GE GUD27GSSJ0WW Installation guide

Type
Installation guide

This manual is also suitable for

Installation Unitized Gas
Instructions Washer/Dryer
Questions on Installation? Call: 1-800-GECARES {US)or Visit our Web site ot: www.GEAppliances.com (US;.
In Canada, call 800-561-3344 or visit www.GEAppliances.ca.
BEFOREYOU BEGIN
Readtheseinstructionscompletelyandcarefully.
•IMPORTANT-savetheseinstructionsfor
localinspector'suse.
IMPORTANT- Observe all governing
codesand ordinances.
Note to Installer - Be sure to leave these
instructionswith thecustomer.
Note to Customer - Keepthese instructions
with your Use and Care Book for future
reference.
Beforethe appliance isremovedfrom service
or discarded, remove the washer and dryer
door.
Inspectthedryerexhaustoutletandstraighten
theoutlet walls ifthey are bent.
Service information and the wiring diagram
are locatedat theaccesspanel.
Do not allow childrenon or in the appliance.
Close supervision of children is necessary
whentheapplianceisusednear children.
Install the dryer where the temperature is
aboveSO°F(lO°C)for satisfactoryoperationof
thedryer controlsystem.
A WARNING RISK OF FIRE
. Toreducetheriskofsevereinjuryordeath,followallinstallationinstructions.
. Applianceinstallationmustbeperformedbyaqualifiedinstaller.
. Installtheclothesapplianceaccordingtotheseinstructionsandinaccordancewithlocal
codes.Intheabsenceoflocalcodes,installationmustcomplywithNationalFuelGasCode,
ANSIZ223,1/NFPA54ortheCanadianNaturalGasandPropaneInstallationCode,CSAB149.t.
. CaliforniaSafeDrinkingWaterandToxicEnforcementAct.
Thisact requiresthegovernorofCaliforniatopublisha listofsubstancesknowntothe
statetocausecancer,birthdefectsorotherreproductiveharmandrequiresbusinesses
to warn customersof potentialexposureto suchsubstances.Gasappliancescan
causeminorexposuretofourofthesesubstances,namelybenzene,carbonmonoxide,
formaldehydeandsoot,causedprimarilybytheincompletecombustionofnaturalgas
or LPfuels.Properlyadjusteddryerswillminimizeincompletecombustion.Exposureto
thesesubstancescanbeminimizedfurtherbyproperlyventingthedryertotheoutdoors.
. Thisappliancemustbeexhaustedtotheoutdoors.
. Useonly4"rigidmetalductingforexhaustingtheappliancetotheoutdoors.
. DONOTinstalla clothesdryerwithflexibleplasticductingmaterials.Ifflexiblemetal
(semi-rigidorfoil-type)ductisinstalled,it mustbeULlistedandinstalledinaccordance
withtheinstructionsfoundin"ConnectingTheDryerToHouseVent"onpage8ofthis
manual.Flexibleventingmaterialsareknowntocollapse,beeasilycrushed,andtraplint.
Theseconditionswillobstructdryerairflowandincreasetheriskoffire.
. Donotinstallorstorethisapplianceinanylocationwhereitcouldbeexposedtowater
andorweather.
. Savetheseinstructions.(Installers:Besuretoleavetheseinstructionswiththecustomer).
TOOLS YOU WILL NEED
Ix2I
10"ADJUSTABLEWRENCHES __
8"PIPEWRENCH LEVEL
SLIPJOINTPLIERS FLATBLADESCREWDRIVER
1/4" Nutdriver
In the state of Massachusetts:
Installation must be performed by
a qualifiedor licensed contractor,
plumber, or gasfitter qualified or
licensedbythe state.
When using ball-type gas shut-off
valves,they shallbe T-handletype.
A flexiblegasconnector,when used,
mustnotexceed3feet.
MATERIALS YOU WILL NEED
)%
4"DIA.METALDUCT
(RECOMMENDED) 4"DIAMMETALELBOW
EXHAUSTHOOD
4"DIA.FLEXIBLEMETAL(SENI-RIGID)
ULLISTEDTRANSITIONDUCT
(IFNEEDED)
KITWXO8XlO077(iNCLUDES2ELBOWS)
4"DIA.FLEXIBLEMETAL(FOILTYPE)
ULLISTEDTRANSITIONDUCT
(IFNEEDED.)
4"DUCTCLAMPS
OR
4"SPRINGCLAMPS
(x2)
PIPE
COMPOUND SOAPSOLUTION
FORLEAKDETECTION
DUCTTAPE
FLEXIBLEGASLINECONNECTOR
2 Washer Hoses
PARTS SUPPLIED
d
2 Stainer Screens/
2 Rubber Washers Rubber Washers
(washers may be in water hoses)
00%
SAFETYGLASSES
GLOVES
(5
4"COVERPLATE(IFNEEDED)
(KITWEIM454)
1.Cable Tie
233D1835PO03
31-16727 !2-!4 GE PrintedinMexico
Installation
INSTALLATION REQUIREMENTS LOCATION
Thisappliance must beinstalled on firm flooring to minimize
vibration during spin cycle. Concrete flooring is best, but
wood base issufficient, provided floor support meets FHA
standards. This appliance should not be installed on rugs
or exposed to weather.
PLUMBING
WATERPRESSURE- Must be 20 psi minimum to 120 psi
maximum.
WATERTEIVlPERATURE- Household water heater should be
set to deliver water at 120° to !50°F (50° to 66°C)IN THE
WASHERwhen hot wash is selected.
SHUTOFFVALVES-Bothhot and cold shutoffvalves (faucets)
should be supplied.
DRAIN- Water may be drained into standpipe or set tub.
Discharge height MUSTNOT BE LESSTHAN 30 INCHES,
and no more than 6 feet above the base of the washer.
Standpipe must be 1-1/2 inches minimum inside diameter
and must be open to atmosphere.
nstructions
ELECTRICAL REQUIREMENTS
CAUTION: Beforeplugging in washer, read the following
electrical requirements.
CAUTION: Forpersonal safety, do not use anextension
cord or adapter plug with this appliance. Donot, under any
circumstances, cut or remove the third grounding prong
from the power cord. Follow national electrical codes and
ordinances. Thisappliance must besupplied with the voltage
and frequency indicated on the rating plate (located at the
top of the dryer front panel),and connected to an individual,
properly grounded branch circuit, protected by a 15- or 20-
amp circuit breaker or time-delay fuse. If the electric supply
provided does not meet the above requirements, call a
licensed electrician.
Step 1
Step 2
Step 3
Step 4
Step 5
Step 6
Step 7
Step 8
Step 9
Verify Your Gas Installation (seesection 2).
Prepare the Area and Exhaust for Installation of
appliance (seesection !).
Check and Insure the Existing External Exhaust
is Clean (seesection !) and Meets Attached
Installation Specifications (seesection 6).
Remove the Foam Shipping Pads(seesection !).
Move the appliance to the Desired Location.
Levelyour appliance (seesection 8).
Connect the Gas Supply (seesection 3) and check
for leaks (seesection 4).
Connect the External Exhaust (seesection 7).
Connect to plumbing facilities (seesection !!).
Step 10 Connect the Power Supply (seesection 5).
Step 11 Check the Operation of the Power Supply, Gas
Connections, and Venting.
Step 12 Place the Owners Manual and the Installation
Instructions in a Location Where They Will Be
Noticed Bythe Owner.
For Alcove or Closet Installation see section 13.
For Bathroom or Bedroom Installation seesection 14.
For Mobile or Manufactured Home see section 12.
ADJUSTING FOR ELEVATION
. Gas clothes dryers input ratings are based on sea level
operation and need not be adjusted for operation at
or below 2000 ft. elevation. For operation at elevations
above 2000 ft., input ratings should be reduced at a rate
of 4 percent for each !000 ft. above sea level.
. Installation must conform to local codes and ordinances
or, in their absence with the National Fuel Gas Code,
ANSI Z223.1/NFPA 54, or the Natural Gas and Propane
Installation Code,CSAB!49.!.
2
Installation instructions
24" NOMINAL PRODUCT DIMENSIONS
L5
51"
!9.! ''J
Water Inlets
(rear)
51°
* Dimension represents door closed including handle and knobs.
NOTE:With feet set at mid position, feet can be adjusted +_.575".
Gas Inlet
(Rearview of appliance)
27" NOMINAL PRODUCT DIMENSIONS
52.9"
j
2ool oo O
Drain outlet
-_ (rear)
V3.9"
_--- 26.8"
]
36.5"
J
4.35"
i lib
_------ 30.85"------_
* Dimension represents door closed including handle and knobs.
NOTE:With feet set at mid position, feet can be adjusted +_.575".
Gas Inlet
(Rearview of appliance)
3
Installation Instructions
Minimum Clearance Other Than Alcove or Closet Installation
Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and rear.Consideration
must be given to provide adequate clearance for installation and service.
m PREPARING FOR INSTALLATION
OF NEW APPLIANCE
DISCONNECTING GAS
TURNGAS
SHUT-OFFVALVE IC_-/_ DISCONNECTANDDISCARDOLD _/_,_,
TOTHEOFF _ FLEXIBLEGASCONNECTORAND
POS,T,0N OLDTRANS,T,ONDUCT,NG
MATERIAL.REPLACEWITHNEW
CSA(AGA)APPROVEDFLEXIBLE
GASLINECONNECTORANDUL
APPROVEDTRANSITIONDUCT.
WARNING - NEVERREUSEOLD
FLE×IBLE CONN ECTORS.
Theuse of old flexible connectors can cause leaks and
personal injury. Always use new flexible connectors
when installing gas appliances.
REMOVING LINT FROM WALL
EXHAUST OPENING
Removeand discard existing plastic or metal foil
transition duct and replace with ULlisted transition duct.
_j WALL
INTERNAL_t_,].DUCT _ CHECKTHATEXHAUST
OPENING -'_-_ \ G "'.. HOODDAMPEROPENS
ANDCLOSESFREELY.
