Installation instructions
CONNECTING THE DRYERTO HOUSEVENT
RIGIDMETALTRANSITIONDUCT
• Forbest dryingperformance,a rigid metaltransition duct is
recommended.
• Rigidmetaltransitionsducts reducethe riskof crushingand
kinking.
UL-LISTEDFLEXIBLEMETAL(SEMI-RIGID}TRANSITIONDUCT
• tf rigid metalduct cannot be used,thenUL-listedflexible metal
(semi-rigid)ducting can beused(KitWX08XZ0077).
• Neverinstallflexible metalduct inwalls,ceilings,floors or
otherenclosedspaces.
Total lengthofflexiblemetal duct shouldnot exceed8 feet
(2.4m).
Formany applications,installingelbowsat boththe dryer
andthe wallishighlyrecommended(seeillustrationsbelow).
Elbowsallowthe dryerto sitcloseto thewallwithout kinking
andor crushingthetransition duct,maximizingdrying
performance.
•Avoidrestingtheductonsharpobjects.
UL-LISTEDFLEXIBLEMETAL(FOIL-TYPE}TRANSITIONDUCT
• tnspecialinstallations,it may benecessarytoconnectthe
dryerto the housevent usinga flexiblemetal (foil-type)duct.
A UL-listedflexiblemetal (foil-type)ductmay beusedONLY
in installationswhererigid metalor flexiblemetal (semi-rigid)
ductingcannot be usedANDwherea4"diametercan be
maintainedthroughout theentirelengthof thetransition
duct.
• tnCanadaandthe UnitedStates,onlythe flexiblemetal(foil-
type)ductsthat complywith the"Outlinefor ClothesDryer
TransitionDuctSubject2158A"shallbeused.
• Neverinstallflexible metalduct inwalls,ceilings,floors or
otherenclosedspaces.
Total lengthofflexiblemetal duct shouldnot exceed8 feet
(2.4m).
•Avoidrestingtheductonsharpobjects.
Forbest dryingperformance:
1.Slideoneend ofthe duct overthe clothesdryeroutlet pipe.
2.Securetheduct with a clamp.
3.With thedryer in itspermanentposition,extendthe duct
to its full length.Allow2"ofductto overlapthe exhaustpipe.
Cutoff and removeexcessduct. Keepthe duct asstraightas
possiblefor maximum airflow.
/4.Securetheduct to the exhaustpipewith theother clamp.
ELBOW HIGHLY
RECOMMENDED
u___LA _t_ S HIGHLY
RECOMMENDED
rssmq
EXCESSLVE
EXHAUST _}LENG_ .................................................EXHAUSTAGALNSTFLEXLBLEDOCRUSHNOT
ALCOVE OR CLOSET INSTALLATION
• tfyour dryerisapprovedfor installationinan alcoveor closet,
itwill bestatedon a labelon the dryerback.
•ThedryerMUSTbeventedto the outdoors.Seethe EXHAUST
INFORMATIONsections3&/4.
• Minimumclearancebetweendryercabinetand adjacentwalls
or other surfacesis:
0 in.eitherside
3 in.front and rear
Minimumverticalspacefrom floorto overheadcabinets,
ceiling,etc.is 52in.
Closetdoorsmustbe Iouveredor otherwiseventilatedand
mustcontaina minimumof60 sq.in.of openareaequally
distributed,tf theclosetcontainsbotha washerand a dryer,
doorsmustcontain a minimumof 120sq.in.ofopen area
equallydistributed.
[-7]BATHROOM OR BEDROOM INSTALLATION
• The dryer MUSTbe vented to the outdoors. See
EXHAUSTINFORMATIONsection 3 & 4.
, The installation must conform with local codes or, inthe
absence of local codes, with the NATIONAL ELECTRICAL
CODE,ANSI/NFPA NO. 70.
5
i-8-_MOBILE OR MANUFACTURED HOME
INSTALLATION
• installationMUSTconformto the MANUFACTUREDHONE
CONSTRUCTION&SAFETYSTANDARD,TITLE24,PART32-80
or,whensuchstandard isnotapplicable,with AMERICAN
NATIONALSTANDARDFORMOBILEHOME,ANSI/NFPANO.
501B.
• ThedryerMUSTbeventedto theoutdoors with the
termination securelyfastenedto the mobilehomestructure.
(SeeEXHAUSTINFORMATIONsection3&/4).
• Thevent MUSTNOTbe terminatedbeneatha mobileor
manufactured home.
• Thevent duct material MUSTBEMETAL.
• Donot usesheet metalscrewsor other fasteningdevices
which extendintothe interiorof theexhaustvent.
• Seesection2for electricalconnectioninformation.