  • Hello! I am an AI chatbot trained to assist you with the Dell PowerEdge 6850 Owner's manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
  • Which version of QLogic SANSurfer SANblade Manager supports the Dell 2362M Integrated Fibre Channel Module?
    Where can I find an updated StorPort driver for Windows Server 2003?
    How can I avoid port synchronization failures when using Brocade SilkWorm 4100?
    How is the Dell 2362M Integrated Fibre Channel Module displayed during system boot?
    Where can I find configuration information, drivers, and a list of EMC-approved software for the Dell 2362M Integrated Fibre Channel Module?
www.dell.com | support.dell.com
Information Update
For instructions on installing your Dell
2362M Integrated Fibre Channel Module, refer to the
PowerEdge
6850
Installation and Troubleshooting Guide
. Configuration information, drivers, and
a list of EMC-approved software are available on
support.dell.com
.
Using the StorPort Driver with the Microsoft
®
Windows
®
Server 2003 Operating System
If you are using the StorPort driver with the Microsoft
Windows Server 2003 operating system and
do not have Service Pack 1 or later installed, make sure you are using the latest
storport.sys
driver.
Updated StorPort drivers are available from
www.microsoft.com
. For the latest required hotfix, see
http://www.qlogic.com/go/emc_approved
.
QLogic SANSurfer SANblade Manager
QLogic SANSurfer SANblade Manager version 2.0.30 Build 17 or later supports the Dell 2362M
Integrated Fibre Channel Module card for the PowerEdge 6850. If you are using an earlier version,
see
support.dell.com
or
www.qlogic.com
to update your SANSurfer application.
Brocade SilkWorm 4100 Port Synchronization
When using Fabric Operating System version 4.4.0b or earlier, port synchronization may fail. To
avoid this problem, set the topology to loop-first and point-to-point. This corresponds to the
default NVRAM settings. An update that resolves this issue will be available at
www.brocade.com
.
Version Display at System Boot
During system boot, the Dell 2362M Integrated Fibre Channel Module is displayed as
QLA2322
.
___________________
Information in this document is subject to change without notice.
© 2005 Dell Inc. All rights reserved. Printed in the U.S.A.
Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell, PowerEdge, and the DELL logo are trademarks of Dell Inc.; EMC is the registered trademark
of EMC Corporation; Microsoft and Windows are registered trademarks of Microsoft Corporation.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names
or their products. Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
March 2005
R9283am0.fm Page 1 Wednesday, March 2, 2005 3:20 PM
/