TILTTHEAPPLIANCE
SIDEWAYSAND REMOVE
THE FOAMSHIPPINGPADS
BYPULLINGATTHESIDES
AND BREAKINGTHEMAWAY
FROMTHEAPPLIANCELEGS.
BESURETOREMOVEALL OF
THE FOAMPIECESAROUND
THE LEGS.
After the machine is in the home,
remove remaining packing material/
carton from washer.
DO NOT REMOVE SHIPPING ROD AT
THISTIME.
Removestyrofoam block. Removethe
bag containing theWasher hosesand
parts parts from tub. Put styrofoam
block back in tub opening to hold tub
in placeduring the rest of installation.
Hove washer close to final position.
Make sure there is at least a 24"
clearance on right side of washer to
remove shipping bar.PULLSHIPPING
BAROUT USINGYELLOWPLASTIC
HANDLE. Keep bar so it can be
reinstalled if washer is ever moved
again.
II
StyrofoamBlock
WashXerHoses
and Parts
Yellow
" Plastic
/ Handle
NEW HONE OR REMODELING FAUCETS/
DRAIN STANDPIPE/ELECTRICAL LOCATIO N
Right side of
Laundry Center
12"-_
_ .................. _|
Locate spigots, "
drain standpipe s3" |
and electrical plug |
!
in this area
!
FLOOR
I-_ GAS REQUIREMENTS
WARNING
, Installation must conform to local codes and
ordinances, or in their absence, with the National
Fuel Gas Code, ANSI Z223.1/NFPA 54, or the
Natural Gas and Propane Installation Code, CSA
B149.1
, This gas dryer is equipped with a Valve & Burner
Assembly for use only with natural gas. Using
conversion kit WE25H73 for 24" Models or
WE25H74 for 27" Models, your local service
organization can convert this dryer for use with
propane (LP} gas. ALL CONVERSIONSMUST BE
MADE BY PROPERLYTRAINED AND QUALIFIED
PERSONNELAND IN ACCORDANCEWITH LOCAL
CODESAND ORDINANCE REQUIREMENTS.
Theappliancemustbedisconnectedfrom the gassupply
pipingsystemduring anypressuretestingofthat system
at a testpressureinexcessof0.5PSI(3A KPa).
The appliance must be isolated from the gas supply
piping system by closing the equipment shut-off valve
during any pressuretesting of the gassupply piping of
test pressureequal to or lessthan 0.5PSI13.4KPa).
27" GASSUPPLYCONNECTION
3"
Note: 24" Gas supply connection has a flexible
hose thus dimensions will vary.
4
Installation Instructions
GAS SUPPLY
, A 1/8-in.National Pipe Taper thread plugged tapping,
accessible for test gauge connection, must be installed
immediately upstream of the gas supply connection to
the dryer, Contact your local gas utility should you have
questions on the installation of the plugged tapping.
. Supply line isto be !/2-in. rigid pipe and equipped with
an accessible shut-off within 6 ft. of, and in the same
room with the dryer.
,Use pipe thread sealer compound or Teflon tape
appropriate for natural or LPgas.
, You must usewith this dryer a flexible metal connector
listed ANSI Z21.24 / CSA 6.10. The length of the
connector shall not exceed 3 ft.
, Connect flexible metal connector to dryer and gas
supply.
, Open shut-off valve.
RECONNECTING GAS
Listed connector ANSI Z21.24 / CSA6.10
BACK OF
APPLIANCE
24"
NEW METAL _.. _ _k_>4/ '_
FLEXIBLEGAS
LINECONNECTOR
/
24" & 27"
INLET FROM
APPLIANCE
FLARE
ADAPTOR
27" ONLY
NEW METAL
FLEXIBLE GAS
LINE CONNECTOR
ADAPTOR
/8" NPT INLET
FROM APPLIANCE
27"ONLY
ELBOW
27" ONLY
NPT PIPE PLUG
FOR CHECKING GAS
INLET PRESSURE
SHUT-OFF VALVE
AT LEAST 1/2"
FLOOR
ITEHS NOT SUPPLIED
Note: The connector and fittings are designed for use only
on the original installation and are not to be reused for
another appliance or at another location. Keepflare end of
adaptor free of grease, oil and thread sealant.
CAUTION: Use adopters as shown. Connector nuts must
not be connected directly to pipe threads.
27"
APPLYPIPECOMPOUND
TOTHEADAPTORAND
APPLIANCEGASINLET.
TIGHTENTHEFLEXIBLEGASLINETO
THEADAPTORUSING2ADJUSTABLE
WRENCHES.
APPLY PIPE COMPOUND TO
APPLIANCE INLET
24"
;HTEN THE FLEXIBLE GAS
LINE TO THE APPLIANCE
INLET USING 2 ADJUSTABLE
WRENCHES.
24" & 27"
_ APPLY PIPECOMPOUND
TO ALL MALE THREADS
24" & 27"
5
TIGHTEN ALL CONNECTIONS USING TWO
ADJUSTABLE WRENCHES.
DO NOT OVERTORQUE GAS CONNECTIONS!
Installation instructions
[-4]LEAK TEST
I WARNING: NEVER USE AN OPEN
FLAME TO TEST FOR GAS LEAKS.
OPEN
GASVALVE.
Check oil connections for leakswith soapy solution or equivalent.
Apply soap solution. Bubbles indicate leaks. Leak test solution
must not contain ammonia which could cause damage to the
brass fittings, tfleak are found, close valve retighten thejaint and
repeat the soap test.
[_ELECTRICAL CONNECTION INFORMATION
WARNING - TO REDUCE THE
RISK OF FIRE, ELECTRICAL SHOCK,
AND PERSONAL INJURY:
. DO NOT USEAN EXTENSIONCORDORAN ADAPTER
PLUGWITH THISAPPLIANCE.
Dryer must be electrically grounded in accordance
with local codes and ordinances, or in the absence
of local codes, in accordance with the NATIONAL
ELECTRICALCODE,ANSI/NFPANO.70.
ELECTRICAL REQUIREMENTS
This appliance must be supplied with 120V, 60Hz, and
connected to a properly grounded branch circuit,
protected by a 15- or 20- amp circuit breaker or time-
delay fuse. If electrical supply provided does not meet the
above specifications, it is recommended that a licensed
electrician install an approved outlet.
, WARNING - THIS DRYER IS
EQUIPPED A THREE-PRONG (GROUNDING)
PLUG FOR 'fOUR PROTECTION AGAINST
SHOCK HAZARD AND SHOULD BE PLUGGED
DIRECTLY INTO A PROPERLY GROUNDED
THREE-PRONG RECEPTACLE. DO NOT CUT
OR REMOVE THE GROUNDING PRONG FROM
THIS PLUG.
ENSURE PROPERGROUND EXISTSBEFOREUSE.
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of
malfunction or breakdown, grounding will reduce the risk
of electric shock by providing a path of least resistance
of electric current. This appliance is equipped with a
cord having an equipment-grounding conductor and
a grounding plug. The plug must be plugged into an
appropriate outlet that isproperly installed and grounded
in accordance with all local codes and ordinances.
WARN IN 6 - Improper connectionofthe
equipment-grounding conductor can result in a risk
of electric shock. Check with a qualified electrician
or serviceman if you are in doubt as to whether the
appliance is properly grounded.
Do not modify the plug provided with the appliance. If it
will not fit the outlet, have a proper outlet installed by a
qualified electrician.
_-I EXHAUST INFORMATION
I WARNING - IN CANADA AND IN THE
UNITED STATES,THE REQUIRED EXHAUST DUCT
DIAMETER IS 4 IN (102ram). DO NOT USE DUCT
LONGER THAN SPECIFIED IN THE EXHAUST
LENGTH TABLE.
Using exhaust longer than specified length will:
Increase the drying times and the energy cost.
Reducethe dryer life.
Accumulate lint, creating a potential fire hazard.
The correct exhaust installation is YOUR
RESPONSIBILITY.Problems due to incorrect installation
are not covered by the warranty.
Remove and discard existing plastic or metal foil
transition duct and replace with ULlisted transition duct.
The MAXIMUMALLOWABLEduct length and number of
bends of the exhaust system depends upon the type of
duct, number of turns, the type of exhaust hood (wall
cap), and all conditions noted below. The maximum duct
length for rigid metal duct isshown in the table below.
6
Installation instructions
Use only for short
run installations
No. of 900 Rigid Rigid
Elbows Metal Metal
O 56 Feet 42 Feet
i 48 Feet 34 Feet
2 40 Feet 26 Feet
3 32 Feet 18 Feet
24" DRYEREXHAUSTLENGTH
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended Use only for short
run installations
No. of 900 Rigid Rigid
Elbows Metal Metal
O 45 Feet 56 Feet
i 53 Feet 26 Feet
2 24 Feet 16 Feet
EXHAUST INFORMATION (CONT.)
27" DRYEREXHAUSTLENGTH
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
, For every extra 90° elbow, reduce the allowable vent
system length by 10ft.
, Two 45°elbows will be treated likeone 90°elbow. Forthe
sideexhaust installations,add one 90°elbow tothe chart.
, The total vent system length includes all the straight
portions and elbows of the system (transition duct
included).
EXHAUST SYSTEM CHECK LIST
HOOD ORWALL CAP
, Terminate in a manner to prevent back drafts or entry
of birds or other wildlife.
, Termination should present minimal resistance to
the exhaust air flow and should require little or no
maintenance to prevent clogging.
, Never install u screen in or over the exhaust duct. This
could cause lint build up.
, Wall cups must be installed at least 12 in.above ground
level or any other obstruction with the opening pointed
down.
SEPARATIONOFTURNS
For best performance, separate all turns by at least 4
ft. of straight duct, including distance between lust turn
and exhaust hood.
TURNS OTHERTHAN 90°
, One turn of 450 or less may be ignored.
, Two 450 turns should be treated us one 900 turn.
, Each turn over 450 should be treated us one 900 turn.
SEALINGOFJOINTS
, Alljoints should be tight to avoid leaks.The mule end of
each section of duct must point away from the dryer.
, Do not assemble the ductwork with fasteners that
extend into the duct. They will serve as a collection
point for lint.
, Duct joints can be made air and moisture-tight by
wrapping the overlapped joints with duct tape.
, Horizontal runs should slope down toward the outdoors
1/4 inch per foot
INSULATION
Duct work that runs through an unheated urea or is
near air conditioning should be insulated to reduce
condensation and lint build-up.
P-JEXHAUST CONNECTION
, WARNING - TO REDUCE THE
RISK OF FIRE OR PERSONAL INJURY:
, This apliancce must be exhausted to the outdoors.
, Use only 4" rigid metal ducting for the home exhaust
duct.
, Use only 4" rigid metal or UL-listed flexible metal
(semi-rigid or foil-type) duct to connect the dryer
to the home exhaust duct. It must be installed
in accordance with the instructions found in
"Connecting The Dryer To House Vent" on page 8 of
this manual.
, Donot terminate exhaust inu chimney, uwall, uceiling,
gas vent, crawl space, attic, under an enclosed floor,
or in any other concealed space of u building. The
accumulated lint could create a potential fire hazard.
, Never terminate the exhaust into a common duct
with u kitchen exhaust system. A combination of
grease and lint creates mpotential fire hazard.
, Do not use duct longer than specified in the exhaust
length table. Longer ducts can accumulate lint,
creating u potential fire hazard.
, Never install u screen in or over the exhaust duct. This
will cause lint to accumulate, creating mpotential fire
hazard.
, Do not assemble ductwork with any fasteners that
extend into the duct. Thesefasteners can accumulate
lint, creating mpotential fire hazard.
, Do not obstruct incoming or exhausted air.
, Provide an access for inspection and cleaning of
the exhaust system, especially at turns and joints.
Exhaust system shall be inspected and cleaned at
least once year.
THIS DRYER COMES READY FOR REAR
EXHAUSTING. IF SPACE IS LIMITED, USE
THE INSTRUCTIONS IN SECTION 9 TO
EXHAUST DIRECTLY FROM THE SIDES OR
BOTTOM OF THE CABINET.
EXTERNALDUCT
OPENING
CSA(AGA}APPROVED
NEWFLEXIBLEGAS For straight line installation, connect
LINECONNECTOR the drger exhaust to the external
exhaust hood using duct tape or
GAS damp.
INLET
PIPE
DUCTTAPEOR
DUCTCLAMP
4" METALDUCTCUT
TO PROPERLENGTH
DUCTTAPEOR
DUCTCLAMP
7
Installation instructions
STANDARD REAR EXHAUST
(Vented above floor level)
r
x._
J
N
IITOMINIMIZE
IIEXHAUST BLOCKAGE
//i
ELBOW HIGHLY
RECOMMENDED
NOTE: ELBOWS WILL PREVENT DUCT KINKING AND COLLAPSING
I-8-ILEVELING AND STABILIZING YOUR
APPLIANCE
_E LEVEL
-TO-SIDE.
LEVEL
FRONT-TO-BACK.
2LEVELINGLEGS
Level and stabilizing your appliance
1. Carefully move the appliance to its final location.
Gently rock the appliance into position. It is important
not to damage the rubber leveling legs when moving
your appliance to its final location. Damage legs can
increase appliance vibration. It may be helpful to
spray window cleaner on the floor to help move your
appliance to its final position.
Note: do not usewasher cover to lift the unit.
2. To ensure the appliance is level and solid on all four
legs, tilt the appliance forward so the rear legs are off
the ground. Gently set the appliance back down to
allow the rear legs to self adjust.
3.With the appliance in its final position, place a level on
top of back part of the washer lid and check it side to
side, then check front to back. Screw the front leveling
legs up or down to ensure the appliance is resting solid
on all four legs (no rocking or the appliance should
exist), turn the lock nuts on each leg up toward the base
of the unit and snug with a wrench.
Note: Keep the leg extension at minimum to prevent
excessive vibration. The farther out legs are extended, the
more the unit will vibrate.
CONNECTING THE DRYER TO HOUSE
VENT
RIGIDMETALTRANSITIONDUCT
Forbest drying performance,a rigid metal transition duct is
recommended.
Rigidmetaltransitions ducts reducethe risk of crushingand
kinking.
UL-LISTEDFLEXIBLEMETAL(SEMI-RIGID)TRANSITIONDUCT
tf rigidmetal ductcannot beused,thenUL-listedflexiblemetal
(semi-rigid)ductingcan beused(KitWX08X10077).
Never install flexible metal duct in walls, ceilings,floors or
otherenclosedspaces.
Formanyapplications,installingelbowsat boththe dryerand
thewall ishighlyrecommended(seeillustrationsonpage 9).
Elbowsallowthe dryerto sit closeto the wallwithout kinking
and or crushing the transition duct, maximizing drying
performance.
Avoidrestingthe duct on sharpobjects.
UL-LISTEDFLEXIBLEMETAL(FOIL-TYPE}TRANSITIONDUCT
tn special installations,it may be necessaryto connect the
dryerto the housevent usinga flexiblemetal (foiltype)duct.
AUL-listedflexiblemetal (foil-type)ductmay be usedONLYin
installations where rigid metal or flexible metal (semi-rigid)
ducting cannot be usedAND where a 4" diameter can be
maintained throughout the entire length of the transition
duct.
tn Canadaand the United States,onlythe flexible metal(foil-
type) ducts that comply with the "Outlinefor ClothesDryer
TransitionDuctSubject2158A"shallbe used.
Total length of flexible metal duct should not exceed8 feet
(2.4m).
Avoidrestingthe duct on sharpobjects.
Forbestdryingperformance:
1.Slideoneendof theduct overtheclothesdryeroutlet pipe.
2.Securetheduct with a clamp.
3.Withthe dryerinits permanentposition,extendthe ductto
its full length.Allow 2" of duct to overlapthe exhaustpipe.
Cutoff and removeexcessduct. Keeptheduct asstraight
aspossiblefor maximumairflow.
4.Securetheduct to the exhaustpipewith the otherclamp.
8
Installation instructions
DO
ELBOWHIGHLY
RECOMMENDED
USE
DO NOT _
EXCESSIVE
DON'T
EXHAUST
[-_ 24" MODELS ONLY:
DRYER EXHAUST TO RIGHT, LEFT OR
BOTTOM CABINET
_WARNING - BEFOREPERFORMING
THIS EXHAUST INSTALLATION, BE SURE
TO DISCON NECTTHEAPPLIANCE FROM
ITS ELECTRICAL SUPPLY. PROTECT
YOUR HANDS AND ARMS FROM SHARP
EDGES WHEN WORKING INSIDE THE
CABINET. BE SURE TO WEAR GLOVES.
For downward venting, rotate elbow
sections so that elbow points downward
L
REMOVE
DESIRED
KNOCKOUT
(ONLY 1)
0
!
FLO0
EXHAUST TO LEFT OR RIGHT SIDE OF
CABINET
, For side ducting, remove the knockout (ONLY 1). Rotate
elbow sections so that the opening points to the side.
Preassemble 4" elbow with 4" duct. Use only 4" UL
approved rigid metal for ducting inside the dryer.
, Insert duct assembly through the side opening and
connect to the internal elbow.
WARNING- Besurenotto pullordamage
the electrical wires inside the dryer when inserting the
duct.
4" UL approved rigid metal
DUCT
TAPE
Apply duct tape as shown on the joint between the dryer
internal duct and the straight duct pipe.
LWARNING-
Internal duct joints must be
R secured with tape, otherwise
they may separate and cause
a safety hazard.
27" MODELS ONLY:
DRYER EXHAUST TO RIGHT, LEFT OR
BOTTOM CABINET
,_ WARNING -BEFOREPERFORMING
THIS EXHAUST INSTALLATION, BE SURE
TO DISCONNECT TH EAPPLIANCE FROM
ITS ELECTRICAL SUPPLY. PROTECT
YOUR HANDS AND ARMS FROM SHARP
EDGES WHEN WORKING INSIDE THE
CABINET. BE SURE TO WEAR GLOVES.
For downward venting, rotate elbow
sectionsm, so that elbow points downward.
9
Installation instructions
EXHAUST TO LEFT OR RIGHT SIDE OF
CABINET
. Rotote elbow sections so thot the opening points to the
side to which you wont to vent. Preossemble 4" elbow
with 4" duct. Use only 4" UL opproved rigid metol for
ducting inside the dryer.
. Connect duct ossembly to the internol elbow.
WARNING- Besure not to pull or damage the
electrical wires inside the dryer when inserting the duct.
IF] F] /
. Apply duct tope os shown on the joint between the
dryer internol duct ond the stroight duct pipe.
WARNING-
Internal duct joints must be
H secured with tape, otherwise
they may separate and cause
a safety hazard.
PLUMBING INFORMATION WATER
[ -ISU PPL¥ REQUIREMENTS
. HOTAND COLD WATERFAUCETS- Must be within 42"
of the appliance water inlet hose connections. The
faucets must be 3/4" garden hose-type so inlet hoses
can be connected.
. WATER PRESSURE- Must be between 10 and 120
pounds per square inch with a maximum unbalance
pressure, hot vs.cold flowing, of 10 pounds per square
inch.
. WATERTEMPERATURE- Water heater should be set to
deliver 1/40° to 150°F (60° to 66°0 in the washer when
HOTwash isselected.
. SHUT-OFFVALVES- Both hot and cold water shut-off
valves (faucets) should be supplied.
. LOCATION- Do not install appliance in an area where
the temperature will fall below freezing. If appliance
is stored or transported in freezing temperatures, be
sure all water from the fill and drain systems has been
removed.
DRAIN REQUIREMENTS
. DRAINRATE- The drein or stendpipe must be copoble
of occepting o dischorge ot the rote of 16 gollons per
minute.
. DRAINHEIGHT- The droin height must be 33" minimum
ond 96" moximum.
STANDPIPEDIAMETER- The standpipe diameter must
be 1-1/2" minimum. There MUSTbe an air gap around
the drain hose in the standpipe. A snug fit can cause a
siphoning action.
SIPHONBREAK- For a drain facility less than 33" high,
the hose, coupling and clamps provided in the machine
must be used and, in addition, a siphon break MUSTbe
installed on the back of the machine. Obtain and use a
siphon break kit and follow the instructions in the kit.
ilTICONNECTING TO PLUMBING
FACILITIES
If not instolled, instoll rubber wosher in one end of hot woter
hose. Threod hot woter hose onto connection Iobeled Hot
top reor of wosher. Hondtighten, pluson odditionol 1/8 turn
with pliers.
Ifnot instolled,instoll rubber wosher in one end of coldwoter
hose. Threod cold woter hoseonto connection Iobeled Cot
top reor of wosher. Hondtighten, pluson odditionol 1/8 turn
with pliers.
Moveopplionce os closeto finol Iocotion os possible,leoving
room for you to moke woter, droin, electricol ond vent
connections to your home.
NOTE: If longer droin hose
is required, order droin hose
extension kit, GE port number
WH49X301.Connectodditionol
droin hose (contoined in kit) to
originol hose with hose clomp
(contoined in kit).
Insertfreeendofdroin hoseinto
droin opening ofyour home up
to droin hose stopper (do not
removehosestopperitprevents
siphoning). If woter volves ond
droin ore built into woll, fosten
droin hosetooneofwoter hoses
with coble tie provided (ribbed
side on inside[ If your droins is
o stondpipe,fosten droin hose
to stondpipe with coble tie
provided.
10
Installation instructions
_-2]MOBILE OR MANUFACTURED HOME
INSTALLATION
, Installation MUST conform to the MANUFACTURED
HOME CONSTRUCTION & SAFETY STANDARD,
TITLE 24, PART 32-80 or, when such standard is not
applicable, with AMERICAN NATIONAL STANDARD
FORMOBILEHOME,ANSi/NFPA NO. 501B.
, The appliance MUST be vented to the outdoors with
the termination securely fastened to the mobile home
structure.
, Thevent MUSTNOTbe terminated beneath a mobile or
manufactured home.
, Thevent duct material MUSTBEMETAL.
KIT 14-D346-33 MUSTbe used to attach the appliance
securelyto the structure.
Thevent MUSTNOTbe connectedto anyother duct, vent,or
chimney.
, Do not use sheet metal screws or other fastening
devices which extend into the interior of the exhaust
vent.
Provideanopening with a freearea of at least 25 sq.in.for
introductionof outsideair intothedryer room.
ALCOVE OR CLOSET INSTALLATION
_0"
, If your appliance isapproved for installation in an alcove
or closet, it will be stated on a label on the appliance
back.
Thedryer MUSTbeventedto theoutdoors.Seethe EXHAUST
INFORMATIONsection.
Donot install this appliance with less than the minimum
clearances shown above.
Thecloset shouldbe vented to the outdoors to prevent gas
pocketingin caseofa gasleakinthe supplyline.
Nootherfuel-burningapplianceshallbeinstalledin thesame
closetwith the appliance.
CONSIDERATION MUST BE GIVEN TO PROVIDE
ADEQUATE CLEARANCES FOR INSTALLATION
AND SERVICE.
,WARNING: DONOTINSTALLTHIS
APPLIANCE IN A CLOSET WITH A SOLID DOOR.
DOOR VENTILATION OPENING (27"
MODELS)
A minimum of 120 square inches of opening, equally
divided at top and bottom, is required. Air openings are
required to be unobstructed when a door is installed. A
Iouvered door with equivalent air openings for the full
length of the door is acceptable.
27" Model
z: t::z::
Sq.In.
Mli i o%.,n.
When louvers or registers are placed in door openings,
the free air openings of the louvers or registers must
equal 120 square inches.
DOOR VENTILATION OPENING (24"
MODELS)
A minimum of 72 square inches of opening isrequired. Air
openings are required to be unobstructed when a door is
installed. A Iouvered door with equivalent air openings for
the full length of the door is acceptable.
24" Model
!
/o/
H II J'ii'J;4 Sq. In.
I'l HT
When louvers or registers are placed in door openings,
the free air openings of the louvers or registers must
equal 72 square inches.
[Z4]BATHROOM OR BEDROOM INSTALLATION
, The appliance MUST be vented to the outdoors. See
EXHAUSTINFORMATIONsection 6 & 7.
, The installation must conform with local codes or,
in the absence of local codes, with the NATIONAL
ELECTRICALCODE,ANSI/NFPA NO. 70 and NATIONAL
FUELGASCODE,ANSIZ223.
11
Installation instructions
SERVICING
ILWARNING- LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING
CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION
AFTER SERVICING/INSTALLATION.
Forreplacement parts and other information, refer to Owner's Manual for servicing phone numbers.
REGISTERYOUR NEW APPLIANCE TO RECEIVEANY
IIvlPORTANTPRODUCT NOTIFICATIONS.
Please go to www.GEAppliances.com or mail in your
Product Registration Card.
For questions on installation, call: 800.626.2000 (US)or
800-561-3344 (Canada).
12
Instructions d'Installation
ALIMENTATION DE GAZ
. Un rouleau adh6sif pour branchement a gaz de 1/8 in.,
accessible pour des tests de calibrage du branchement,
doit _tre install6 immadiatement en amont du
branchement d'alimentation en gaz_ la s@cheuse.
Contactez I'entreprise de gaz la plus proche si vous avez
des questions sur I'installation du rouleau adh@sif pour
prise.
. Le branchement d'alimentation doit _tre un tuyau
rigide de 1/2in. et 6quip6 avec une valve de fermeture
accessible a 6 ft. de distance, et dans la m_me piece
que la s_cheuse.
Utilisez le compos6 pour tuyau ou le scotch Taflon
appropri_ pour le gaz naturel et LR
Vous devez utiliser avec cette s_cheuse un
branchement flexible en matal list6 comme
branchement ANSI Z21.24 / CSA6.!0. La Iongueur de
ce branchement ne devrait pas excader 3 ft.
Connectez le branchement flexible en matal 5 la
sacheuse et (3I'alimentation en gaz.
Ouvrez la valve de fermeture.
REBRANCHER LE GAZ
Branchement list6 ANSI Z2!.24 / CSA 6.10
24"
BRANCHEMENT
NEUF FLEXIBLE A,
GAZ EN METAL ENTREEA GAZ
DE LA SECHEUSE
/
RETOUR DE
L'APPAREIL
24" & 27"
FLARE
NPT ENTREE
DE L'APPAREIL 27"
SEULEMENT
45 ° COUDE
27" SEULEMENT
ADAPTATEUR
27" SEULEMENT
BRANCHEMENT NEUF
FLEXIBLE A GAZ EN
METAL
ADAPTATEUR
J NPT
1/8" POUR VERIFIER
LA PRESSION DU GAZ A
ENTRANT
VALVE DE FERMETURE
TAILLE DU BRANCHEMENT D'AU
MOINS 1/2"
PLANCHER
N'EST PAS FOURNI
Note: Le connecteur et les raccords sont congus pour 6tre
utilisas uniquement sur I'installation d'origine et ne doivent
pas 6tre rautilisas pour un autre appareil ou a un autre endroit.
Gardez fusae fin de I'adaptateur sans graisse, huile et un produit
d'6tanch6it6.
ATTENTION:Utiliser des adaptateurs, comme i!lustr@. Ecrous
connecteur dolt ne pas 6tre connect6 directement (]filetages.
27"
APPLIQUEZLECOMPOSED'
ETANCHEtTEDESTUYAUTERIESA
L'ADAPTATEURETLEENTREEDUGAZ
DELA SECHEUSE
SERRERLA LIGNE DE BRANCHEMENT A
GAZ FLEXIBLE A L'ENTREEA GAZDE LA
SECHEUSE EN UTILISANT 2 CLES/_MOLETTE
24"
/_ APPLIQUEZ LECOMPOSE
D' ETANCHEITE DES
TUYAUTERIES A L' ENTREEA
GAZ DE LA SECHEUSE
24"
SERRERLA LIGNE DE
BRANCHEMENT A GAZ
FLEXIBLE A L'ENTREE A GAZ DE
LA SECHEUSE EN UTILISANT 2
CLES/_ MOLETTE
24" & 27"
APPLIQUEZ LE
COMPOSED' ETANCHEITE
DESTUYAUTERIES
SURTOUS LES FILETS
DESPARTIESM/_LE
24" & 27"
SERRER TOUS LES CONNECTEURS EN UTILISANT
2 CLt]S A MOLETTE. NE PAS SUR-SERREZ PAS LES
CONNECTEURS DE GAZ.
5
Instructions d'Installation
i15-IREPARATION
AVERTISSEMENT - MARQUEZ TOUS LES FILS AVANT LE DEBRANCHEMENT
LORSQUE VOUS EFFECTUEZ UN CONTROLE POUR REPARATION. LES ERREURS DE
BRANCHEMENT PEUVENT CAUSEES DES PROBLEMES DE FONCTIONEMENT APRES
REPARATION ET D'INSTALLATION.
Pour les pisces de rech(]nge et (]utres inform(]tions, veuillez reporter (]u Manuel de I'Utilis(]teur pour les num6ros de
t616phone du service (]prOsvente.
ENREGISTREZVOTRE NOUVEL APPAREIL POUR q)UE
VOUS RECEVIEZ DESINFORMATIONS IMPORTANTES
SUR LE PRODUIT.
Allez, SVP,sur notre site www.GEAppliances.com ou
envoyez par la poste votre Carte d'inscription du produit.
Pour des questions sur I'install(]tion, composez:
800.626.2000 (E.U.)ou 800.561.:3344(C(]n(]da)
12
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

GE GUD27GSSJ0WW Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI