Extech Instruments THD5 User manual

Type
User manual

Extech Instruments THD5 is a single-use, waterproof, and portable USB Temperature Datalogger designed for monitoring the transportation of products subject to cold chain requirements. With its user-friendly interface and advanced features, the THD5 offers reliable temperature monitoring solutions.

Key capabilities of the THD5 include:

  • Easy-to-use with intuitive programming and data retrieval process.
  • Waterproof (IP65) construction ensures protection against moisture and dust, making it suitable for various environments.
  • USB 2.0 connectivity allows for quick and convenient data transfer to a PC for analysis and report generation.

Extech Instruments THD5 is a single-use, waterproof, and portable USB Temperature Datalogger designed for monitoring the transportation of products subject to cold chain requirements. With its user-friendly interface and advanced features, the THD5 offers reliable temperature monitoring solutions.

Key capabilities of the THD5 include:

  • Easy-to-use with intuitive programming and data retrieval process.
  • Waterproof (IP65) construction ensures protection against moisture and dust, making it suitable for various environments.
  • USB 2.0 connectivity allows for quick and convenient data transfer to a PC for analysis and report generation.
USER GUIDE
USBTemperatureDatalogger
ModelTHD5
Introduction
Thankyouforselectingthe‘singleuse’ExtechModelTHD5USBTemperatureDatalogger.This
dataloggerisspecificallydesignedformonitoringthetransportationofproductssubjecttocold
chainrequirements.
TheTHD5isaneasytouse,waterproof(IP65),andportableUSBTemperatureDatalogger.The
THD5usesaUSB2.0connectorthatcanbepluggedintoaPCforusercustomizeddatalogger
setup.TheTHD5canthenbeplacedinanareawheretemperatureistobemonitored. Once
placed,theusercanpresstheSTARTbuttontobeginrecording.Whencompleted,theTHD5can
thenbepluggedbackintothePCwhereaPDFreportofloggedtemperaturereadingscanbe
generated(AdobeReader®softwarerequired).
Ten(10)onetimeusedataloggersareprovided;eachcanlog8192temperaturereadings.This
deviceisshippedfullytestedandcalibrated.
2 THD5-en-GB_V1.0 4/15
32
1
4
56 7
DataloggerDescription
1. USB2.0‘Plug&Play’connector.USBdriverisnotrequired.
2. LEDindicator:
Low/High:RedLEDblinkswhenmeasurementexceedsanalarmthreshold
GreenOK:GreenLEDblinksthreetimesevery5secondswhenloggerisinstandbymode.Whenlogging
isstarted,thegreenLEDblinksevery2seconds
RedLowBattery:RedLEDblinksevery2secondswhenpoweristoolowtoprovideaccuratelogging
3. NTCthermistorprovidesaccuratetemperaturemeasurements
4. PreinstalledCR2032battery
5. START/STOPbutton:
Aftertheloggerisprogrammed,pressandholdthe‘START’buttonfor2secondstobeginlogging.To
stop,pressandholdthe‘STOP’buttonfor2seconds.
6. MARKbutton:
Thisbuttonisusedtomanuallyplacea‘bookmark’inthedatalogrecord.Thesetimestampedmarks
appearinthePDFreportthatcanbegeneratedonaPC.
7. IP65zippedplasticbag:
Openthebagandremovetheunitforprogramming.
Afterprogramming,returntheunittotheplasticbagandsealthebagbeforelogging.
3 THD5-en-GB_V1.0 4/15
DataloggerConfigurationScreenDescription
ConnecttheTHD5tothePCviatheUSBporttoopenthisscreen.RefertotheOperationSection
belowfordetailsontheitemsshownonthisScreen:
1. Languageselection
2. Loggersamplingrate
3. Loggerstartdelaytime
4. Temperatureunitselection
5. Passwordmodeselection
6. User’scompanyname
7. Confirmsettings
8. Selectalarmtype
9. Setalarmdelaytime
10. Selecthighandlowalarm
thresholds
11. Alarmrange(forcumulative
alarmtype)
12.
Cancelprogramming
13. OpenusermanualPDF
Operation
NOTES:
1.AdobeReader®softwareisrequired.
2.PleaseprogramtheloggerandgeneratethePDFreportatroomtemperatureonly.
3.Theprogrammingexecutablefilesareidentifiedbythe*.exeformat.
Configuringthedatalogger
Atanytimebeforeloggingisstarted,theloggercanbeprogrammedandreprogrammed.
1. ConnectthedataloggertoaPCviatheUSBport.
2. TheLoggerstatusLEDsblinktwice.
3. ThesoftwarewindowwillappearonthePC.
4. Clickon‘OpenFolder’toviewthe
availablefiles.
5. Openthefile"PDFLoggerConfigurationTool.exe".
6. ThedefaultlanguageisEnglish;selectGerman,French,Italian,Spanish,orPortugueseas
desired.ThegeneratedPDFreportformatwillmatchthelanguageselected.
7. Toreviewtheinstructionmanual,click‘Manual’tolinktotheUserManualPDF
file.
8. TheProgrammableParametersaredefinedbelow:
UserCompanyName
InputacompanynamethatwillbeprintedonthePDFreport(20charactersmax.).
Samplingrate
Selectthedataloggingsamplingrate(interval)from30secondsto2hours.
4 THD5-en-GB_V1.0 4/15
Startdelay
SelectaperiodoftimethatmustelapsebeforerecordingcanbeginaftertheSTART
buttonispressed(selectfrom0minto2hours).
Alarmdelay
Thepresetalarmdelaytimeforsinglealarmtypeisalwayszero.
Theadjustablealarmdelaytimeforcumulativealarm
typeis5minutesto2hours.
Alarmtypes
Regardlessofwhatalarmtypeisselected,theLEDwillcontinueflashing(onceitis
triggered)evenwhenthemeasuredvaluelaterreturnstothenormalrange.
SingleAlarm:TheLEDalarmistriggeredimmediatelywhenthemeasuredvalue
exceedsthealarmthreshold.
Cumulative:TheLEDalarmisnottriggeredwhenthemeasuredvalueexceedsthe
alarmthreshold.TheLEDalarmistriggeredonlywhentheaveragevalue,duringthe
alarmdelaytime,exceedsthealarmthreshold.
Disable:NoLEDalarmfunctionduringtheloggingprocess
Alarmvalue
Selectthealarmthresholdvalue.Forexampleif2~8
o
Cisselected:Whenthe
measuredvaluefallsbelow2
o
Corexceeds8
o
CtheLEDindicatorwilltrigger.
Unit
SelectthedesiredtemperatureunitforthePDFreport(CelsiusorFahrenheit).
TimeZone
TheTHD5LoggerautosynchronizesthetimezonewithaPCwhen‘Save’isselectedto
confirmasetting.Note:Timezonechangesoccurringduringloggingarenot
takeninto
account.
Password
ThepasswordsecurityfunctionisOFFbydefault.Thepasswordfunctioncanbe
enabledanda16alphanumericcharacter(max.)passwordcanbeusedtoprevent
unauthorizedreprogramming
Oncealltheprogrammingiscomplete,press‘Savetoconfirmthesettings.Ifdesired,close
thesetupwindowandremovetheloggerfromthePCUSBport.
Thedefaultvaluesforaboveparameters:
Samplingrate 5minutes
Startdelay 0minutes
Alarmdelay 0minutes
Temp.Unit °C
AlarmLimits
15~25
o
C
AlarmType SingleEvent
Language English
Password Disabled
CompanyName Blank
5 THD5-en-GB_V1.0 4/15
StartDatalogging
1. WhentheTHD5issuccessfullyprogrammed,thegreenLEDblinksthreetimesevery5
secondstoindicatetheloggerisinstandbymode
2. Placetheunitintothesupplied plasticbagandsealthezippedbagwell;thenpressand
holdthe‘START’buttonfortwosecondstostart
thedatalogger
3. TheRedLEDswillflashthreetimes toindicatethatthedataloggerisactivate
4. Duringthedatalogging,thegreenLEDwillblinkeverytwoseconds.Ifbatterypoweris
toolowtomaintainnormaloperation,theredLEDwillblink
5. Toplaceabookmarkmanually
duringdatalogging,pressthe‘MARK’button.Uptoeight
(8)bookmarkscanbeplacedinadatalogsession.
DownloadLoggedData(PDFReport)
Pressandholdthe‘STOP’buttonfortwosecondstostopthedatalogger(thelogger
automaticallystopswhenthelogreaches8192readings).Alternatively,plugtheloggerdirectly
intothePCUSBporttostoptheloggingandtogenerateaPDFreport.Afterafewsecondsthe
PDFreportwillbegenerated.ThePDFreportincludesreadingdataandtrendgraph.Thestatus
LEDswillblinkwhiletheloggerisgeneratingthePDFreport.
NOTE:OncetheDataloggerisStartedandthenStopped,theunitcannotbereused.Anewunit
wouldhavetobeusedtomakenew
recordings.Ten(10)loggersaresuppliedinthepackage.
6 THD5-en-GB_V1.0 4/15
Specifications
TemperatureSensor NTCThermistor
Temperaterange 30~70
o
C(22~158
o
F)
Temperatureresolution 0.1
o
C/
o
F
TemperatureAccuracy ±0.5
o
C(0.9
o
F)
Loggertype  SingleUse
Dataloggercapacity 8192readings
Samplinginterval 30seconds,5,10,30,60,90,120minutes
Startdelay 0,5,30,45,60,90,120minutes
Alarmranges 20~‐10
o
C,‐10~0
o
C,2~8
o
C,0~15
o
C,0~25
o
C,15~25
o
C,etc.
Alarmdelay 0,5,30,45,60,90,120minutes
Alarmtypes Single,Cumulative,andDisable
OperationButtons Two(2)Buttons:Start/Stop&Mark
LEDindicator Record,LowBattery,andHigh/LowAlarm
NumberofsuppliedLoggers Ten(10)singleuseloggerssuppliedinthepackage
Operatingtemperature 30~70
o
C(22~158
o
F)forlogging;
EnsureroomtemperaturewhenconnectedtoPC
OperatingRelativeHumidity <80%RH
Dimensions 80(L)x43(W)x2.5(D)mm(3.2x1.7x0.1”)
Weight ~10g(0.4oz.)
Battery One(1)3.0VCR2032battery(installedbeforeshipment)
Batterylife One(1)year
SafetyCE;
WaterproofIP65
Copyright©2015FLIRSystems,Inc.
Allrightsreservedincludingtherightofreproductioninwholeorinpartinanyform
www.extech.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Extech Instruments THD5 User manual

Type
User manual

Extech Instruments THD5 is a single-use, waterproof, and portable USB Temperature Datalogger designed for monitoring the transportation of products subject to cold chain requirements. With its user-friendly interface and advanced features, the THD5 offers reliable temperature monitoring solutions.

Key capabilities of the THD5 include:

  • Easy-to-use with intuitive programming and data retrieval process.
  • Waterproof (IP65) construction ensures protection against moisture and dust, making it suitable for various environments.
  • USB 2.0 connectivity allows for quick and convenient data transfer to a PC for analysis and report generation.

Ask a question and I''ll find the answer in the document