Administration 5-4
6 Customer Acceptance 6-1
Project Management Tasks: 6-1
Task 29: Cutting the System into Service 6-1
Task 30: Perform a Walk Through 6-1
Task 31: Demonstrate Updated Customer Database 6-2
Task 32: Project Review. 6-2
7 Upgrades to R3.2 7-1
Upgrade Overview 7-1
Hardware 7-1
Analog and Digital Port Emulations 7-2
Control Link and Display Set Integrations 7-2
Upgrade Worksheet 7-3
Upgrade Checklist 7-5
Changing from AMIS to Digital Networking 7-8
Contents
Issue 2 December 1996 vii
Hardware Upgrades 7-9
Circuit Card Replacement 7-10
Control Link Upgrade 7-14
Software Upgrade 7-14
After the Upgrade 7-22
Installing, Administering, and Testing I
NTUITY
Message Manager 7-22
A Announcement Set Considerations
and Installation A-1
Customized Announcement and
Fragment Considerations A-1
Customer Modified Announcements A-2
Customer Modified and Added Fragments A-2
Announcement Set Identifiers A-2
Installing Additional Language Sets A-3
B Option Settings B-1
Terminal Option Settings B-1
PC/G3MA User Option Settings B-2
715 BCT Option Settings B-2
513 BCT Option Settings B-7
610 BCT with a 513 Emulation Package
Option Settings B-8
615 BCT with a 513 Emulation Package
Option Settings B-9
4410 and 5410 Terminal Option Settings B-10
4425 and 5425 Terminal Option Settings B-11
4415 and 5420 Terminals B-12
Modem Option Settings B-13
Lucent 2400 Modem Option Settings B-13
Software Settings B-13
Contents
viii Issue 2 December 1996
Jumper Setting B-14
Paradyne DataPort Express Modem
Option Settings B-15
Paradyne COMSPHERE 3820 Modem
Option Settings B-15
Paradyne COMSPHERE 3830 Modem
Option Settings B-15
DM424 Modem Option Settings B-16
DM224 Modem Option Settings B-16
212AR Modem Option Settings B-16
2212D Modem Option Settings B-17
MPDM Data Module Option Settings B-17
DS Integration B-17
CL Integration B-18
7400A Data Module Settings B-18
7400B Data Module Settings B-19
C PEC Explosions C-1
Complete System C-2
Primary Equipment C-4
Peripheral Equipment C-16
INTUITY Message Manager (IMM) C-19
ABB Abbreviations ABB-1
GL Glossary GL-1
IN Index IN-1
Issue 2 December 1996 ix
About This Document
Overview
This document describes the installation, initial administration, and acceptance
testing procedures for the hardware and software comprising the DEFINITY
®
AUDIX
®
Voice Messaging System release 3, version 2 (R3.2). Furthermore, this
document describes the procedures used to update a system from a previous
release to R3.2. The procedures are described in the form of specific tasks that
should be completed in sequence.
Intended Audiences
This document contains information primarily for people installing the DEFINITY
AUDIX System hardware, Software Specialists (SS), Software Associates (SA),
and other persons (such as factory personnel and customers) responsible for
performing initial administration and cut-to-service procedures. Secondarily, this
document contains information for Field Support and the remote support center.
Prerequisite Skills and Knowledge
Although the information in this document assumes no prerequisite training, it will
be substantially easier to assimilate by persons with DEFINITY AUDIX system
installation or upgrade training. To install this product, an installer should have
basic knowledge of the PBX, DEFINITY AUDIX, fault isolation, the customer’s
application, and toll fraud protection.
About This Document
x Issue 2 December 1996
Organization of This Document
This document is organized as follows:
Chapter 1, ‘‘Prerequisites’’, identifies site requirements, required tools,
safety considerations, and supported configurations.
Chapter 2, ‘Hardware Installation’’, describes all the tasks required for
installing the DEFINITY AUDIX system hardware and the associated
peripherals.
Chapter 3, ‘‘Initial System Administration’’, describes all the tasks required
to initially administer the DEFINITY AUDIX system.
Chapter 4, ‘Acceptance Checks’’, describes the tasks required to verify
the DEFINITY AUDIX system installation and operation.
Chapter 5, ‘‘Initial Subscriber Administration’’, describes how to add the
initial set of subscribers to the DEFINITY AUDIX system database.
Chapter 6, ‘‘Customer Acceptance’’, describes the tasks that the Project
Manager should conduct with the customer to demonstrate the DEFINITY
AUDIX system.
Chapter 7, ‘‘Upgrades to R3.2’’ describes considerations and procedures
to upgrade the DEFINITY AUDIX system to R3.2.
Appendix A, ‘‘Announcement Set Considerations and Installation’’,
describes customized announcement and fragment sets, and adding new
language sets.
Appendix B, ‘‘Option Settings’’, contains a list of option settings for
supported terminals and modems. However, this appendix does not
provide procedures for setting the options. Refer to the appropriate
manual supplied with the terminal and modem for these procedures.
Appendix C, ‘‘PEC Explosions’’, contains a list of the Price Element Codes
(PECs) for DEFINITY AUDIX system and peripheral hardware and
software, including a description of the contents and Comcodes for each
PEC.
A list of abbreviations, a glossary, and an index are also provided.
How to Use This Document
Those who install and upgrade hardware and software on DEFINITY AUDIX
systems should reference the tasks within the entire document, including the
appendices.
Field Support, Remote Support Center (TSC, ITAC, CDEs, and distributors), and
factory personnel should read the entire document to gain a thorough overview
of the DEFINITY AUDIX system installation procedures.
Conventions Used in This Document
Issue 2 December 1996
xi
Conventions Used in This Document
The following typographic conventions are used in this document:
Keyboard keys that you press are shown in rounded boxes. For example,
an instruction to press the carriage return or equivalent key is shown in
this document as:
Press .
The word
enter
means to type a value or command and then press the
key. For example, an instruction to type y and press is
shown in this document as:
Enter y to continue.
NOTE:
To send the information to the DEFINITY AUDIX system, the
key (located on the right side of your keyboard) must be pressed
after you type a command or a response to a prompt. On some
keyboards, this key is labeled instead of .If your
keyboard has
both
a key and an key (as on the 513
and 615 keyboards), use the key.
Two or three keys that you press at the same time (that is, you hold down
the first key while pressing the second key and, if appropriate, the third
key as well) are shown in rounded boxes separated by hyphens. For
example, an instruction to press and hold while typing the letter
d is shown in this document as:
Press - .
Information that is displayed on your terminal screen — including screen
displays, field names, prompts, and error messages — is shown in
typewriter-style constant-width type. Information that you enter from your
keyboard is shown in constant-width bold type. Here is an example:
At the login: prompt, enter audix.
Variables whose values are supplied by you or the system are shown in
italic type. For example, an error message that is displayed on the screen
with one of your specific filenames might be shown generically in this
document as:
The filesystem
filename
is out of space.
RETURN
RETURN RETURN
RETURN
ENTER RETURN
RETURN ENTER
RETURN
CONTROL
CONTROL D
About This Document
xii Issue 2 December 1996
Trademarks and Service Marks
The following trademarks are mentioned throughout this document:
AUDIX
®
is a registered trademark of Lucent Technologies.
DEFINITY
®
is a registered trademark of Lucent Technologies.
INTUITY
TM
is a trademark of Lucent Technologies.
Related Resources
The following documents are related to DEFINITY AUDIX system installation and
upgrades.
For all DEFINITY AUDIX system planning information, including the
worksheets needed for installation, see
Planning for DEFINITY AUDIX
System
, 585-300-601.
For information about earlier versions of the system, see
DEFINITY AUDIX
System — Documentation Guide
, 585-300-011. This book lists currently
available editions of books covering the earlier systems as well as version
3.2.
For complete details on ongoing administration of a DEFINITY AUDIX
system, see
DEFINITY AUDIX System Administration
, 585-300-507.
For switch administration procedures, see
Switch Administration for
DEFINITY AUDIX System
, 585-300-509.
For complete details on the DEFINITY AUDIX system, see
DEFINITY
AUDIX System — System Description
, 585-300-205.
For all maintenance procedures, see
DEFINITY AUDIX System —
Maintenance
, 585-300-110.
For installation and operation information on the G3-MA (SAT-PC), see
DEFINITY Communications System Generic 3 Management Applications
Station Provisioning
, 555-229-202.
For installation and operation information on INTUITY Message Manager,
see
I
NTUITY
Message Manager User Guide
, 585-310-725.
To order additional Lucent Technologies documents from within the USA, call the
Lucent Technologies Customer Information Center, 1-800-432-6600, and request
each item by the appropriate document number.
How to Get Help
If problems arise during installation of the DEFINITY AUDIX System that cannot
be resolved locally, call the appropriate Remote Support Center. The number will
be provided to you by the Project Manager overseeing this installation.
How to Make Comments About This Document
Issue 2 December 1996
xiii
How to Make Comments About This
Document
The reader comment card is located after the title page. While we have tried to
make this document fit your needs, we are interested in your suggestions for
improving it and urge you to fill one out.
If the reader comment card has been removed from this document, please send
your comments to:
Lucent Technologies
Product Documentation
Room 22-2H15
11900 North Pecos Street
Denver, Colorado 80234
About This Document
xiv Issue 2 December 1996
Issue 2 December 1996 1-1
1
Prerequisites
This chapter describes prerequisites for installing a DEFINITY AUDIX system.
These include:
‘‘Task 1: Verify the Selected Site’’.
‘‘Task 2: Gather Required Tools’’.
‘‘Task 3: Review Safety Considerations’’.
‘‘Task 4: Verify the Components and Connectivity’’. Before beginning the
installation, make sure you have completed these prerequisites.
NOTE:
If this Installation or Upgrade includes Digital Networking, ensure that the
Installation Specification is available and filled out.
NOTE:
The installation of INTUITY
TM
Message Manager requires that the following
information be obtained from the LAN Administrator. This information is
required for administration of the DEFINITY AUDIX Server:
Gateway Address
Subnet Mask
IP Address
Prerequisites
1-2 Issue 2 December 1996
Display Set and Control-Link
Integration
The DEFINITY AUDIX system can be connected to the switch in one of two ways:
display-set (DS) or control-link (CL) integration. CL integration requires an
external connection from the switch to an RS-232C port on the multifunction
board (MFB) of the DEFINITY AUDIX system. DS integration uses a channel
(internal to the switch) that would otherwise be used to transfer display-set
information.
The procedural differences due to these different characteristics are clearly
defined in the tasks and diagrams that follow. However, you need to know which
integration type — DS or CL — to set up for this installation. If you do not know
whether this system is to be installed for DS or CL integration, contact the project
manager or the remote support center before proceeding.
Task 1: Verify the Selected Site
NOTE:
Although defining and ensuring that the site meets the DEFINITY AUDIX
system requirements is the responsibility of the Project Manager and the
customer, and must be
completed before
you install the DEFINITY AUDIX
system, the guidelines are listed here so that you are aware of these
requirements.
Verify that the site selected for the switch and the DEFINITY AUDIX system
provides the following:
For a DEFINITY AUDIX system being installed in an existing switch, five
(four for a G3vs) contiguous slots in a switch carrier to house the
DEFINITY AUDIX system (see
Planning for the DEFINITY AUDIX System
,
585-300-904, for switch reconfiguration details)
Easy access for cabling
Good workspace for the system administrator and/or operators
Temperature range of 50 to 100° F (10 to 38° C), with the ideal range being
50 to 80° F
Humidity range of 20 to 80%, noncondensing. In addition, make sure the
site is secure and provides protection from excessive sunlight, heat, cold,
chemicals, static electricity, magnetic fields, vibration, and grime.
Task 2: Gather Required Tools
Issue 2 December 1996
1-3
Task 2: Gather Required Tools
To install an DEFINITY AUDIX system, you must have the following tools:
No. 1 or No. 2 Phillips screwdriver
Narrow width, flat blade screwdriver
1/4-inch nut driver (recommended)
Antistatic grounded wrist strap
Task 3: Review Safety Considerations
!
WARNING:
Electronic equipment can be damaged by electrostatic discharge. Do not
touch any electronic component unless you are properly grounded.
!
DANGER:
Do not touch the switch backplane while installing the DEFINITY AUDIX
system. The backplane contains dangerous voltages and current.
To prevent damage to the equipment and yourself, adhere to the following:
Make sure you are familiar with the procedures necessary to prevent
electrostatic damage to the equipment.
Properly ground a wrist strap.
Place the grounded wrist strap on your bare wrist. (The wrist strap must
contact your bare skin directly—do
not
wear it over your clothes.)
Do not remove the DEFINITY AUDIX System assembly from the
polyethylene bag until:
Your wrist strap is on your wrist and properly grounded.
You have made room in the switch carrier and you are ready to
insert the DEFINITY AUDIX System assembly in the carrier.
If you need to work on the DEFINITY AUDIX System assembly — that is,
disassemble it — place the assembly on a grounded antistatic work mat.
Prerequisites
1-4 Issue 2 December 1996
Task 4: Verify the Components and
Connectivity
Review the connectivity diagrams in Figure 1-1: DEFINITY AUDIX System
Connectivity Diagram — CL Integration, Figure 1-2: DEFINITY AUDIX System
Connectivity Diagram — DS Integration, and Figure 1-3: DEFINITY AUDIX LAN
Connectivity, on the following pages to gain a general understanding of how the
DEFINITY AUDIX system is to be connected.
In these drawings various optional connection methods are shown in coupling
brackets. For example, the brackets in Figure 1-1 include the several connection
methods mentioned under: ‘‘Task 8: Install the Control-Link Cable’’ on page 2-24
and subsequently described in detail. Likewise, the terminal wiring appropriate
to DS integration is explained at considerable length under: ‘‘Task 7: Install the
Terminals’’ on page 2-13.
Refer to the diagrams in the tasks just described for connectivity details.
Then compare the Price Element Code (PEC) and comcode list contained in
Chapter C with the actual parts you received to make sure that all the required
parts have been ordered and shipped correctly. In addition to the orderable
components listed in Appendix E, other terminals, modems, and printers are
supported and may be used in the DEFINITY AUDIX system configuration.
If you did not receive (or do not have on hand) all the required parts, follow your
normal claims procedure with the factory to acquire the missing parts. After you
have reviewed the connectivity diagram and have verified the DEFINITY AUDIX
system components, proceed to the tasks in Chapter 2, ‘‘Hardware Installation’’.
NOTE:
If DEFINITY AUDIX will be used as a server for Local Area Network (LAN)
applications such as I
NTUITY
Message Manager, it is recommended that
the customer-provided LAN connection is available prior to installation of
the DEFINITY AUDIX.
Task 4: Verify the Components and Connectivity
Issue 2 December 1996
1-5
Figure 1-1. DEFINITY AUDIX System Connectivity Diagram — CL Integration
TN765
Processor
Interface
Most Switches†
Except G3r
All Switches
Except G3r
TN754
Digital Line
Interface
TN765
Processor
Interface
G3r ONLY
IDI
IDI
SYNCHRONOUS NULL
MODEM CABLE
* Administered Connection
† Other excluded switches are: duplicated G3i, switches on DC power, System 75 R1V3 without a
PI/EIA port, and switches using the EIA connector on the PI board for another adjunct (such as CMS).
‡ If ADAP software is used on this terminal, the administrator must have dial-up capabilities.
The terminal must therefore be connected to PORT A via a modem connection.
PORT B
PORT A
RS-232 TO NON-US MODEM
TO
CROSS-CONNECT
FIELD (X-C)
LAN
ALB
CABLE
MPDM
MPDM
DSUDSU X-C
X-C
X-C
MPDM X-C
110 V
110 V
110 V110 V
110 V
MFB
Y
CABLE
SWITCH
ALARM
BOARD
MULTI-
FUNCTION
BOARD
LOCAL
TERMINAL‡
TN577
Packet
Gateway
TN754
*
TN754
Digital Line
Interface
Prerequisites
1-6 Issue 2 December 1996
Figure 1-2. DEFINITY AUDIX System Connectivity Diagram — DS Integration
POWER
SUPPLY
7400A
POWER
SUPPLY
7400B
Z3A1
POWER
SUPPLY
SWITCH
ALARM
BOARD
MULTI-
FUNCTION
BOARD
MFB
Y
CABLE
LOCAL
TERMINAL
PORT B
MODEM MODEM
T/R
ADAPTER
Z3A4
Site-Specific
Connection
HOUSE
WIRING
NULL MODEM
TERMINAL
OPTIONAL
PRINTER
PORT A
RS-232 to non-US modem
TO
CROSS-CONNECT
FIELD
LAN
ALB
CABLE
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180
  • Page 181 181
  • Page 182 182
  • Page 183 183
  • Page 184 184
  • Page 185 185
  • Page 186 186
  • Page 187 187
  • Page 188 188
  • Page 189 189
  • Page 190 190
  • Page 191 191
  • Page 192 192
  • Page 193 193
  • Page 194 194
  • Page 195 195
  • Page 196 196
  • Page 197 197
  • Page 198 198
  • Page 199 199
  • Page 200 200
  • Page 201 201
  • Page 202 202
  • Page 203 203
  • Page 204 204
  • Page 205 205
  • Page 206 206
  • Page 207 207
  • Page 208 208

Lucent Technologies Definity Audix System Installation And Upgrade

Type
Installation And Upgrade

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI