Amperes DP2406 User manual

Category
Musical Equipment
Type
User manual
INSTRUCTION MANUAL
Thank you for choosing another quality product from Amperes Electronics.
DP2000 Series are the new models of amplifiers which had been further refined to meet the market demands. DP2406 is
a quad channel version with 60W 100V output per channel whereas DP2212 shall be dual channel with output capacity of
120W 100V per channel.
Class D power engine is the core driver of the DP2000 series, which has various advantages over conventional circuitries,
among them are the higher amplification efficiency thus emitting lesser heat and current draw, flatter frequency response
and able to withstand higher operating temperature while maintaining its amplification characteristics.
It is most suitable for application in Matrix paging setup, where multiple channels of amplifiers are required. In system
which has small load for each channel, DP2000 amplifiers shall be the right choice as the unit count shall be greatly
reduced, which translates into rack space savings.
DP2406
4 CH 60W 100V Multi Channel Amplier
Ver 1 / 2014
Parts Identifications
Rear View DP2406
Front View DP2406
1
2
3
4
5
6
7
9
10
11
12
1. CHANNEL 1, 2, 3 & 4 INDICATION LEDs
Mains LED for incoming mains supply & protect LED is to indicate if the unit is switched to protection mode. Clip
LED shall lit if the incoming signal is too high whereas others to indicate signal level in two level i.e. -40 dB &
-10 dB.
2. MAINS SWITCH
For switching mains ac supply and the corresponding LED shall lit accordingly. Mains LED shall not lit if the back
up DC supply is available.
3. MAINS AC CORD
Mains AC cord comes with standard British 3 pin plug with fuse rating of 5A.
4. DC 24V INPUT
The unit operates on 24V DC. It is preferred that the unit to be supplied directly from the uninterrupted power
source. ie: Back up batteries. Alternatively, connect it to regulated power supply unit which is in turned has back
up supply.
5. SPEAKER OUTPUT TERMINAL ( CHANNEL 1, 2, 3 & 4 )
Outgoing terminals to speakers available in 4 Ohm, 70 and 100V line for usage with transformer coupled
speakers. The total speakers combined should have impedance higher than stated in the corresponding output
terminals to avoid overloading.
Loudspeakers with suitable matching transformer can be connected to the 30 or 70 or 100V line outputs in
parallel. However the total load should not exceed the nominal power output rating of the amplifier.
Do not parallel two power amplifiers in order to gain higher power rating as this may cause overloading in the
event that any one of them failed.
13
14
15
16
PAGE 2
AMPERES DP2406 MULTICHANNEL POWER AMPLIFIER
8
6. VENT FAN
11. RESET BUTTON (CHANNEL 1 and 3)
12. INPUT JACKS (CHANNEL 1)
The vent fan draws internally generated hot air & dispersed by the fan. The fan operates continuously with low
speed. To allow proper cooling, please ensure that the ambient is properly ventilated.
Parts Identifications
Button for resetting the unit, when amplifier is overloaded or overheat protection cut off is activated. The buffering
is for 2 channels.
Incoming signal to the unit is via 3 pin XLR female socket & the adjacent male jacks is for parallel linkage to the
next unit.
9. INPUT JACKS (CHANNEL 2)
Incoming signal to the unit is via 3 pin XLR female socket and the adjacent male jack is for parallel linkage to the
next unit.
7. VOLUME KNOB (CHANNEL 2)
Output volume is adjustable from -15 dB to 0 dB
10. VOLUME KNOB (CHANNEL 1)
Output volume is adjustable from -15 dB to 0 dB
8. RESET BUTTON (CHANNEL 2 and 4)
16. INPUT JACKS (CHANNEL 3)
Incoming signal to the unit is via 3 pin XLR female socket & the adjacent male jacks is connected parallel for
linkage to the next unit.
14. INPUT JACKS (CHANNEL 4)
Incoming signal to the unit is via 3 pin XLR female socket and the adjacent male jack is for parallel linkage to the
next unit.
13. VOLUME KNOB (CHANNEL 4)
Output volume is adjustable from -15 dB to 0 dB
15. VOLUME KNOB (CHANNEL 3)
Output volume is adjustable from -15 dB to 0 dB
AMPERES DP2406 MULTICHANNEL POWER AMPLIFIER
PAGE 3
Button for resetting the unit, when amplifier is overloaded or overheat protection cut off is activated. The buffering
is for 2 channels.
MxP 2188
MULTIPLE INPUT SOURCES
MxP2188
DP2406
SPEAKER
Unit Installation
Application Schematic
HOT AIR
COOL AIR
COOL AIR
Rear View DP2406
DP 2406
3 4
PUBLIC ADDRESS POWER AMPLIFIER 2 x 120W POWER AMPLIFIER
CH 1
CH 1
CH 2
CH 2
CH 3
CH 3
CH 4
CH 4
PAGE 4
AMPERES DP2406 MULTICHANNEL POWER AMPLIFIER
The above diagram depicts the air flow pattern for amplifier cooling system. Cool air is pulled from the side vent holes and
warm air shall be dissipated via the continous rotating fan.
Please ensure these vent holes are not blocked in order to keep the operating temperature at optimum. Allow a breathing
space of 100 mm for each vent outlet.
For installation in rack, we recommend that internal rack ventilation fans are installed, one for cool air intake and the other
for heat dissipation.
The optimum operating temperature of the unit shall be kept at approximately 40 degree Celsius.
Application example using one duty amplifier with one standby unit connecting to two zones of speakers.
System Connections - Normal Applications
CD1001
EP1200A
MX2222
..
AC 230V 50/60HZ
+
DC 24V
5
TIME OUT 5 MIN
LINE / MIC OUTPUT
MASTER / SLAVE
0 L S
M
M
TD6080
SPEAKERS
ZONE OUTPUT
--------
ZONE 1
ZONE 8
DA2208
PD1240
DP2406
DP2406
}
}
AMPERES DP2406 MULTICHANNEL POWER AMPLIFIER
PAGE 5
MONO VIA RCA JACK
BALANCED AUDIO OUT
CAT5E
AUDIO + DATA
100V LINE OUT
Application with Amperes AX3700 as auto amplifier changeover unit. ( 24V DC power supply connections and
incoming 240V ac mains not shown. )
DP2406
System Connections - With Auto Fault Changeover
MP1020 DUAL CHANNEL MEDIA PLAYER
MP1020 DUAL CHANNEL MEDIA PLAYER
MxP2188
AX3700
PAGE 6
AMPERES DP2406 MULTICHANNEL POWER AMPLIFIER
AUX OUTPUT
CH. 2 CH. 1
LINE INPUT
CH. 2 CH. 1
OFF/ON
LEFT
RIGHT
2 CH DIGITAL MEDIA PLAYER
ANTENNA
MP1020
AUX OUTPUT
CH. 2 CH. 1
LINE INPUT
CH. 2 CH. 1
OFF/ON
LEFT
RIGHT
2 CH DIGITAL MEDIA PLAYER
ANTENNA
MP1020
BG M 2
DC 24V
0.5 A
+
-
IN-
IN+
OUT+
I
N-
IN+
OUT+
OUT-
OUT-
IN-
IN+
OUT+
IN -
I
N
+
OUT +
OUT
-
O
UT-
I
N-
IN+
OUT+
IN-
IN+
O
U
T+
OUT-
OUT-
IN+
IN-
CHANNEL 1CHANNEL 2
CHANNEL 3CHANNEL 4
CHANNEL 5CHANNEL 6
STANDBY
AMP
CHAN. 1
ON
CHAN. 2
ON
CHAN. 3
ON
CHAN. 4
ON
CHAN. 5
ON
CHAN. 6
ON
HIG
H
CASCADE
LO
W
CHANNEL 6
+ - G + -
INPUT
OUTPUT
CHANNEL 5
+ - G + -
OUTPUT
INPUT
CHANNEL 4
+ - G + -
OUTPUT
INPUT
CHANNEL 3
+ - G + -
OUTPUT
INPUT
CHANNEL 2
+ - G + -
OUTPUT
INPUT
CHANNEL 1 STANDBY
+ - G + -
+
- G
OUTPUT
INPUT
OUTPUT
OPENLINK
LINK
SIGNAL
OPENLINK
LINK
SIGNAL
OPENLINK
LINK
SIGNAL
OPENLINK
LINK
SIGNAL
OPENLINK
LINK
SIGNAL
AX3700
PLEASE OBSERVE POLARITY
OUT +/- --> TO ZONE SELECTOR / SPEAKERS
AMP CONNECTIONS
IN +/- --> FR. AMP OUTPUTS
MAX LOAD / CH - 400W / 100V LINE
AMP. AUTO
FAULT
CHANGE OVER
AMPLIFIER 70/100V LINE INPUTS/OUTPUTS CHANNEL / AMP. DETECTION SWITCHES
SWITCH TO OFF FOR UNUSED CHANNEL
FAULT
CONT.
3A NO
MAX
AUDIO SIGNAL INPUTS / OUTPUTS
RS 485
INPUT SIGNAL
DO NOT SWITCH TO LINK WHEN DIFFERENT AUDIO
SOURCES ARE USED FOR THE ADJACENT CHANNEL
CASCADE
CONNECT ONLY ONE WIRE FOR CASCADE TO NEXT
UNIT
UNIT 1(LOW) --- UNIT 2(HIGH)
A
B
SPEAKER
-------
AUDIO SIGNAL INPUTS
(BALANCED)
STAND BY
AMP
I/P
CH 3
AMP
I/P
CH 2
AMP
I/P
CH 1
AMP
I/P
STAND BY
AMP
O/P
CH 3
AMP
O/P
CH 2 AMP
O/P
CH 1 AMP O/P
100V LINE
The above diagram shows an application using matrix and AX3700 changeover with DP2406. One of the channel
of DP2406 serves as a standby amplifier whereas other 3 channels serve respective zones.
NOTE:
Summary Of Features
Class D amplifiers for wider frequency response
Low power loss with higher efficiency circuitring
Available in 2 x 120W or 4 x 60W 100V Line
High ambient temperature operating condition
AC and DC operation
Technical Specifications
Rating
Operating Voltage
Current Consumption
Current (Load / Standby)
Input
Input Sensitivity
Outputs
Frequency response
Protection
Indicator
Cooling system
Dimension (WxHxD)
Weight
4 x 60W 100V line
230 ~ 240V ac / 24V DC
1.4A
10.2A / 0.7A
4 x XLR
1.25 Vrms Balanced
100V, 70V, 30V
100Hz ~ 16kHz + / - 3 dB
Thermal, Short Circuit AC & DC Fuse
Power, Audio Input Level, Over temperature, Amplifier Faulty
Via Continuous Operating Fan
430 x 88 x 300 mm
13.3 kg
AMPERES DP2406 MULTICHANNEL POWER AMPLIFIER
PAGE 7
Warranty Conditions
Disclaimer
AMPERES ELECTRONICS SDN BHD
MADE IN MALAYSIA
ISO 9001: 2008
Design & Manufacture of Public Address Equipment and Systems
Certicate No. 16895 / A / 0001 / UK / En
Only Amperes Electronics Service Centres are allowed to make warranty repairs : a list of Amperes
Electronics Service Centres may be asked for by the purchaser or send directly to Amperes Electronics Sdn
Bhd at 70 Jalan Industri PBP 3, Tmn Perindustrian Pusat Bandar Puchong, 47100, Puchong, Selangor,
Malaysia or its authorized master distributor, TNT Links Sdn Bhd / MyPA Systems Sdn Bhd. This warranty is
not valid if repairs are performed by unauthorized personnel or service centres.
This warranty covers only repairs and replacement of defective parts ; cost and risks of transportation as
well as removal and installation of the product from the main system are for the account of the purchaser.
This warranty shall not extend to the replacement of the unit.
This warranty does not cover damages caused by misuse, neglect, accident of the product as well as using
the product with power supply voltage other than shown on the product, or any other power supply source /
adaptor not recommended by the manufacturer.
This warranty does not cover damages caused by fire, earthquakes, floods, lightning and every cause not
directly related to the unit.
This warranty does not include any indemnity in favor of the purchaser or the dealer for the period out of use
of the unit; moreover the warranty does not cover any damages which may be caused to people and things
when using the product.
This warranty certificate is valid only for the described product, and is not valid if modifications are made on
this certificate or on the identification label applied on the product.
This warranty covers all the material and manufacturing defects and is valid for a period of 12 months from
the date of purchase or for a longer period in countries where this is stated by a national law. In this case,
the extension is valid only in the country where the product is purchased.
Amperes Electronics Sdn Bhd is not obliged to modify previously manufactured products under warranty if
the design changes or improvements are made.
Information contained in this manual is subject to change without prior notice and does not represent a
commitment on the part of the vendor. AMPERES ELECTRONICS SDN BHD shall not be liable for any
loss or damages whatsoever arising from the use of information or any error contained in this manual.
It is recommended that all services and repairs on this product be carried out by AMPERES ELECTRONICS
SDN BHD or its authorized service agents.
AMPERES series must only be used for the purpose they were intended by the manufacturer and in
conjunction with this operating manual.
AMPERES ELECTRONICS SDN BHD cannot accept any liability whatsoever for any loss or damages
caused by service, maintenance or repair by unauthorized personnel, or by use other than that intended by
the manufacturer.
Published : March 2014
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Amperes DP2406 User manual

Category
Musical Equipment
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI