Qlogic QLA200 User manual

Type
User manual

This manual is also suitable for

User’s Guide
QLA
200 Family
Covers the following operating systems:
Windows 2000
Windows Server 2003
Red Hat Linux
SuSE Linux
NetWare
FIBRE CHANNEL HBA INSTALLATION P
User’s Guide
[]
Technical Support
Customers should contact their authorized maintenance provider for technical support of
their QLogic products. QLogic-direct customers may contact QLogic Technical Support;
others will be redirected to their authorized maintenance provider.
Visit the QLogic support Web site listed in Contact Information section for the latest firmware
and software updates.
Availability
QLogic Technical Support is available from 7:00 AM to 7:00 PM Central Standard Time,
Monday through Friday, excluding QLogic-observed holidays.
Training
QLogic offers certification training for the technical professional for both the SANblade™
HBAs and the SANbox switches. From the training link at www.qlogic.com
, you may choose
Electronic-Based Training or schedule an intensive "hands-on" Certification course.
Technical Certification courses include installation, maintenance and troubleshooting
QLogic SAN products. Upon demonstrating knowledge using live equipment, QLogic awards
a certificate identifying the student as a Certified Professional. The training professionals
at QLogic may be reached by email at tech.trainin[email protected].
Contact Information
Use the following table to write down the serial numbers of your QLA200 HBAs. This
information is useful for QLogic technical support and for your HBA warranty.
Address: QLogic Corporation
6321 Bury Drive
Eden Prairie, Minnesota 55346
USA
Telephone: +1 952-932-4040
Fax: +1 952-932-4018
Email:
Technical Support
Technical Training
HBA support web site: support.qlogic.com
HBA Serial Number HBA Serial Number
1 5
2 6
3 7
4 8
FL0054601-00 B Page i
QLA200 User’s Guide
2-Gbps Fibre Channel to PCI-X Host Bus Adapter
Page ii FL0054601-00 B
QLA200 User’s Guide
2-Gb Fibre Channel to PCI-X Host Bus Adapter
Information furnished in this manual is believed to be accurate and reliable. However, QLogic Corporation
assumes no responsibility for its use; nor for any infringements of patents or other rights of third parties which
may result from its use. QLogic Corporation reserves the right to change product specifications at any time
without notice. Applications described in this document for any of these products are for illustrative purposes
only. QLogic Corporation makes no representation nor warranty that such applications are suitable for the
specified use without further testing or modification. QLogic Corporation assumes no responsibility for any
errors that may appear in this document.
No part of this document may be copied nor reproduced by any means, nor translated nor transmitted to
any magnetic medium without the express written consent of QLogic Corporation.
Linux is a registered trademark of Linus Torvalds.
Microsoft, Windows NT, Windows Server, Windows 2000, and Windows Server 2003, are trademarks or registered
trademarks of Microsoft Corporation.
QLA, QLogic, and the QLogic logo are registered trademarks of QLogic Corporation.
Red Hat and all Red Hat-based trademarks are trademarks or registered trademarks of Red Hat, Inc.
Solaris is a registered trademark of Sun Microsystems, Inc.
SuSE is a registered trademark of SuSE Linux AG.
WinZip is a registered trademark of WinZip Computing, Inc.
All other brand and product names are trademarks or registered trademarks of their respective owners.
Document Revision History
Rev A release, 1/20/04
Rev B update, 4/9/04
Changes Document Sections Affected
Re-format/re-design guide All
Updated QLA200 information. 1
Updated HBA installation instructions 2
Updated instructions for driver installation in Windows operating systems 3
Updated instructions for driver installation in Red Hat/SuSE Linux operating
systems
4
Added instructions for driver installation in NetWare operating systems 5
Revised hardware troubleshooting information. 6.1.1
Updated Fast!UTIL information. 7
© 2003–2004 QLogic Corporation. All rights reserved worldwide.
First Printed: November 2003
Printed in U.S.A.
