Loctite 97504 User manual

Type
User manual

This manual is also suitable for

48
Contents
1 INTRODUCTION.................................................................... 50
2 SAFETY ................................................................................. 52
2.1 How to Use this Operating and Service Manual.................................................52
2.2 Informal Safety Measures...................................................................................53
2.3 Intended Use, Warranty......................................................................................53
2.4 Qualification of Operating and Service Staff.......................................................53
2.4.1 Operating staff ....................................................................................................54
2.4.2 Servicing staff .....................................................................................................54
2.5 Organisational Measures....................................................................................54
2.6 Risk Sources.......................................................................................................55
2.7 Safety Systems...................................................................................................55
2.8 Preparation for Operation – Visual Inspection....................................................56
2.9 Safeguard Against Unauthorised Use.................................................................56
3 OPERATION .......................................................................... 57
3.1 Dispensing Station – Total View.........................................................................57
3.2 Displays and Operating Elements.......................................................................58
3.3 Initial Start-up......................................................................................................59
3.3.1 Unpacking...........................................................................................................59
3.3.2 Transportation.....................................................................................................59
3.3.3 Installation...........................................................................................................59
3.3.4 Initial priming with product ..................................................................................60
3.4 Calibration of pumps...........................................................................................62
3.5 Replace Product Container.................................................................................64
3.6 Factory Settings..................................................................................................66
3.7 Operator menu settings ......................................................................................66
3.7.1 Volume ratio........................................................................................................67
3.7.2 Product specific adaptation of the dispensing system........................................68
3.7.3 Maximum pump capacity....................................................................................69
3.7.4 Operating mode..................................................................................................69
3.7.5 Dispense time.....................................................................................................70
3.8 Service menu setup............................................................................................71
3.8.1 Enter password...................................................................................................72
3.8.2 Retract time.........................................................................................................72
3.8.3 Automatic mixer flush cycle (optional) ................................................................73
3.8.4 Flush time (optional) ...........................................................................................74
3.8.5 Enter calibration factor........................................................................................75
3.8.6 Select User Interface language...........................................................................75
49
Contents
3.9 Shutdown............................................................................................................76
3.10 Return to Operation ............................................................................................76
4 OPERATOR MENU PROGRAMMING................................... 77
4.1 Operator Menu Flow Chart .................................................................................77
4.2 Service Menu Flow Chart....................................................................................78
4.3 Messages............................................................................................................79
5 MAINTENANCE..................................................................... 80
5.1 Service Intervals .................................................................................................80
5.2 Cleaning the Pump .............................................................................................80
5.3 Replacing Stator / Wiper Ring.............................................................................81
5.3.1 Unscrew pump unit.............................................................................................81
5.3.2 Disassembling the pump – Removing the stator ................................................82
5.3.3 Replacing the wiper ring .....................................................................................82
5.3.4 Re-assembling the pump – Re-installing the stator............................................83
5.4 Cleaning the Meter-Mix Dispense Gun...............................................................85
6 TROUBLESHOOTING........................................................... 85
7 SPARE AND WEARING PARTS........................................... 86
8 TECHNICAL SPECIFICATION.............................................. 87
8.1 Declaration of Conformity ...................................................................................87
8,2 Terminal Block Pin Assignment X1, X2 and X3.................................................88
8.2.1 Terminal Block X1 Motor A.................................................................................88
8.2.2 Terminla Block X2 Motor B.................................................................................89
8.2.3 Terminal Block X3 Signal Exchange...................................................................89
8.2.4 Pin Assignment XS1 Start...................................................................................89
8.2.5 Pin Assignment XS 2 Docking Station for meter-mix Dispense Gun..................89
8.3 Technical Data....................................................................................................91
8.4 Approved Products .............................................................................................92
9 DISPOSAL............................................................................. 93
50
1 Introduction
Dear Customer,
Congratulations on your purchase of this dual dispensing system. We are sure it will
fully meet your needs and will provide smooth and trouble free operation.
Properly handled and maintained, the system will give you many years of efficient
use.
Of course we also need your support to help us ensure ongoing compliance with top
quality standards. We are always on the look out for ways to improve our products
and would appreciate your comments or suggestions.
Any questions? Please contact us:
Henkel Loctite Deutschland GmbH
Arabellastraße 17
D-81925 München
Phone +49 (0)89 – 9268 - 0
Fax +49 (0)89 – 910 1978
Internet www.loctite.com
"Loctite" is a Registered Trademark of Henkel Loctite Corporation
51
1 Introduction
Theory of operation
This Dual Rotor Pump Dispenser has been specially designed and tested for
application of the Loctite
®
Hysol
®
range of products.
It has two separately operating pump units, which can be controlled individually.
These pumps deliver a nearly pulsation free flow of material and offer efficient
performance at high pressure.
The electronic pump control system provides accurate control of product component
mixing ratios and allows all settings required for trouble-free operation.
Mixing of the two parts of the product occurs within the pneumatically operated
meter-mix dispense gun. Depending on the setting, material is dispensed either timed
or manually controlled.
To prevent post-dispense dripping, an adjustable amount of product is sucked back
by reversing the direction of rotation.
Positioning of the meter-mix dispense gun in the optional docking station is detected
by an induction sensor, where the electronic pump control system triggers a purging
cycle which can be set to run at regular intervals. This effectively prevents mixers
from becoming blocked and maintains full operational capability of the dispensing
station also in case of prolonged idle times.
The pumps are equipped with quick-connect clamping fixtures for connection to the
drive motors. Whenever a different product is to be processed, the meter-mix
dispense gun with its tubes and lines can be replaced without the use of tools.
Product availability (filled product container), maximum operating pressure and the
pump motors are monitored electronically. In case of failure the electronic pump
controller shuts the dispensing station off and displays a relevant error message.
A receptacle prevents deformation of the container as well as product escaping
during the operating process. 3 centering pins are provided for correct alignment with
the pump unit.
52
2 Safety
For safe and successful operation of the unit, read these instructions completely.
The manufacturer cannot be held responsible for damage or injury of any kind
because of misuse or improper application or because of failure to observe safety
instructions or warnings.
Be sure to keep this manual handy for future reference.
Please refer also to the relevant Technical Data Sheet for the adhesive to be
processed. Download from www.loctite.com or request the Technical Data Sheet
and the Safety Data Sheet (acc. to EU Directive 91/155/EC): Contact
Henkel Loctite Deutschland GmbH
+49 89 92 68 11 67 for the English language version of the data sheet;
089-92 68 11 22 for the German language version of the data sheet.
Be sure to follow the instructions of these data sheets!
2.1 How to Use this Operating and Service Manual
Wherever possible, this manual has been structured in a way to feature text and the
relevant illustration on the same page for easy understanding.
Callout numbers are given for cross-reference to any component displayed in an
illustration.
For clarity, legends in illustrations always refer to only one of the two mirrors inverted
pump units.
If the component referred to is a spare part, it will be listed in the spare parts list –
see Section 7.
The following symbols are used:
• Operational step
1. Operational step, numbered consecutively
– List
(1) (A) Item references for components in the illustration
*
Refers to a Note
Text in italics
Refers to a display message; Enter key, electronic pump controller
Bold text
Outline, Note
Danger!
Refers to safety regulations and requires safety measures that protect
the equipment operator or other persons from injury or danger to life.
Note
Gives recommendations for better handling of the unit during
operation or adjustment as well as for service activities
Mechanical installation may present crush hazard!
53
2 Safety
2.2 Informal Safety Measures
Always keep this manual readily available at the operating site.
In addition to the operating manual, provide and observe general and local
regulations for accident prevention and environmental protection.
All safety and hazard warnings on the equipment must always be kept legible.
2.3 Intended Use, Warranty
The Dual Rotor Pump Dispenser has been designed for accurate dispensing of
Loctite
®
Hysol
®
adhesives and sealants.
A list of approved products is provided in Section 8.4. Additional products may be
approved on request.
As the viscosities of the components of Loctite
®
Hysol
®
9463 differ significantly, the
equipment is not suitable for dispensing this product.
For any further questions relating to dispensing capabilities for this product please
contact your local Henkel Loctite Technical Service department.
Without the express written approval by the manufacturer, any
modifications or additions
use of unauthorised products
use of non-original spare parts
repairs performed by persons or companies not authorised by the
manufacturer
may result in loss of guarantee and warranty.
We cannot be held responsible for damage or injury of any kind because of failure to
observe the instructions in this Operating and Service Manual.
The dispensing station is not intended for use in potentially explosive areas.
2.4 Qualification of Operating and Service Staff
The provider/operator of the equipment is responsible for providing staff with the
required qualification. He has to make sure that only authorised staff will be assigned
to work on the dispensing station. We recommend that operating and servicing staff
should be required to provide confirmation in writing that they have taken note of the
instructions in this Operating and Service Manual.
Work inside the equipment, e.g. at the terminal block, may be accomplished
only by adept maintenance staff, see section 2.4.2.
54
2 Safety
2.4.1 Operating staff
Any persons operating and working with the dispensing station must be sufficiently
trained for the activities involved. The contents of the Operating and Service Manual
must have been read and understood.
2.4.2 Servicing staff
Any persons charged with maintenance and repair of the dispensing station must be
qualified and
Must be sufficiently trained for the activities involved
Must be aware of and comply with the pertinent technical rules and safety
regulations
Must have read and understood the contents of the Operating and Service
Manual.
A person is qualified if he/she has an educational background and experience
providing adequate knowledge in the fields of hydraulics, pneumatics, materials
handling and electrical engineering, and is sufficiently familiar with the pertinent
occupational health and safety and accident prevention procedures, the regulations
and generally accepted engineering standards (DIN standards) to be capable of
assessing if the dispensing station is in a safe operating condition.
2.5 Organisational Measures
The provider/operator of the equipment is responsible for providing staff with the
required personal protective equipment. All existing safety systems must be checked
at regular intervals. Wear safety goggles and protective suit during operation and
cleanup to protect against any chemical splashes.
55
2 Safety
2.6 Risk Sources
The following risk sources may be associated with the operation of the dispensing
station:
Failure to comply with these instructions could result in material
damage and death or serious injury of humans.
Depending on the pump capacity setting, product will be fed at a pressure of up to
40 bar. Product escaping from defective tubing or components may result in
injuries and material damage due to splashing product.
During initial start-up and subsequent transfer of product to refill the reservoir, air
bubbles trapped within the product may cause uncontrolled squirting from the
meter-mix dispense gun. Tubes should always be depressurised completely before
starting operation.
Wear suitable protective clothing whenever processing chemical or corrosive
materials or products, which pose potential health risks. Comply with safety
regulations and observe the manufacturer’s instructions. Provide adequate
ventilation or exhaust system. Take special precautionary measures whenever
hazardous materials are involved, provide e.g. an eyewash station in case of
corrosive chemicals.
Only staff possessing special skills and experience must be allowed to handle
pneumatic, hydraulic and electrical equipment.
When the pump unit is lowered onto the product container there is a
risk of fingers getting crushed. An appropriate safety label is affixed to
the dispensing station!
2.7 Safety Systems
The electronic pump control system monitors
The operating pressure,
Product availability in the two containers, and
Electrical connection of the two pump motors.
If
Operating pressure exceeds 40 bar,
There is no product left in one or both containers,
One of the two electrical pump motor terminals is not connected,
the dispensing station is shut off and a relevant error message is displayed. The
error must be corrected and the fault signal reset to resume operation.
56
2 Safety
2.8 Preparation for Operation – Visual Inspection
Perform a visual inspection of the dispensing station every day before you start to
work and before each change of shift. If there are any doubts regarding correct
operational capability, the system must be shut down immediately and presented to
qualified staff for inspection before operation is continued.
2.9 Safeguard Against Unauthorised Use
An effective safeguard against unauthorised use can be achieved by
Removing the power cord, and
Removing the fuse plug (from power switch).
In addition to any action taken, position a clearly visible and legible written notice,
e.g. on the power switch, to prohibit operation of the unit.
57
3 Operation
The safety instructions in Section 2, "Safety" must have been read
and understood before operating the dispensing station.
3.1 Dispensing Station – Total View
A
Control cabinet
K
Connector, pneumatics
B
Base plate
L
Carrying handle
C
Pressure switch
M
Power switch, Fuse plug, Socket
D
Pump motor
N
Receptacle
E
Planetary gearbox
O
Vent screw
F
Type plate
G
Locking screw
P
Electronic pump controller with
display
H
Pump unit
R
Speed selector switch (output)
S
Follower plate with wiper ring
T
Meter-mix Dispense Applicator
U
Docking station for meter-mix
dispense applicator (optional)
J
Tubing set consists of:
– Feedlines,
– Compressed air hose
meter-mix
dispense applicator
0 (applicator
closed)
– Compressed air hose
meter-mix
dispense applicator I (applicator
open)
W
Connector, docking station for meter-
mix dispense applicator
58
3 Operation
3.2 Displays and Operating Elements
Display, Electronic Controller
The dispensing station is equipped with an electronic controller. For descriptions of
settings please refer to:
– Sections 3.7.1 ff
the flow chart in Section 4.
The display of the electronic controller reads as follows when the system is in ready
state:
or
Display Short description Page
Cont. operating mode (optional, if selected: Timed mode nn.n sec.) 69
A : B Ratio by volume, product A vs. B 66
Max. Maximum speed of rotation (output), pump motor 69
OK Jump to next menu
* Jump to service menu (push 2x)
ALT Jump to dispense time setup
(Go to the above-mentioned pages for a detailed description of display items)
1 Speed controller (pump output) 0 – 100 %
2 ESC, Leave the current operation or setup menu
3 Cursor, Input adjustments and navigation
4 OK, Acknowledge, Jump to next menu
5
*
Key, Access to service menu
6
Display
7 ALT, if ALT appears, Jump directly to dispense time setup
7
DualRotorPumpDispenser
OK
Cont.
A:B
2.00:1
Max.
70%
OK
Time
9.2 sec.
A:B
2.00:1
Max.
70%
OK
59
3 Operation
3.3 Initial Start-up
3.3.1 Unpacking
Remove shipping materials.
Check that items supplied are complete and match delivery note.
3.3.2 Transportation
The dispensing station has two carrying handles (L) at the sides – see Section 3.2.
Requires a minimum of two persons to carry.
Suitable for transportation by pallet trucks.
3.3.3 Installation
Install in a suitable location. Provide:
Power supply, socket.
Compressed air supply.
Position docking station for meter-mix dispense gun (optional).
Plug connecting cable of dispense gun docking station (U) to connector (W)
(on the rear of the dispensing station) (optional).
For start-up please refer to Section 3.3.4.
Do not switch the dispensing station on. Material damage can result
by running the system without product being pumped through it!
60
3 Operation
3.3.4 Initial priming with product
Preparation
Switch dispensing station off and safeguard against unauthorised use.
Disconnect compressed air supply.
Observe safety regulations.
Positioning of Product Container A
Raise Pump Unit A (D) to top position and hold.
Lightly hand tighten the locking screw (G). Pump unit is locked into place in top
position.
Insert product container into Receptacle (N) and position underneath Pump Unit A,
between the 3 centering pins.
Unscrew vent screw (O) from follower plate (S).
Hold Pump Unit A and back off locking screw (G).
Lower the pump unit slowly until follower plate rests against the container rim.
Gently press down with your hand to lower Pump Unit A until product flows from
bleed port (Z).
Lightly hand tightens the locking screw. Pump unit is locked into place.
Screw vent screw into the bleed port of the follower plate.
Back off locking screw. Pump Unit A rests by its own weight on top of the product.
Crush hazard: Risk of fingers getting crushed when pump unit is
lowered. Do not allow fingers to get between follower plate and
receptacle and/or product container.
61
3 Operation
Bleeding of Tubing A
Make a mark on the inside of the product container on a level with wiper ring (S) of
Pump Unit A. Pump operation can be checked by monitoring the movement of the
follower plate (lowering of the wiper ring).
Unscrew vent screw (Z).
Connect compressed air supply.
Switch the dispensing station on.
Set speed selector switch (R) to medium speed.
Switch to Service Mode, see Section 3.8.1.
Disconnect pump motor plug (Y) of Pump Unit B to prevent unprimed pump from
running dry and avoid any unwanted discharge of product B.
Keeping an eye on the mark, briefly actuate the meter-mix dispense gun. The
pump is discharging product when the wiper ring is coming down.
Actuate the meter-mix dispense gun until product flows from the bleed port (Z).
Wipe product off with a suitable material (cloth).
Screw vent screw (Z) back in place.
Actuate the meter-mix dispense gun until product flows free of bubbles and air
inclusions. Wipe product off with a suitable material (cloth).
Caution: If the wiper ring does not come down within >30 seconds, the pump is not
feeding any product (risk of material damage). Be sure to repeat procedure as
described under heading "Positioning of Product Container A".
Dispensing for the first time from the meter-mix gun may result in
danger due to splashing product. Air bubbles may result in
uncontrolled splashing. Be sure to keep a safe distance and hold the
dispense gun in an appropriate and safe position!
62
3 Operation
Positioning of Product Container B, and bleeding of Tubing B.
Proceed analogously and in a mirror inverted manner, as described above for
Product Container and Tubing A.
3.4 Calibration of pumps
Calibration is achieved by determining the ratio of capacities of the two pump units.
The capacity of pump A is the reference value for pump B. The calibration factor is
used for matching the capacity of pump B with that of pump A.
Determination of pump capacity, Pump Unit A
Switch the dispensing station on.
Set calibration factor to 100%, see Section 3.8.5.
Set volume ratio to 1:1 , see Section 3.7.1.
Set speed selector switch (R) to medium speed.
Switch to Service Mode, see Section 3.8.1.
Disconnect pump motor plug (Y) of Pump Unit B
Actuate the meter-mix dispense gun (T) for 10 seconds. Catch material dispensed
in a suitable container.
Weigh amount of material dispensed.
63
3 Operation
Determination of pump capacity, Pump Unit B
Leave speed selector switch setting unchanged.
Leave volume ratio setting of 1:1 unchanged.
Proceed analogously and in a mirror inverted manner, as described above for
Determination of pump capacity, Pump Unit A.
Determination of calibration factor
Example for calibration factor calculation:
X = amount of product A discharged 10 grams
Y = amount of product B discharged 11 grams
Fill measuring cup (30 – 50ml) one third full with water, dispense and read off
the amount discharged.
Formula: X/(Y:100) = calibration factor 10/(11:10) = 90.9 %
For the description how to enter the calibration factor go to Section 3.8.5.
64
3 Operation
3.5 Replace Product Container
Preparation
Switch dispensing station off and safeguard against unauthorised use.
Disconnect compressed air supply.
Observe safety regulations.
Remove empty product container
Raise Pump Unit (A) to top position (direction of arrow) and hold.
Lightly hand tighten the locking screw (G). Pump unit is locked into place in top
position.
Unscrew vent screw (O) from follower plate (S).
Pull Receptacle (N) downward until it comes off.
Pull empty product container downward until it comes off.
Use suitable tool (spatula, piece of wood) to clean follower plate and wiper ring (B)
to remove coarse contamination from product residues.
65
3 Operation
Install full product container
Insert product container into Receptacle (N) and position underneath the Pump
Unit, between the 3 centering pins.
Hold Pump Unit and back off locking screw (G).
Lower the pump unit slowly until follower plate (S) rests against the container rim.
Gently press down with your hand to lower the Pump Unit until product flows from
bleed port (Z).
To prevent additional product from escaping, raise pump unit a bit and lightly hand
tighten the locking screw. Pump unit is locked into place.
Screw vent screw (O) into the bleed port of the follower plate.
Back off locking screw. Pump Unit rests by its own weight on top of the product.
Depending on the product being used, air bubbles entrapped after
replacement of the product container may result in uncontrolled
splashing from the dispense gun. Be sure to keep a safe distance
and hold the dispense gun in an appropriate and safe position.
In addition, tubes can be bled as described in Section 3.3.4,
Bleeding of Tubing A .
Crush hazard: Risk of fingers getting crushed when pump unit is
lowered. Do not allow fingers to get between follower plate and
receptacle and/or product container.
66
3 Operation
3.6 Factory Settings
Factory settings of the Dual Rotor Pump Dispenser are as follows:
Menu item Setting
Operator menu
Continuous mode On
Volume behaviour 1.00 : 1
Adaptation 100 %
Max. pump efficiency (range max.) 100 %
Dispense time 0.1 sec.
Service menu
Retract time 0.3 sec.
Automatic mixer flushing every 10 min
Flush time 0.1 sec.
Calibration factor 100 %
Interface language English
3.7 Operator menu settings
The electronic pump control system allows settings for all parameters required for
operation. The operator menu allows the following settings:
Menu Page
3.7.1 Volume Ratio 66
3.7.2 Product specific adaptation of the dispensing system 68
3.7.3 Maximum pump capacity 69
3.7.4 Operating mode (continuous or timed mode) 69
3.7.5 Dispense time 70
Refer to Section 4.1 for the Operator menu flow chart.
67
3 Operation
3.7.1 Volume ratio
Setting reflects output of Pump Unit A vs. Pump Unit B. The output amount of
pump B is the reference value and is assigned a factor of 1.
The volume ratio setting is indicated in the Operation display.
Volume ratio setup:
With the dispensing station in ready state, push OK button - display indicates
volume ratio.
Use arrow keys to enter desired value.
Arrow key assignment / setting range:
left: -0.5; right: +0,5; up: +0,05;
down: -0,05; setting range: 1.0 – 6.0
• Push OK button to save the setting – display indicates "next menu item". Push
ESC key to leave the operator menu – display indicates Operation.
For volume ratio setup refer to and follow exactly the instructions on product
containers.
OK/ESC
A:B 1.00:1 100%
*
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94

Loctite 97504 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

in other languages