George Kovacs P5014-084 Installation guide

Type
Installation guide
INSTALLATION INSTRUCTIONS
For Model # P5013-084/P5014-084/P5015-084 (New 05/12/2006)
WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER.
Fig. 2
Fig. 1
Fig. 3
MOUNTING THE FIXTURE (Fig. 1)
1. Shut off power at the circuit breaker and remove old
fixture from wall, including the crossbar.
2. Carefully unpack your new fixture and lay out all the
parts on a clear area. Take care not to lose any small
parts necessary for installation.
3. Secure Circular Strap (A) using Screw (B) to the
Outlet Box. The side of the Circular Strap marked
“GND” must face out.
CONNECTING THE WIRES (Fig. 2)
4. Connect the electrical wires as shown in Fig. 2,
making sure that all wire connectors are secured. If
your outlet has a ground wire (green or bare copper),
connect the fixture’s Ground Wire to it. Otherwise,
connect the fixture’s Ground Wire directly to the
Circular Strap by using the Green Screw provided.
FINISHING THE INSTALLATION (Fig. 1)
5. Place Fixture Body (D) over the Circular Strap (A)
then secures them tightly with two Screw Stud (C).
6. Install halogen bulb into socket in accordance with
the fixture’s specifications. (DO NOT EXCEED THE
MAXIMUM WATTAGE RATING!)
INSTALLATION OF BULB SHIELD(Fig.3)
7. Line up the arrow from the bulb shield (F) to the allen
set screw (G) from the glass holder.Use the allen
wrench provided to back out the allen set screw as
needed to fit the bulb shield all the way until the allen set
screw can properly engage the recessed hole from the
bulb shield Securely tighten the allen set screw with
allen wrench.
To secure bulb shield turn set screw in clockwise
motion into recessed hole.
8.Place glass shade (H) onto the socket, then secure it
by three screws (E).
9.For glass shade angle adjustment, loosen the screw
(I) by using the provided Allen wrench. After
adjustment, tighten up the screw (I) again.
Your installation is now complete. Return power to
the outlet box and test the fixture.
FIXTURE
WIRES
Black or
Smooth
H
O
USE
WIRES
Black
(Hot)
FIXTURE
WIRES
White or
Ribbed
H
O
USE
WIRES
White
(Neutral)
FIXTURE
WIRES
Bare
Copper
(Ground)
H
O
USE
WIRES
Green
(Ground)
MIN 90SUPPLY CONDUCTORS
C
A
B
G
F
E
H
D
I
  • Page 1 1

George Kovacs P5014-084 Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI