Co2meter 006-0-0008 Senseair Sunrise HVAC CO2 Sensor User manual

  • Hello! I have reviewed the Handling Manual for Senseair Sunrise and Sunlight CO2 sensor modules. This document provides important information about proper handling, installation procedures, and maintenance of these sensors, including the need for ESD protection, specific soldering guidelines, and ensuring correct airflow. Please feel free to ask me any questions you have about these sensor modules.
  • How should I handle the sensor?
    What precautions should I take while soldering?
    What should I consider about the particle filter?
Document Rev Page
ANO4947 9 1 (2)
NOTE:
ESD sensitive product.
Use ESD protection equipment.
NOTE:
To ensure airow, and quick sensor response time to changes
in environment: do not block particle lter!
Handling Manual
Senseair Sunrise and Sunlight
Miniature CO2 sensor module with NDIR technique
Installation and soldering
See IPC-J-STD-001 for acceptable soldering conditions in general.
Selective soldering machine (drag soldering method): soldering temperature 295 °C / 563 °F during three seconds.
Hand soldering: soldering iron temperature 380 °C / 716 °F during two seconds / pin.
To eliminate the risk to damage the OBA (Optical Bench Assembly), soldering on the bottom side is recommended.
Mechanical properties
Please refer to mechanical drawing for detailed specication of dimensions and tolerances.
Layout considerations
Use cut-outs or slits in main board to reduce mechanical stress to sensor due to board thermal expansion.
NOTE:
Handle sensor by holding PCB only.
Never touch sensor with bare hands! Use clean gloves
to avoid dust, grease or other contaminations.
Sensor shall not be subjected to any force.
Particle lter
Document Rev Page
ANO4947 9 2 (2)
©2023 Senseair AB. All rights reserved.
Storage
Storage in sealed ESD bags.
Storage temperature: According to specification.
Requirements on storage environment: In normal IAQ environments corrosive environments are excluded.
Inspection - verication
Transport, handling and assembly may affect calibration. Accuracy is dened after minimum three ABC (Automatic
Baseline Correction) periods of continuous operation with ABC in normal IAQ applications. Different options exist
and can be customised depending on the application. Please, contact Senseair for further information!
Preferably, please inspect and perform zero calibration after any, or all, transports.
NOTE:
No gluing or potting on sensor.
NOTE:
1.0mm ≤ minimum distance
from sensor to cover / PCB.
1.0 ≤
[mm]
1.0 ≤
1.5 ≤
NOTE:
1.0mm ≤ minimum distance
from sensor to cover / PCB.
[mm]
[mm]
NOTE:
1.5mm ≤ minimum distance
from particle filter to cover / PCB.
/