Vigo VG6048STCL6074 Installation guide

Type
Installation guide

Vigo VG6048STCL6074 shower enclosure is a high-quality, durable product that is easy to install and maintain. The 3/8" thick tempered glass is strong and resistant to breakage, and the aluminum frame is corrosion-resistant and will not rust. The shower enclosure has a sleek, modern design that will complement any bathroom décor.

Some of the key features of the Vigo VG6048STCL6074 shower enclosure include:

  • Reversible door: The door can be installed on the right or left side of the enclosure, making it ideal for a variety of bathroom layouts.
  • Magnetic door seal: The magnetic door seal keeps the door closed securely, preventing water from leaking out.

Vigo VG6048STCL6074 shower enclosure is a high-quality, durable product that is easy to install and maintain. The 3/8" thick tempered glass is strong and resistant to breakage, and the aluminum frame is corrosion-resistant and will not rust. The shower enclosure has a sleek, modern design that will complement any bathroom décor.

Some of the key features of the Vigo VG6048STCL6074 shower enclosure include:

  • Reversible door: The door can be installed on the right or left side of the enclosure, making it ideal for a variety of bathroom layouts.
  • Magnetic door seal: The magnetic door seal keeps the door closed securely, preventing water from leaking out.
This Installation Guide uses the following symbols to indicate important information.
Always observe the instructions indicated by these symbols.
VIGO INDUSTRIES INSTALLATION GUIDE FOR
SHOWER ENCLOSURE (MODEL VG06048)
Instructions that, if ignored, could result in death or serious personal injury caused by
incorrect handling or installation of the product. These instructions must be observed for
safe installation.
Maintenance and other important non-personal injury and non-material damage instructions
or statements that should be observed.
It is highly advised to dry fit the unit prior to any installation.
IMPORTANT
SAFETY PRECAUTIONS!
WARNING!
The instructions for the following unit is based off of the Vigo brand shower base. The
instructions can not be provided for any other installation other than that of the Vigo brand.
The warranty will be voided if the following was not performed properly.
CAUTION!
1
*VIGO reserves the right to modify/update all hardware and glass components based on
bettering the product for the end user's experience. If you have any questions contact VIGO
Tech Support at 1-866-591-7792.
Product lines may change, contact your Vigo representative at 1-866-591-7792 or visit
our website at www.vigoindustries.com for the most up to date product line information.
2
MODEL VG06048 NYOS
PLEASE READ INSTRUCTIONS BEFORE PROCEEDING
INSTALLATION INSTRUCTIONS FOR SHOWER ENCLOSURE
Parts List
1. Hex screw 1 5/8" (3pc)
2. Plastic anchors white (3pc)
3. Glass support (2pc)
4. Side seal strip (1pc + 1pc spare)
5. Door side seal strip (1pc + 1pc spare)
6. Structural arm (1pc)
7. Hinges (2pc)
8. Door magnetic seal strip (2pc)
9. Wall connector (1pc)
10. Side glass panel (1pc)
11. Door bottom seal strip (1pc + 1pc spare)
12. Plastic anchors green (6pc)
13. Door threshold (1pc)
14. Door (1pc)
15. Handle assembly (1pc)
16. Phillips screw 3/4" (2pc)
17. Support assembly (1pc)
18. Right threshold clip (1pc)
19. Left threshold clip (1pc)
20. Vertical rail (1pc)
21. 8mm screw cover (4pc)
22. 4mm screw cover (12pc)
23. Phillips screw 1 1/8" (4pc)
NOTE: INSTALLATION MUST BE DONE BY A QUALIFIED, LICENSED PROFESSIONAL.
GLASS THICKNESS 3/8"
2
2
3
1
4
2
3
1
9
6
17
5
1
7
16
19
12
8
20
2
23
16
18
12
13
11
15
14
10
3
MODEL VG06048
A
C
B
A, B & C DIMENSIONS WERE MEASURED AFTER SHOWER ENCLOSURE WAS COMPLETELY INSTALLED
DIMENSION "B"
(FIXED PANEL)
DIMENSION "A"
(DOOR)
25 5/8" x 70 7/8"
32 5/8" x 72"
HEIGHT
72"
VG6048XX6072
DIMENSION "C"
(WIDTH)
60"
MODEL
96002
96004
98037
98101
96001
98039
98038
96016
1. HEX SCREW 1 5/8" 2. PLASTIC ANCHOR
WHITE
3. GLASS SUPPORT 4. SIDE SEAL STRIP 5. DOOR SIDE SEAL
STRIP
6. STRUCTURAL ARM 7. HINGE 8. DOOR MAGNETIC
SEAL STRIP
9. WALL CONNECTOR 10. SIDE GLASS PANEL
11. DOOR BOTTOM SEAL
STRIP
12. PLASTIC ANCHOR
GREEN
13. DOOR THRESHOLD 14. DOOR 15. HANDLE ASSEMBLY
16. PHILLIPS SCREW 3/4" 18. RIGHT THRESHOLD
CLIP
19. LEFT THRESHOLD
CLIP
98095
98100 98098
97041CL
98104
97042CL
98099
98033
98102
17. SUPPORT ASSEMBLY
98097
98096
98111
21. 8mm SCREW COVER 22. 4mm SCREW COVER
98040
20. VERTICAL RAIL
98103
DOOR OPENING
WIDTH
24 1/4" - 25 1/4"
23. PHILLIPS SCREW
1 1/8"
98035
4
WARNING
WE STRONGLY RECOMMEND THAT A LICENSED PROFESSIONAL INSTALL THIS SHOWER
ENCLOSURE AND INCLUDE THE ASSISTANCE OF A SECOND PERSON TO INSTALL THE DOOR UNIT.
!
INSTALLATION OF THE SHOWER DOORS BY AN INEXPERIENCED PERSON MAY RESULT IN GLASS
BREAKAGE AND, CONSEQUENTLY, CAUSE PERSONAL INJURY OR DEATH.
- Handle fragile items with care to prevent personal injury or material damage.
- The glass panels are tempered and cannot be cut. Never attempt to do so.
- Always rest glass on a level surface
BEFORE STARTING
Compare items on your invoice with what you have received. Carefully review the Packing List on page 2. If
any items are missing contact Vigo Industries at 1-866-591-7792. Please check our website at
www.vigoindustries.com for additional information or instructional videos.
REQUIRED TOOLS
Square and/or Phillips #1 and #2 screwdriver
Flat head screwdriver
Electric drill plus 1/32", 3/32", 1/8" and 1/4" drill bit (depending on wall)
Level
Measuring tape
Pencil (non-permanent)
Clear silicone caulking
Utility knife
Shims (not provided)
IMPORTANT:
THE CLEAR GLASS MODEL HAS A REVERSIBLE DOOR AND CAN BE INSTALLED TO THE RIGHT OR LEFT SIDE.
(SEE CONFIGURATION DIAGRAM BELOW)
IMPORTANT
Fiberglass, acrylic or sheetrock construction might not be sufficiently strong enough to support the
shower door enclosure. You should use the wood framing studs from behind the face edge of the stall to
provide a secure mounting to the door. Apply a bead of silicone between the walls and base of the stall.
For optimum performance, you should install the shower door perfectly level on a level surface. Failure to
do so will lead to water leakage and potential property damage.
When installing use heavy duty gloves.
LEFT DOOR
INSTALLATION
RIGHT DOOR
INSTALLATION
DOOR
DOOR PANELSIDE GLASS
PANEL
DOOR PANEL SIDE GLASS
PANEL
10 101414
FIG. 1A (GLASS CONFIGURATION DIAGRAM)
MODEL VG06048
DOOR
5
FIG.1
PREPARATION STEPS TO FOLLOW BEFORE INSTALLATION
CAUTION
!
GASKETS NEED TO BE IN BETWEEN ALL GLASS AND METAL CONTACT. FAILURE TO
DO SO CAN LEAD TO BREAKAGE AND POTENTIAL BODILY HARM.
LEFT DOOR INSTALLATION
RIGHT DOOR INSTALLATION
MODEL VG06048
IMPORTANT
Verify that the overall size of the shower door opening is appropriate for the shower enclosure.
Due to individual site variations, exact guidelines for every situation cannot be supplied. The
recommended framing and dimensional requirements are shown for a typical application and
may vary depending on the site requirements.
To prevent damage to the finish, you should protect the shower cabin bottom with a cardboard
protector before beginning the installation.
Properly apply silicone to the wall and base joints.
Make sure to read corresponding base instructions carefully prior to install on the Vigo Brand
Shower Door System. Failure to do so can cause water leakage and bodily harm.
Ensure that there is sufficient structural support behind the shower wall to hold the weight of the
shower door. If there is insufficient enough support, then reinforce the shower walls with wooden
studs prior to shower door installation. [SEE FIG. 1]
STUDS


6
MODEL VG06048
INSTALLATION STEPS
A1
A2
A. INSTALLING THE SIDE GLASS PANEL
1. Arrange the side glass panel (#10) to the
preferred configuration to determine the
orientation of glass supports (#3). Clean
the side glass panel (#10) edge where the
side seal strip (#4) is to be installed with
rubbing alcohol. Install the side seal strip
(#4) to the wall side of the side glass panel.
2. Screw in the glass supports (#3) with the
hex key to the side glass panel (#10). Be
sure to use washers on both sides of the
panel.
3. Mark holes on the wall for the mounting
screws after leveling panel.
4
10
WALL
SIDE
THIN
GASKETS
10
3
A3
10
3
7
MODEL VG06048
A4
A5
4. Remove the side glass panel and drill holes
into the wall. Insert plastic anchors (#2) into
the holes. Not necessary if installing
into studs. Studs are the preferred
means of installation, anchors can pull
out of the wall causing property damage
and bodily harm. There is a 15mm
adjustment built into the glass supports
for minor modifications.
5. Replace the side glass panel (#10). Screw
into the wall with 1
5/8
" hex screws (#1).
2
2
1
There is a 15mm adjustment
built into the bracket.
15mm
!
10
3
8
MODEL VG06048
B2
THIN
GASKETS
VIEW FROM
INSIDE
SIDE
GLASS
PANEL (10)
HINGE (7)
INSIDE VIEW
SIDE
GLASS
PANEL (10)
CLEAR
PVC SHIM
HINGE (7)
SIDE
GLASS
PANEL (10)
CLEAR
PVC SHIM
INSIDE VIEW
HINGE (7)
B. INSTALLING THE HINGE
Clean the glass surface on the side glass panel
(#10) where the hinges (#7) are to be installed
with rubbing alcohol. Place gaskets on each side
of the side glass panel (#10). Position hinges on
the side glass panel (#10) as shown. Place a
shim(s) as needed between the glass and the
hinge on the bottom. The metal should not rest on
the glass. There is a 1 inch horizontal
adjustment built into the hinges for minor
modifications.
1. Screw the hinges (#7) to the side glass
panel (#10) with the hex key (supplied).
B1
1" adjustment
9
MODEL VG06048
HEX SCREW
SIDE GLASS
PANEL (10)
DOOR (14)
THIN
GASKET
VIEW FROM THE TOP
HINGE (7)
OUTSIDE OF
THE CABIN
INSIDE OF
THE CABIN
PLATE
THIN
GASKETS
THIN
GASKET
SEAL STRIP
(5)
VIEW FROM
INSIDE
C1
DOOR PANEL INSTALLATION REQUIRES TWO
OR MORE PEOPLE TO ASSIST
C. INSTALLING THE DOOR
1. Clean the door panel (#14) edge where the
door side seal strip (#5) is to be installed with
rubbing alcohol. Verify that the soft flange of
the seal strip faces toward the inside of the
shower cabin before seal strip installation.
Install the seal strip according to the diagram.
NOTES:
1. If the seal strip is not flat and is twisted, soak
the strip in hot water and press the seal strip
back into position.
2. Part #5 is reversible and pre-cut on top and
bottom to fit in proper configuration.
Cutting/finishing is needed but only after
fully installing and only at the top of the unit.
2. Place the door on a 5/8" shim (not provided).
Install the top hinge first for safety and ease
of install. Position the door onto the hinges.
Hold securely in place using shims. The seal
(#5) may get stuck between the two panels of
glass. Pull the seal out of the groove using
your fingers and nothing sharp, making sure
not to damage the seal. Tighten allen key
screws. Install the hinges as illustrated. Use
the hex key supplied. Adjust hinge so the
gaps are equal at top and bottom and pull
door panel away from side glass panel (#10)
to allow the door to swing freely without
crimping seal strip (#5).
THIS SIDE MUST
LOOK INSIDE
THE CABIN
14
5
C2
OUTSIDE VIEW
3/8"
[10mm]
MAKE SURE TO
LEAVE A GAP OF
3/8" [10MM] FROM
THE BOTTOM OF
THE GLASS
10
MODEL VG06048
3. Lift door panel to be level with hinge panel.
Use PVC shims provided to hold firmly in
place. NOTE - PVC shims prevent the
door from sagging due to gravity and
the weight of the door. Never install
without shims, this can cause the glass to
break causing property damage and
bodily harm.
4. Make sure the door is level from the end.
If the door is not level, adjust the hinge
positions until the door is level. This being
level is imperative to the installation and will
guarantee a tight seal.
C3
INSIDE VIEW
DOOR
PANEL (14)
CLEAR
PVC SHIM
HINGE (7)
DOOR
PANEL (14)
CLEAR
PVC SHIM
INSIDE VIEW
HINGE (7)
!
C4
THIS SIDE
MUST BE
LEVEL
14
VIEW FROM
INSIDE
11
MODEL VG06048
5. Clean the door (#14) glass surfaces where
the magnetic seal strip (#8) is to be
installed with rubbing alcohol. Place the
magnetic seal strip (#8) to the door panel.
The magnetic side should be facing the
inside and the clear side be facing the
outside. Do not install the handle first,
this is dangerous and may cause the
glass to break. The door magnetic seal
strip (#8) is reversible and will need to be
cut at top for best aesthetic approach.
C5
!
VIEW FROM
INSIDE
14
8
D. INSTALLING THE VERTICAL RAIL
1. Clean the vertical rail (#20) with rubbing
alcohol. Place the magnetic seal strip (#8)
on the vertical rail (#20). The magnetic
side should be facing the outside and the
clear side be facing the inside. The door
magnetic seal strip (#8) is reversible and
will need to be cut at top for best aesthetic
approach.
D1
20
8
12
MODEL VG06048
2. Connect the vertical rail (#20) to the door
panel (#14) by the magnetic seal strips (#8).
3. One person must hold the connection at the
magnetic seal strips (#8) together and place
the door in the closed position. The other
person will mark the location of the vertical
rail (#20) along the wall by tracing the
sides.
D2
8
14
20
D3
8
20
14
TRACE SIDES
13
MODEL VG06048
4. Open the door (#14) and remove the
magnetic seal strip (#8) from the vertical
rail (#20). Position the vertical rail (#20)
along the wall where you marked, making
sure the bottom rests on the floor. Mark
holes on the wall for mounting screws.
5.
Remove the
vertical rail (#20)
. Drill holes
into the respective marks and insert white
plastic anchors (#2) inside them.
Not necessary if installing into studs.
Studs are the preferred means of
installation, anchors can pull out of the
wall causing property damage and
bodily harm.
D4
!
D5
20
14
MODEL VG06048
6. Replace the vertical rail (#20) and
screw into the wall with 3/4" phillips screws
(#16).
D6
7. Replace the magnetic seal strip (#8) back
onto the vertical rail (#20).
20
16
D7
20
8
3/8"
[10mm]
MAKE SURE TO
LEAVE A GAP OF
3/8" [10MM] FROM
THE BOTTOM OF
THE VERTICAL
RAIL
15
E. INSTALLING THE STRUCTURAL ARM
E1
1. Install the support assembly (#17) onto the
side glass panel (#10) approximately half
way away from the wall. Do not tighten.
2. Install the structural arm (#6) to the support
assembly (#17). The wall connector (#9)
should be attached to the other side of the
structural arm (#6). Slide the support
assembly towards the wall until the wall
connector (#9) is flush with the wall. Make
sure it is level. Mark the location of the wall
connector along the wall.
WALL
SIDE PANEL
OUTSIDE OF
THE CABIN
WALL
E2
17
SIDE PANEL
MODEL VG06048
SIDE PANEL
WALL
17
9
6
LEVEL
16
3. Remove the support assembly. Position the
wall connector (#9) back to where you
marked the wall and mark a hole on the wall
for the wall connector plate.
4. Remove the wall connector (#9). Drill a hole
into the respective mark and put a plastic
anchor (#2) in it. Not necessary if
installing into studs. Studs are the
preferred means of installation, anchors
can pull out of the wall causing property
damage and bodily harm.
5. Replace the wall connector plate to the
proper position. Screw it into the wall with 1
5/8" screws (#1). There is a 5mm
adjustment built into the wall connector
plate for minor modifications.
E3
E4
E5
MODEL VG06048
SIDE PANEL
WALL
9
!
SIDE PANEL
WALL
2
SIDE
PANEL
WALL
1
There is a 5mm adjustment
built into the plate.
5mm
17
MODEL VG06048
6. Place the wall connector (#9) onto the plate
and slide the structural arm (#6) into the
wall connector. Slide the other side of the
structural arm (#6) into the support
assembly (#17) on the side panel. Tighten
all set screws.
F. INSTALLING THE HANDLE
1. Assemble the handle assembly (#15) to the
door (#14).
E6
F1
SIDE PANEL
WALL
17
9
6
DOOR
PANEL
INSIDE HANDLE
SCREW
CLEAR
WASHER
CLEAR TUBE
OUTSIDE
HANDLE
SET
SCREWS
CLEAR
WASHER
18
MODEL VG06048
G. INSTALLING THE THRESHOLD
1. Position the right threshold clip (#18) at the
bottom of the vertical rail (#20). Mark the
location for the mounting hole.
2. Remove the right threshold clip (#18). Drill a
hole into the respective mark and put a
plastic anchor (#12) in it. Not necessary
if installing into studs. Studs are the
preferred means of installation, anchors
can pull out of the wall causing property
damage and bodily harm.
3.
Replace the right threshold clip (#18) to the
proper position. Screw it into the floor with
3/4" screws (#16).
G1
18
20
8
G2
!
20
8
12
G3
18
20
8
16
12
19
MODEL VG06048
4. Position the left threshold clip (#19) at the
bottom of the side panel (#10). Mark the
location for the mounting hole.
5. Remove the left threshold clip (#19). Drill a
hole into the respective mark and put a
plastic anchor (#12) in it. Not necessary
if installing into studs. Studs are the
preferred means of installation, anchors
can pull out of the wall causing property
damage and bodily harm.
6.
Slide the door threshold (#13) into the right
threshold (#18). Replace the left threshold
(#19) to the proper position. Screw it into
the floor with 3/4" screws (#16).
G4
10
19
G5
10
!
12
G6
18
16
13
19
12
8
20
H. INSTALLING BOTTOM DOOR SEAL STRIP
1. Clean the door glass panel (#14) edge where
the door bottom side seal strip (#11) is to be
installed with rubbing alcohol. Verify that the
soft flange of the seal strip faces toward the
inside of the shower cabin before seal strip
installation. Install the seal strip according to
the diagram.
NOTES:
1. If the seal strip is not flat, use a hair dryer to
apply minimal heat and press the seal strip back
into position.
2. Adjust the magnetic seal strip (#8) and the door
side seal strip (#5) to the correct height over the
door bottom seal strip (#11) and cut to the needed
height at the top of the panel.
I. INSTALLING COVERS
1. Install screw covers (#21 & #22) to the
unit. Please pay attention that there are
two types of covers. The 8mm screw
covers are for the threshold clips (#18 &
#19) and handle (#15). The 4mm screw
covers are for everything else. Install the
glass support covers to the glass
supports (#3).
20
MODEL VG06048
14
OUTSIDE OF
THE CABIN
8
11
H1
5
I1
8mm
4mm
18
19
7
17
9
3
15
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23

Vigo VG6048STCL6074 Installation guide

Type
Installation guide

Vigo VG6048STCL6074 shower enclosure is a high-quality, durable product that is easy to install and maintain. The 3/8" thick tempered glass is strong and resistant to breakage, and the aluminum frame is corrosion-resistant and will not rust. The shower enclosure has a sleek, modern design that will complement any bathroom décor.

Some of the key features of the Vigo VG6048STCL6074 shower enclosure include:

  • Reversible door: The door can be installed on the right or left side of the enclosure, making it ideal for a variety of bathroom layouts.
  • Magnetic door seal: The magnetic door seal keeps the door closed securely, preventing water from leaking out.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI