Extron TLP Pro 320M User manual

Category
Gateways/controllers
Type
User manual

This manual is also suitable for

68-2515-01 Rev. A
07 15
TLP Pro 320M
User Guide
TouchLink
®
TouchLink Pro Touchpanel Control Systems
Safety Instructions • English
WARNING: This symbol,
D
, when used on the product, is intended
to alert the user of the presence of uninsulated dangerous voltage
within the product’s enclosure that may present a risk of electric shock.
ATTENTION: This symbol,
I
, when used on the product, is
intended to alert the user of important operating and maintenance
(servicing) instructions in the literature provided with the equipment.
For information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and
Regulatory Compliance Guide, part number 68-290-01, on the Extron
website, www.extron.com.
Instructions de sécurité • Français
AVERTISSEMENT : Ce pictogramme,
D
, lorsqu’il est utilisé sur
le produit, signale à l’utilisateur la présence à l’intérieur du boîtier du
produit d’une tension électrique dangereuse susceptible de provoquer
un choc électrique.
ATTENTION : Ce pictogramme,
I
, lorsqu’il est utilisé sur
le produit, signale à l’utilisateur des instructions d’utilisation ou de
maintenance importantes qui se trouvent dans la documentation
fournie avec le matériel.
Pour en savoir plus sur les règles de sécurité, la conformité à la
réglementation, la compatibilité EMI/EMF, l’accessibilité, et autres sujets
connexes, lisez les informations de sécurité et de conformité Extron,
réf. 68-290-01, sur le site Extron, www.extron.com.
Sicherheitsanweisungen • Deutsch
WARNUNG: Dieses Symbol
D
auf dem Produkt soll den Benutzer
darauf aufmerksam machen, dass im Inneren des Gehäuses dieses
Produktes gefährliche Spannungen herrschen, die nicht isoliert sind
und die einen elektrischen Schlag verursachen können.
VORSICHT: Dieses Symbol
I
auf dem Produkt soll dem Benutzer
in der im Lieferumfang enthaltenen Dokumentation besonders wichtige
Hinweise zur Bedienung und Wartung (Instandhaltung) geben.
Weitere Informationen über die Sicherheitsrichtlinien, Produkthandhabung,
EMI/EMF-Kompatibilität, Zugänglichkeit und verwandte Themen finden Sie
in den Extron-Richtlinien für Sicherheit und Handhabung (Artikelnummer
68-290-01) auf der Extron-Website, www.extron.com.
Instrucciones de seguridad • Español
ADVERTENCIA: Este símbolo,
D
, cuando se utiliza en el producto,
avisa al usuario de la presencia de voltaje peligroso sin aislar dentro del
producto, lo que puede representar un riesgo de descarga eléctrica.
ATENCIÓN: Este símbolo,
I
, cuando se utiliza en el producto,
avisa al usuario de la presencia de importantes instrucciones de uso y
mantenimiento recogidas en la documentación proporcionada con el
equipo.
Para obtener información sobre directrices de seguridad, cumplimiento
de normativas, compatibilidad electromagnética, accesibilidad y temas
relacionados, consulte la Guía de cumplimiento de normativas y seguridad
de Extron, referencia 68-290-01, en el sitio Web de Extron,
www.extron.com.
Инструкция по технике безопасности Русский
ПРЕДУПРЕЖДЕНИЕ: Данный символ,
D
, если указан
на продукте, предупреждает пользователя о наличии
неизолированного опасного напряжения внутри корпуса
продукта, которое может привести к поражению электрическим
током.
ВНИМАНИЕ: Данный символ,
I
, если указан на продукте,
предупреждает пользователя о наличии важных инструкций по
эксплуатации и обслуживанию в руководстве, прилагаемом к
данному оборудованию.
Для получения информации о правилах техники безопасности,
соблюдении нормативных требований, электромагнитной
совместимости (ЭМП/ЭДС), возможности доступа и других вопросах
см. руководство по безопасности и соблюдению нормативных
требований Extron на сайте Extron: www.extron.com, номер по
каталогу - 68-290-01.
安全说明 简体中文
警告D产品上的这个标志意在警告用户该产品机壳内有暴露的危险 电压,
险。
注意I 产品上的这个标志意在提示用户设备随附的用户手册中有
重要的操作和维护(维修说明。
关于我们产品的安全指南、遵循的规范、EMI/EMF 的兼容性、无障碍
使用的特性等相关内容,敬请访问 Extron 网站 www.extron.com,参见 Extron
安全规范指南,产品编号 68-290-01
安全記事 繁體中文
警告: D 若產品上使用此符號,是為了提醒使用者產品殼內存在著
可能會導致觸電之風險的未絕緣危險電壓。
注意I 若產品上使用此符號,是為了提醒使用者設備隨附的用手冊中有重要
護( )説
有關安全性指導方針遵守EMI/EMF 相容性、存取範圍和相關主題的詳細資訊,
請瀏覽 Extron 網站www.extron.com然後參閱《Extron 安全性與法規遵守
則編號 68-290-01
安全上の注意
日本語
警告: この D が製品上に表示されている場合は、筐体内に絶縁され
いないれ、電のあることを示しています
注意:この I が 製 品 上 に 表 示 さ れ て い る 場 合 は 本 機 の 取 説 明 書 に 記 載 さ れ て
る重作と保()の示についてユーザー意をするもので
安全上の注意、法令遵守、EMI/EMF適合性、その他の関連項目
スト イト www.extron.com より
Extron Safety and Regulatory Compliance Guide(P/N 68-290-01) をご覧く
ださい
안전 지침 한국어
경고: 이 기호 D, 가 제품에 사용될 경우, 제품의 인클로저 내에 있는
접지되지 않은 위험한 전류로 인해 사용자가 감전될 위험이 있음을
경고합니다.
주의: 이 기호 I, 가 제품에 사용될 경우, 장비와 함께 제공된 책자에 나와
있는 주요 운영 및 유지보수(정비) 지침을 경고합니다.
전 가이드라인, 규제 준수, EMI/EMF 호환성, 접근성, 그리고 관련 항목에 대한
세한 내용은 Extron 웹 사이트(www.extron.com)의 Extron 안전 및 규제 준수
안내서, 68-290-01 조항을 참조하십시오.
Safety Instructions
FCC Class A Notice
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to part15 of the FCC rules. The ClassA limits provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause interference.
This interference must be corrected at the expense of the user.
NOTE:
This unit was tested with shielded I/O cables on the peripheral devices. Shielded cables
must be used to ensure compliance with FCC emissions limits.
For more information on safety guidelines, regulatory compliances, EMI/EMF
compatibility, accessibility, and related topics, see the Extron Safety and Regulatory
Compliance Guide on the Extron Website.
Battery Notice
This product contains a battery. Do not open the unit to replace the battery. If the
battery needs replacing, return the entire unit to Extron (for the correct address, see the Extron
Warranty section on the last page of this guide).
CAUTION: Risk of Explosion if Battery is replaced by an Incorrect Type. Dispose of Used
Batteries According to the Instructions.
ATTENTION : Risque d’explosion. Ne pas remplacer la pile par le mauvais type de pile.
Débarrassez-vous des piles utilisées selon le mode d’emploi.
Copyright
© 2015 Extron Electronics. All rights reserved.
Trademarks
All trademarks mentioned in this guide are the properties of their respective owners.
The following registered trademarks(
®
), registered service marks(
SM
), and trademarks(
TM
) are the property of
RGBSystems, Inc. or Extron Electronics:
Registered Trademarks
(
®
)
AVTrac, Cable Cubby, CrossPoint, eBUS, EDID Manager, EDID Minder, Extron, Flat Field, FlexOS, GlobalViewer, Global Configurator, Hideaway,
Inline, IPIntercom, IPLink, Key Minder, LockIt, MediaLink, PlenumVault, PoleVault, PowerCage, Pure3, Quantum, SoundField, SpeedMount,
SpeedSwitch, SystemINTEGRATOR, TeamWork, TouchLink, V-Lock, VersaTools, VN-Matrix, VoiceLift, WallVault, WindoWall, XTP, and
XTP Systems
Registered Service Mark
(SM)
: S3 Service Support Solutions
Trademarks
(
)
AAP, AFL (Accu-Rate Frame Lock), ADSP (Advanced Digital Sync Processing), Auto-Image, CableCover, CDRS (Class D Ripple Suppression),
DDSP (Digital Display Sync Processing), DMI (Dynamic Motion Interpolation), DriverConfigurator, DSPConfigurator, DSVP (Digital Sync
Validation Processing), DTP, eLink, EQIP, FastBite, FOX, FOXBOX, IP Intercom HelpDesk, LinkLicense, MAAP, MicroDigital, NetPA, ProDSP,
QS-FPC (QuickSwitch Front Panel Controller), Room Agent, Scope-Trigger, ShareLink, SIS, Simple Instruction Set, Skew-Free, SpeedNav,
Triple-Action Switching, True4K, Vector, WebShare, XTRA, ZipCaddy, and ZipClip
Conventions Used in this Guide
Notifications
In this user guide, the following are used:
WARNING: Potential risk of severe injury or death.
AVERTISSEMENT : Risque potentiel de blessure grave ou de mort.
CAUTION: Risk of minor personal injury.
ATTENTION : Risque de blessuremineure.
ATTENTION:
Risk of property damage.
Risque de dommages matériels.
NOTE: A note draws attention to important information.
Software Commands
Commands are written in the fonts shown here:
^AR Merge Scene,,Op1 scene 1,1 ^B 51 ^W^C
[01] R 0004 00300 00400 00800 00600 [02] 35 [17] [03]
E
X!
*
X1&
*
X2)
*
X2#
*
X2!
CE
}
NOTE: For commands and examples of computer or device responses mentioned
in this guide, the character “0” is used for the number zero and “O” represents the
capital letter “o”.
Computer responses and directory paths that do not have variables are written in the font
shown here:
Reply from 208.132.180.48: bytes=32 times=2ms TTL=32
C:\Program Files\Extron
Variables are written in slanted form as shown here:
ping xxx.xxx.xxx.xxx —t
SOH R Data STX Command ETB ETX
Selectable items, such as menu names, menu options, buttons, tabs, and field names are
written in the font shown here:
From the File menu, select New.
Click the
OK button.
Specifications Availability
Product specifications are available on the Extron Website, www.extron.com.
Extron Glossary of Terms
A glossary of terms is available at www.extron.com/technology/glossary.aspx.
Contents
Introduction............................................................ 1
About the TLP Pro 320M .................................... 1
Features ............................................................. 1
Application Diagram ........................................... 2
Requirements ..................................................... 2
Software ......................................................... 2
Hardware ........................................................ 2
Installation Overview ........................................... 3
Panel Features ...................................................... 5
TLP Pro 320M Front Panel Features ................... 5
TLP Pro 320M Front Panel Features
(Bezel Removed) ............................................... 6
TLP Pro 320M Rear Panel Features .................... 7
Setup Menu .......................................................... 11
Status Screen ................................................... 12
Network Screen ................................................ 13
Display Screen.................................................. 16
Audio Screen .................................................... 17
Advanced Screen ............................................. 18
Calibration Screen ............................................ 19
Configuration Software ..................................... 20
Configuration Software ..................................... 20
Installing GUI Designer, Global Configurator,
and Toolbelt ................................................. 21
Using the Software ....................................... 21
TLP Pro 320M Web Page ................................. 22
Updating Firmware ........................................... 23
Downloading Firmware ................................. 23
Updating Firmware Using the
Touchpanel Web Page ................................. 23
Updating Firmware Using Toolbelt ................. 23
Mounting ............................................................... 24
Wall or Furniture Mounting ................................ 24
Other Mounting Options ................................... 26
Underwriters Laboratories Guidelines
for Rack Mounting ....................................... 26
Button Kits ........................................................... 27
Installing or Replacing Buttons .......................... 27
Button Replacement ..................................... 27
Reference Material ............................................. 28
Network Port Requirements.............................. 28
IP Link Pro Control Processors ..................... 28
TouchLink Pro Touchpanels .......................... 29
Global Configurator Plus and Professional
Software ...................................................... 29
Toolbelt Software .......................................... 29
TouchLink for iPad (for IP Link Pro
Control Systems) ......................................... 29
Reset Modes .................................................... 30
Use Factory Firmware ................................... 30
Reset All IP Settings ..................................... 31
Reset to Factory Defaults .............................. 31
Licensed Third-Party Software
Used in the Touchpanels ................................. 32
TLP Pro 320M • Contents v
TLP Pro 320M • Contents vi
Introduction
This guide describes the function, installation, and operation of the TLPPro320M
TouchLinkPro touchpanel. Unless otherwise stated, the terms TLP Pro and touchpanel refer to
the TLP Pro 320M.
This section contains the following information:
About the TLP Pro 320M
Features
Application Diagram
Requirements
About the TLP Pro 320M
The Extron TLP Pro 320M is a 3.5 inch wall mounted touchpanel with an 320x240 LCD
touchscreen. The front panel also has eight customizable backlit buttons and a volume control
knob. The TLP Pro 320M works with any Extron IP Link Pro control processor and is ideal for
any AV application requiring a compact touchpanel with flexible mounting options and a fully
customizable interface. A range of mounting options are available (see Mounting on page24).
Power over Ethernet (PoE) allows the touchpanel to receive power and communications over a
single Ethernet cable.
The screen layout is designed with the Extron GUI Designer software. The functions are
assigned to the screen objects with the Extron Global Configurator Plus and Professional
software. The user can define the graphics and the functions associated with those graphics,
providing versatility and adaptability to the configuration and control of an AV system.
A motion sensor, light sensor, and a speaker provide sleep mode, auto dimming, and audible
feedback.
Features
3.5-inch LCD touchscreen — with 320x240 resolution and 18-bit color depth.
Faster processing and more memory — allows for quicker configuration uploads and more
storage for GUI pages.
Eight customizable backlit buttons and a user-friendly volume knob.
Compatible with all Extron IP Link Pro control processors.
Power over Ethernet (PoE 802.3af, class3) compliance — allows the touchpanel to
receive power and control over a single Ethernet cable, eliminating the need for a local power
supply. The power injector is sold separately.
Built-in speaker — with improved audio performance, provides audible feedback from button
presses.
Light sensor — adjusts screen brightness as the ambient room lighting changes.
Configurable red and green status lights — indicate the availability or call status of a room.
System connection status indicator — the communication LED provides visual feedback if
the touchpanel is not communicating with a control processor.
Automatic clock synchronization — allows touchpanel to display the accurate time and
date.
Energy-saving features
Adjustable sleep timer puts touchpanel into sleep mode.
Motion detector wakes touchpanel.
TLP Pro 320M • Introduction 1
Fully customizable using Extron control system software — using GUI Designer,
Global Configurator Plus and Professional, and Toolbelt.
Multiple mounting optionsmounts on a wall, lectern, or any flat surface.
Supports Extron Control App and Extron Control for Web.
Application Diagram
POWER
12V
--A MAX
G
Tx Rx RTSCTS
COM 1
G
Tx Rx
COM 2
VCG
VOL
RELAYS
1 2 C
1 2 3 4 G
DIGITAL I/O
PWR OUT = 6W
eBUS
+V +S
-S
G
LAN
IPCP PRO 250
IR/S
S G
POWER
12V
0.7A MAX
LR
L
8Ω / 4Ω
CLASS 2
WIRING
R
10V
VCG
50mA
L
MPA 152 Plus
R
INPUTS
OUTPUTS
REMOTE
1
MODEL 80
FLAT PANEL
PUSH PUSH
POWER GUIDE MENU RES 480 480p 720p 1080i 1080p
DIRECTV HD
SELECT
DIRECTV
PC
LAPTOP
DVD
DOC CAM
AUXILIARY
DISPLAY ON
DISPLAY OFF
MUTE
VideoMore
DVD
C
ombine
d
Combined
TCP/IP
Network
Ethernet/PoE
EthernetEthernet
IR
RS-232
Volume Control
Ethernet
Extron
IPCP Pro 250
IP Link Pro
Control Processor
Extron
TLP Pro 320M
3.5" Wall Mount
TouchLink Pro Touchpanel
Digital Input
Motion Sensor
Media PlayerSatellite Receiver
Flat Panel Display
Extron
MPA 152 Plus
Power Amplier
Audio
Audio
Video
Video
AudioAudio
Extron
SI 26CT
Two-Way Ceiling
Speakers
Figure 1. TLP Pro 320M Application Diagram
Requirements
Software
For a complete list of the requirements for running GUI Designer, Global Configurator Plus and
Professional, or Toolbelt, see the Extron Web page for the appropriate software.
NOTE: The TLP Pro 320M is not compatible with GlobalConfigurator 3 or
GUIConfigurator.
Hardware
An Extron IP Link Pro control interface must also be connected to the same network domain
as the TouchLink panel. See www.extron.com for a list of suitable controllers.
NOTE: These touchpanels are not compatible with Extron IP Link (non-Pro) controllers.
TLP Pro 320M • Introduction 2
Installation
Overview
1. Before starting, download and install the latest versions of the following software:
GUI Designer — for designing layouts for Extron TouchLink Pro touchpanels and
third party touch interfaces.
Global Configurator Plus and Professional — for setting up and configuring the
control processor and touchpanel.
Toolbelt — provides device discovery, device information, firmware updates,
and configuration of network settings, system utilities, and user management for
TouchLink Pro devices.
See Configuration Software on page 20.
2. Obtain the following network information from your network administrator:
DHCP status (on or off). If DHCP is off, you will also require
IP address
Subnet mask
Gateway
User name — by default, these are either admin or user.
Passwords — by default, these are either extron (for admin) or the field is left blank
(for user).
MAC address — make a note of the touchpanel MAC address.
3. Mount and connect cables to the units:
ATTENTION:
Do not power on the touchpanels or control processors until you have read
the Attention notice on page 8 (12 VDC power supply) or on page 10 (power
injector).
Ne branchez pas les écrans tactiles ou les contrôleurs avant d’avoir lu les mises
en garde page8 (source d’alimentation 12VCC) ou page10 (injecteur PoE).
Mount the units. There are several mounting options for Touchlink Pro touchpanels
(see Mounting on page 24).
Connect cables to the touchpanels (see TLP Pro 320M Rear Panel Features on
page 7).
Connect the power cords and power on all devices (see Power connector on
page7 or Network and Power Injector Connector on page 9).
4. Set up the Touchpanels for Network Communication:
Connect the PC that you will use for setup, the control processor, and the touchpanel
to the same Ethernet subnetwork.
Use the Setup Menu (see page 11) or Toolbelt to set the DHCP status and, if
necessary, the IP address, subnet mask, gateway, and related settings for the
touchpanel.
TLP Pro 320M • Installation Overview 3
5. Configure the Touchpanels — the Global Configurator Help File, the Toolbelt Help File,
and the GUI Designer Help File provide step-by-step instructions and detailed information.
The Global Configurator Help File includes an introduction to that software and sections
on how to start a project and configuration.
TLP Pro 320M • Installation Overview 4
Panel Features
This section describes:
TLP Pro 320M Front Panel Features
TLP Pro 320M Front Panel Features (Bezel Removed)
TLP Pro 320M Rear Panel Features
TLP Pro 320M Front Panel Features
AA
B
B
D
D
B
B
E
E
CC
FF
F
F
Figure 2. TLP Pro 320M Front Panel with Bezel
A
LCD screen — the 3.5 inch LCD touchscreen has a 320x240 resolution and 18-bit color
depth.
B
Status lights — one on each side can be programmed to provide system feedback.
Light red or green
Blink or light continuously
C
Bezel — can be removed to reveal other front panel features (see the following page).
D
Backlit buttons — eight buttons are back-lit by LEDs. The buttons provided with the
touchpanel are Laptop, PC, DVD, Doc Cam, Auxiliary, Display Off, Display On,
and Mute. You can replace any of the buttons to customize your touchpanel (see Button
Replacement on page 27).
The buttons must be configured with GlobalConfigurator Plus and Professional (see the
GlobalConfiguratorHelp File).
E
Volume control knob — for controlling volume but can be configured for other functions.
F
Notches — used to remove the bezel from the touchpanel. These cannot be seen from
the front of the touchpanel. They are on the bottom surface of the bezel, where it comes in
contact with the wall.
TLP Pro 320M • Panel Features 5
TLP Pro 320M Front Panel Features (Bezel Removed)
To release the bezel from the TLP Pro 320M, use the Extron removal tool:
1. Insert the flat edge of the tool into either of the notches in the bottom surface of the bezel
(see figure 2,
F
).
2. Gently, twist the tool so that the bezel separates from the touchpanel.
3. Move the tool along the edge of the bezel and repeat step 2 until the bezel is completely
detached from the touchpanel.
AABBCC
F
FDD
D
D
EE
Figure 3. TLP Pro 320M Front Panel without Bezel
A
Motion sensor — detects motion between 3 to 5 feet from the touchpanel and at least
15° from the center axis.
When no motion has been detected for a user-defined period of time, the screen
display enters into sleep mode.
When motion is detected by the sensor, the screen display is restored and active.
B
Communication LED — shows the configuration and connection status of the
touchpanel:
Unlit during normal operation (the touchpanel is configured and connected to an
IPLink Pro control processor).
Blinks red if the touchpanel has been configured but is not connected to an
IPLinkPro control processor.
Permanently lit if the touchpanel has not been configured.
Use the setup menu (see page 11) to toggle the indicator between enabled and disabled.
C
Ambient light sensor — monitors ambient light level and adjusts screen brightness,
based on the settings configured using the setup menu (see page 11).
D
Holes for mounting the touchpanel — allow the touchpanel to be attached to the
wall-plate adapter during mounting (see page 24).
E
Speaker — one placed below the screen provides audible feedback from button presses.
F
Menu button — activates the setup menu (see page11).
TLP Pro 320M • Panel Features 6
TLP Pro 320M Rear Panel Features
AA
B
B
C
C
D
D
Figure 4. TLP Pro 320M Rear Panel Features
A
Power connector — Connect this 2-pole, 3.5 mm captive screw receptacle to a
12VDC, 1.0 A power supply (not provided). Extron recommends the PS 1210C power
supply (part number 70-775-01).
Ensure the connections have the correct polarity as shown below.
WARNING: The two power cord wires must be kept separate while the power
supply is plugged in. Remove power before wiring.
AVERTISSEMENT : Les deux cordons d’alimentation doivent être tenus à l’écart
l’un de l’autre quand l’alimentation est branchée. Couper l’alimentation avant de faire
l’installation électrique.
ATTENTION:
Do not power on the touchpanels or control processors until you have read
the Attention notice on page 8 (12 VDC power supply) or on page 10 (power
injector).
Ne branchez pas les écrans tactiles ou les contrôleurs avant d’avoir lu les mises
en garde page8 (source d’alimentation 12VCC) ou page10 (injecteur PoE).
NOTE: The TLP Pro 320M ships without a power supply. Either the 12 VDC power
supply or the power injector must be purchased separately.
Power Receptacle
Captive Screw Connector
AC Power Cord
Ground
+12 VDC
External
Power Supply
(12 VDC, 1 A )
SECTION A–A
Ridges
Smooth
Power Supply
Output Cord
AA
3/16"
(5 mm) Max.
+
POWER
12V
1.0A MAX
+
POWER
12V
1.0A MAX
Figure 5. Power Supply Connection
A
Power connector
B
Reset button
C
Reset LED
D
Network and Power over
Ethernet (PoE) Connector
TLP Pro 320M • Panel Features 7
ATTENTION:
Always use a power supply provided by or specified by Extron. Use of an
unauthorized power supply voids all regulatory compliance certification and may
cause damage to the supply and the end product.
Utilisez toujours une source d’alimentation fournie ou recommandée par Extron.
L’utilisation d’une source d’alimentation non autorisée annule toute conformité
réglementaire et peut endommager la source d’alimentation ainsi que le produit final.
This product is intended for use with a UL Listed power source marked “Class 2” or
“LPS” and rated 12VDC, minimum 1.0 A. or 48 VDC (PoE), minimum 0.35 A.
Ce produit est destiné à une utilisation avec une source d’alimentation listéeUL
avec l’appellation «Classe2» ou «LPS» et normée 12Vcc, 1,0A minimum ou
48Vcc(PoE), 0,35A minimum.
Extron power supplies are certified to UL/CSA 60950-1 and are classified as LPS
(Limited Power Source). Use of a non-LPS or unlisted power supply will void all
regulatory compliance certification.
Les sources d’alimentation Extron sont qualifiées UL/CSA60950-1 et sont
classéesLPS(LimitedPowerSource). L’utilisation d’une source d’alimentation non-
listée ou non-listéeLPS annulera toute certification de conformité réglementaire.
Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling
spaces or in wall cavities. The power supply is to be located within the same vicinity
as the Extron AV processing equipment in an ordinary location, Pollution Degree 2,
secured to the equipment rack within the dedicated closet, podium, or desk.
Sauf mention contraire, les adaptateurs AC/DC ne sont pas appropriés pour une
utilisation dans les espaces d’aération ou dans les cavités murales. La source
d’alimentation doit être située à proximité de l’équipement de traitement audiovisuel
dans un endroit ordinaire, avec un degré2 de pollution, fixé à un équipement de rack
à l’intérieur d’un placard, d’une estrade, ou d’un bureau.
The installation must always be in accordance with the applicable provisions of
National Electrical Code ANSI/NFPA 70, article 725 and the Canadian Electrical Code
part 1, section 16.
Cette installation doit toujours être en accord avec les mesures qui s’applique au
National Electrical Code ANSI/NFPA70, article725, et au Canadian Electrical Code,
partie1, section16.
The power supply shall not be permanently fixed to building structure or similar
structure.
La source d’alimentation ne devra pas être fixée de façon permanente à une structure
de bâtiment ou à une structure similaire.
The length of the exposed wires in the stripping process is critical. The ideal length is
3/16 inches (5 mm). Any longer and the exposed wires may touch, causing a short
circuit between them. Any shorter and the wires can be easily pulled out even if tightly
fastened by the captive screws.
La longueur des câbles exposés est primordiale lorsque l’on entreprend de les
dénuder. La longueur idéale est de 5mm (3/16inches). S’ils sont un peu plus longs,
les câbles exposés pourraient se toucher et provoquer un court circuit. S’ils sont un
peu plus courts, ils pourraient sortir, même s’ils sont attachés par les vis captives.
Do not tin the wire leads before installing into the connector. Tinned wires are not as
secure in the connector and could be pulled out.
Ne pas étamer les conducteurs avant de les insérer dans le connecteur. Les câbles
étamés ne sont pas aussi bien fixés dans le connecteur et pourraient être retirés.
B
Reset button (see figure 4 on page 7) — is in the recessed hole to the left of the
Reset LED. Pressing this button initiates one of three reset modes for the unit (see
Reset Modes on page 30).
TLP Pro 320M • Panel Features 8
C
Reset LED (see figure 4 on page 7)— is in the center of the rear panel, to the right of the
reset button. It indicates power status and reset status of the device (see Reset Modes
on page 30).
D
Network and Power Injector Connector (see figure 4 on page 7) — is on the right
side of the recessed area.
Connect the touchpanel to the LAN using a twisted pair cable, terminated with an RJ-45
connector. Use a straight-through Ethernet cable to connect the panel to a switch or
router. Use a crossover cable to connect the panel directly to a computer.
An Extron IPL Pro Control Processor must also be connected to the same network
domain as the TouchLink Pro touchpanel. See the www.extron.com for a list of
suggested models.
The network port has two LEDs. The green LED lights steadily to indicate that the
touchpanel is connected correctly to a network. The yellow LED flashes to indicate that
data is being passed to or from the touchpanel.
The connector can also be used with a power injector (not provided). Extron recommends
using the XTP PI 100 power injector (part number 60-1233-01), which is shown in figure6
below.
ATTENTION:
The TLP Pro 320M can use a 12 VDC desktop power supply and is also Power
over Ethernet (PoE 802.3af, class3) compliant. Do not connect either power
supply before reading the Attention notifications on page 8 or page 10.
Le TLP Pro 320M peut utiliser une source d’alimentation externe 12 Vcc, et
est également compatible avec l’alimentation POE via Ethernet (PoE802.3af,
classe3). Ne branchez pas de sources d’alimentation externes avant d’avoir lu
les mises en garde dans la section «PowerSupply» sur page8 ou page10.
To use a power injector — connect a straight-through Ethernet cable to the power
supply and a switch or router. This cable carries network information from the switch or
router to the power supply input. A second straight-through cable carries the network
information and 48VDC from the power supply to the touchpanel. Connect the IEC power
cord to a convenient 100 VAC to 240 VAC, 50-60 Hz power source.
The figure below shows the Extron XTP PI 100. Your power injector may look different.
100-240V
~
50-60Hz
0.4A MAX
XTP
PWR
XTP PWR
To network switchTo TLP PRO 320M
Figure 6. Connecting the Power Injector
TLP Pro 320M • Panel Features 9
ATTENTION:
The TLP Pro 320M is intended for connection to a Power over Ethernet circuit for
intra-building use only and are considered to be part of a Network Environment 0 per
IEC TR62101.
Le TLP Pro 320M est conçu pour une connexion à un circuit PoE pour une utilisation
intérieure seulement et est considéré comme faisant partie d’un environnement réseau
0 par IECTR62101.
Always use a power supply provided by or specified by Extron. Use of an
unauthorized power supply voids all regulatory compliance certification and may
cause damage to the supply and the end product.
Utilisez toujours une source d’alimentation fournie ou recommandée par Extron.
L’utilisation d’une source d’alimentation non autorisée annule toute conformité
réglementaire et peut endommager la source d’alimentation ainsi que le produit final.
This product is intended for use with a UL Listed power source marked “Class 2” or
“LPS” and rated 12VDC, minimum 1.0 A. or 48 VDC (PoE), minimum 0.35 A.
Ce produit est destiné à une utilisation avec une source d’alimentation listéeUL avec
l’appellation «Classe2» ou «LPS» et normée 12Vcc, 1,0A minimum ou 48Vcc
(PoE), 0,35A minimum.
Extron power supplies are certified to UL/CSA 60950-1 and are classified as LPS
(Limited Power Source). Use of a non-LPS or unlisted power supply will void all
regulatory compliance certification.
Les sources d’alimentation Extron sont qualifiées UL/CSA60950-1 et sont
classéesLPS(LimitedPowerSource). L’utilisation d’une source d’alimentation non-
listée ou non-listéeLPS annulera toute certification de conformité réglementaire.
Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling
spaces or in wall cavities. The power supply is to be located within the same vicinity
as the Extron AV processing equipment in an ordinary location, Pollution Degree 2,
secured to the equipment rack within the dedicated closet, podium, or desk.
Sauf mention contraire, les adaptateurs AC/DC ne sont pas appropriés pour une
utilisation dans les espaces d’aération ou dans les cavités murales. La source
d’alimentation doit être située à proximité de l’équipement de traitement audiovisuel
dans un endroit ordinaire, avec un degré2 de pollution, fixé à un équipement de rack
à l’intérieur d’un placard, d’une estrade, ou d’un bureau.
Power over Ethernet (PoE) is intended for indoor use only. It is to be connected only to
networks or circuits that are not routed to the outside plant or building.
L’alimentation via Ethernet (PoE) est destinée à une utilisation en intérieur uniquement.
Elle doit être connectée seulement à des réseaux ou des circuits qui ne sont pas
routés au réseau ou au bâtiment extérieur.
The installation must always be in accordance with the applicable provisions of
National Electrical Code ANSI/NFPA 70, article 725 and the Canadian Electrical Code
part 1, section 16.
Cette installation doit toujours être en accord avec les mesures qui s’applique au
National Electrical Code ANSI/NFPA70, article725, et au Canadian Electrical Code,
partie1, section16.
The power supply shall not be permanently fixed to building structure or similar
structure.
La source d’alimentation ne devra pas être fixée de façon permanente à une structure
de bâtiment ou à une structure similaire.
TLP Pro 320M • Panel Features 10
Setup Menu
When the TLP Pro 320M is powered on, the currently loaded project is displayed. To access
the setup menu, remove the front panel bezel and press the Menu button (see figure 3
F
, on
page 6). There are five available screens:
Status
Network
Display
Audio
Advanced
To navigate between different screens, press the
Menu icon in the top left corner.
The screen selection menu opens over the current screen, which is grayed out. The
menu has five buttons, corresponding to the five available screens:
Status
Exit
INFO
Model
Part Number
Firmware Version
PoE
TLP Pro 320M
60-1451-02
1.00.0010.b004
Active
NETWORK
DHCP Off
INF
O
M
o
d
e
l
P
art
N
um
b
er
Fi
rmw
a
r
e
Ve
r
sio
n
o
TLP
P
ro 320
M
60
-
14
5
1
-
02
1.
00
.
00
1
0
.
b00
4
A
ct
i
v
e
NETWORK
D
HCP
O
ff
Network
Display
Audio
Advanced
Status
Figure 7. Screen Selection Menu
The button for the screen that is currently selected is yellow with black text. The other screens
are gray with white text.
Press the name of the screen you wish to open.
There is also a red
Exit button in the top right corner of the screen. Press this button to apply
and save any changes and to close the menu screens.
TLP Pro 320M • Setup Menu 11
Status Screen
This screen opens by default. To access the Status screen from any other part of the Setup
menu, press the
Menu icon in the top left corner and then press the Status button.
The image below shows the entire
Status screen. Because of size of the touchscreen, you
can only see part of the
Status screen at any time. Flick the touchscreen with your finger to
navigate up or down within the screen.
Status
Exit
INFO
Model:
Part Number:
Firmware Version:
PoE:
TLP Pro 320M
60-1451-02
1.03.0000.b001
Active
NETWORK
DHCP:
Hostname:
IP Address:
TLP-Pro-320M-AB-CD-EF
192.168.254.251
DISPLAY
Screen Resolution: 320x240
Sleep Timer: 5 Minutes
AUDIO
Master Volume: 80
Master Mute: Off
ADVANCED
Controller IP: 192.168.254.250
Storage Usage: 1/151 MB
Bootloader Version: 1.03.0000
Off
Figure 8. Status Screen
The
Status screen is a read-only screen that provides basic information about the
touchpanel. Each section of the screen shows a summary of the information on the other
screens. More information about each topic can be found on the Network, Display, Audio,
and Advanced screens. To navigate to the appropriate screen, click the light gray bar for that
screen. Alternatively, you can use the Menu icon in the top left corner.
The bubble in the
Network panel is green when there is a network connection or amber if
there is no connection. The bubble in the Advanced panel is green when a control processor
is connected or amber if none is connected.
TLP Pro 320M • Setup Menu 12
Network Screen
The image below shows the entire Network screen. Because of size of the touchscreen, you
can only see part of the screen at any time. Flick the touchscreen with your finger to navigate
up or down within the screen.
Network
Exit
NETWORK SETTINGS
DHCP:
Hostname:
IP Address:
Subnet Mask:
TLP-Pro-320M-AB-CD-EF
Gateway:
DNS Server:
Domain Name:
00-05-A6-AB-CD-EFMAC Address:
X
192.168.254.251
255.255.255.0
0.0.0.0
127.0.0.1
Revert Apply
Figure 9. Network Screen
The
Domain Name (optional) and MAC Address are read-only.
Verify with your network administrator whether the network settings for the touchpanel are
assigned by Dynamic Host Configuration Protocol (DHCP) or set manually. If they are set
manually, obtain an IP address, a subnet mask, a gateway address, and a Domain Name
Server (DNS) IP address from the network administrator.
1. If IP addresses are assigned manually, press the DHCP slider so that it is in the
Off position. When the slider is off, the
IP Address, Subnet Mask, Gateway,
and DNS Server values can all be edited (they are shown as white text on a
gray button that can be pressed. There is an arrowhead next to the text on each
button).
If IP addresses are assigned by DHCP, Press the
DHCP slider so that it is in the
On position. When the slider is on, the IP Address, Subnet Mask, Gateway,
and
DNS Server values cannot be edited (they are shown in white text, with no
button and no arrowhead). Only the Host Name can be edited.
TLP Pro 320M • Setup Menu 13
2. Edit the IP Address by pressing the appropriate text box on the Network screen.
A numeric keypad opens with the current IP address displayed (
1
):
12 3
4
7
.
56
89
0
Cancel
Ok
X
X
IP Address
192.168.254.251
11
2
2
3
3
4
4
5
5
Figure 10. Numeric Keyboard
a. To delete the entire existing number, press the white circle with an X (
2
).
To delete individual digits, use the backspace key (
3
).
b. Enter the IP address by pressing the numbered keys. You must also enter the
period between each octet.
The value for any individual octet must be between 0 and 255. You cannot enter
an invalid number. For example, if you attempt to enter 401, you will be able to
enter the 4 and the 0, but you will not be able to enter the 1.
c. Press Ok (
5
) to save your changes and close the keypad.
Press Cancel (
4
) to close the keypad without saving any changes.
d. When you save changes, you return to the Network screen. The Apply and
Revert buttons turn red.
Press Apply to keep the changes that you have made.
Press Revert to go back to the previous IP address.
3. Repeat step 2 to update the Subnet Mask, Gateway, or DNS Server values, as
required.