QLogic Corporation, 26650 Aliso Viejo Parkway, Aliso Viejo, CA 92656, (800) 662-4471 or (949) 389-6000
FL0054601-00 B Page iii
Table of Contents
Section 1 Introducing the QLA200
1.1 QLA200 HBA Highlights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1
1.2 What’s in the Box? . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1.3 QLA200 HBA Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
1.4 System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
1.5 Installing the QLA200 HBA and Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4
Section 2 HBA Installation
2.1 Installing the QLA200 HBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Section 3 SANsurfer HBA Install Wizard (Windows 2000/Server 2003)
3.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.2 Installing the Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3.3 Updating the Driver. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-7
3.4 Removing the Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
3.5 Performing Diagnostics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
Section 4 Red Hat/SuSE Linux Driver Installation
4.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
4.2 Installing and Uninstalling the Driver with the Source RPM Package. . . . 4-1
4.2.1 Installing the Source RPM Package . . . . . . . . . . . . . . . . . . . . . . . . . . 4-2
4.2.2 Installing Only the Driver Source from the Source RPM Package . . . . 4-2
4.2.3 Uninstalling the Source RPM Package . . . . . . . . . . . . . . . . . . . . . . . . 4-2
4.3 System Driver Parameter max_scsi_luns. . . . . . . . . . . . . . . . . . . . . . . . . 4-2
4.3.1 Multiple LUN Support Through the Kernel . . . . . . . . . . . . . . . . . . . . . . 4-3
4.3.2 Multiple LUN Support when the SCSI Mid-Layer is Compiled
in the Kernel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-3
4.3.3 Multiple LUN Support when the SCSI Mid-Layer is Compiled
as a Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
4.4 Proc Filesystem Support. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-4
Section 5 NetWare Driver Installation
5.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
5.2 Finding the Driver Files. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
QLA200 User’s Guide
2-Gbps Fibre Channel to PCI-X Host Bus Adapter
Page iv FL0054601-00 B
5.3 Installing the Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
5.3.1 Installing the Driver During Installation of the NetWare Operating
System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-2
5.3.2 Installing the Driver on an Existing NetWare Server . . . . . . . . . . . . . . 5-3
5.3.3 Updating the Existing Driver on a NetWare Server . . . . . . . . . . . . . . . 5-3
5.4 Removing the Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-4
5.4.1 Removing the QLA200 HBA and the NetWare Driver . . . . . . . . . . . . . 5-5
5.4.2 Removing the NetWare Driver . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-5
5.5 Driver Parameters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6
5.5.1 System Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6
5.5.2 NVRAM Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-10
Section 6 Troubleshooting
6.1 Problems After Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
6.1.1 Hardware Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-1
6.1.2 System Configuration Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
6.1.3 Fibre Channel Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-2
Section 7 Software Applications and Utilities
7.1 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-1
7.2 Configuration Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
7.2.1 Adapter Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
7.2.2 Selectable Boot Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
7.2.3 Restore Default Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3
7.3 Scan Fibre Channel Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-3
7.4 Fibre Disk Utility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4
7.5 Loopback Data Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4
7.6 Select Host Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-4
Appendix A Compliance, Specifications, and Agency Certification
A.1 Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
A.2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
A.3 Transceiver Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2
A.4 Agency Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3
A.4.1 EMI and EMC Requirements (Preliminary) . . . . . . . . . . . . . . . . . . . . . A-3
A.4.2 Product Safety Requirements (Preliminary) . . . . . . . . . . . . . . . . . . . . . A-3
FL0054601-00 B Page v
QLA200 User’s Guide
2-Gbps Fibre Channel to PCI-X Host Bus Adapter
Figures
Figure Page
1-1 QLA200 HBA Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1-2 QLA200 HBA Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3
2-1 Low-Profile Bracket Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-2
2-2 QLA200 HBA Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
2-3 Connecting the Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
3-1 Found New Hardware Wizard Dialog Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-1
3-2 SANsurfer Fibre Channel HBA Software Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
3-3 SANsurfer HBA Software Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
3-4 SANblade Fibre Channel HBA Management Software and Drivers Screen . . . . . . . 3-3
3-5 File Download Dialog Box (Sample) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
3-6 Initial Driver Installation Dialog Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
3-7 Select Driver Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
3-8 Driver Server Proxy Settings Dialog Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
3-9 Driver Update Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
3-10 Install Status (Successful) Dialog Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
3-11 Install Status (Unsuccessful) Dialog Box. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6
3-12 Driver Install Completed Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-6
3-13 Driver Update Completed Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-8
3-14 Select HBAs to Test Dialog Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10
3-15 Diagnostic Test Results. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-10
3-16 Diagnostic Test Results, Detailed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-11
Tables
Table Page
3-1 Driver Versions that Do Not Require a Loopback Connector . . . . . . . . . . . . . . . . . . 3-9
5-1 QL2300.HAM Driver Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6
5-2 NVRAM Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-10
7-1 Adapter Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-2
A-1 QLA200 Board Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1
A-2 QLA200 Board Operating Environment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2
QLA200 User’s Guide
2-Gbps Fibre Channel to PCI-X Host Bus Adapter
Page vi FL0054601-00 B
Notes
FL0054601-00 B 1-1
Section 1
Introducing the QLA200
1.1
QLA200 HBA Highlights
The following QLogic
host bus adapter (HBA) is supported in this document:
QLA
200 (single channel, full-height bracket, optical media)
The QLA200 is 32-bit, 133-MHz PCI-X 1.0 to Fibre Channel optical media.
The QLA200 HBA is a robust, dependable addition to your storage area network
(SAN). The features and performance are optimized for small and medium
enterprise (SME) markets. With auto-install software, plug-and-play features, and
an enhanced level of technical support, the QLA200 HBA makes expanding your
SAN easy and affordable.
The QLA200 HBA has the following features:
2-Gbps Fibre Channel
133 MHz, 32-bit PCI-X support
Integrated single-chip solution
Enhanced reliability
Support for bus master DMA
Fast!UTIL BIOS utility to enable the BIOS, set the spinup delay, and enable
extended error logging on the QLA200 HBA and attached drives
Supports Fibre Channel protocol-SCSI (FCP-SCSI)
Supports point-to-point fabric connection (F-PORT FABRIC LOGIN)
1 – Introducing the QLA200
What’s in the Box?
1-2 FL0054601-00 B
1.2
What’s in the Box?
Make sure you have everything you need to install the QLA200 HBA (see figure 1-1).
Figure 1-1. QLA200 HBA Kit
QUICK START GUIDE AND
USER’S GUIDE
SANblade™ QLA200 HBA
SYSTEM SERVICE AND
WARRANTY BROCHURE
LOW PROFILE BRACKET
(NOT AVAILABLE IN ALL MODELS)
SANsurfer Fibre Channel HBA
Software CD
Not all of these items are included in
a bulk box.
1 – Introducing the QLA200
QLA200 HBA Components
FL0054601-00 B 1-3
1.3
QLA200 HBA Components
The QLA200 HBA contains parts that can be damaged by
electrostatic discharge (ESD). Before handling the QLA200 HBA,
use standard methods to discharge static electricity. Keep the
QLA200 HBA in the antistatic bag until you are ready to install it.
Place the board on the bag when you examine or configure it. Retain
the bag for future use.
Figure 1-2 identifies the QLA200 HBA components referenced throughout this
section.
Each QLA200 HBA has a unique serial number; its location on the HBA is noted in
figure 1-2. Take a minute to write down the serial number of the QLA200 HBA on
the inside cover of this document. The serial number is required for QLogic technical
support and for your HBA warranty.
Figure 1-2. QLA200 HBA Layout
CAUTION!
Green
LED
Yellow
LED
Activity
Power off
Power
Online
Link established
Flashing
twice per
second
Loss of
synchronization
Green and Yellow LEDs
flashing alternately twice per
second
Firmware error
SERIAL
NUMBER
LEDs
TRANSCEIVER
1 – Introducing the QLA200
System Requirements
1-4 FL0054601-00 B
1.4
System Requirements
Your system must have the following functionality to support the QLA200 HBA:
One of the following:
PCI 32-bit data and 33/66 MHz clock frequency
PCI-X and 66/100/133 MHz clock frequency
3.3-volt signaling (5-volt tolerant)
The correct media (short wave 50µm fiber or 62.5µm fiber) and connectors
(LC duplex)
1.5
Installing the QLA200 HBA and Driver
Installing your QLA200 HBA is quick and easy:
First, install the QLA200 HBA according to the directions in section 2.
Second, install the software driver according to the directions in the section that
corresponds to your computer’s operating system:
Operating System Section
Windows
2000/Windows Server 2003
3
Red Hat/SuSE
Linux
4
Novell NetWare
5
FL0054601-00 B 2-1
Section 2
HBA Installation
2.1
Installing the QLA200 HBA
Perform the following steps to install the QLA200 HBA in your PC:
Step 1. Prepare the system for the QLA200 HBA.
Power down the peripherals, then the computer.
Remove the computer cover and save the screws.
Check the motherboard and make any configuration changes
necessary to accommodate the QLA200 HBA.
The QLA200 HBA is self-configuring; however, some motherboards
require manual configuration. For example, some systems have a PCI
Device Configuration menu in the motherboard setup BIOS where
you must enable HBAs, bus master slots, and IRQ levels. If the
motherboard supports triggering, use level triggering for the QLA200
HBA. See the documentation supplied with your computer, or contact
your computer dealer to determine if your motherboard requires
configuration.
Choose any PCI bus slot that supports bus mastering.
Most motherboards automatically assign an IRQ level and interrupt line;
if your motherboard does not, you must assign the IRQ level and use
interrupt line A for this slot.
Remove the slot cover for the slot in which you will install the QLA200
HBA.
2 – HBA Installation
Installing the QLA200 HBA
2-2 FL0054601-00 B
Step 2. Install the low-profile bracket (optional).
Remove the two screws that attach the current bracket to the HBA.
Retain the screws to re-attach the new bracket (see figure 2-1).
Figure 2-1. Low-Profile Bracket Installation
Remove the current bracket by sliding it off the transceiver housings.
Set the bracket aside.
Position the new bracket over the transceiver housings. Gently press
the bracket into position. Make sure the mounting tabs with the threaded
holes are positioned on the far side (the side opposite the transceiver)
of the QLA200 HBA.
Align the screw holes of the QLA200 HBA and the bracket, then insert
and tighten the screws. Correct torque is 3.6-in/lbs.
BRACKET
SCREW
SCREW
2 – HBA Installation
Installing the QLA200 HBA
FL0054601-00 B 2-3
Step 3. Install the QLA200 HBA (see figure 2-2).
Figure 2-2. QLA200 HBA Installation
Place the QLA200 HBA into the slot. Carefully press the HBA into the
slot until it seats firmly.
Secure the QLA200 HBA to the chassis. Follow the PC manufacturer’s
instructions.
Connect the Fibre Channel connectors to the QLA200 HBA; follow the
instructions provided by your storage vendor (RAID box) (see
figure 2-3).
Figure 2-3. Connecting the Cable
Carefully reinstall the computer cover. Insert and tighten the computer
cover screws.
HBA RETAINING
BRACKET
LEVER
SLOT COVERS
SYSTEM
CHASSIS
64-BIT PCI BUS
32-BIT PCI BUS
OR
SCREW
QLA200 HBA
Cable Type Max. Length Min. Length
62.5/125 µm
(LC, multimode)
150 meters at 2.125 Gpbs 2 meters
50/125 µm
(LC, multimode)
300 meters at 2.125 Gpbs 2 meters
2 – HBA Installation
Installing the QLA200 HBA
2-4 FL0054601-00 B
Step 4. Power up all external FC devices, then power up the PC and observe the
monitor.
By default, the BIOS is disabled. Therefore, the devices attached to the
QLA200 HBA are not displayed when the PC is powered up. For example:
QLogic Corporation
QLA200 PCI Fibre Channel ROM BIOS Version x.xx
Copyright (C) QLogic Corporation 2004 All rights reserved.
www.qlogic.com
Press <CNTRL-Q> for Fast!UTIL
BIOS for Adapter 0 is disabled
ROM BIOS not installed
Enable the BIOS only if the boot device is attached to the
QLA200 HBA. This allows the system to boot faster.
For more information about enabling the QLA200 HBA
BIOS, see section 7.
Congratulations! You have successfully installed your QLogic HBA! You are now
ready to install the HBA driver.
See the appropriate section for detailed instructions on how to install the software
drivers.
If the information displayed is not correct and you have checked the QLA200 HBAs
configuration, see section 6 for troubleshooting information.
See section 7 for detailed instructions on how to customize the QLA200 HBA and
its attached devices using the Fast!UTIL BIOS utility.
Operating System Section
Windows
2000/Windows Server 2003
3
Red Hat/SuSE
Linux
4
Novell NetWare
5
NOTE
FL0054601-00 B 3-1
Section 3
SANsurfer HBA Install Wizard (Windows 2000/Server 2003)
3.1
Introduction
The SANsurfer HBA Install Wizard does the following:
Installs the QLA200 HBA driver for Windows 2000/Server 2003 operating
systems (see section 3.2)
Updates the QLA200 HBA driver for Windows 2000/Server 2003 operating
systems (see section 3.3). (To remove the driver, see section 3.4.)
Performs diagnostics on the QLA200 HBA and its attached devices (see
section 3.5)
The SANsurfer HBA Install Wizard is on the SANsurfer Fibre Channel HBA Software
CD-ROM (CD), and can be run from the CD at any time. To run the wizard from the
server (optional), see the instructions in section 3.2.
3.2
Installing the Driver
If you have installed the QLA200 HBA in a Windows 2000/Server 2003 operating
system, follow these instructions to launch the SANsurfer HBA Install Wizard, which
installs the HBA driver automatically.
When the system is powered on, the Microsoft Found New
Hardware Wizard dialog box (plug-and-play installation process)
may display (see figure 3-1). Click Cancel. You may have multiple
dialog boxes if more than one QLA200 HBA is installed in the
system. Click Cancel in each dialog box.
Figure 3-1. Found New Hardware Wizard Dialog Box
NOTE
3 – SANsurfer HBA Install Wizard (Windows 2000/Server 2003)
Installing the Driver
3-2 FL0054601-00 B
Step 1. Insert the SANsurfer Fibre Channel HBA Software CD in an appropriate
drive. The SANsurfer Fibre Channel HBA Software screen displays (see
figure 3-2).
Figure 3-2. SANsurfer Fibre Channel HBA Software Screen
If the SANsurfer Fibre Channel HBA Software screen does not display,
do the following:
Select the drive where the SANsurfer Fibre Channel HBA Software CD
is located.
Locate and double-click the Start_Here.htm file.
Step 2. Click Drivers and Application. The SANsurfer HBA Software screen
displays (see figure 3-3).
Figure 3-3. SANsurfer HBA Software Screen
3 – SANsurfer HBA Install Wizard (Windows 2000/Server 2003)
Installing the Driver
FL0054601-00 B 3-3
Step 3. In the table titled 2Gb FC - QLA200 Series, click the appropriate operating
system: Windows 2000 or Windows Server 2003. The SANblade Fibre
Channel HBA Management Software and Drivers screen displays (see
figure 3-4).
Figure 3-4. SANblade Fibre Channel HBA Management Software and Drivers Screen
Step 4. In the table titled 2Gb FC - QLA200 Series, click Click Here to Install.
The File Download dialog box displays (see figure 3-5).
Figure 3-5. File Download Dialog Box (Sample)
Step 5. You can run the SANsurfer HBA Install Wizard from the CD. Optionally,
you can download the wizard to the server and run it from there. Do one
of the following:
Click Open or Run to run the SANsurfer HBA Install Wizard from the CD.
Click Save to download the application to the computer’s hard disk. The
Save As dialog box displays. Specify a location on the hard disk, then
click Save. From that location, double-click the installation file
qlflzip.exe.
The SANsurfer HBA Install Wizard starts automatically. If the wizard does
not start and you are running the wizard from the CD, do the following:
Select the drive where the SANsurfer Fibre Channel HBA Software CD
is located.
In the \data\files\windows directory, double-click the installation file
qlflinst.exe.
3 – SANsurfer HBA Install Wizard (Windows 2000/Server 2003)
Installing the Driver
3-4 FL0054601-00 B
Step 6. The Initial Driver Installation dialog box displays (see figure 3-6). Click
Install Driver to continue with the driver installation.
Figure 3-6. Initial Driver Installation Dialog Box
Step 7. The Select Driver dialog box displays (see figure 3-7).
Figure 3-7. Select Driver Dialog Box
Select the driver location by selecting one the following radio buttons:
Default Driver (provided with wizard), From the Qlogic website, or
Browse.
If your system has internet access, QLogic recommends
selecting the From the QLogic website radio button.
Select Browse if you previously downloaded the driver to
your hard disk.
NOTE
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54

Qlogic QLA200 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI