Shinko SGJW User manual

Type
User manual

This manual is also suitable for

S G J - F - 0 -
Option
0: No option needed, 1: Multi-rotation trimmer
2: Moisture-proof treatment
3: Multi-rotation trimmer+Moisture-proof treatment
Power supply
100 to 240 V AC
Output 2 (For SGJW only)
Output 1
Input
Series name
SGJ: 1-output, SGJW: 2-outputs
SGJL: 1-output + Serial communication
(For detailed input/output spec, refer to the full Instruction Manual.)
Default Display
Custom display
mode 3
Custom display
mode 4
Unlit
display mode
All unlit
display mode
Model display
mode
RUN display
mode 1
DISP
key
RUN display
mode 2
RUN display
mode 3
RUN display
mode 4
RUN display
mode 5
RUN display
mode 6
Custom display
mode 1
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
Custom display
mode 2
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
MODE
key
for 5 sec
MODE
key
Frequency
range group
I
nput
setting
mode
O
utput
1
setting
mode
O
utput
2
setting
mode
I
nstrument
setting
mode
Communication
setting
mode
C
display
setting mode
Manual mode
DOWN
key
for 3 sec
DISP
key
for 3 sec
DISP
key
Frequency
high limit
DISP
key
Decimal
point place
DISP
key
I
ndication
value for
input low limit
DISP
key
I
ndication
value for
input high limit
DISP
key
Indication
unit
DISP
key
Save
settings
DISP
key
Output 1
type
O
decimal
point place
Indication
value at
output 0%
Indication
value at
output 100%
S
hutdown
threshold
value
Output value
at shutdown
O
Normal/
Reverse
Save
settings
Output 2
type
O
decimal
point place
Indication
value at
output 0%
Indication
value at
output 100%
S
hutdown
threshold
value
Output value
at shutdown
O
Normal/
Reverse
Save
settings
Indication
time
Auto/Manual
M
anual mode
auto return
time
Save
settings
Instrument
number
Communication
speed
Data bit/
Parity
Stop bit
Response
delay time
Save
settings
Multi-Display
A
Multi-Display
B
Save
settings
Default DisplayDefault Display
Default Display
Default Display
Default Display
Default Display
MODE
k
ey, or after
Manual mode auto return
time has elapsed.
DISP
key
DISP
key
DISP
key
DISP
key
for 3 sec
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
for 3 sec
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
MODE
key
MODE
key
MODE
key
MODE
key
MODE
key
DISP
key
for 3 sec
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
for 3 sec
DISP
key
DISP
key
DISP
key
DISP
key
for 3 sec
No.
1
No. 6
No.
1
No.
6
No. 1 COM
No. 2 NC
No. 3 YB(+)
No. 4 YA(-)
No. 5 NC
No.
6
COM
QUICK REFERENCE [Applicable model: SGJ, SGJW, SGJL] No.SGJ12JE1 2018.10
Frequency range group
Ultra-low frequency
Low frequency
Frequency
Decimal point place
No decimal point
1 digit after point
2 digits after point
3 digits after point
Indication unit
No unit
%
mA
V
°C
Save settings
Save
Not save
Output 1, Output 2 type
4 to 20 mA
0 to 20 mA
0 to 16 mA
2 to 10 mA
0 to 10 mA
0 to 10 mV
0 to 100 mV
0 to 1 V
0 to 5 V
1 to 5 V
0 to 10 V
-5 to 5 V
1
Output 1,2 decimal point place
No decimal point
1 digit after point
2 digits after point
3 digits after point
Output 1,2 Normal/Reverse
Normal
Reverse
Auto/Manual
Auto
Manual
Communication speed
9600 bps
19200 bps
38400 bps
Data bit/Parity
8 bits/No parity
8 bits/Even
8 bits/Odd
Stop bit
1 bit
2 bits
S
election It
em List
Model Name
Circuit Configuration
SGJ, SGJL
Setting Mode
Output 2 setting mode is available only for the SGJW.
Communication setting mode is available only for the SGJL.
If the MODE key is pressed for approx. 5 seconds in each setting mode,
the unit will move to the Default Display.
SGJW
Characters
Indication
Number, °C/°F -1 0 1 2 3 4 5 6 7 8 9 °C °F
Indication
A
lphabet A B C D E F G H I J K L M
Indication
A
lphabet N O P Q R S T U V W X Y Z
Terminal Arrangement
SGJ SGJW SGJL only
RS-485 serial communication
Modular jack pin arrangement
Key Operation Flowchart
Display Mode
: Available only for the SGJW.
For the details of the display mode, refer to the full Instruction Manual.
Default Display
If the MODE and DISP keys (in that order) are pressed together for approx. 3
seconds in any display mode, the display mode will become the Default Display.
Once the Default Display is set, the DISP key will be in lock status.
If the DISP key is pressed for approx. 3 seconds, the key lock status will be
cancelled.
If the DISP key is pressed while the DISP key is in lock status, Multi-Display A
will indicate
.
1 Not available for the SGJW.
和文は裏面をご覧下さい。
Output
circuit
Communi-
cation circuit
Modular
jack
CPU
Input
circuit
Front
trimmer
Power
circuit
Display/
Setting key
circuit
+
-
+
-
For SGJL
Fixed voltage
circuit 12V
+
Input
Power for
sensor
1
4
5
9
13
14
12
Output 1
circuit
CPU
Input
circuit
Front
trimmer
Power
circuit
Display/
Setting key
circuit
-
+
-
Fixed voltage
circuit 12V
+
Input
Power for
sensor
Output 2
circuit
+
-
+
1
2
4
6
3
7
8
10
11
  • Page 1 1

Shinko SGJW User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI