Thank you for choosing another quality product from Amperes Electronics.
MA2000 Series of mixer amplifiers had been further improved for performance and durability featuring 3 output
speaker zoning with remote selection from PM Series of paging mic, priority muting over BGM sources as well as
operation using 24V DC. The P prefix of the models includes an integrated media player for FM tuner reception, USB
and SD Card Player.
We believe that this product shall be able to meet your demanding requirement with affordable pricing and
uncompromised features and quality. Though it is rather simple in the installation works, a brief read through the
manual is recommended and we are confident that you are getting a product of excellence.
INSTRUCTION MANUAL
MA2060 60W 100V
MA2012 120W 100V
MA2024 240W 100V
MA2060P/ MA2012P / MA2024P With Media Player
Mixer Amp with 3 Zone Output
VER 4 / 2020
CH1 CH2 CH3 CH5 CH6 MASTER
MIC
BASS
TREBLE
CH4
POWER
MA 2024
O
I
MA 2024
CH1 CH2 CH3 CH5 CH6 MASTER
MIC
BASSTREBLE
CH4 / MP3
POWER
MA 2024P
O
I
/ V- / V+
MODE
OFF/ON
IN
USB
MA 2024P
3
4
5
6
1
7
2
8
9
10
11
12
15
14
16
17
3. FRONT MIC INPUT JACK
Channel 1 balanced microphone input. Once inserted, it shall bypass the rear input connection.
4. INPUT LEVEL CONTROLS
Individual control knobs for input 1 to 6.
5. TONE CONTROLS
Bass and treble controls for mixed signals.
6. MASTER CONTROL
Master volume control for mixed signal; speaker and line outputs.
7. POWER SWITCH
Mains switch for ac input. Switching off the switch shall not disconnect the DC supply to the unit if it is
connected to back up battery. It is recommended that the DC back up is connected to the battery charger's
EM output instead of directly to the batteries. This shall prevent drainage of the battery bank.
100V line output can be channeled into 3 output zones and each zone can be selected via these switches
with ALL CALL. Alternatively, selection can also be done via remote paging microphone, ie. PM1060.
1. SPEAKER ZONE SELECTOR
2. LED INDICATORS
Front View:
Rear View:
19
LED indicators for Power, Protect mode and 4 segment output level meter.
13
18
8. MAINS AC CORD
Mains AC cord comes with standard British 3 pin plug with fuse rating of 5A.
Parts Identifications
PAGE 2 MA2000 SERIES | MIXER AMPLIFIER WITH 3 ZONE OUTPUT
CH1 CH2 CH3 CH5 CH6 MASTER
MIC
BASSTREBLE
CH4
POWER
MA 2024
O
I
MA 2024
WARNING !
TO REDUCE THE RISK OF FIRE OR
ELECTRIC SHOCK DO NOT EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.
RISK OF ELECTRICAL SHOCK
DO NOT OPEN
CAUTION
CH3CH5
CH6 CH4
MICLINE MICLINE MICLINE MICLINE
CH3CH4CH5CH6
MIC LEVEL (BALANCED/UNBALANCED)LINE LEVEL
MIC LEVEL
PRIORITY MUTE
CH.1 / 2 / EXT.IN
MAX
CH3CH5
CH6 CH4
MICLINE MICLINE MICLINE MICLINE
CH3CH4CH5CH6
MIC LEVEL (BALANCED/UNBALANCED)LINE LEVEL
CH.1 / 2 / EXT.IN
MAX
9. XLR INPUTS
10. PHANTOM POWER SWITCH
11. MUTE LEVEL CONTROL
12. VENT FAN
14. RCA JACK
Inputs to the unit can be either mic or line level. Select the required input type by using these switches and
plug the input source to the appropriate jack. Stereo phone jack for balanced mic input whereas the RCA jack
is for music source unbalanced line input. It is recommended that at any one time, only one type of input
source is connected to the amplifier.
13. 24V DC POWER INPUT
15. MIC / LINE LEVEL SWITCH
16. AMPLIFIER OUTPUT TERMINALS
17. REMOTE PAGING ZONE SELECTION
18. DC 24V OUTPUT
Input to battery bank for back up supply with 10A rating at full load.
2 XLR balanced inputs are available for microphones.
12V DC phantom power is available for input channel 1 & 2, which is suitable for connection to condenser
microphones. The normal mic inputs, it is recommended that the phantom power features is turned off.
Input channel 1 & 2 has priority over other channels, such that the presence of the signal shall mute other
input sources. The level of mute or mixing is controlled by this knob, which can fully or partially mute or normal
mix.
19. LINE OUTPUT
Line level output for external link. The output level is controlled by the Master volume controller.
The vent fan draws internally generated hot air & dispersed by the fan. The fan has dual speed which is
determined by the internal heat sink temperature. To allow proper cooling, please ensure that the ambient is
properly ventilated.
For unbalanced line input sources such as CD player, etc.
Terminals for connecting external speakers and is available in 3 zones.
External control of speaker zone selection via negative triggering method. Connection to Amperes PM1060 is
recommended
This 24V DC for paging mic power supply.
Parts Identifications
PAGE 3MA2000 SERIES | MIXER AMPLIFIER WITH 3 ZONE OUTPUT
PAGE 4 MA2000 SERIES | MIXER AMPLIFIER WITH 3 ZONE OUTPUT
Rear Connections
Power Input
(240V AC)
Dynamic / Condenser Mic For
Ch.1 Or 2
Paging Mic
Audio Output
( 2 Core Screen Cable )
PM1060
Remote Trigger
for Zone Selection
(6 Core Cable)
BC9740
MA2024
CD Player
RCA Cable
Tuner
Mic Cable
Dynamic Mic
with Phone Jack
Line Out to External
Link (Next Amplifier)
}
RCA Cable
Speaker
Zone 3
Speaker
Zone 1
Speaker
Zone 2
Back up Batt. E/M Output From
Battery Charger
MP1020
CD1001
amperes
AUTOMATIC BATTERY CHARGER
MENU
ENTER
PREV NEXT
CHARGING
POWER
FAULT
BC 9740
Speaker
Zone 3
Speaker
Zone 1
Speaker
Zone 2
IR
PWR/MODE EJECT
BAND
VOL - VOL +
MP 1020
MIN MAX MIN MAX
CH 1 CH 2
/ V- / V+
MODE
OFF/ON
FM
/ V- / V+
MODE
OFF/ON
FM
DUAL CHANNEL DIGITAL MEDIA PLAYER
IN
IN
WARNING !
TO REDUCE THE RISK OF FIRE OR
ELECTRIC SHOCK DO NOT EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.
RISK OF ELECTRICAL SHOCK
DO NOT OPEN
CAUTION
CH3CH5
CH6 CH4
MICLINE MICLINE MICLINE MICLINE
CH3CH4CH5CH6
MIC LEVEL (BALANCED/UNBALANCED)LINE LEVEL
MIC LEVEL
CH.1 / 2 / EXT.IN
MAX
CH3CH5
CH6 CH4
MICLINE MICLINE MICLINE MICLINE
CH3CH4CH5CH6
MIC LEVEL (BALANCED/UNBALANCED)LINE LEVEL
MIC LEVEL
PRIORITY MUTE
CH.1 / 2 / EXT.IN
MAX
Connecting Paging Microphone
PAGE 5MA2000 SERIES | MIXER AMPLIFIER WITH 3 ZONE OUTPUT
External paging desk with or without zone selection can be connected to the unit, preferable with mic level output.
Connection can be done via the front panel 1/4" stereo phone jack or rear panel XLR jack. It is recommended that
paging desk with zone selection (Amperes PM1060) be connected via the rear panel jack.
The diagram below illustrates the connection of Amperes PM1060 paging desk with zone selection :
AMPERES PM1060 PAGING DESK
Rear View
MA2024:
}
Paging Mic
Audio Output
(2 Core Screen Cable)
6 Core
Cable
Remote Zone Control
& Power Supply
Connection :
PM1060 MA2012
Remote SP1
Remote SP2
Remote SP3
- 24V DC
Remote PR
+ 24V DC
Pin 1
Pin 2
Pin 3
Pin 13
Pin 14
Pin 15
WARNING !
TO REDUCE THE RISK OF FIRE OR
ELECTRIC SHOCK DO NOT EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.
RISK OF ELECTRICAL SHOCK
DO NOT OPEN
CAUTION
CH3CH5
CH6 CH4
MICLINE MICLINE MICLINE MICLINE
CH3CH4CH5CH6
MIC LEVEL (BALANCED/UNBALANCED)LINE LEVEL
MIC LEVEL
CH.1 / 2 / EXT.IN
MAX
CH3CH5
CH6 CH4
MICLINE MICLINE MICLINE MICLINE
CH3CH4CH5CH6
MIC LEVEL (BALANCED/UNBALANCED)LINE LEVEL
PRIORITY MUTE
CH.1 / 2 / EXT.IN
MAX
Remotely Activate ALL CALL
WARNING !
TO REDUCE THE RISK OF FIRE OR
ELECTRIC SHOCK DO NOT EXPOSE THIS
EQUIPMENT TO RAIN OR MOISTURE.
RISK OF ELECTRICAL SHOCK
DO NOT OPEN
CAUTION
To remotely trigger ALL CALL on MA2000 series mixer amps
from another device we can externally install a pair of diodes to
the AC ( ALL CALL ) and PR ( PRIORITY ) ports of the mixer
amp. The diodes are then connected to the dry contact of an
external device. In the left figure, the diodes are linked to
RELAY CONTACT of an Emergency Paging Panel, EP1200.
When the EP1200 siren / message trigger is activated, it will
activate ALL CALL on the mixer amp.
PAGE 6 MA2000 SERIES | MIXER AMPLIFIER WITH 3 ZONE OUTPUT
Connecting BGM Sources
Use the right connector for the appropriate
BGM source. At any one time, only one jack
shall be connected to the inputs of the
same channel to avoid interference. Also,
please switch to the right input level
position for the correspondence input
source.
Very often BGM source shall have stereo
outputs whereas the mixer amp has only
mono input. Therefore, use either one
output of the BGM source to connect to the
input. To obtain better result of music
stereo effect, use a combiner jack (stereo
to mono) before inserting to the mixer
amplifier.
Switch to the appropriate
input level attenuator. ie.
LINE for BGM source.
RCA JACK
STEREO PHONE JACK
Balanced input source
(Line / Mic level)
MIC LINE LINE
PHANTOM POWER SWITCH
Switch on when condenser microphone is used. In normal
usage, it is recommended that it is switched off
Two channels - 1 and 2 are provided with
switchable phantom power of 12V.
MIC LINE MIC LINE
MIC LINE MIC LINE
O N
Phantom Power
PAGE 7MA2000 SERIES | MIXER AMPLIFIER WITH 3 ZONE OUTPUT
Operating the Unit ( Playing USB / SD )
Player Module
USB Input Port
Song time lapsed
/ V-
/ V+
MODE
The top button for repeating the previous song and to decrease the song volume while the
bottom one shall skip to the next song and to increase the song volume.
Press this button to play or to pause.
The menu at the display would switch between :-
RADIO ---- USB ---- SD ---- BLUETOOTH ---- RADIO
Insert a SD Card or USB into the slot and the unit shall automatically enter the playing mode.
Next, Prev & Volume Button
Play & Pause Button
Mode Button
OFF/ON
OFF/ON Button
Individual power OFF/ON for each module
/ V- / V+
MODE
OFF/ON
IN
USB
PAGE 8 MA2000 SERIES | MIXER AMPLIFIER WITH 3 ZONE OUTPUT
Operating the Unit ( FM Tuner )
Player Module
Radio Mode Display
/ V-
/ V+
MODE
To enter the radio mode, press Mode button & FM Radio reception mode shall be displayed.
Use the ‘Next’ or ‘Prev’ button to manually select the station.
Auto program select. Press this button briefly and the tuner shall automatically search the
stations.
Operating the Unit (Bluetooth)
Player Module
Bluetooth Mode Display
/ V- / V+
MODE
OFF/ON
IN
bLUE
1) On MA2000P series media player, press MODE button until
‘bLUE’ show up on the LED display, indicates that the player is
now in Bluetooth reception mode.
2) On a Bluetooth transmission device, turn On the Bluetooth
mode. It will start searching for active reception device around
the area.
Figure on the left, shows a mobile phone running on Android
detected a device named “ ZTV-CT02CA ” which is the
MA2000P player. Click the “ ZTV-CT02CA ” to pair the player.
If the pairing is successful, we shall hear “ Bluetooth successfully
connected”. Now we can play an audio file on our bluetooth
device and stream it to MA2000P.
/ V- / V+
MODE
OFF/ON
IN
FM
Mode button
Mobile phone bluetooth setting
PAGE 9MA2000 SERIES | MIXER AMPLIFIER WITH 3 ZONE OUTPUT
Remote Control
EQ
Mode
RPT
1
CLOCK
2
4
3
VOL -
VOL +
9
5
0
6
8
7
1
2
5
6
10
3
4
7
8
9
1. Power Switch : Press once to switch ON, press again to switch OFF.
2. Mode: Press this button to switch the radio / bluetooth / AUX / playback of USB / SD function.
3. MUTE : Press once to mute audio output, press again to resume volume level.
4. Next / Previous Button : In the playback mode, USB / SD songs, press this button to select previous song or next song.
In the radio mode, it is for searching stations.
5. Play / Pause Button : Press this button to switch between Play and Pause.
6. EQ: Press this button to switch EQ modes (Jazz, Pop, etc)
7. VOL +/-: Press this button to increase or decrease volume level.
8. CLOCK: Press this button to switch to clock mode.
9. RPT: During playback, press RPT button briefly to play the current track repeatedly, and the LCD will display ONE.
Press RPT button twice to play the tracks in the Folder repeatedly, and the LCD will display FOLD.
Press RPT button twice to play all the track, and the LCD will display ALL.
10. Numerical Buttons : In the radio mode, press this button to search the station. In the playback mode, press this button
to choose desired songs.
PAGE 10 MA2000 SERIES | MIXER AMPLIFIER WITH 3 ZONE OUTPUT
Connection of Jacks
6 mic / line selectable input channels, with front mic jack, phantom power
Priority muting for mic input 1 with adjustable muting level
3 zone speaker output with ALL CALL and remote triggering port
100V line output with aux 4 Ohm speaker terminal
12
3
1 2
3
MIC/BALANCED INPUT XLR (F) MIXER BALANCED OUTPUT XLR (M)
1 - GROUND / SCREEN
2 - HOT ( +VE )
3 - COLD ( - )
FOR UNBALANCED, CONNECT
PIN 1 AND 3 TOGETHER
FOR UNBALANCED, SPARE PIN 3
PHONE JACK
TIP : +VE / HOT SIGNAL
RING : -VE / COLD
SLEEVE : GROUND / SCREEN
Tone and bass controls
AC / DC operation for fixed and uninterrupted operation
Summary of Features
1
2
3
1
2
3
Technical Specifications
PAGE 11MA2000 SERIES | MIXER AMPLIFIER WITH 3 ZONE OUTPUT
Note:
The above specifications are correct at time of printing but subjected to changes without prior notice due to product
improvements.
MA2060 / MA2060P MA2012 / MA2012P MA2024 / MA2024P
Ratings
Operating voltage
Current (Load / Standby) 240V AC
24V DC requirement
Input channel
Input phantom power
Input sensitivity / impedance
Tone controls
Outputs
Output selection
Frequency response @1KHz +/- 3dB, 20-20kHz
Protections
Indicators
Cooling system
Dimensions (W x H x D)
Weight
60W 100V line 120W 100V line
220 - 240V AC or 24V DC
0.87A / 0.08A 1.0A / 0.13A
4.1A 6.3A
6 : 2 MIC ( XLR), 4 MIC/Line Selectable (RCA/Phone Jack)
Mic 1 and 2 ; 12V DC
2 x Mic (XLR) & 4 x Mic
(Phone jack) : 4 mVrms
4 x LINE (RCA) : 350 mVrms
Bass (100 Hz) ; Treble (10 KHz) +/- 3 dB
3 Zone 100V line, 4 Ohm
Front and remote triggering
175 ~ 18 KHz
Thermal, short circuit, AC and DC fuse
AC mains, clip, protect, audio input level
Dual speed fan with heat sensing
424 x 88 x 300 mm
9.80 kg 11.10 kg
10.8A
240W 100V line
1.95A / 0.17A
70 ~ 15 KHz
12.40 kg
2 x Mic (XLR) & 4 x Mic
(Phone jack) : 20 mVrms
4 x LINE (RCA) : 150 mVrms
Warranty Conditions
Disclaimer
AMPERES ELECTRONICS SDN BHD
MADE IN MALAYSIA
Published : JUNE 2020
ISO 9001: 2015
Design & Manufacture of Public Address Equipment and Systems
Certicate No. 16895 / A / 0001 / UK / En
Only Amperes Electronics Service Centres are allowed to make warranty repairs : a list of Amperes
Electronics Service Centres may be asked for by the purchaser or send directly to Amperes Electronics Sdn
Bhd at 70 Jalan Industri PBP 3, Tmn Perindustrian Pusat Bandar Puchong, 47100, Puchong, Selangor,
Malaysia or its authorized dealers. This warranty is not valid if repairs are performed by unauthorized
personnel or service centres.
This warranty covers only repairs and replacement of defective parts ; cost and risks of transportation as
well as removal and installation of the product from the main system are for the account of the purchaser.
This warranty shall not extend to the replacement of the unit.
This warranty does not cover damages caused by misuse, neglect, accident of the product as well as using
the product with power supply voltage other than shown on the product, or any other power supply source /
adaptor not recommended by the manufacturer.
This warranty does not cover damages caused by fire, earthquakes, floods, lightning and every cause not
directly related to the unit.
This warranty does not include any indemnity in favor of the purchaser or the dealer for the period out of use
of the unit; moreover the warranty does not cover any damages which may be caused to people and things
when using the product.
This warranty certificate is valid only for the described product, and is not valid if modifications are made on
this certificate or on the identification label applied on the product.
This warranty covers all the material and manufacturing defects and is valid for a period of 36 months from
the date of purchase or for a specified period in countries where this is stated by a national law. In this case,
the extension is valid only in the country where the product is purchased.
Amperes Electronics Sdn Bhd is not obliged to modify previously manufactured products under warranty if
the design changes or improvements are made.
Information contained in this manual is subject to change without prior notice and does not represent a
commitment on the part of the vendor. AMPERES ELECTRONICS SDN BHD shall not be liable for any
loss or damages whatsoever arising from the use of information or any error contained in this manual.
It is recommended that all services and repairs on this product be carried out by AMPERES ELECTRONICS
SDN BHD or its authorized service agents.
AMPERES series must only be used for the purpose they were intended by the manufacturer and in
conjunction with this operating manual.
AMPERES ELECTRONICS SDN BHD cannot accept any liability whatsoever for any loss or damages
caused by service, maintenance or repair by unauthorized personnel, or by use other than that intended by
the manufacturer.
AMPERES ELECTRONICS SDN BHD
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12

Amperes MA Series 2060, 2120, 2024 User manual

Category
Car audio amplifiers
Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI