Design House 588053 Installation guide

Type
Installation guide

Design House 588053 is a photocell that can be used to control outdoor lighting. It is designed to turn lights on at dusk and off at dawn, providing automatic lighting control. The photocell has a built-in light sensor that detects the ambient light level and adjusts the lighting accordingly. It can be used with incandescent, fluorescent, and LED lights, and has a maximum load capacity of 1800W. The photocell is easy to install and comes with a gasket ring to ensure a waterproof seal. It is also IP54 rated, meaning it is protected against dust and water jets.

Design House 588053 is a photocell that can be used to control outdoor lighting. It is designed to turn lights on at dusk and off at dawn, providing automatic lighting control. The photocell has a built-in light sensor that detects the ambient light level and adjusts the lighting accordingly. It can be used with incandescent, fluorescent, and LED lights, and has a maximum load capacity of 1800W. The photocell is easy to install and comes with a gasket ring to ensure a waterproof seal. It is also IP54 rated, meaning it is protected against dust and water jets.

PHOTO CONTROL INSTRUCTIONS
SAFETY
Before installation or maintenance, ensure that the main power supply to the unit is switched
off
and the circuit supply fuses are removed or circuit breaker is turned off.
It is recommended that a qualified electrician is consulted or used for the installation of this
photocell and installed to the current edition of the IEE wiring regulations.
RATINGS
588079 120 2000W 2000VA UL IP54
Part Volts Tungsten Ballast Certified IP grade
TROUBLESHOOTING:
1) The load stays on:
The photocontrol is in a shady or dark position or
The neutral is not connected.
2) The load is flashing,strobing or switching on and off repeatedly through hours of darkness.
The photocontrol is too close to the light source it is controlling.
3) The load cycles in daytime.
WIRING DIAGRAM
The wiring or
line
and load is reversed.
588061
588087
588053
588095
588103
200 mm
290 mm
Note:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
588079
反面
正面
These instructions should be read carefully and retained after installation for further
reference and maintenance.
15 mm
15 mm
10 mm
Part#:588053,588061
588079,588087
588095,588103
208-277 1500W 1100VA UL IP54
208-277 2000W 2000VA UL IP54
588053 120 1800W 1100VA UL IP54
588061 120 1800W 1100VA UL IP54
588087 120 1800W 1100VA UL IP54
588095 120 1800W 1100VA UL IP54
588103 120 1800W 1100VA UL IP54
INSTALLATION
Carefully choose the correct position to install the photocontrol using the following guidelines:
1) Where possible there should be a clear view of the sky.
2) Be away from view of the light source the unit is used to control.
3) Pass the photo control eye through a16mm clearance hole and apply the gasket ring to the
inner wall of the junction box,securely fix it by using 2 locking rings positioned either side of
the hole firmly,to form a waterproof seal (Figure 1) or,pass the wires and threaded stem end
through a 20mm clearance hole from outside of a junction box and apply gasket ring to its
inner wall,and securely fix it with tighten the metal lock-nut from inside,to form a waterproof
seal(Figure 2).
4) Terminate the 3 cables observing the correct connections:-
“BLACK”=LINE(Supply In) “RED”=Load(Supply Out) “WHITE”=Neutral
These limits are designed to provide reasonable protection against harmful
interference in a residential installation.This equipment generates,uses and can
radiate radio frequency energy and,if not installedand used in accordance with the
instructions,may cause harmful interference to radio communications.However,there
is no guarantee that interference will not occur in a particular installation.If this
equipment does cause harmful interference to radio or television reception,which can
be dete rmined by turning the equipment off and on,the user is encouraged to try to
correct the interference by one or more of the following measures:
  • Page 1 1

Design House 588053 Installation guide

Type
Installation guide

Design House 588053 is a photocell that can be used to control outdoor lighting. It is designed to turn lights on at dusk and off at dawn, providing automatic lighting control. The photocell has a built-in light sensor that detects the ambient light level and adjusts the lighting accordingly. It can be used with incandescent, fluorescent, and LED lights, and has a maximum load capacity of 1800W. The photocell is easy to install and comes with a gasket ring to ensure a waterproof seal. It is also IP54 rated, meaning it is protected against dust and water jets.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI