V-ZUG 975 induction glass ceramic hob offers precise and efficient cooking with its induction technology. It features a sleek frameless design with facets, enhancing the aesthetics of your kitchen. The hob comes with various accessories, including ventilation protective plates for different niche widths, ensuring proper airflow and optimal performance. Installation requires a qualified electrician and adherence to low voltage installation guidelines. Utilize the identification plate for accurate mains voltage, current type, and fuse specifications.

V-ZUG 975 induction glass ceramic hob offers precise and efficient cooking with its induction technology. It features a sleek frameless design with facets, enhancing the aesthetics of your kitchen. The hob comes with various accessories, including ventilation protective plates for different niche widths, ensuring proper airflow and optimal performance. Installation requires a qualified electrician and adherence to low voltage installation guidelines. Utilize the identification plate for accurate mains voltage, current type, and fuse specifications.

Installation instructions
Induction glass ceramic hob
Frameless, with facets
J975.133-1
6.12.11 HGSI
1
These installation instructions apply to the model: 975 (GK36TIPS)
Identification plate
The identification plate is next to the connection plate.
Affix the second identification plate (enclosed) in an accessible position behind
the front of the fitted cabinet beneath the appliance.
Refer to the identification plate for specifications for the required mains voltage, current type and fuses.
Application height of the appliance: up to max. 2000 m above sea level
The appliance is equipped with a mains cable that should be connected to a distribution box by the customer.
The appliance should be installed by qualified personnel only. Each step must be carried out and checked in full in the order
specified.
Validity
General notes
If fitting in flammable material, the guidelines and standards for low voltage installations and for the fire protection must be
strictly observed.
This appliance is considered to be suitable for use in countries having a warm damp equable climate (WDaE). It may also be
used in other countries. If used in warm damp equable climated countries, the appliance is to be supplied through a residual
current device (RCD) having a rated residual operating current not exceeding 30 mA.
Accessories
Designation Art. no.
Ventilation protective plate set
For niche width 550 mm
For niche width 600 mm
For niche width 825 mm
For niche width 900 mm
H6.1082
H6.1083
H6.1084
H6.1085
Electrical connections
Electrical connections must made by trained electricians in accordance with the guidelines and standards for low voltage
installations and the specifications of the local electricity supply companies.
A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and
socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching
are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and
fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Old installations should
always be checked.
Connection plate
Identification plate
600/550
Installation pipe Distribution box
Clamp
400 V~ 2N
PE/
green
/
yellow
N blue
L1 brown
L2 black
230 V~
AUS / NZ
PE/ green/yellow
N blue
L1 brown
Installation instructions
Induction glass ceramic hob
Frameless, with facets
J975.133-1
6.12.11 HGSI
2
Error message U400
Indications
The work surface has to be flat to ensure that the appliance is adequately sealed against liquids.
In order to guarantee good ventilation, there needs to be a space of at least 17.5 mm height beneath the appliance.
Installing
1. Cut out mounting cut-out precisely.
2. Carefully place the appliance in the mounting cut-out and press against the work surface with sufficient overlap.
Incorrect connection:
A pole conductor was connected to the connecting terminal for neutral conductors.
Quickly disconnect the appliance from the mains!
Installation
The layout of the cooking zones on the integrated hob may differ from the illustrated hob!
(30)
774
444
420 ±1
min. 50
min. 50
750 ±1
600/550
45.7
from level
For symmetrical fitting,
it is not necessary to
cut out the side walls.
aim for
max. R10
Installation instructions
Induction glass ceramic hob
Frameless, with facets
J975.133-1
6.12.11 HGSI
3
Cool air supply if installed over a drawer or cabinet
In order to guarantee good ventilation, there needs to be a space of at least 17.5 mm height beneath the appliance.
With a protective plate beneath the ventilator
A guard plate is recommended in the vicinity of the mains cable and to protect the ventilator openings (see «Accessories»).
Fan
Drawer
min. 25 cm
2
air gap over the entire cabinet element
Necessary space for the ventilation
below the worktop required
45.7
min. 63.2
(30)
min. 17 cm
2
Air gap over the entire cabinet element width
Warning:
Do not place main cable in the
area of the protective plate
Fan
Drawer
max. 0.5
min. 15
393
(19.5)
48
5. .10
55.5
(30)
min. 3
m
in. 67.5
Well-fitting seal over width
of cabinet element
According to template
  • Page 1 1
  • Page 2 2
  • Page 3 3

V-ZUG 975 Installation guide

Type
Installation guide

V-ZUG 975 induction glass ceramic hob offers precise and efficient cooking with its induction technology. It features a sleek frameless design with facets, enhancing the aesthetics of your kitchen. The hob comes with various accessories, including ventilation protective plates for different niche widths, ensuring proper airflow and optimal performance. Installation requires a qualified electrician and adherence to low voltage installation guidelines. Utilize the identification plate for accurate mains voltage, current type, and fuse specifications.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI