Instructions
Caution:
If M and (Clear) are pressed together the system will enter Calibration Mode.
How to select the measurement:
1. Press M and Mode buttons together.
2. Release to select different torque measurements (Kg-cm, Kg-m, Lbs-Inch, Ft-Lbs,
Nm)
3. The unit value will automatically change when the measurement is selected.
How to select torque settings:
1. Select and hold the (+) until the required torque is reached.
2. The target will display for 10 seconds then revert to 0.00.
3. To reduce the setting press and hold the (-).
4. Again this will display for 10 seconds then revert to 0.00.
5. Apply torque.
6. A red light will flash and an intermittent warning buzzer will sound when you are 20%
away from the target torque.
7. When full torque is reached the red light will become permanent and the buzzer will
sound constantly.
8. The required torque has been reached.
Back lit display:
1. Press and release the button ( ) for back lighting to display.
2. Press and release again to turn the back lighting off.
How to set peak:
1. Press and release the Mode button (with the wrench turned On).
2. The display will show PtoP.
3. The display will revert to 0.00 after 2 seconds.
How to set trace:
1. Press and release the Mode button (with the wrench turned On).
2. The display will show Torque load line.
3. The display will revert to 0.00 after 2 seconds.
Memorized measurements:
1. Turn the wrench On.
2. Press the M button for at least 1 second and release.
3. The display will show the memory number P01 then Torque setting.