ADTRAN 110-Pair Protector Panel For Total Access 1500 Job Aid

Type
Job Aid
110-PAIR PROTECTOR PANEL
FOR TOTAL ACCESS
®
1500
JOBAID
61190TA15PL1-22B
0206
110-PAIR PROTECTOR PANEL CLEI: VAM4FNOE _ _
GENERAL
The ADTRAN 110-Pair Protector Panel with solid state surge modules is designed to protect the
associated Total Access 1500 chassis and components by shunting to ground lightning strike
surges or other electrical surges seen on any of the network or customer loops. The panel and
connectors are pre-wired for ease of installation and all connectors, wiring, and panels clearly
labeled and identified (see illustration). Standard installation is in close proximity to the associ-
ated ADTRAN Total Access 1500.
PHYSICAL DESCRIPTION
The protector panel fits a standard 23-inch rack and is 2 RU high, the front panel mounts flush to
the bay. The housing is all metal construction with a powder coated enamel finish. Extrusions
are provided for dressing and lacing wires, and rubber grommet inserts on the rear panel protect
the exit cables from chaffing.
CUSTOMER WIRING CONNECTIONS
The protector modules are arranged in a 50-pair, 50-pair, 10-pair configuration. The protector
block terminates at six pre-wired splice modules as described here:
On the customer side, four splice modules accommodate 25-pair customer loops each.
On the network side, two splice modules accommodate the 10-pair for the T1 network loop; one
for 5 transmit pair and one for 5 receive pair.
The cable stubs for all six splice modules are 48 inches long. See the Customer Splice Module
Pinout table on the reverse side for customer required wiring.
A removable panel on the protector block backplane protects the wire-wrap pins. On the Total
Access 1500 side of the loop, factory wire-wrap pins terminate at four Amphenol connectors that
in turn connect to the Total Access 1500 backplane on connectors P1 through P4. These cables
are 36 inches long.
T1
T1 on the customer side is prewired to the protector panel and will terminate at the Total Access
1500 backplane on wire-wrap pins labeled P7 through P11. The customer is responsible for mak-
ing the wire-wrap connection to the Total Access 1500 backplane. Cable stub length is 36 inches.
See the T1 Splice Module Pinout table for customer required wiring.
CAUTION: Terminate all grounds to an approved ground location. Check metal-to-metal contact on all ground
connections. Ensure ground circuit continuity.
T1 Splice Module Pinout
Pair Color Splice Module Protect Block Total Access 1500
Code Position Position Connection
Transmit Splice Connector
1 wh/blu 1 A T/R A T/R
blu/wh 2
2 wh/orn 3 B T/R B T/R
orn/wh 4
3 wh/grn 5 C T/R C T/R
grn/wh 6
4 wh/brn 7 D T/R D T/R
brn/wh 8
5 wh/slt 9 P T/R P T/R
slt/wh 10
Receive Splice Connector
1 wh/blu 1 A T1/R1 A T1/R1
blu/wh 2
2 wh/orn 3 B T1/R1 B T1/R1
orn/wh 4
3 wh/grn 5 C T1/R1 C T1/R1
grn/wh 6
4 wh/brn 7 D T1/R1 D T1/R1
brn/wh 8
5 wh/slt 9 P T1/R1 P T1/R1
slt/wh 10
Specifications
Environmental
Operating Temperature -40°C to 65°C (-40°F to 149°F)
Storage Temperature -40°C to 85°C (-40°F to 185°F)
Relative Humidity 95 percent non-condensing, max
Pyhsical
Operating Temperature -40°C to 65°C (-40°F to 149°F)
Dimensions 23 in. W x 3-1/2 in. H x 3 in. D
Weight 10 lb. w/ cable stubs & connectors
C A U T I O N C A U T I O N !
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
#61190TA15PL1-22B#
110-PAIR PROTECTOR PANEL
FOR TOTAL ACCESS
®
1500
PRICING AND AVAILABILITY 800.827.0807
TECHNICAL SUPPORT 800.726.8663
RETURN FOR REPAIR 256.963.8722
www.adtran.com
61190TA15PL1-22B
GROUND CONNECTION
A 48-inch length of stranded 6 AWG ground wire with black PVC insulation and ring terminals on
both ends is fixed to a ground lug on the right front underside of the housing. Ring lugs are sized
for a #10 stud. Terminate this ground wire to an approved ground source.
MODULE REPLACEMENT
Each module protects a particular slot position or T1 feed in the Total Access 1500. When an
electrical surge occurs the solid state module will shunt the surge to ground and will automatically
return to normal after the surge diminishes. To remove a failed module, pull on the extension
handle.
Replace with a new module of identical features and rating. On a removed module the failed side
can be identified by continuity checks. Continuity between the central ground prong and any tip
or ring prong indicates a failed module.
Two types of solid state surge modules are used:
T1 network (red) modules; ADTRAN P/N 3186008
Customer loop (black) modules; ADTRAN P/N 3186007
Customer Splice Modules Wiring Arrangenment and Pinout
WA
Pair 1-25, Blue Binder Group
Pair Splice Color Code Protect Total Access
Module (T/R) Block 1500
Position Position Location
Slot Line
1 1/2 wh-blu/blu-wh 1 1 1
2 3/4 wh-or/or-wh 2 2
3 5/6 wh-gr/gr-wh 3 3
4 7/8 wh-br/br-wh 4 4
5 9/10 wh-sl/sl-wh 5 2 1
6 11/12 rd-blu/blu-rd 6 2
7 13/14 rd-or/or-rd 7 3
8 15/16 rd-gr/gr-rd 8 4
9 17/18 rd-br/br-rd 9 3 1
10 19/20 rd-sl/sl-rd 10 2
11 21/22 blk-blu/blu-blk 11 3
12 23/24 blk-or/or-blk 12 4
13 25/26 blk-gr/gr-blk 13 4 1
14 27/28 blk-br/br-blk 14 2
15 29/30 blk-sl/sl-blk 15 3
16 31/32 yel-blu/blu-yel 16 4
17 33/34 yel-or/or-yel 17 5 1
18 35/36 yel-gr/gr-yel 18 2
19 37/38 yel-br/br-yel 19 3
20 39/40 yel-sl/sl-yel 20 4
21 41/42 vio-blu/blu-vio 21 6 1
22 43/44 vio-or/or-vio 22 2
23 45/46 vio-gr/gr-vio 23 3
24 47/48 vio-br/br-vio 24 4
25 49/50 vio-sl/sl-vio 25 7 1
Pair 26-50, Orange Binder Group
Pair Splice Color Code Protect Total Access
Module (T/R) Block 1500
Position Position Location
Slot Line
1 1/2 wh-blu/blu-wh 26 7 2
2 3/4 wh-or/or-wh 27 3
3 5/6 wh-gr/gr-wh 28 4
4 7/8 wh-br/br-wh 29 8 1
5 9/10 wh-sl/sl-wh 30 2
6 11/12 rd-blu/blu-rd 31 3
7 13/14 rd-or/or-rd 32 4
8 15/16 rd-gr/gr-rd 33 9 1
9 17/18 rd-br/br-rd 34 2
10 19/20 rd-sl/sl-rd 35 3
11 21/22 blk-blu/blu-blk 36 4
12 23/24 blk-or/or-blk 37 10 1
13 25/26 blk-gr/gr-blk 38 2
14 27/28 blk-br/br-blk 39 3
15 29/30 blk-sl/sl-blk 40 4
16 31/32 yel-blu/blu-yel 41 11 1
17 33/34 yel-or/or-yel 42 2
18 35/36 yel-gr/gr-yel 43 3
19 37/38 yel-br/br-yel 44 4
20 39/40 yel-sl/sl-yel 45 12 1
21 41/42 vio-blu/blu-vio 46 2
22 43/44 vio-or/or-vio 47 3
23 45/46 vio-gr/gr-vio 48 4
24 47/48 vio-br/br-vio 49 13 1
25 49/50 vio-sl/sl-vio 50 2
Pair 51-75, Green Binder Group
Pair Splice Color Code Protect Total Access
Module (T/R) Block 1500
Position Position Location
Slot Line
1 1/2 wh-blu/blu-wh 51 13 3
2 3/4 wh-or/or-wh 52 4
3 5/6 wh-gr/gr-wh 53 14 1
4 7/8 wh-br/br-wh 54 2
5 9/10 wh-sl/sl-wh 55 3
6 11/12 rd-blu/blu-rd 56 4
7 13/14 rd-or/or-rd 57 15 1
8 15/16 rd-gr/gr-rd 58 2
9 17/18 rd-br/br-rd 59 3
10 19/20 rd-sl/sl-rd 60 4
11 21/22 blk-blu/blu-blk 61 16 1
12 23/24 blk-or/or-blk 62 2
13 25/26 blk-gr/gr-blk 63 3
14 27/28 blk-br/br-blk 64 4
15 29/30 blk-sl/sl-blk 65 17 1
16 31/32 yel-blu/blu-yel 66 2
17 33/34 yel-or/or-yel 67 3
18 35/36 yel-gr/gr-yel 68 4
19 37/38 yel-br/br-yel 69 18 1
20 39/40 yel-sl/sl-yel 70 2
21 41/42 vio-blu/blu-vio 71 3
22 43/44 vio-or/or-vio 72 4
23 45/46 vio-gr/gr-vio 73 19 1
24 47/48 vio-br/br-vio 74 2
25 49/50 vio-sl/sl-vio 75 3
Pair 76-100, Brown Binder Group
Pair Splice Color Code Protect Total Access
Module (T/R) Block 1500
Position Position Location
Slot Line
1 1/2 wh-blu/blu-wh 76 19 4
2 3/4 wh-or/or-wh 77 20 1
3 5/6 wh-gr/gr-wh 78 2
4 7/8 wh-br/br-wh 79 3
5 9/10 wh-sl/sl-wh 80 4
6 11/12 rd-blu/blu-rd 81 21 1
7 13/14 rd-or/or-rd 82 2
8 15/16 rd-gr/gr-rd 83 3
9 17/18 rd-br/br-rd 84 4
10 19/20 rd-sl/sl-rd 85 22 1
11 21/22 blk-blu/blu-blk 86 2
12 23/24 blk-or/or-blk 87 3
13 25/26 blk-gr/gr-blk 88 4
14 27/28 blk-br/br-blk 89 23 1
15 29/30 blk-sl/sl-blk 90 2
16 31/32 yel-blu/blu-yel 91 3
17 33/34 yel-or/or-yel 92 4
18 35/36 yel-gr/gr-yel 93 24 1
19 37/38 yel-br/br-yel 94 2
20 39/40 yel-sl/sl-yel 95 3
21 41/42 vio-blu/blu-vio 96 4
22 43/44 97 1
23 45/46 No 98 2
24 47/48 Connection 99 3
25 49/50 100 4
MAINTENANCE
Aside from replacing failed modules there is no maintenance required for normal operation.
WARRANTY
Warranty for Carrier Networks products manufactured by ADTRAN and supplied under Buyers order for
use in the U.S. is ten (10) years. For a complete copy of ADTRAN’s U.S. and Canada Carrier Networks
Equipment Warranty (P/N 60000087-10): (877) 457-5007, faxback Document 414.
  • Page 1 1
  • Page 2 2

ADTRAN 110-Pair Protector Panel For Total Access 1500 Job Aid

Type
Job Aid

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI