Vega VEGACAL 69 Operating instructions

Category
Measuring, testing & control
Type
Operating instructions
Operating Instructions
Capacitive double rod electrode for level
measurement
VEGACAL 69
4 … 20 mA/HART - two-wire
Document ID: 31178
2
Contents
VEGACAL 69 • 4 … 20 mA/HART - two-wire
31178-EN-170503
Contents
1 About this document
1.1 Function ........................................................................................................................... 4
1.2 Target group ..................................................................................................................... 4
1.3 Symbols used................................................................................................................... 4
2 For your safety
2.1 Authorised personnel ....................................................................................................... 5
2.2 Appropriate use ................................................................................................................ 5
2.3 Warning about incorrect use ............................................................................................. 5
2.4 General safety instructions ............................................................................................... 5
2.5 Safety label on the instrument .......................................................................................... 6
2.6 EU conformity ................................................................................................................... 6
2.7 FulllmentofNAMURrecommendations ......................................................................... 6
2.8 Installation and operation in the USA and Canada ........................................................... 6
2.9 Safety instructions for Ex areas ........................................................................................ 6
2.10 Environmental instructions ............................................................................................... 6
3 Product description
3.1 Conguration .................................................................................................................... 8
3.2 Principle of operation........................................................................................................ 9
3.3 Adjustment ..................................................................................................................... 10
3.4 Packaging, transport and storage ................................................................................... 11
3.5 Accessories and replacement parts ............................................................................... 11
4 Mounting
4.1 General instructions ....................................................................................................... 13
4.2 Mountinginstructions ..................................................................................................... 14
5 Connecting to power supply
5.1 Preparing the connection ............................................................................................... 15
5.2 Connection procedure .................................................................................................... 16
5.3 Wiring plan, single chamber housing.............................................................................. 17
5.4 Wiring plan, double chamber housing ............................................................................ 19
5.5 Wiring plan, Ex-d double chamber housing .................................................................... 21
5.6 Wiring plan - version IP 66/IP 68, 1 bar ........................................................................... 23
6 Set up with the display and adjustment module PLICSCOM
6.1 Short description ............................................................................................................ 24
6.2 Insert display and adjustment module ............................................................................ 24
6.3 Adjustment system ......................................................................................................... 25
6.4 Setup steps .................................................................................................................... 26
6.5 Menuschematic ............................................................................................................. 36
6.10 Saving the parameterisation data ................................................................................... 37
7 Set up with PACTware and other adjustment programs
7.1 Connect the PC .............................................................................................................. 38
7.2 Parameter adjustment with PACTware ............................................................................ 39
7.3 ParameteradjustmentwithAMS™andPDM ................................................................. 40
7.4 Saving the parameterisation data ................................................................................... 41
8 Maintenanceandfaultrectication
8.1 Maintenance .................................................................................................................. 42
3
Contents
VEGACAL 69 • 4 … 20 mA/HART - two-wire
31178-EN-170503
8.2 Rectify faults ................................................................................................................... 42
8.3 Exchanging the electronics module ................................................................................ 43
8.4 How to proceed if a repair is necessary .......................................................................... 44
9 Dismount
9.1 Dismounting steps.......................................................................................................... 45
9.2 Disposal ......................................................................................................................... 45
10 Supplement
10.1 Technical data ................................................................................................................ 46
10.2 Dimensions .................................................................................................................... 52
10.3 Industrial property rights ................................................................................................. 54
10.4 Trademark ...................................................................................................................... 54
Supplementary documentation
Information:
Supplementary documents appropriate to the ordered version come
withthedelivery.Youcanndthemlistedinchapter"Product descrip-
tion".
Instructions manuals for accessories and replacement parts
Tip:
ToensurereliablesetupandoperationofyourVEGACAL69,weoer
accessories and replacement parts. The corresponding documenta-
tions are:
27720 - VEGADIS 61
30531 - Electronics module VEGACAL series 60
34296 - Protective cover
31088-FlangesaccordingtoDIN-EN-ASME-JIS
Editing status: 2017-04-06
4
1 About this document
VEGACAL 69 • 4 … 20 mA/HART - two-wire
31178-EN-170503
1 About this document
1.1 Function
This operating instructions manual provides all the information you
need for mounting, connection and setup of the instrument. Further-
morethereareimportantinstructionsformaintenance,faultrectica-
tion, the exchange of parts and the safety of the user. Please read this
information before putting the instrument into operation and keep this
manual accessible in the immediate vicinity of the device.
1.2 Target group
This operating instructions manual is directed to trained specialist
personnel. The contents of this manual should be made available to
these personnel and put into practice by them.
1.3 Symbols used
Information, tip, note
This symbol indicates helpful additional information.
Caution: If this warning is ignored, faults or malfunctions can result.
Warning: If this warning is ignored, injury to persons and/or serious
damage to the instrument can result.
Danger: If this warning is ignored, serious injury to persons and/or
destruction of the instrument can result.
Ex applications
This symbol indicates special instructions for Ex applications.
SIL applications
This symbol indicates instructions for functional safety which must be
taken into account particularly for safety-relevant applications.
List
The dot set in front indicates a list with no implied sequence.
→
Action
This arrow indicates a single action.
1 Sequence of actions
Numbers set in front indicate successive steps in a procedure.
Battery disposal
This symbol indicates special information about the disposal of bat-
teries and accumulators.
5
2 For your safety
VEGACAL 69 • 4 … 20 mA/HART - two-wire
31178-EN-170503
2 For your safety
2.1 Authorised personnel
All operations described in this operating instructions manual must
be carried out only by trained specialist personnel authorised by the
plant operator.
During work on and with the device the required personal protective
equipment must always be worn.
2.2 Appropriate use
VEGACAL 69 is a sensor for continuous level measurement.
Youcannddetailedinformationabouttheareaofapplicationin
chapter"Product description".
Operational reliability is ensured only if the instrument is properly
usedaccordingtothespecicationsintheoperatinginstructions
manual as well as possible supplementary instructions.
For safety and warranty reasons, any invasive work on the device
beyond that described in the operating instructions manual may be
carried out only by personnel authorised by the manufacturer. Arbi-
traryconversionsormodicationsareexplicitlyforbidden.
2.3 Warning about incorrect use
Inappropriate or incorrect use of the instrument can give rise to
application-specichazards,e.g.vesseloverllordamagetosystem
components through incorrect mounting or adjustment. Thus dam-
age to property, to persons or environmental contamination can be
caused. Also the protective characteristics of the instrument can be
inuenced.
2.4 General safety instructions
This is a state-of-the-art instrument complying with all prevailing
regulations and directives. The instrument must only be operated in a
technicallyawlessandreliablecondition.Theoperatorisresponsi-
ble for the trouble-free operation of the instrument. When measuring
aggressive or corrosive media where a malfunction of the instrument
can cause a danger, the operator has to convince himself on the cor-
rect function of the instrument by taking suitable measures.
During the entire duration of use, the user is obliged to determine the
compliance of the necessary occupational safety measures with the
current valid rules and regulations and also take note of new regula-
tions.
The safety instructions in this operating instructions manual, the na-
tional installation standards as well as the valid safety regulations and
accident prevention rules must be observed by the user.
For safety and warranty reasons, any invasive work on the device
beyond that described in the operating instructions manual may be
carried out only by personnel authorised by the manufacturer. Arbi-
traryconversionsormodicationsareexplicitlyforbidden.Forsafety
6
2 For your safety
VEGACAL 69 • 4 … 20 mA/HART - two-wire
31178-EN-170503
reasons,onlytheaccessoryspeciedbythemanufacturermustbe
used.
To avoid any danger, the safety approval markings and safety tips on
the device must also be observed and their meaning looked up in this
operating instructions manual.
2.5 Safety label on the instrument
The safety approval markings and safety tips on the device must be
observed.
2.6 EU conformity
ThedevicefullsthelegalrequirementsoftheapplicableEUdirec-
tives.ByaxingtheCEmarking,weconrmsuccessfultestingofthe
product.
YoucanndtheEUconformitydeclarationonourwebsiteunder
www.vega.com/downloads.
2.7 FulllmentofNAMURrecommendations
NAMURistheautomationtechnologyuserassociationintheprocess
industryinGermany.ThepublishedNAMURrecommendationsare
acceptedasthestandardineldinstrumentation.
ThedevicefullstherequirementsofthefollowingNAMURrecom-
mendations:
NE 21 – Electromagnetic compatibility of equipment
NE 43 – Signal level for fault information from measuring transduc-
ers
NE53–Compatibilityofelddevicesanddisplay/adjustment
components
For further information see www.namur.de.
2.8 Installation and operation in the USA and
Canada
This information is only valid for USA and Canada. Hence the follow-
ing text is only available in the English language.
Installations in the US shall comply with the relevant requirements of
the National Electrical Code (ANSI/NFPA 70).
Installations in Canada shall comply with the relevant requirements of
the Canadian Electrical Code
2.9 Safety instructions for Ex areas
PleasenotetheEx-specicsafetyinformationforinstallationandop-
eration in Ex areas. These safety instructions are part of the operating
instructions manual and come with the Ex-approved instruments.
2.10 Environmental instructions
Protection of the environment is one of our most important duties.
That is why we have introduced an environment management system
7
2 For your safety
VEGACAL 69 • 4 … 20 mA/HART - two-wire
31178-EN-170503
with the goal of continuously improving company environmental pro-
tection.Theenvironmentmanagementsystemiscertiedaccording
to DIN EN ISO 14001.
Pleasehelpusfullthisobligationbyobservingtheenvironmental
instructions in this manual:
Chapter"Packaging, transport and storage"
Chapter"Disposal"
8
3 Product description
VEGACAL 69 • 4 … 20 mA/HART - two-wire
31178-EN-170503
3 Product description
3.1 Conguration
The scope of delivery encompasses:
Level sensor VEGACAL 69
Documentation
This operating instructions manual
SafetyManual"Functional safety (SIL)"(optional)
Supplementaryinstructionsmanual"Heating for display and
adjustment module"(optional)
Supplementaryinstructionsmanual"Plug connector for con-
tinuously measuring sensors"(optional)
Ex-specic"Safety instructions"(withExversions)
Ifnecessary,furthercerticates
The VEGACAL 69 consists of the components:
Processttingwithprobe
Housing with electronics
Housing cover, optionally available with display and adjustment
module
1
2
3
Fig. 1: VEGACAL 69 - double rod probe with plastic housing
1 Housing lid with integrated display and adjustment module (optional)
2 Housing with electronics
3 Processtting
Thetypelabelcontainsthemostimportantdataforidenticationand
use of the instrument:
Scope of delivery
Constituent parts
Type label
9
3 Product description
VEGACAL 69 • 4 … 20 mA/HART - two-wire
31178-EN-170503
2
1
11
13
12
14
15
10
9
3
6
4
5
7
8
Fig. 2: Layout of the type label (example)
1 Instrument type
2 Product code
3 Approvals
4 Process and ambient temperature, process pressure
5 Power supply and signal output, electronics
6 Protection rating
7 Probe length
8 Order number
9 Serial number of the instrument
10 Material, wetted parts
11 Symbol of the device protection class
12 Reminder to observe the instrument documentation
13 ID numbers, instrument documentation
14 NotiedauthorityforCEmarking
15 Approval directives
With the serial number, you can access the delivery data of the instru-
mentvia"www.vega.com","VEGA Tools"and"Instrument search".
Youcanndtheserialnumberontheinsideoftheinstrumentaswell
as on the type label on the outside.
3.2 Principle of operation
VEGACAL 69 is a level sensor for continuous level measurement of
liquids in non-conductive vessels or of corrosive liquids.
The double rod probe is fully insulated and highly resistant.
Probes and measured product form an electrical capacitor. The
capacitanceisinuencedbythreemainfactors.
Application area
Functional principle
10
3 Product description
VEGACAL 69 • 4 … 20 mA/HART - two-wire
31178-EN-170503
1
2
3
Fig. 3: Functional principle - Plate capacitor
1 Distance between the electrode surfaces
2 Size of the electrode surfaces
3 Type of dielectric between the electrodes
The two probes are the capacitor plates. The measured product is
the dielectric. Due to the higher dielectric constant of the product
compared to air, the capacitance increases as the material gradually
covers the probe.
The capacitance as well as the resistance change are converted by
the electronics module into a level-proportional signal.
4 … 20 mA/HART two-wire electronics for voltage supply and meas-
ured value transmission on the same cable.
Thesupplyvoltagerangecandierdependingontheinstrument
version.
Thedataforpowersupplyarespeciedinchapter"Technical data".
The backlight of the display and adjustment module is powered by
the sensor. The prerequisite for this is a supply voltage at a certain
level.Theexactvoltagespecicationsarestatedinchapter"Technical
data".
Theoptionalheatingrequiresitsownpowersupply.Youcannd
furtherdetailsinthesupplementaryinstructionsmanual"Heating for
display and adjustment module".
This function is generally not available for approved instruments.
3.3 Adjustment
The instrument can be adjusted with the following adjustment media:
With the display and adjustment module
withthesuitableVEGADTMinconjunctionwithanadjustment
softwareaccordingtotheFDT/DTMstandard,e.g.PACTwareand
PC
Withmanufacturer-specicadjustmentprogramsAMS™orPDM
With a HART handheld
Voltage supply
11
3 Product description
VEGACAL 69 • 4 … 20 mA/HART - two-wire
31178-EN-170503
3.4 Packaging, transport and storage
Your instrument was protected by packaging during transport. Its
capacity to handle normal loads during transport is assured by a test
based on ISO 4180.
The packaging of standard instruments consists of environment-
friendly, recyclable cardboard. For special versions, PE foam or PE
foil is also used. Dispose of the packaging material via specialised
recycling companies.
Transport must be carried out in due consideration of the notes on the
transport packaging. Nonobservance of these instructions can cause
damage to the device.
The delivery must be checked for completeness and possible transit
damage immediately at receipt. Ascertained transit damage or con-
cealed defects must be appropriately dealt with.
Up to the time of installation, the packages must be left closed and
stored according to the orientation and storage markings on the
outside.
Unless otherwise indicated, the packages must be stored only under
the following conditions:
Not in the open
Dry and dust free
Not exposed to corrosive media
Protected against solar radiation
Avoiding mechanical shock and vibration
Storageandtransporttemperatureseechapter"Supplement -
Technical data - Ambient conditions"
Relative humidity 20 … 85 %
With an instrument weight of more than 18 kg (39.68 lbs) suitable and
approved equipment must be used for lifting and carrying.
3.5 Accessories and replacement parts
ThedisplayandadjustmentmodulePLICSCOMisusedformeasured
value indication, adjustment and diagnosis. It can be inserted into the
sensor and removed at any time.
The integrated Bluetooth module (optional) enables wireless adjust-
ment via standard adjustment devices:
1)
Smartphone/tablet (iOS or Android operating system)
PC/notebook with Bluetooth USB adapter (Windows operating
system)
Youcanndfurtherinformationintheoperatinginstructions"Display
and adjustment module PLICSCOM"(Document-ID27835).
Packaging
Transport
Transport inspection
Storage
Storage and transport
temperature
Lifting and carrying
PLICSCOM
1)
Bluetooth function with VEGADIS 82 can only be used at a later date.
12
3 Product description
VEGACAL 69 • 4 … 20 mA/HART - two-wire
31178-EN-170503
The interface adapter VEGACONNECT enables the connection of
communication-capable instruments to the USB interface of a PC. For
parameter adjustment of these instruments, the adjustment software
PACTwarewithVEGA-DTMisrequired.
Youcanndfurtherinformationintheoperatinginstructions"Interface
adapter VEGACONNECT"(Document-ID32628).
VEGADIS 82 is suitable for measured value indication and adjustment
of sensors with HART protocol. It is looped into the 4 … 20 mA/HART
signal cable.
Youcanndfurtherinformationintheoperatinginstructions
"VEGADIS 82 4 … 20 mA/HART"(Document-ID45300).
The protective cover protects the sensor housing against soiling and
intense heat from solar radiation.
Youwillndadditionalinformationinthesupplementaryinstructions
manual"Protective cover"(Document-ID34296).
Screwedangesareavailableindierentversionsaccordingtothe
followingstandards:DIN2501,EN1092-1,BS10,ASMEB16.5,
JISB2210-1984,GOST12821-80.
Youcanndadditionalinformationinthesupplementaryinstructions
manual"Flanges according to DIN-EN-ASME-JIS".
VEGACONNECT
VEGADIS 82
Protectiv
e cover
Flanges
13
4Mounting
VEGACAL 69 • 4 … 20 mA/HART - two-wire
31178-EN-170503
4 Mounting
4.1 General instructions
Makesurethatallpartsoftheinstrumentcomingindirectcontact
with the process, especially the sensor element, process seal and
processtting,aresuitablefortheexistingprocessconditions,such
as process pressure, process temperature as well as the chemical
properties of the medium.
Youcanndthespecicationsinchapter"Technical data"andonthe
nameplate.
The instrument is suitable for standard and extended ambient condi-
tions acc. to DIN/EN/IEC/ANSI/ISA/UL/CSA 61010-1.
Select an installation position you can easily reach for mounting and
connectingaswellaslaterretrottingofadisplayandadjustment
module. The housing can be rotated by 330° without the use of any
tools. You can also install the display and adjustment module in four
dierentpositions(eachdisplacedby90°).
Before beginning the welding work, remove the electronics module
from the sensor. By doing this, you avoid damage to the electronics
through inductive coupling.
Ground the probe before welding directly on the rod or cable.
Usetherecommendedcables(seechapter"Connecting to power
supply")andtightenthecablegland.
You can give your instrument additional protection against moisture
penetration by leading the connection cable downward in front of the
cableentry.Rainandcondensationwatercanthusdraino.Thisap-
plies mainly to outdoor mounting as well as installation in areas where
high humidity is expected (e.g. through cleaning processes) or on
cooled or heated vessels.
To maintain the housing protection, make sure that the housing lid is
closed during operation and locked, if necessary.
Makesurethatthedegreeofcontaminationspeciedinchapter
"Technicaldata"meetstheexistingambientconditions.
Fig. 4: Measures against moisture ingress
Suitability for the process
conditions
Suitability for the ambient
conditions
Installation position
Welding work
Moisture
14
4Mounting
VEGACAL 69 • 4 … 20 mA/HART - two-wire
31178-EN-170503
Theprocessttingmustbesealedifthereisgaugeorlowpressurein
the vessel. Before use, check if the seal material is resistant against
the measured product and the process temperature.
Themax.permissiblepressureisspeciedinchapter"Technical
data"oronthetypelabelofthesensor.
Metric threads
In the case of instrument housings with metric thread, the cable
glands are screwed in at the factory. They are sealed with plastic
plugs as transport protection.
You have to remove these plugs before electrical connection.
NPTthread
In the case of instrument housings with self-sealing NPT threads, it is
not possible to have the cable entries screwed in at the factory. The
free openings for the cable glands are therefore covered with red dust
protection caps as transport protection.
Prior to setup you have to replace these protective caps with ap-
proved cable glands or close the openings with suitable blind plugs.
4.2 Mounting instructions
Iftheinstrumentismountedinthellingstream,unwantedfalse
measurement signals can be generated. For this reason, mount the
instrument at a position in the vessel where no disturbances, e.g. from
llingopenings,agitators,etc.,canoccur.
This applies particularly to instrument versions with a longer probe.
Fig.5:Inowingmedium
Pressure/Vacuum
Cableentries-NPT
thread
Cable glands
Inowingmedium
15
5 Connecting to power supply
VEGACAL 69 • 4 … 20 mA/HART - two-wire
31178-EN-170503
5 Connecting to power supply
5.1 Preparing the connection
Always keep in mind the following safety instructions:
Warning:
Connect only in the complete absence of line voltage.
The electrical connection must only be carried out by trained
personnel authorised by the plant operator.
If overvoltage surges are expected, overvoltage arresters should
be installed.
Power supply and current signal are carried on the same two-wire
cable.Theoperatingvoltagecandierdependingontheinstrument
version.
Thedataforpowersupplyarespeciedinchapter"Technical data".
Provide a reliable separation between the supply circuit and the
mains circuits according to DIN EN 61140 VDE 0140-1.
Power the instrument via an energy-limited circuit acc. to DIN/EN/IEC/
ANSI/ISA/UL/CSA 61010-1, e.g. via Class 2 power supply unit acc. to
UL 1310 or an SELV power supply unit with suitable external current
limitation.
2)
Keepinmindthefollowingadditionalfactorsthatinuencetheoperat-
ing voltage:
Lower output voltage of the power supply unit under nominal load
(e.g. with a sensor current of 20.5 mA or 22 mA in case of fault)
Inuenceofadditionalinstrumentsinthecircuit(seeloadvaluesin
chapter"Technical data")
The instrument is connected with standard two-wire cable without
screen. If electromagnetic interference is expected which is above the
test values of EN 61326-1 for industrial areas, screened cable should
be used.
Makesurethatthecableusedhastherequiredtemperatureresist-
anceandresafetyformax.occurringambienttemperature
Use cable with round cross section for instruments with housing and
cablegland.Toensurethesealeectofthecablegland(IPprotection
rating),ndoutwhichcableouterdiameterthecableglandissuitable
for.
Useacableglandttingthecablediameter.
We generally recommend the use of screened cable for HART
multidrop mode.
Safety instructions
Voltage supply
Connection cable
2)
Class 2 power supply unit: limited voltage and power level, special insulation
against circuits with higher voltage. SELV (Safety Extra Low Voltage) power
supply unit: limited voltage level, special insulation against circuits with
higher voltage
16
5 Connecting to power supply
VEGACAL 69 • 4 … 20 mA/HART - two-wire
31178-EN-170503
Metric threads
In the case of instrument housings with metric thread, the cable
glands are screwed in at the factory. They are sealed with plastic
plugs as transport protection.
You have to remove these plugs before electrical connection.
NPTthread
In the case of instrument housings with self-sealing NPT threads, it is
not possible to have the cable entries screwed in at the factory. The
free openings for the cable glands are therefore covered with red dust
protection caps as transport protection.
Prior to setup you have to replace these protective caps with ap-
proved cable glands or close the openings with suitable blind plugs.
On plastic housings, the NPT cable gland or the Conduit steel tube
must be screwed into the threaded insert without grease.
If screened cable is required, we recommend connecting the cable
screen on both ends to ground potential. In the sensor, the screen
must be connected directly to the internal ground terminal. The
ground terminal on the outside of the housing must be connected to
the ground potential (low impedance).
In Ex systems, the grounding is carried out according to the installa-
tion regulations.
In electroplating plants as well as plants that apply cathodic corro-
sionprotection,itmustbetakenintoaccountthatsignicantpotential
dierencesexist.Thiscanleadtounacceptablyhighcurrentsinthe
cable screen if it is grounded at both ends.
Information:
Themetallicpartsoftheinstrument(processtting,housing,etc.)are
conductively connected to the ground terminal.
Take note of the corresponding installation regulations for Ex applica-
tions. In particular, make sure that no potential equalisation currents
owoverthecablescreen.Incaseofgroundingonbothsidesthis
can be achieved by the use of a capacitor or a separate potential
equalisation.
5.2 Connection procedure
Proceed as follows:
1. Unscrew the housing lid
2. If a display and adjustment module is installed, remove it by turn-
ing it to the left.
3. Loosen compression nut of the cable gland and remove blind
plug
4. Remove approx. 10 cm (4 in) of the cable mantle, strip approx.
1 cm (0.4 in) of insulation from the ends of the individual wires
5. Insert the cable into the sensor through the cable entry
Cable glands
Cable screening and
grounding
17
5 Connecting to power supply
VEGACAL 69 • 4 … 20 mA/HART - two-wire
31178-EN-170503
6. Lift the opening levers of the terminals with a screwdriver (see
following illustration)
7. Insert the wire ends into the open terminals according to the wir-
ing plan
Fig. 6: Connection steps 6 and 7
8. Press down the opening levers of the terminals, you will hear the
terminal spring closing
9. Check the hold of the wires in the terminals by lightly pulling on
them
10. Connect the screen to the internal ground terminal, connect the
external ground terminal to potential equalisation
11. Tighten the compression nut of the cable entry gland. The seal
ring must completely encircle the cable
12. Screw the housing lid back on
Theelectricalconnectionisnished.
5.3 Wiring plan, single chamber housing
The following illustrations apply to the non-Ex as well as to the Ex-ia
version.
18
5 Connecting to power supply
VEGACAL 69 • 4 … 20 mA/HART - two-wire
31178-EN-170503
5
5
5
5
1 2
4
3
Fig. 7: Material versions, single chamber housing
1 Plastic
2 Aluminium
3 Stainless steel (precision casting)
4 Stainless steel (electro-polished)
5 Filter element for air pressure compensation of all material versions. Blind
plug with version IP 66/IP 68, 1 bar for Aluminium and stainless steel
I
²
C
Display
12 5678
3
4
1
2
Fig. 8: Electronics and terminal compartment - single chamber housing
1 Plug connector for VEGACONNECT (I²C interface)
2 Spring-loaded terminals for connection of the external indication VEGADIS
61
3 Ground terminal for connection of the cable screen
4 Spring-loaded terminals for voltage supply
Housing overview
Electronics and terminal
compartment
19
5 Connecting to power supply
VEGACAL 69 • 4 … 20 mA/HART - two-wire
31178-EN-170503
I
2
C
Display
1
12 5 678
Fig. 9: Wiring plan - single chamber housing
1 Voltage supply, signal output
5.4 Wiring plan, double chamber housing
The following illustrations apply to the non-Ex as well as to the Ex-ia
version.
1 2 3
4
5
Fig. 10: Double chamber housing
1 Housing cover - connection compartment
2 Blind plug or plug M12 x 1 for VEGADIS 61 (optional)
3 Housing cover - electronics compartment
4 Filter element for air pressure compensation
5 Cable gland
Wiring plan
Housing overview
20
5 Connecting to power supply
VEGACAL 69 • 4 … 20 mA/HART - two-wire
31178-EN-170503
1
3
2
Display
12 5678
I
²
C
Fig. 11: Electronics compartment - double chamber housing
1 Plug connector for VEGACONNECT (I²C interface)
2 Internal connection cable to the connection compartment
3 Terminals for VEGADIS 81
1
2
3
Display
12
I
2
C
Fig. 12: Terminal compartment - double chamber housing
1 Spring-loaded terminals for voltage supply
2 Plug connector for VEGACONNECT (I²C interface)
3 Ground terminal for connection of the cable screen
Electronics compartment
Terminal compartment
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56

Vega VEGACAL 69 Operating instructions

Category
Measuring, testing & control
Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI