Blue Sea Systems 7635 Operating instructions

Type
Operating instructions

Blue Sea Systems 7635 is a Low Voltage Disconnect (LVD) device that helps to preserve battery life and prevent starting issues by automatically disconnecting non-critical devices when the battery voltage drops below a preset level. The device features a Remote Control Switch that allows for manual override, temporary disconnection, and alarm silencing. The LVD also includes an alarm output for connecting an external audible warning device, providing an early indication of impending low voltage conditions.

Blue Sea Systems 7635 is a Low Voltage Disconnect (LVD) device that helps to preserve battery life and prevent starting issues by automatically disconnecting non-critical devices when the battery voltage drops below a preset level. The device features a Remote Control Switch that allows for manual override, temporary disconnection, and alarm silencing. The LVD also includes an alarm output for connecting an external audible warning device, providing an early indication of impending low voltage conditions.

CAUTION symbol refers to a potentially hazardous situation which, if not avoided, may
result in minor or moderate injury.
WARNING symbol refers to a potentially hazardous situation which, if not avoided, may
result in death or serious injury.
Instructions
PN 7635 / 7635B
Blue Sea Systems Inc. p 360.738.8230
4600 Ryzex Way f 360.734.4195
Bellingham, WA 98226 USA www.bluesea.com
980016770 Rev.003
WARNING
CAUTION
Installation
GUARANTEE: Blue Sea Systems stands behind its products for as long
as you own them. Find detailed information at www.bluesea.com/about.
For customer service, call 800-222-7617.
Senses low battery voltage and automatically disconnects
devices to save power for starting or to preserve battery life
Status light in both m-LVD and Remote Control Switch provides visual warning of low
voltage state prior to disconnect
Alarm output available for audible warning of low voltage state
prior to disconnect (optional alarm required)
Remote Control Switch Functions:
Disconnect Voltage Adjustment - Sets desired disconnect voltage
Override - Temporarily delays circuit disconnect for 10 minutes
OFF - Temporarily disconnects circuits until voltage rises
Override or OFF - Silences alarm (optional alarm required)
Includes Remote Control Switch PN 7928
DC
AC
Before beginning electrical installation, disconnect all AC and DC power sources.
Do not service equipment that has been automatically disconnected by the m-LVD
withoutrstpermanentlyremovingpowerfromtheequipmentbyameansother
than the m-LVD.
WARNING
CAUTION
If you are not knowledgeable about electrical systems, consult an electrical professional.
Mount the m-LVD. Three mounting options are illustrated below:
1.00
"
(25.4mm)
SUGGESTED
MINIMUM SCREW
LENGTH
#10 SCREWS
WITH THREAD
APPROPRIATE
FOR MOUNTING
SURFACE
2-5/8" (66.7mm)
MOUNTING HOLE
DIAMETER
5/16" (7.9mm)
MAXIMUM PANEL
THICKNESS
2-5/16" (58.7mm)
MOUNTING HOLE
DIAMETER
1.00
" (25.4mm)
SUGGESTED SCREW
LENGTH FOR 1/8"
PANEL THICKNESS
#10 HEX NUTS
3/8" WIDTH
#10 MACHINE
SCREWS
2.25 (57.2mm)
SUGGESTED MINIMUM
SCREW LENGTH
#10 SCREWS
WITH THREAD
APPROPRIATE
FOR MOUNTING
SURFACE
Rear Panel Mount
Front Panel Mount
Surface Mount
Front Panel Mount (Rear View)
m -LVD
LOW VOLTAGE DISCONNECT
Scan for
additional
product
information
1.45"
(36.83mm)
0.83"
(21.08mm)
Remote Control Switch
Mounting Hole Dimensions
Intermittent Rating: 5 min. 115A
Continuous Rating 65A
Nominal Voltage 12V DC
Cable Size (to meet current ratings) 6 AWG (16mm²)
Terminal Stud Size 1/4"-20 (M6)
Disconnect Voltage 11.3V12.1V Adjustable
Factory Default Disconnect Voltage 12.1V
Time Delay to Alarm The unit waits 5 mins after the
voltage goes below the set point before
it starts the warning. Then an additional
5 mins to disconnect, 10 mins total.
Alarm Time Before Disconnect 5 mins
Reconnect Voltage 13V DC
Remote Control Switch Type: SPDT, Action: (ON)-OFF-(ON)
( ) = momentary
Maximum Alarm Current 250mA
Maximum External LED Current 14mA
Regulatory
ISO 8846, Meets SAE J1171 external ignition protection requirements
Specications
Installation (continued)
Remove rear insulating cover as illustrated.
Installation Diagram
COMMON BUSBAR
REMOTE
CONTROL
SWITCH
OPTIONAL
ALARM
STEREO OR OTHER
12V DC DEVICES
BATTERY
LED OUTPUT
OPTIONAL BATTERY SWITCH
Required if
the battery is
over 800 Cold
Cranking Amps (CCA)
ALARM OUTPUT
1
2
3
8 7
4
5
6
10A FUSE
FUSE*
See Wire Size
and Fuse
Rating Chart
above
FUSE
Connection Legend
DC Positive
DC Negative (Ground)
Optional
Control
+
-
NEG
POS
FUSE
m-LVD Connections
Function
A Battery
B Load
1 Ground
2 Remote Switch
3 Alarm Output
4 LED Output
The Installation Diagram illustrated below represents a common installation and is
not meant to be a guide for wiring a specic vessel.
Caution: Disconnect battery connections before beginning the installation.
Reconnect after the installation is complete.
Use the wire sizing chart below to select the appropriate wire sizes. Consult an
ABYC certied electrician for proper fuse placement and sizing.
* Larger wire sizes may be required to minimize voltage drop in long wire runs.
For more information please use the Circuit Wizard at www.circuitwizard.bluesea.com.
Wire Size and Fuse Rating Chart*
Amps Min. Wire Size* (AWG) Fuse Rating Min. Wire Size* (Metric)
≤30 #10 40A-50A 6 mm²
≤50 #8 60A-65A 10 mm²
≤65 #6 90A-100A 16 mm²
Electrical Connections
m-LVD Connection Table
Disconnect Voltage Adjustment
Disconnect Voltage LED Flash Count
Factory Default:
12.1V
5
11.9V 4
11.7V 3
11.5V 2
11.3V 1
Press and hold the OVERRIDE position of the remote control
switch for 10 seconds to enter adjustment mode. Adjustment
mode can only be entered in the Connected or Disconnected
states, not in the Low Voltage Warning state. LED will
beginaashpatterntoindicatethecurrentDisconnect
voltage setting (see table below).
Disconnect Voltage Adjustment Table
Press and release OFF to decrease the Disconnect
voltagesettingin0.2Vincrementsdowntoaminimumof11.3V(1ash).
Press and release OVERRIDE to increase the Disconnect
voltagein0.2Vincrementsuptoamaximumof12.1V(5ashes).
• Whenyouaresatisedwithyourselection,releasethe switch, and wait
approximately 20 seconds, the m-LVD will save the new Disconnect
Voltage Setting, and automatically return to normal operation.
m-LVD Normal Operation Status Chart
LED Alarm Relay Status
OFF Solid OFF Closed Connected
ON Solid ON Closed Low Voltage Warning
Double Flash OFF Open Disconnected
m-LVD Normal Operation Status Chart
Operation during Low Voltage Warning or when Disconnected
Press OVERRIDE
to temporarily delay circuit disconnect for 10 minutes.
• Press OVERRIDE or OFF
to silence alarm (optional alarm required).
• Press OFF
to temporarily disconnect circuits until voltage rises.
Remote Control Switch
  • Page 1 1
  • Page 2 2

Blue Sea Systems 7635 Operating instructions

Type
Operating instructions

Blue Sea Systems 7635 is a Low Voltage Disconnect (LVD) device that helps to preserve battery life and prevent starting issues by automatically disconnecting non-critical devices when the battery voltage drops below a preset level. The device features a Remote Control Switch that allows for manual override, temporary disconnection, and alarm silencing. The LVD also includes an alarm output for connecting an external audible warning device, providing an early indication of impending low voltage conditions.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI