Shinko Quick Reference User manual

Type
User manual

This manual is also suitable for

S G R - - -
Option
0: No option needed, 1: Multi-rotation trimmer
2: Moisture-proof treatment
3: Multi-rotation trimmer+Moisture-proof treatment
Power supply
0: 100 to 240 V AC, 1: 24 V AC/DC
*2
Output 2
*1
Output
*2
, Output 1
*1
Input
Series name
SGR: 1-output, SGRW: 2-outputs
SGRL: 1-output + Serial communication
*1: SGRW only
*2: SGR, SGRL only
(
For detailed input
/output spec, refer to the full Instruction Manual.
)
Default Display
Custom display
mode 3
Custom display
mode 4
Unlit
display mode
All unlit
display mode
Model display
mode
RUN display
mode 1
DISP
key
RUN display
mode 2
RUN display
mode 3
RUN display
mode 4
RUN display
mode 5
RUN display
mode 6
Custom display
mode 1
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
Custom display
mode 2
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
MODE
key
for 5 sec
MODE
key
Input
setting mode
Output 1
setting mode
Output 2
setting mode
Instrument
setting mode
Communication
setting mode
C
ustom
display
setting mode
Manual mode
DOWN
key
for 3 sec
DISP
key
for 3 sec
Input type
DISP
key
Input unit
DISP
key
Decimal
point place
DISP
key
Output 0%
value
DISP
key
Output
100% value
DISP
key
Indication
unit
DISP
key
Save
settings
DISP
key
Output 1
type
O
1
decimal
p
oi
nt place
Indication
value at
output 0%
Indication
value at
output 100%
Output 1
low limit
Output 1
high limit
Output 1
Normal/Reverse
Save
settings
Output 2
type
O
2
decimal
p
oi
nt place
Indication
value at
output 0%
Indication
value at
output 100%
Output 2
low limit
Output 2
high limit
Output 2
Normal/Reverse
Save
settings
Filter time
constant
Sensor
correction
I
nput
burnout
status
Indication
time
Auto/Manual
Manual mode
auto return time
Save
settings
Instrument
number
Communication
speed
Data bit/
Parity
Stop bit
Response
delay time
Save
settings
Multi-Display
A
Multi-Display
B
Save
settings
Default DisplayDefault Display
D
efault Display
Default Display
Default Display
Default Display
MODE
k
ey, or after
Manual m
ode auto return
time has elapsed
DISP
key
DISP
key
DISP
key
DISP
key
for 3 sec
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
for 3 sec
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
MODE
key
MODE
key
MODE
key
MODE
key
MODE
key
DISP
key
for 3 sec
DISP
key
D
ISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
DISP
key
for 3 sec
DISP
key
DISP
key
DISP
key
DISP
key
for 3 sec
No.
1
No. 6
No.
1
No.
6
No. 1 COM
No. 2 NC
No. 3 YB(+)
No. 4 YA(-)
No. 5 NC
No.
6
COM
QUICK REFERENCE [Applicable model: SGR, SGRW, SGRL] No.SGR12JE1 2018.10
Input type
Pt100
-200 to 650 °C
Pt100
-100 to 100 °C
JPt100
-200 to 500 °C
JPt100
-100 to 100 °C
Input unit
°C
°F
Decimal point place
No decimal point
1 digit after point
Indication unit
No unit
%
mA
V
°C
Save settings
Save
Not save
Output 1, Output 2 type
4 to 20 mA
0 to 20 mA
0 to 16 mA
2 to 10 mA
0 to 10 mA
0 to 10 mV
0 to 100 mV
0 to 1 V
0 to 5 V
1 to 5 V
0 to 10 V
-5 to 5 V
1
Output 1,2 decimal point place
No decimal point
1 digit after point
2 digits after point
3 digits after point
Output 1,2 Normal/Reverse
Normal
Reverse
Input burnout status
Overscale
Underscale
Auto/Manual
Auto
Manual
Communication speed
9600 bps
19200 bps
38400 bps
Data bit/Parity
8 bits/No parity
8 bits/Even
8 bits/Odd
Stop bit
1 bit
2 bits
Selection Item List
Model Name
Circuit Configuration
SGR, SGRL
Setting Mode
Output 2 setting mode is available only for the SGRW.
Communication setting mode is available only for the SGRL.
If the MODE key is pressed for approx. 5 seconds in each setting
mode, the unit will move to the Default Display.
SGRW
Characters
Indication
Number, °C/°F -1 0 1 2 3 4 5 6 7 8 9 °C °F
Indication
Alphabet
A B C D E F G H I J K L M
Indication
Alphabet
N O P Q R S T U V W X Y Z
Terminal Arrangement
SGR, SGRL SGRW SGRL only
RS-485 serial communication
Modular jack pin arrangement
Key Operation Flowchart
Display Mode
: Available only for the SGRW.
For the details of the display mode, refer to the full Instruction Manual.
Default Display
If the MODE and DISP keys (in that order) are pressed together for approx. 3
seconds in any display mode, the display mode will become the Default Display.
Once the Default Display is set, the DISP key will be in lock status.
If the DISP key is pressed for approx. 3 seconds, the key lock status will be
cancelled.
If the DISP key is pressed while the DISP key is in lock status, Multi-Display A
will indicate
.
1 Not available for the SGRW.
For SGRL
和文は裏面をご覧下さい。
Output
circuit
Commu
-
nication
circuit
Modular
jack
CPU
Input
circuit
Front
trimmer
Power
circuit
Display/
Setting
key circui
t
g key
RTD
A
B
B
+
-
1
4
5
9
13
14
12
Output 1
circuit
Output 2
circuit
CPU
Input
circuit
Front
trimmer
Power
circuit
Display/
Setting
key circui
t
g key
RTD
A
B
B
+
-
+
-
1
2
4
6
3
7
8
10
11
  • Page 1 1

Shinko Quick Reference User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI