ABB SR100B Quick Reference Manual

Type
Quick Reference Manual

ABB SR100B is an advanced and highly configurable paperless recorder, designed to provide accurate and reliable data acquisition and recording for a wide range of industrial applications. With its user-friendly interface and comprehensive set of features, the SR100B offers a versatile solution for monitoring and controlling various process parameters.

Key capabilities of the ABB SR100B include:

  • Analog Input Monitoring: Monitor up to 12 analog input channels with configurable ranges, scaling, and linearization options.
  • Relay Outputs: Control external devices or systems using up to 6 relay outputs, which can be configured for alarm or logic functions.

ABB SR100B is an advanced and highly configurable paperless recorder, designed to provide accurate and reliable data acquisition and recording for a wide range of industrial applications. With its user-friendly interface and comprehensive set of features, the SR100B offers a versatile solution for monitoring and controlling various process parameters.

Key capabilities of the ABB SR100B include:

  • Analog Input Monitoring: Monitor up to 12 analog input channels with configurable ranges, scaling, and linearization options.
  • Relay Outputs: Control external devices or systems using up to 6 relay outputs, which can be configured for alarm or logic functions.
Insert spindle
into new chart
Fit new chart
11
12
Withdraw cassette
Lift catch
7
8
50 mm
Tension chart with
thumbwheels
Unwind enough chart to fit over the
front and rear sprocket wheels
Feed chart under
retaining bar
Refit cassette
to instrument
13
14
15
16
Withdraw spindle
Remove old chart
9
10
SECURITY ACCESS
ENTER CODE 0
LOAD CHART
PAGE
OPERATING PAGES
(Channel displays, date/time)
OPERATING PAGES
(Channel displays, date/time)
TO START RELOAD
PRESS ENTER
REWINDING XXX%
(STOP ) (PAUSE )
REWOUND (MORE )
LOAD NEW ABB CHART
or
1
2 3
4
5
6
17
18
SR100B – Quick Reference Guide
Welcome to the SR100B
This quick reference guide contains loading procedures for roll
and fanfold charts, an overview of display/key functions and a
basic index for the SR100B User Guide.
Full installation, operating and programming procedures
together with a comprehensive index are provided in the User
Guide.
LOADING A NEW ROLL CHART
Accessories 1
Alarms
Acknowledging 13, 23
Configuring 22
Hysteresis 22
Message Printing 25
Operator Page Messages 12
Process 13, 22
Source 22
Status 13
Trip Level 22
Type 22
Analog Inputs
Channel Tag 9, 11, 18
Conditioning 19
Configuration 16 to 19
Connections 34, 35
Copying 19
Fault Detection 18
Isolation 35
Linearizer Type 17
Links 37
Offset Adjustment 21
Range 17, 18
Scaling 20
Span Adjustment 21
Type 17, 37
Chart
Configuration 24
Easy View 12, 26
Length 11, 26
Loading 4 to 7
Printout 9
Rewind 4
Set Length 26
Speed 4, 6, 9, 11, 24, 25
Time Line 4, 6, 26
Type Select 25
Configuration
Alarms 22
Analog Inputs 16
Chart 24
Relay Outputs 29
Connections 34 to 37
Date/time 11
Dimensions 31
Easy View 26
Electrical Connections 34
Error Messages 12
Fault-finding 38
Inputs
– see Analog Inputs
Language Selection 30
Links 37
Mounting 32
Operator Messages 12
Operating Page 10, 11
Paper Length 11, 26
Passwords 14, 15
Pen
Fitting 8
Lift 26
Print Speed 25
Real-time Clock 30
Relay Outputs
Connections 36, 37
Security Access
see Passwords
Siting 31
Software Version 14
Spares 39
Start-up Displays 10
Text Printing 25
Thermocouple 17
Time Line Advance 4, 6, 26
1
Press until the SECURITY ACCESS page is displayed.
2
Enter the access code for the LOAD CHART page (the default is 0).
3
Select the LOAD CHART page.
4
Press to select the START RELOAD frame.
5
Press to rewind the chart.
Caution.
The chart rewinds at high speed. DO NOT stop the chart until automatic rewind
is complete.
6
If the chart is fully rewound before the motor stops, press the key.
If the motor stops before the chart is fully rewound, press and hold until the remaining chart
has rewound onto the removeable spool.
17
Press to
resume recording.
18
Press until the
operating page is
re-displayed.
Caution. Once
chart loading is
complete, ensure the
correct chart type is
set in the
Chart Control
Configuration Page
see
Section 3.4.1
in
the
User Guide.
ABB has Sales & Customer
Support expertise in
over 100 countries
worldwide
www.abb.com
SECURITY ACCESS
ENTER CODE 0
LOAD CHART
PAGE
OPERATING PAGES
(Channel displays, date/time)
OPERATING PAGES
(Channel displays, date/time)
TO START RELOAD
PRESS ENTER
LOAD NEW ABB CHART
1
2
3
4
5
17
18
The Company's policy is one of continuous product
improvement and the right is reserved to modify the
information contained herein without notice.
© ABB 2003 Printed in UK (08.03)
Boiler 1 Temperature
A3 236.7 °C
Raise and Lower
Sideways Scroll
Down Scroll
Pen Lift
Enter
Channel
Identifier
Channel Tag
Measured
Value
Units
Used for adjusting parameters or
text messages.
Lifts and lowers the pen on
successive operations.
Used to confirm selections/
adjustments.
Frame 1
Page 1 Page 2
Advance to
next page
Frame 2
Advance to
next frame
Frame 1
Frame 2
Release
tension bar
Lift chart guide
Feed chart
through
cassette
Pull back
tension bar
Fit paper into
rear tray
Pull 6 or 7 folds of chart through the cassette
and fit chart into front paper tray
Align and fit chart over lugs
Close chart guide
Refit cassette to instrument
Withdraw cassette
Lift catch
6
7
8
9
10
11
12
13
14
15
16
15
IM/SR100B–Q Issue 1
DISPLAYS AND KEYS LOADING A NEW FAN-FOLD CHART
1
Press until the SECURITY ACCESS page is displayed.
2
Enter the access code for the LOAD CHART page (the default is 0).
3
Select the LOAD CHART page
4
Press to select the START RELOAD frame.
5
Press to stop recording.
Note. Channel data is not buffered during chart reloading.
Caution. Once
chart loading is
complete, ensure the
correct chart type is
set in the
Chart Control
Configuration Page
see
Section 3.4.1
in
the
User Guide.
17
Press to
resume recording.
18
Press until the
operating page is
re-displayed.
ABB Limited
Howard Road, St. Neots
Cambridgeshire, PE19 3EU
UK
Tel: +44 (0)1480 475 321
Fax: +44 (0)1480 217 948
ABB Inc.
125 E. County Line Road
Warminster, PA 18974
USA
Tel: +1 215-674-6000
Fax: +1 215-674-7183
  • Page 1 1
  • Page 2 2

ABB SR100B Quick Reference Manual

Type
Quick Reference Manual

ABB SR100B is an advanced and highly configurable paperless recorder, designed to provide accurate and reliable data acquisition and recording for a wide range of industrial applications. With its user-friendly interface and comprehensive set of features, the SR100B offers a versatile solution for monitoring and controlling various process parameters.

Key capabilities of the ABB SR100B include:

  • Analog Input Monitoring: Monitor up to 12 analog input channels with configurable ranges, scaling, and linearization options.
  • Relay Outputs: Control external devices or systems using up to 6 relay outputs, which can be configured for alarm or logic functions.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI