Specifications
GS/MON/AVFL42_0521
Artisan AVFL42
APPLIANCE LOCATIONS
FRAMING DIMENSIONS
DETERMINE UNIT SIZE
See homowner’s manual for information on determining the proper
size unit for the space required. 47-7/8"
1/2"
1/2"
47-7/8"
71-1/4"
13-1/8”
39-3/4”
Framing
42"
46-5/8"
AVFL42 AVFL48 AVFL60
A 42 in 48 in 60 in
B 46-5/8 in 52-5/8 in 64-5/8 in
C 47-7/8 in 55-3/8 in 63-7/8 in
D 71-1/4 in 78-1/4 in 90-3/8 in
Back Wall Clearance — The appliance may be placed against a combustible back wall.
Floor Clearance — The fireplace may be installed directly on a combustible floor or a raised platform of an appropriate height. Do not place fireplace on
carpeting, vinyl, tile or other soft floor coverings. It may, however, be placed on flat wood, plywood, particle board or other hard surfaces. Be sure fireplace
rests on a solid continuous floor or platform with appropriate framing for support and so that no cold air can enter from under the firebox.
Ceiling
Wall
Stud
Non-Combustible
Board
36"
Top of Appliance Opening
22"
8"
20
"
3"
17-1/2
"
19
"
6"
SIDE VIEW
Sidewall
Appliance
Opening
TOP VIEW
12
"
2-1/2
"
1-1/2
"
3-1/2
"
4-1/2
"
3
"
5
"
6
"
45˚
1
"
COMBUSTIBLE MANTEL CLEARANCES
SIDE VIEW
TOP VIEW
Ceiling
Wall
Stud
Non-Combustible
Board
36"
Top of Appliance
Opening
20"
8"
19"
3"
17-1/2"
19"
6"
Appliance
Opening
Sidewall
Note: Reducing clearances further requires non-combustible construction materials-
(eg: steel studs, durock, etc) to a height of 12" above the framing height.
12"
3
"
5
"
6
"
45˚
1
"
1
"
2
"
4
"
6
"
7
"
NON-COMBUSTIBLE MANTEL CLEARANCES
(877) 863-4350 | monessenhearth.com
Product information provided is not complete and is subject to change without
notice. Product installation must adhere strictly to instructions accompanying
product to avoid risk of fire and potential injury.
PRODUCT LISTING CODES
US ANSI Z223.1 / NFPA54
ANSI Z21.11.2:19