Below you will find brief product information for Panasonic TY42TM4Z. This device is a RCA Terminal Board that must only be installed in the TH-42PW4, TH-42PWD4 models. It allows to display AV input and component input signals using RCA input Terminals. The device should only be installed by a qualified service engineer that will insert it in the terminal slot at the rear of the Plasma Display. Before the installation make sure to turn off the power switch, pull out the plug and disconnect any plugs connected to the Plasma Display.

Panasonic TY42TM4Z

Below you will find brief product information for Panasonic TY42TM4Z. This device is a RCA Terminal Board that must only be installed in the TH-42PW4, TH-42PWD4 models. It allows to display AV input and component input signals using RCA input Terminals. The device should only be installed by a qualified service engineer that will insert it in the terminal slot at the rear of the Plasma Display. Before the installation make sure to turn off the power switch, pull out the plug and disconnect any plugs connected to the Plasma Display.

RCA Terminal Board Installation Manual
Installationsanleitung für das RCA-Terminal-Board
Manuel d'installation de la carte de connexion RCA
Manuale d’installazione della scheda di terminali RCA
Manual de instalación del tablero de terminales RCA
Installatiehandleiding voor de RCA aansluitingenkaart
Installationsvejledning for RCA terminalkort
Installationsmanual för RCA uttagsplatta
RCA Terminal Board
Model No.
TY-42TM4Z
Svenska Dansk
EnglishDeutschFrançais
ItalianoEspañol
Nederlands
TQBC0284
®
2
Users should not attempt to install or remove this product.
Only a qualified service engineer should perform installation.
Install this Terminal Board in the specified products only.
This product is a RCA Terminal Board, and must only be installed in the TH-42PW4, TH-42PWD4
models.
This should only be installed in the specified Plasma Display.
Failure to observe this point may result in damage to the projector and may further cause the
installed product to malfunction.
Do not touch the product directly.
Highly sensitive electronic components are fitted in high density.
Touching components or the board directly while installing may cause the product to
malfunction.(During installation, ensure static electricity is discharged to earth by suitable means.)
Always pull out the power cables from the AC socket before commencing installation.
Do not drop the product or allow any action that may cause damage to it.
Do not place this product in water or allow it to become wet.
Do not attempt to modify this product in any way.
WARNING :
P
R
/C
R
/R
P
B
/C
B
/B Y/G
COMPONENT/RGB INAV IN
VD
HD
S VIDEOVIDEO
RL
AUDIO
RL
AUDIO
This Terminal Board is the following arrangement
RCA Terminal Board Installation manual
After installing this product in the Plasma Display (TH-42PW4 series), AV input and component input signals can be
displayed using RCA input Terminals.
Please confirm the model number of your
Plasma Display
model number
R - STANDBY
G POWER ON
INPUT
VOL
+
R - STANDBY
G POWER ON
TH-42PW4
English
3
Affixing the Terminal name indication label
Terminal name
indication label
Rear of Plasma Display
Affixing location
After completing installation of the Terminal Board, affix the included Terminal name indication label to the Plasma
Display.
To affix the label:
Peel off the rear protective sheet of the Terminal name
indication label.
For Plasma Display models to which a label is already
affixed, position the Terminal name indication label on
top of that label.
For models to which a label is not yet attached, affix the
Terminal name indication label while aligning with the molded
label locating marks, as shown in the figure.
For some models of the Plasma
Display, a label is already affixed.
Install the Terminal Board in the terminal slot at the rear of the Plasma Display.
Before installation
Turn the power switch off and pull out the plug.
Disconnect any plugs connected to the Plasma Display.
1
Place the Plasma Display upside down on a soft sur-
face, such as a foam mat.
4
Secure using the 4 screws removed at step 2 above.
Tighten screws in the numbered order ( ).
2
Remove the 4 screws securing the slot cover or a
currently installed terminal board and remove the
cover or terminal board.
Note : The 4 screws are required for reassembly so
should be retained.
3
Confirm that the Terminal Board is correctly orientated
then carefully and slowly insert into the slot.
Ensure that the Board is completely seated.
Foam mat or thick
soft cloth
Note : Retain the cover or terminal board that has been removed in a safe location for potential future use.
Terminal name
indication label
Terminal name
indication label
Install
English
Molded marks for label location
Molded marks
Molded marks
Matsushita Electric Industrial Co., Ltd.
Web site : http://www.panasonic.co.jp/global/
Printed in Japan
MBS0701S0(MS)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

Panasonic TY42TM4Z Operating instructions

Type
Operating instructions

Panasonic TY42TM4Z

Below you will find brief product information for Panasonic TY42TM4Z. This device is a RCA Terminal Board that must only be installed in the TH-42PW4, TH-42PWD4 models. It allows to display AV input and component input signals using RCA input Terminals. The device should only be installed by a qualified service engineer that will insert it in the terminal slot at the rear of the Plasma Display. Before the installation make sure to turn off the power switch, pull out the plug and disconnect any plugs connected to the Plasma Display.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI