Bradley Frequency FL-2H Installation guide

Category
Sanitary ware
Type
Installation guide

This manual is also suitable for

P.O. Box 309, Menomonee Falls, WI USA 53052-0309
PHONE 800.BRADLEY (800.272.3539) FAX 262.251.5817
bradleycorp.com
Installation
215-1512 Rev. G; ECM 11-08-011
© 2012 Bradley Corporation
Page 1 of 34 2/15/2012
FL-2H, FL-2L
Frequency
®
Lavatory System
Système de lavabos Frequency
®
Sistema de lavabo Frequency
®
U.S. Pat. No. Des. 477,060
507,634
527,809
537,927
7,039,963
Table of Contents
Pre-Installation Information ..............................2
Components .........................................3
Dimensions ........................................4–5
Rough-ins for FL-2H ...................................6
Rough-ins for FL-2L ....................................7
Lavatory Deck Mounting ................................8
Drain and P-Traps .....................................9
Faucet Battery Box ...................................10
Optional Tankless Water Heater .........................10
End Outlet and Continuous Waste .......................11
Adjust Temperature with Water Running ...................11
Optional Trap/Transition Covers .........................12
Cleaning and Maintenance Instructions ...................12
Table des matières
Avant l’installation ....................................13
Composants ........................................14
Dimensions ......................................15–16
Mises en place des canalisations pour FL-2H ............... 17
Mises en place des canalisations pour FL-2L ...............18
Lavabo .............................................19
Drain et siphon en P ..................................20
Compartiment des piles de robinets ......................21
Chauffage d’eau sans réservoir en option ..................21
Sortie en bout et évacuation continue .....................22
Faire couler l'eau pour régler la température ................22
Siphon/Couvercles de transition en option .................23
Instructions de nettoyage et d’entretien pour Terreon .........23
Contenido
Información previa a la instalación .......................24
Componentes de la cubierta del lavabo ...................25
Dimensiones .....................................26–27
Colocación de tuberías empotradas del FL-2H ..............28
Colocación de tuberías empotradas del FL-2L ..............29
Montaje de la cubierta del lavabo ........................30
Desagüe y sifón en P .................................31
Caja de batería de la llave ..............................32
Calentador de agua sin tanque opcional ...................32
Salida del extremo y desechos continuos ..................33
Ajuste la temperatura con el agua corriendo ................ 33
Sifón/Cubiertas de transición opcionales ..................34
Instrucciones de limpieza y mantenimiento para Terreon ......34
FL-2H
FL-2L
FL-2H, FL-2L Installation
2 2/15/2012 Bradley Corporation • 215-1512 Rev. G; ECM 11-08-011
IMPORTANT!
Read this entire installation manual to ensure proper installation.
When finished with the installation, file this manual with the owner or
maintenance department. Compliance and conformity to local codes
and ordinances is the responsibility of the installers.
Separate parts from packaging and make sure all parts are accounted
for before discarding any packaging material. If any parts are
missing, do not begin installation until you obtain the missing parts.
Make sure that all water supply lines have been flushed and then
completely turned off before beginning installation. Debris in supply
lines can cause valves to malfunction.
Turn OFF electrical power to the electrical outlets, then unplug all
electrical units prior to installation. Electrical power MUST remain off
until installation is complete. After installation is complete, turn on
the water supply first, then turn on the electrical power.
Hardware provided by installer must be appropriate for wall
construction. Wall anchors must have a minimum pull-out rating of
1,000 lbs.
Product warranties may be found under “Products” on our Web site
at bradleycorp.com.
THIS
SIDE
UP
Packing List
Installation
Supplies Required:
• (6)3/8"wallanchors,boltsand1"min.O.D.washerstomountmainframeandbowltowall(minimumpull-outratingof
1,000 lbs.)
• (2)#10wallanchors(foroptionalmixingvalve/bracketmounting)
• 1/2"Nominalcoppertubingforhot/coldortemperedsupplypiping
• 1-1/2"NPTdrainpiping
• OPTIONAL:110voltGFCIprotectedelectricaloutletfor100–120VACplug-intransformer(forBradleyFaucets)
• OPTIONAL:240/208or277voltsforelectrictanklesswaterheater
Installation FL-2H, FL-2L
Bradley Corporation • 215-1512 Rev. G; ECM 11-08-011 2/15/2012 3
Components
Prepack Trap Cover FL-2
(S45-2109 - Gray)
(S45-2109A - Putty)
(S45-2109B - Coal)
FL-2H (187-269)
(contact Bradley for color options)
FL-2L (187-270)
(contact Bradley for color options)
Transition Cover
(186-1459 - Gray)
(186-1459A - Putty)
(186-1459B - Coal)
Soap Dispenser
Model 6334
Support Bracket - Left
(140-823L)
Support Bracket - Right
(140-823R)
#10 Washer
(142-002AT)
#10-24 Screw
(P18-054)
Standard Waste
Assembly
Offset Strainer
(269-1751)
Offset Strainer
(269-1751)
End Outlet 1-½"
(269-1743)
P-Trap
(269-1697)
Optional
Single-Unit
Adapter
(153-443)
Aerada™ 1200 Series
CS Faucet
Model S53-315
Optional Tankless Water Heater
(269-1767 - EX95TMLB, 240/208 volts)
(269-1768 - EX100TMLB, 277 volts)
Navigator
®
TMV Assembly
Bracket
(140-1041)
Screw
160-447
Valve
(S01-526)
Optional
Tempered Line
½" Flexible Hose
(269-2053)
Stop Valve
(S27-340)
FL-2H, FL-2L Installation
4 2/15/2012 Bradley Corporation • 215-1512 Rev. G; ECM 11-08-011
Dimensions - Front and Top Views
FL-2H shown
FL-2L is similar
FL-2H
FL-2L
60"
(1524mm)
30"
(762mm)
15"
(381mm)
7¾"
(197mm)
22"
(559mm)
30" (762mm) ADA
15" (381mm)
ADA
4"
(102mm)
34"
(864mm)
ADA
32"
(813mm)
12¼"
(311mm)
30"
(762mm)
36"
(914mm)
37¾"
(959mm)
30" (762mm) ADA
4"
(102mm)
15" (381mm)
ADA
34"
(864mm)
ADA
32"
(813mm)
12¼"
(311mm)
30"
(762mm)
36"
(914mm)
37¾"
(959mm)
Installation FL-2H, FL-2L
Bradley Corporation • 215-1512 Rev. G; ECM 11-08-011 2/15/2012 5
Dimensions - Side Views
TAS
TAS
22" (559mm)
19½" (495mm)
14"
(356mm)
37¾"
(959mm)
4½"
(114mm)
12¼"
(311mm)
30"
(762mm)
34"
(864mm)
Rim
Height
Standard
Height
22" (559mm)
19½" (495mm)
14"
(356mm)
34¾"
(883mm)
4½"
(114mm)
9¼"
(235mm)
27"
(686mm)
31"
(787mm)
Rim
Height
Juvenile
Height
Ages 6-12
22" (559mm)
19½" (495mm)
14"
(356mm)
33¾"
(857mm)
4½"
(114mm)
" (210mm)
26"
(660mm)
30"
(762mm)
Rim
Height
TAS Height
Grades Pre-K
through 5 or 6
22" (559mm)
19½" (495mm)
14"
(356mm)
33¾"
(857mm)
4½"
(114mm)
10¼" (260mm)
28"
(711mm)
32"
(813mm)
Rim
Height
TAS Height
Grades 6 through
8 or 9
FL-2H, FL-2L Installation
6 2/15/2012 Bradley Corporation • 215-1512 Rev. G; ECM 11-08-011
1a
Rough-Ins for FL-2H
Code Description Qty.
A
3
8"LavDeckAnchorswithaMinimumPull-OutForceof1,000lbs. 6
B #10WallAnchors/FastenersforMountingTrap/TransitionCovers 5
H, C ½"NominalCopperTubingforHot/ColdSupplies,Stub-Out2"FromWall 1
D #10WallAnchors/FastenersforValveMounting 2
E 110vGFIProtectedElectricalOutlet 1
W
1½"NPTDrain,stubout2"fromwall(forcombined drain)
NOTE: For individual drains, refer to page 9.
1
Rim Height
Vertical Height Adjustments for codes A–E,
H, C and W
Fixture Style
34" 0 Standard Height
32" Subtract2" TAS,Grades6through8or9
31" Subtract3" TAS,Pre-KthroughGrades5or6
30" Subtract4" Juvenile Height
27
7
8"
(708mm)
27
7
8"
(708mm) 7"
(178mm)
26"
(660mm)
2
1
8" (54mm)
2
1
8" (54mm)
26"
(660mm)
½"
(13mm)
33"
(838mm)
30"
(762mm)
24"
(610mm)
26
3
8"
(670mm)
1
3
8"
(35mm)
17"
(432mm)
4"
(102mm)
20"
(508mm)
10"
(254mm)
Tempered Line
A
A
A
A
A
A
B
B
B
B
B
D
D
H
C
E
W
Recommended 2240v/208v or 277v Electrical
Rough-In Location (approx. 6" x 6")
15¾"
(400mm)
25"
(635mm)
29"
(737mm)
32"
(813mm)
28"
(711mm)
31"
(787mm)
Installation FL-2H, FL-2L
Bradley Corporation • 215-1512 Rev. G; ECM 11-08-011 2/15/2012 7
1b
Rough-Ins for FL-2L
Rim Height
Vertical Height Adjustments for codes A–E,
H, C and W
Fixture Style
34" 0 Standard Height
32" Subtract2" TAS,Grades6through8or9
31" Subtract3" TAS,Pre-KthroughGrades5or6
30" Subtract4" Juvenile Height
Code Description Qty.
A
3
8"LavDeckAnchorswithaMinimumPull-OutForceof1,000lbs. 6
B #10WallAnchors/FastenersforMountingTrap/TransitionCovers 5
H, C ½"NominalCopperTubingforHot/ColdSupplies,Stub-Out2"FromWall 1
D #10WallAnchors/FastenersforValveMounting 2
E 110vGFIProtectedElectricalOutlet 1
W
1½"NPTDrain,stubout2"fromwall(forcombined drain)
NOTE: For individual drains, refer to page 9.
1
27
7
8"
(708mm)
27
7
8"
(708mm)
7"
(178mm)
26"
(660mm)
26"
(660mm)
2
1
8" (54mm)
2
1
8" (54mm)
½" (13mm)
31"
(787mm)
28"
(711mm)
24"
(610mm)
26
3
8"
(670mm)
1
3
8"
(35mm)
17"
(432mm)
4"
(102mm)
15¾"
(400mm)
10"
(254mm)
Tempered Line
20"
(508mm)
Recommended 2240v/208v or 277v Electrical
Rough-In Location (approx. 6" x 6")
29"
(737mm)
25"
(635mm)
32"
(813mm)
30"
(762mm)
33"
(838mm)
A
A
A
A
A
A
B
B
B
B
B
D
D
H
C
E
W
FL-2H, FL-2L Installation
8 2/15/2012 Bradley Corporation • 215-1512 Rev. G; ECM 11-08-011
2
Lavatory Deck
Backing Information
16"
(406mm)
Metal Studs
Drywall
66"
(1676mm)
12"
(305mm)
25"
(635mm)
Securely fasten
plywood to at
least (3) metal
studs (plywood
to equal thickness
of drywall, ½"
minimum
Use
3
8"
toggle bolts
and washers to
secure the support
bracket to plywood
(2) places.
Refer to the rough-ins to determine wall-mounting location for
optional mixing valve.
Installer may prefer to install the faucet before mounting the
fixture to the wall.
If necessary, adjust the fixture height
before securing to the support brackets.
Installation FL-2H, FL-2L
Bradley Corporation • 215-1512 Rev. G; ECM 11-08-011 2/15/2012 9
3a
Drain and P-Trap
FL-2L shown
FL-2H is opposite
3b
Individual P-Traps
Rubber
Friction
Nut
Tailpiece
5"
(127mm)
Rubber
Friction
Tailpiece
Nut
1½"
(38mm)
Top View
Rotate
60°
Rotate
60°
30" (762mm) Ref.
NOTE: FL-2H: Remove 4" from right side tailpiece only.
FL-2L: Remove 4" from left side of tailpiece only.
1½" Drain
Stub Out 2" from
Wall (2) Places
20"
(508mm)
3½" Max.
(2) Places
FL-2H is shown; FL2L is similiar.
FL-2H, FL-2L Installation
10 2/15/2012 Bradley Corporation • 215-1512 Rev. G; ECM 11-08-011
4
Faucet Battery Box
5
Optional Tankless Water Heater
B
Install the faucets
according to the
manufacturer's
instructions.
A
Mount the Faucet
Battery Boxes to the
wall at desired locations.
Faucet Valve Control Module
½" Flexible Hose (qty. 3)
(269-653)
½" Tee
(269-1150)
Cold
Hot
Mixing Valve
¾"
(19mm)
Electric Tankless
Water Heater
Outlet
Inlet
20½"
(521mm)
Finished Floor
Installation FL-2H, FL-2L
Bradley Corporation • 215-1512 Rev. G; ECM 11-08-011 2/15/2012 11
6
End Outlet and Continuous Waste
FL-2L shown
FL-2H is opposite
TOP VIEW
FRONT VIEW
25" (508mm) REF.
7
Adjust Temperature with Water Running
H
C
A
LoosenCapScrewabout1/4"(4-6
turns) and lift up cover (do not
remove).
B
Using cover, turn cartridge gently until
desired water temperature is reached.
Do not turn past stops as this may
damage unit. Push cover down and
tighten screw.
This valve is NOT factory preset. Upon installation, the temperature of this
valve must be checked and adjusted to ensure delivery of a safe water
temperature. Water in excess of 110°F (43°C) may cause scalding.
FL-2H, FL-2L Installation
12 2/15/2012 Bradley Corporation • 215-1512 Rev. G; ECM 11-08-011
Cleaning and Maintenance for Terreon
Material Description: Terreon is an NAHB Certified densified solid surface material composed of polyester resin and is resistant
to chemicals, stains, burns and impact. Surface damage can be easily repaired with everyday cleansers or fine grit abrasives.
Routine Cleaning: Clean daily or as often as conditions require using a standard commercial or household cleaner such as
Formula 409
®
or Windex
®
.
Stubborn Stains: Remove tough stains with Ajax
®
, Comet
®
, or Soft-Scrub
®
and a green Scotch-Brite
®
pad or lightly sand in a
circular motion with 240 grit wet/dry sandpaper. The finish can be renewed with a maroon Scotch-Brite
®
pad.
Special Situations for Terreon Material
Scratches: Remove scratches with a green Scotch-Brite
®
pad. The finish can then be renewed with a maroon Scotch-Brite
®
pad, followed by a white Scotch-Brite
®
pad or 30-micron sandpaper.
Hard Water Deposits: Remove hard water deposits with a mild solution of vinegar and water. Always rinse the unit
thoroughly after cleaning.
Restoring the surface: Use Hope’s
®
Solid Surface cleaner and polish to refresh and protect the Terreon Solid Surface
material. Bradley recommends additional care and maintenance for the darker colored Terreon. For additional information,
visit bradleycorp.com.
Do not use strong acid or alkaline chemicals and cleansers to clean Terreon. If these chemicals come in
contact with the surface, wipe them off immediately and rinse with soapy water. Avoid contact with harsh
chemicals such as paint remover, bleach, acetone, etc. Avoid contact with hot pans and objects.
Repair Kits: Terreon repair kits are available. Contact your Bradley representative or distributor for part numbers and pricing
Repair kits are made to order and have a shelf life of 30 days.
Terreon is a unique, cast solid surface material. Aggregate flow and distribution as well as shades of color can vary from
product to product creating natural characteristics.
Brand Names: Use of brand names is intended only to indicate a type of cleaner. This does not constitute an endorsement,
nor does the omission of any brand name cleaner imply inadequacy. Many products named are regional in distribution, and
can be found in local supermarkets, department and hardware stores, or through your cleaning service. It is emphasized that
all products should be used in strict accordance with package instructions.
8
Optional Trap/Transition Covers
A
Turn on the water and test the unit
for leaks and proper operation.
B
Secure the transition cover through
the vertical slot with hardware
provided.
C
Trim the trap covers (at inside scoring only!)
with a high-speed rotary tool and 1/8 radius
tip bit (or very sharp knife). Clean burrs.
D
Position the trap covers
over the transition cover
and secure to the wall
with hardware provided.
DO NOT
TRIM!!!
DO NOT
TRIM!!!
Installation FL-2H, FL-2L
Bradley Corporation • 215-1512 Rev. G; ECM 11-08-011 2/15/2012 15
Dimensions - Vues de face et de dessus
FL-2H
FL-2L
FL-2H est montrée
FL-2L est similaire
60"
(1524mm)
30"
(762mm)
15"
(381mm)
7¾"
(197mm)
22"
(559mm)
30" (762mm) ADA
15" (381mm)
ADA
4"
(102mm)
34"
(864mm)
ADA
32"
(813mm)
12¼"
(311mm)
30"
(762mm)
36"
(914mm)
37¾"
(959mm)
30" (762mm) ADA
4"
(102mm)
15" (381mm)
ADA
34"
(864mm)
ADA
32"
(813mm)
12¼"
(311mm)
30"
(762mm)
36"
(914mm)
37¾"
(959mm)
FL-2H, FL-2L Installation
26 2/15/2012 Bradley Corporation • 215-1512 Rev. G; ECM 11-08-011
Dimensiones - Vista frontal y superior
FL-2H
FL-2L
FL-2H se muestra
FL-2L es similar
60"
(1524mm)
30"
(762mm)
15"
(381mm)
7¾"
(197mm)
22"
(559mm)
30" (762mm) ADA
15" (381mm)
ADA
4"
(102mm)
34"
(864mm)
ADA
32"
(813mm)
12¼"
(311mm)
30"
(762mm)
36"
(914mm)
37¾"
(959mm)
30" (762mm) ADA
4"
(102mm)
15" (381mm)
ADA
34"
(864mm)
ADA
32"
(813mm)
12¼"
(311mm)
30"
(762mm)
36"
(914mm)
37¾"
(959mm)
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34

Bradley Frequency FL-2H Installation guide

Category
Sanitary ware
Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI