eSSL C3-400 is a reliable access control panel that offers advanced features for managing access to your premises. With its ability to support up to 4 doors and 4 readers, it provides a scalable solution for small to medium-sized businesses. The built-in RS485 and TCP/IP communication interfaces enable seamless integration into existing networks, allowing for remote management and data exchange with background PC software. Moreover, the C3-400 ensures uninterrupted operation during power outages with its backup battery support.

eSSL C3-400 is a reliable access control panel that offers advanced features for managing access to your premises. With its ability to support up to 4 doors and 4 readers, it provides a scalable solution for small to medium-sized businesses. The built-in RS485 and TCP/IP communication interfaces enable seamless integration into existing networks, allowing for remote management and data exchange with background PC software. Moreover, the C3-400 ensures uninterrupted operation during power outages with its backup battery support.

USER MANUAL
C3-400 Installation Instructions
and Connection Guide
www.esslsecurity.com
C 3- 400 I nstallation I nstr uctions and C onnection G uide
1. Cautions
12
3
Please note the following cautions. Mis-operation may lead to personal injury or
equipment failure:
1D o not energize the system before installation is complete; never carry out
installation activities when the system is energized.
2A ll peripheral devices must be grounded.
3T he conduits of wires under relay must be matched with metaled conduits, other
wires can use PVC conduits.
4I t is strongly recommended that the length of exposed part of any connection cable
should not be longer than 4 mm. Professional clamping tools may be used to avoid
unintentional contact of exposed wires to avoid short-circuit or communication failure.
5I t is recommended that card readers and buttons be installed at height of 1.4m-1.5m
above ground.
6I t is recommended to use the power supply for control panel, and external power
supply for each lock.
7T he appliance shall be installed and wired in accordance with national electrical
code and by qualified personnel only.
Descr iption of n or mal w or k ing state:
Connect the system to the power supply. If the system works properly, the POWER
indicator (red) is lit constantly and the RUN indicator (green) flashes.
V alve r egulated lead-acid batter y:
Constant voltage charge voltage regulation
Cycle use : 14.5V~14.9V(25)
Initial current: less than 2.88A
Standby use: 13.6V~13.8V(25)
Capacity: 12V, 7.2Ah/20hr,
Battery Type: LC-RA127R2T1
C aution:
Do not charge in a gas tight container.
Do not short the battery terminals.
Do not incinerate
Flush with water at once if contact is made with
electrolyte (Acid)
Do not attempt to disassemble the battery.
Get through the thread hole Fixed case
Control panel
The charging
circuit board
Backup battery
Heat
dissipation
hole Thread hole Key hole
Wiring the Control Panel, The Charging
Circuit Board and Backup Battery
POWER
2. Fixed and Installation
11
1
1
TX
RX
TX
RX
ACT
LINK
POWER
CARD
RUN
V+
GND
IN
BUTTON4
GND
IN
BUTTON3
GND
IN
BUTTON2
GND
+12V
WD1
WD0
READER4
GLED
BEEP
GND
+12V
WD1
WD0
READER3
GLED
BEEP
GND
+12V
WD1
WD0
READER2
GLED
BEEP
POWER
PC
LAN
NC
NC
NC
NC
COM
COM
COM
COM
NO
NO
NO
NO
COM
COM
COM
COM
NO
NO
NO
NO
NC
NC
NC
NC
LOCK1
LOCK2
LOCK4
LOCK3
GND
GND
GND
GND
SEN
SEN
SEN
SEN
V-
AUX1AUX2 AUX3 AUX4 EXT
BUTTON1
READER1
+12V
GND
WD1
WD0
GLED
BEEP
+12V
GND
485-
485+
GND
GND
GND
GND
IN
IN
IN
IN
IN
GND
GND
485-
485+
AUXOUT1AUXOUT2 AUXOUT3 AUXOUT4
LOCK
GND
+12V
1 2 3 4
ON
5 6 7 8
SD Card
Adv ance d Acc es s C ontrol
4. LED Indicators, Wires, Auxiliary Input And Output
Notes:
1)Meaning of LED indicators:
LINK indicator(green): always(green) indicates TCP/IP
ACT indicator(yellow): flashing indicates data is in transmitting
TX indicator(yellow): flashing indicates it is sending data through
RX indicator(green): flashing indicates it is receiving data through
Auxiliary output indicator(green):always(green) indicates it is in use.
Lock indicator(green):always(green) indicates lock is open.
POWER indicator(red):always(red) indicates control panel is power on.
RUN indicator(green):its flashing indicates the system works normally.
CARD indicator(yellow):its flashing indicates card is punched on reader.
A Use 2-conducotor power cord
2)Recommended use of wires
3)The auxiliary input may be connnected to infrared body detectors,
4)The auxiliary output may be connected to door bells,alarms,etc.
B Use 6-conductor wire between wiegand reader and control panel
C Use 4-conducotor lock power cord (RVV 4*0.75mm)
D Use 2-conducotor switch power cordRVV 2*0.5mm)
communication is proper;
alam switches,etc.
through TCP/IP communication.
RS485 communication.
RS485 communication.
(RVVP 6*0.5mm) (Choose the approrciate cord for the interface
you connect, such as 6,8,10 cord.)
A
A
C
C
C
C
D
D
D
D
D
D
D
D
D
B
D
B
D
B
D
B
PC RS485 interface
Ethernet interface
Dip switch
Auxiliary output1
Auxiliary output2
Auxiliary output3
Auxiliary output4
Lock1
Lock2
Lock3
Lock4
Power of lock
Power of control panel
1
1
1
1
TX
RX
TX
RX
ACT
LINK
POWER CARD
RUN
GND
IN
BUTTON4
GND
IN
BUTTON3
GND
IN
BUTTON2
GND
WD1
WD0
READER4
GLED
BEEP
GND
WD1
WD0
READER3
GLED
BEEP
GND
WD1
WD0
READER2
GLED
BEEP
POWER
PC
LAN
NC
NC
NC
NC
COM
COM
COM
COM
NO
NO
NO
NO
COM
COM
COM
COM
NO
NO
NO
NO
NC
NC
NC
NC
LOCK1LOCK2LOCK4
LOCK3
GND
GND
GND
GND
SEN
SEN
SEN
SEN
AUX1 AUX2 AUX3 AUX4 EXT
BUTTON1READER1
GND
WD1
WD0
GLED
BEEP
GND
GND
GND
GND
GND
IN
IN
IN
IN
IN
GND
GND
AUXOUT1AUXOUT2 AUXOUT3 AUXOUT4
LOCK
GND
SD Card
Advanced Access Control
485+
485-
485+
485-
+12V
+12V
+12V
+12V
+12V
V+
V-
ON
146
23578
Auxiliary input1
Auxiliary input2
Auxiliary input3
Auxiliary input4
Extended
RS485 output
1# Door Button
1# Door
W iegand reader
2# Door Button
2# Door
W
iegand reader
3# Door Button
3# Door
W
iegand reader
4#Door Button
4# Door
W iegand reader
Note
AUX Input (1-4) connect to
the infrared human body
induction, wireless exit
button, windows sensor
with dry contact (no
voltage);
Note
AUX Input (1-4) connect
way is same
Note
Output Electrical
Parameters:
Rated Voltage1 2V(DC)
Rated Current: 0.5A
Note:
1D oor button (1-4)
connect to Exit button with
dry contact.(no voltage);
2W iegand Reader (1-4)
connect to WG Reader;
Port (+12V)Output
Electrical Parameters:
Rated Voltage: 12V(DC)
Rated Current: 0.5A
Port (BEEP GLED) Output
Electrical Parameters:
Rated Voltage: 5V(DC)
Raged Current: 0.5mA
Note:
AUX Output (1-4)
connect to alarm,door
bell and so on;
Port (NO,COM,NC)
Electrical Parameters:
MAX Voltage:
36V(DC)
MAX Current: 1.25A
Note:
AUX Output (1-4)
connect way is same
SD Card Interface;
Function: Backup Access Control Logs
Note
Lock Power Input
Electrical Parameters:
Rated Voltage: 36V(DC)
Rated Current: 2A
Device Power Input
Electrical Parameters:
Rated Voltage: 12V(DC)
Rated Current: 2A
Note:
Lock(1-4):
Port (SEN)connect to door
sensor single with dry
contact (no voltage);
Port (NO, COM, NC)
Electrical Parameters:
MAX Voltage: 36V(DC)
MAX Current: 2A
Note:
When you select Wet mode,
The power is Lock power,
Lock (1-4) total load don’t
more than Lock power Rated
current (2A)
Note:
Lock (1-4) connect way is
same
1 2 3 4
ON
5 6 7 8
1
2
4
8
16
32
5
+
+
+
-
-
NC
NO
GND
COM
SEN
+
+
-
-
FR107
FR107
6. Connection Of Lock
-
LED
1
2
3
4
5
1
2
3
4
5
5. RS485 Address Setting, Restore Factory Setting, Terminal Resistance Setting
1 2 3 4
ON
5 6 7 8
Location of DIP switch
Set RS485 address through DIP switch:
1) Place 1-6 on DIP switch are for setting the number of control panels when communicating through RS485, it is adopted for binary coding,
and little endian, the address represented by place 1-6 are shown as figurue(5-1).
2) Before setting the address, please keep the system power off. Jump place 1-6 to desired status. The address number cannot be the
same as another one in the network. For example: to set the device number as 39 (39=1+2+4+32), the corresponding RS485 code is 111001,
then Jump place 1,2,3 and 6 at “ON” status.
3) Place 7 is for restoring factory default settings. Jump it for three times within 10 seconds and restart the system. All information in
control panel will be cleared and the system restores factory default settings.RAM
4) Place 8 is for setting terminal resistance when communicating through RS485. Jump it at “ON” status, then it is equivalent to having
a terminal resistance of 120 ohm between 485+ and 485-.
Figure(5-1)
Restore factory setting
RS485 terminal resistance
3) When the Electrical Lock is connected to the Access Control System, you need to parallel one FR107
diode (equipped in the package) to
prevent the self-inductance EMF affecting the system, do not reverse the polarities.
1) Control panel provides lock control output interfaces. For NO lock ,it is open when power is on, and closed when power is off, so COM and
NO interfaces should be used; For NC lock, it is open when power is off, and closed when power is on, so COM and NC interfaces should be
used.
2) Control panel supports “dry mode” and “wet mode” by setting the jumper, it is “wet mode” when connecting “V+ V-” Input interfaces to
supply power for locks, please shorten 2-3 and 4-5 . Equipment factory default setting is dry mode. For setting “dry mode” and
please refer to <<C3-100/200/400 access control panel installation instructions>>.“wet mode”,
NO Lock
LOCK
LOCK
Wet mode” wiring diagram of lock connecting with external power supply.
Enlarged diagram
of lock ports
NC Lock
Lock power
input
Diode
Diode
Jumper
terminal
11
1
1
TX
RX
TX
RX
ACT
LINK
POWER
CARD
RUN
V+
GND
IN
BUTTON4
GND
IN
BUTTON3
GND
IN
BUTTON2
GND
+12V
WD1
WD0
READER4
GLED
BEEP
GND
+12V
WD1
WD0
READER3
GLED
BEEP
GND
+12V
WD1
WD0
READER2
GLED
BEEP
POWER
PC
LAN
NC
NC
NC
NC
COM
COM
COM
COM
NO
NO
NO
NO
COM
COM
COM
COM
NO
NO
NO
NO
NC
NC
NC
NC
LOCK1LOCK2 LOCK4
LOCK3
GND
GND
GND
GND
SEN
SEN
SEN
SEN
V-
AUX1AUX2 AUX3 AUX4 EXT
BUTTON1
READER1
+12V
GND
WD1
WD0
GLED
BEEP
+12V
GND
485-
485+
GND
GND
GND
GND
IN
IN
IN
IN
IN
GND
GND
485-
485+
AUXOUT1AUXOUT2 AUXOUT3 AUXOUT4 LOCK
GND
+12V
1 2 3 4
ON
5 6 7 8
SD Card
Adva nced Acce ss Cont rol
1
1
1
1
TX
RX
TX
RX
ACT
LINK
POWER
CARD
RUN
V+
GND
IN
BUTTON4
GND
IN
BUTTON3
GND
IN
BUTTON2
GND
+12V
WD1
WD0
READER4
GLED
BEEP
GND
+12V
WD1
WD0
READER3
GLED
BEEP
GND
+12V
WD1
WD0
READER2
GLED
BEEP
POWER
PC
LAN
NC
NC
NC
NC
COM
COM
COM
COM
NO
NO
NO
NO
COM
COM
COM
COM
NO
NO
NO
NO
NC
NC
NC
NC
LOCK1LOCK2 LOCK4
LOCK3
GND
GND
GND
GND
SEN
SEN
SEN
SEN
V-
AUX1AUX2 AUX3 AUX4 EXT
BUTTON1
READER1
+12V
GND
WD1
WD0
GLED
BEEP
+12V
GND
485-
485+
GND
GND
GND
GND
IN
IN
IN
IN
IN
GND
GND
485-
485+
AUXOUT1AUXOUT2 AUXOUT3 AUXOUT4 LOCK
GND
+12V
1 2 3 4
ON
5 6 7 8
SD Card
Adv anc ed Acc ess Con trol
7. Equipment Communication
PC
PC
1 2 3 4 5 6 7 8
485+
485-
G N D
485+ 485+ 485+
485- 485- 485-
G N D G N D G N D
ON
1.TCP/IP Communication
2.RS485 Communication
The background PC software is able to communicate with the system according to two protocols(RS485 and TCP/IP) for data exchange and
remote management. The communication cable should be as far away from high-voltage lines as possible. Do not keep the communication cable
in parallel with power cords or bind them together.
Switch
n# control panel
serial line
1# control panel 2# control panel
4 8 5
Converter
DIP switch
8# control panel
2# control panel
1# control panel
1) Internationally accepted RVSP(shielded twisted-pair) wires should be used for communication to effectively avoid interference. RS485
of bus cascade connection. communication wires should be connected by means
3) One RS485 BUS may hold 63 control panel , but it is not recommended to connect with more than 32 units .units access control panels.
12345678
ON
Notes
4)To enhance the stability of communication , it is necessary to keep place 8 of DIP when the bus is longer than 300m switches of
2)Considering stability of communication, it is recommended the length of RS485 bus is less than 600m
is placed at "ON " status.
the first and the last control panel at “ON” status. As shown in the figure above, place 8 of the DIP switches of units 1# and 8#
1
1
1
1
TX
RX
TX
RX
ACT
LINK
POWER
CARD
RUN
V+
GND
IN
BUTTON4
GND
IN
BUTTON3
GND
IN
BUTTON2
GND
+12V
WD1
WD0
READER4
GLED
BEEP
GND
+12V
WD1
WD0
READER3
GLED
BEEP
GND
+12V
WD1
WD0
READER2
GLED
BEEP
POWER
PC
LAN
NC
NC
NC
NC
COM
COM
COM
COM
NO
NO
NO
NO
COM
COM
COM
COM
NO
NO
NO
NO
NC
NC
NC
NC
LOCK1
LOCK2
LOCK4
LOCK3
GND
GND
GND
GND
SEN
SEN
SEN
SEN
V-
AUX1AUX2 AUX3 AUX4 EXT
BUTTON1
READER1
+12V
GND
WD1
WD0
GLED
BEEP
+12V
GND
485-
485+
GND
GND
GND
GND
IN
IN
IN
IN
IN
GND
GND
485-
485+
AUXOUT1AUXOUT2 AUXOUT3 AUXOUT4
LOCK
GND
+12V
1 2 3 4
ON
5 6 7 8
SD Card
Adva nced Acce ss Cont rol
1
1
1
1
TX
RX
TX
RX
ACT
LINK
POWER
CARD
RUN
V+
GND
IN
BUTTON4
GND
IN
BUTTON3
GND
IN
BUTTON2
GND
+12V
WD1
WD0
READER4
GLED
BEEP
GND
+12V
WD1
WD0
READER3
GLED
BEEP
GND
+12V
WD1
WD0
READER2
GLED
BEEP
POWER
PC
LAN
NC
NC
NC
NC
COM
COM
COM
COM
NO
NO
NO
NO
COM
COM
COM
COM
NO
NO
NO
NO
NC
NC
NC
NC
LOCK1
LOCK2
LOCK4
LOCK3
GND
GND
GND
GND
SEN
SEN
SEN
SEN
V-
AUX1AUX2 AUX3 AUX4 EXT
BUTTON1
READER1
+12V
GND
WD1
WD0
GLED
BEEP
+12V
GND
485-
485+
GND
GND
GND
GND
IN
IN
IN
IN
IN
GND
GND
485-
485+
AUXOUT1AUXOUT2 AUXOUT3 AUXOUT4
LOCK
GND
+12V
1 2 3 4
ON
5 6 7 8
SD Card
Adva nced Acce ss Cont rol
11
1
1
TX
RX
TX
RX
ACT
LINK
POWER
CARD
RUN
V+
GND
IN
BUTTON4
GND
IN
BUTTON3
GND
IN
BUTTON2
GND
+12V
WD1
WD0
READER4
GLED
BEEP
GND
+12V
WD1
WD0
READER3
GLED
BEEP
GND
+12V
WD1
WD0
READER2
GLED
BEEP
POWER
PC
LAN
NC
NC
NC
NC
COM
COM
COM
COM
NO
NO
NO
NO
COM
COM
COM
COM
NO
NO
NO
NO
NC
NC
NC
NC
LOCK1
LOCK2
LOCK4
LOCK3
GND
GND
GND
GND
SEN
SEN
SEN
SEN
V-
AUX1AUX2 AUX3 AUX4 EXT
BUTTON1
READER1
+12V
GND
WD1
WD0
GLED
BEEP
+12V
GND
485-
485+
GND
GND
GND
GND
IN
IN
IN
IN
IN
GND
GND
485-
485+
AUXOUT1AUXOUT2 AUXOUT3 AUXOUT4
LOCK
GND
+12V
1 2 3 4
ON
5 6 7 8
SD Card
Adva nced Acce ss Cont rol
11
1
1
TX
RX
TX
RX
ACT
LINK
POWER
CARD
RUN
V+
GND
IN
BUTTON4
GND
IN
BUTTON3
GND
IN
BUTTON2
GND
+12V
WD1
WD0
READER4
GLED
BEEP
GND
+12V
WD1
WD0
READER3
GLED
BEEP
GND
+12V
WD1
WD0
READER2
GLED
BEEP
POWER
PC
LAN
NC
NC
NC
NC
COM
COM
COM
COM
NO
NO
NO
NO
COM
COM
COM
COM
NO
NO
NO
NO
NC
NC
NC
NC
LOCK1LOCK2LOCK4
LOCK3
GND
GND
GND
GND
SEN
SEN
SEN
SEN
V-
AUX1AUX2AUX3AUX4EXT
BUTTON1
READER1
+12V
GND
WD1
WD0
GLED
BEEP
+12V
GND
485-
485+
GND
GND
GND
GND
IN
IN
IN
IN
IN
GND
GND
485-
485+
AUXOUT1AUXOUT2 AUXOUT3 AUXOUT4 LOCK
GND
+12V
1 2 3 4
ON
5 6 7 8
SD Card
Adva nced Acce ss Cont rol
11
1
1
TX
RX
TX
RX
ACT
LINK
POWER
CARD
RUN
V+
GND
IN
BUTTON4
GND
IN
BUTTON3
GND
IN
BUTTON2
GND
+12V
WD1
WD0
READER4
GLED
BEEP
GND
+12V
WD1
WD0
READER3
GLED
BEEP
GND
+12V
WD1
WD0
READER2
GLED
BEEP
POWER
PC
LAN
NC
NC
NC
NC
COM
COM
COM
COM
NO
NO
NO
NO
COM
COM
COM
COM
NO
NO
NO
NO
NC
NC
NC
NC
LOCK1LOCK2 LOCK4
LOCK3
GND
GND
GND
GND
SEN
SEN
SEN
SEN
V-
AUX1AUX2 AUX3 AUX4 EXT
BUTTON1
READER1
+12V
GND
WD1
WD0
GLED
BEEP
+12V
GND
485-
485+
GND
GND
GND
GND
IN
IN
IN
IN
IN
GND
GND
485-
485+
AUXOUT1AUXOUT2 AUXOUT3 AUXOUT4 LOCK
GND
+12V
1 2 3 4
ON
5 6 7 8
SD Card
Adva nced Acce ss Cont rol
11
1
1
TX
RX
TX
RX
ACT
LINK
POWER
CARD
RUN
V+
GND
IN
BUTTON4
GND
IN
BUTTON3
GND
IN
BUTTON2
GND
+12V
WD1
WD0
READER4
GLED
BEEP
GND
+12V
WD1
WD0
READER3
GLED
BEEP
GND
+12V
WD1
WD0
READER2
GLED
BEEP
POWER
PC
LAN
NC
NC
NC
NC
COM
COM
COM
COM
NO
NO
NO
NO
COM
COM
COM
COM
NO
NO
NO
NO
NC
NC
NC
NC
LOCK1LOCK2 LOCK4
LOCK3
GND
GND
GND
GND
SEN
SEN
SEN
SEN
V-
AUX1AUX2 AUX3AUX4 EXT
BUTTON1
READER1
+12V
GND
WD1
WD0
GLED
BEEP
+12V
GND
485-
485+
GND
GND
GND
GND
IN
IN
IN
IN
IN
GND
GND
485-
485+
AUXOUT1AUXOUT2 AUXOUT3 AUXOUT4 LOCK
GND
+12V
1 2 3 4
ON
5 6 7 8
SD Card
Adva nced Acce ss Cont rol
#24, Shambavi Building, 23rd Main, Marenahalli, JP Nagar 2nd Phase, Bengaluru - 560078
Phone : 91-8026090500 | Email : sales@esslsecurity.com
www.esslsecurity.com
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

eSSL C3-400 User manual

Type
User manual

eSSL C3-400 is a reliable access control panel that offers advanced features for managing access to your premises. With its ability to support up to 4 doors and 4 readers, it provides a scalable solution for small to medium-sized businesses. The built-in RS485 and TCP/IP communication interfaces enable seamless integration into existing networks, allowing for remote management and data exchange with background PC software. Moreover, the C3-400 ensures uninterrupted operation during power outages with its backup battery support.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI