This manual explains how to set up UR-4MD DICOM
functions.
DICOM functions are supported on the UR-4MD that has
firmware version 1.20a7 and later. Contact the TEAC’s
authorized reseller where you purchased the unit for
information about the latest firmware.
An unique “DICOM Activation Key” (sold separately) is
required to activate DICOM functions per unit. Contact
the TEAC’s authorized reseller to obtain the activation
key. At that time, you will be asked to provide a unit-
unique MAC address. See “Activation” for how to find the
address.
DICOM connection is initiated by a computer connected in
the same network with the UR-4MD. The computer must
have a web browser such as Internet Explorer, Microsoft
Edge, Chrome™ browser, Firefox or Safari installed to enter
the activation key and make all DICOM settings.
DICOM communication uses an IP address assigned
on the UR-4MD. The IP address can be automatically
obtained if the connected network supports DHCP. If
not, the default address 192.168.0.121 can be used. If
the default address conflicts with any existing address, a
usable address can be manually assigned.
GeneralContents
General ......................................................2
Settings ..................................................3
Getting started ........................................3
How to obtain an IP address ..............................3
Obtain an IP address automatically (DHCP) .............4
Obtain an IP address manually .........................5
Establishment of Network Communication ...............6
Activation ................................................7
Basic settings screen operation ......................... 10
Explanation of setting items ............................ 11
General ..............................................11
DICOM Storage ......................................11
Modality Worklist Management ......................12
ECHO testing ...........................................13
Using DICOM functions .................................... 14
Storage function ........................................14
Modality Worklist Management function ................ 14
DICOM® is the registered trademark of the National Electrical
Manufacturers Association for its standards publications relating to
digital communications of medical information.
Mac and Safari are trademarks of Apple Inc., registered in the U.S. and
other countries.
Internet Explorer and Microsoft Edge are either registered trademarks
or trademarks of Microsoft Corporation in the United States and/or
other countries.
Chrome™ browser is a trademark of Google LLC.
Firefox is a trademark of the Mozilla Foundation in the U.S. and other
countries.
Other company names, product names and logos in this document
are the trademarks or registered trademarks of their respective owners.
2