Jenn-Air CCG2523 is a sealed gas cooktop with 5 burners, including a 15,000 BTU burner. It has a countertop cutout of 21 3/16" x 28 5/8" and a BTU rating of 63,000. The cooktop is designed for use with natural gas or LP gas and includes an appliance pressure regulator. It requires a 120-volt, 60-hertz electrical connection and has a maximum depth of cabinets installed above the cooking top of 13".

Jenn-Air CCG2523 is a sealed gas cooktop with 5 burners, including a 15,000 BTU burner. It has a countertop cutout of 21 3/16" x 28 5/8" and a BTU rating of 63,000. The cooktop is designed for use with natural gas or LP gas and includes an appliance pressure regulator. It requires a 120-volt, 60-hertz electrical connection and has a maximum depth of cabinets installed above the cooking top of 13".

SEALEDGAScoorops[ I "JENN-AIR JENN-AIR
CCG2423AND CCG2523 F_
JGC7430AND JGC7536 403WEST
INSTALLATION
MANUAL
IMPORTANT:DimensionsShowninBothInchesandCentimeters.
IMPORTANT:Besuretheappliancebeinginstalledisequippedforthegastobesupplied.Refertoserialplateonundersideofburnerboxforthis
information.Donotattempttoconvertthisapplianceforusewithagasotherthanthetypespecified.
30" MODEL
76.2 ¢m
__, _=_ == '-_"-=--_,Is._,o_ _ _ Z ! i"///
_L'__._._ , '-f \\ _\ /f"_YI/
1%" 27._=n t. \\ I _(
4.21 ¢rn
36" MODEL
329/_sV_e".-/- _ _50.96 cm
S6' _ 82.71 cm // I I _ ,
Er_ . ClearanceI _._A9"_ / _ii_ I
s'_, I _ _ ,_'-_',,.,,;,=----,i._ll.
D ,,L_.I \\IY P0rAI
4._m "=" _/ CUTOUT
IMPORTAN1
DIMENSIONS
ARE
CRITICAL
SPECIALWARNING:Improperinstallation,adjustment,alteration,service,maintenanceoruseofappliance
canresultinseriousinjuryorpropertydamage.
NOTICETOINSTALLER:LEAVETHESEINSTRUCTIONSWITHTHEAPPUANCE.
NOTICETOCONSUMER:RETAINTHESEINSTRUCTIONSFORFUTUREREFERENCE.
8101 P401-60
(o8-ol-oo)
LOCATIONOFYOURJENN-AIRAPPUANCE PREPARATIONOFCOUNTERTOP
Locatethisapplianceawayfromcombustiblematerialssuchaswindow Thecountertopcutoutmustbepreparedaccordingtotheillustrationon
curtainsandcombustiblewalldecorations, page1oftheseinstructions.
Minimumhorizontalclearancebetweentheedgeoftheapplianceand
combustibleconstructionextendingfromthecookingsurfaceto18_(45.72 CAUTION:Cutoutdimensionsarecritical.Dimensionsmustbemeasured
cm)abovethecookingsurfaceis andcutaccuratelytowithin..+.1/16"(.159cm)toensureproperfit.
1"(2.54cm)atrear * Jenn-AJrOver-the-Rangemicrowavem,ens(model#M418andM438)
4"(10.16cm)atsides havebeenlistedbyULforuseoverGasandElectricRanges.When
(Dimensionsapplytoboth30"and36"widemodels) properlyinstalledata minimumheightof66inches(167.64cm)fromthe
floortothetopofthemicrowave,theclearancetothecookingsurfaceat
i .............. _`%',,. thecenterwillbe13-3/4itches(34.93cm).
, I
1. ,,jr 1 ---[
(2_4ore)-.-_; -_ -- " '18' IMPORTANTPREPARATIONSUGGESTIONS
___r/_ _ __. ',45.72,)_ I. Chamferallexposededges ofdscorativelaminatetopreventdamagefromchipping.
2" I . 2. Radiuscornersofcutoutandfileto insuresmoothedgesandprevent
11._'Min. 4...__ _ cemarcracking,
(_.81crn] (tO.t6cm) 3. Roughedges,insidecornerswhichhavenotbeenroundedandforced
FIGURE1 fitscancontributetocrackingofthecountertoplaminate.
4. Countertopmustbesupportedwithin3" (7.62cm)ofcutoat.
INSTALLINGCABINETRYOVERYOUR
JENN-AIRCOOKTOP
A= 30" (76.2 cm) minimum vertical
clearancebetweencookingsurfaceand
constructionabovetheappliance,This
clearancemaybe reducedtonotless
than24inches(60.96cm)byprotecting
theundersideofthecombustiblematerial
or metal cabinetab°vethe co°king! ___ __
surfacewithnotlessthan1/4inch(.635 B
cm)insulatingmillboardcoveredwith !
sheetmetalnotlessthan0.0122inch ,I,
thick* J--[
B= 13" (33.02crn) maximumdepth of
cabinetsinstalledabovecookingtop. FIGURE2
Avoiduseof cabinetsabovecooktopforstoragespaceto eliminate
associatedpotentialhazardssuchasreachingoveropenflames.
INSTALLATIONOFAPPLIANCE CONNECTINGAPPLIANCETOGASSUPPLY
Theinstallationofthisappliancemustconformwithlocalcodesor,inthe ATRAINEDSERVICEMANORGASAPPLIANCEINSTALLERMUST
absenceof localcodas,withthe NationalFuelGas Code,ANSI MAKETHEGASSUPPLYCONNECTION.Leaktastingoltheappliance
Z223.1-LatestEdition,or,inCanada,CAN/CGA-B149InstallationCode, shallbe conductedbytheinstalleraccordingto theinstructions
latestEdition. given.
This appliance,when installed,must be electricallygroundedin 1. IF NOOTHERAPPLIANCEISTOBEINSTALLEDBELOWTHIS
accordancewithlocalcodesor,intheabsenceof localcodes,withthe COOKTOP
NationalElectricalCodeANSI/NFPANo.70-latestEdition,or,inCanada, Jointheappliancepressureregulatorsuppliedwiththisappliancetothe
currentCSAStandardC22.1CanadianElectricalCode,Part1. entrancethreadsoftheGasManifold.Theapplianceregulatorismarked
withadirectionalarrowindicatingcorrectdirectionofgasflow.Ensurethe
Allsupplypiping,exceptas noted,shouldusecommonNationalPipe applianceregulatorisinstalledwiththearrowpointingtowardthegas
Thread(N.P.T.).Forall pipeconnectionsuseanapprovedpipejoint manifoldentrance.Tightentheapplianceregulatorto20 to30ft-lbsof
compoundrasistanttotheactionofLPgas. torque.
CAUTION:WarrantyisvoidonJenn-Airequipmentinstalledotherthanas I IMPORTANT
recommendedbymanufacturer. I Nevertightentomorethan35ft-lbsoftorque.Alwaysuseanapproved
Thisapplianceis designedfor usewiththeappliancegaspressure pipejointcompoundrasistanttotheactionofLPgas.
regulatorsuppliedwiththisappliance.Itmustbeinstalledinthegasway Installtheapplianceinitscountercutout.
aheadofthegasmanifoldentrance.Itispresetforusewithnaturalgasand
mustbeconverted,asdescribedonpage6, forusewithLPgas.(See Makethegasconnectiontotheinletoftheappliancepressureregulator
figures10and11.) with1/2"malepipethreads.
Thisapplianceisdesignedtooperateata pressureof5 inchesofwater Installa manualshut-offvalveinanaccessiblelocationinthegasline
columnonnaturalgasor,if convertedforusewithLPgas(propaneor aheadoftheappliancepressureregulatorandexternaltothisappliaocefor
butane),10incheswatercolumn.Makesurethisapplianceissuppliedwith thepurposeofturningonorshuttingoffgastotheappliance.
andadjustedforthetypeofgasforwhichitisdesigned.
Makeadditionalpipeconnectionsasnecessaryaheadoftheshut-offvalve
Thisappliancewasadjustedatthefactoryforusewithnaturalgas.If,atany tothegassupplysource.Assureallpipejointconnectionsaregastight.
time,thisapplianceistobeusedwitha differenttypeofgas,allofthe
conversionadjustmentsdescribedonpages5 and7mustbemadebya IMPORTANT
qualifiedservicetechnicianbeforeattemptingtooperatethecooktopon Applyanon-corrosiveleakdetectionfluidtoalljointsandfittingsinthe
thatgas.Naturalgasshouldbesuppliedtotheappliancepressureregulator gasconnectionbetweenthesupplylineshut-offvalveandtherange.
atalinepressurebetween6and14inchesofwatercolumnor,ifconverted Includegasfittingsandjointsintherangeifconnectionsweredisturbed
forIF'gas,between11and14inches, duringinstallation.Checkforleaks!Bubblesappearingaroundfittings
andconnectionswillindicatealeak.Ifaleakappears,turnoffsupplyline
WARNING:Ifthelinepressuresupplyingtheappliancepressure gasshut-offvalve,tightenconnections,turnonthesupplylinegasshut
regulatorexceeds14"W.C.(anygas),anexternalregulatormustbeI offvalve,andretestforleaks.Nevertestforgasleakswithanopen
installedinthegaslineaheadoftheapplianceregulatortoreducetheI flame.
pressureto nomorethan14"W.C.Failuretodothiscanresultin
malfunctionanddamagetotheapplance. ILLUSTRATIVEGAS SUPPLY PIPING
(NOOTHER APPLIANCE BELOWCOOKTOP)
I BURNERBOX
Insurethisapplianceisadjustedforthetypeofgassuppliedtoitandthat _ (REAROFAPPLIANCE)
thegassupplypressuretotheapplianceregulatoriswithintheproper
pressurerange.
I I
If thisisa 36"widemodel,orif itisa 30"widemodelandnoother I I_ MANIFOLD
I_, _ ENTRANCE
applianceisto be installedinthecabinetrybelowit, proceedas
instructedunderparagraphI. _ APPLIANCE
Ifthisisa 30"widemodelanda Jenn-AlrModelW30XXXorW131 __ PRESSURE
ElectricWallOvenistobeinstalledincabinetrybelow,proceedas REGULATOR
instructedunderparagraphII. I
/
Donotremoveprotectivecapfrompipestubatmanifoldentranceuntil _ ALLPIPEJOINTS
readytojoingassupplypipingtoappliance. _ 1/2 N.P.T.
MANUAL
SHUTOFF
NOTE:InCanada,gasutilizationcodasprohibituseofstreetelbows.Use VALVE
standardpipeelbowsandmakemodificationstotheseinstructionsas .j..
necessary.
i
|--
TOGAS
ELBOW INLET
FIGURE3
3
2. IFTHISISA30" WIDECOOKTOPANDAJENN-NR,MODEL
W30XXXORW131,ELECTRICWALLOVENISTOBEINSTALLED
BELOWTHISCOOKTOR
NOTE1:Thisapplianceanditsgasandelectricalsupplysourcesmustbe
installedbeforethewallovenisinstalled,Seeillustration(ElectricalWiring ILLUSTRATNEGASSUPPLYPIPING
tnformahon- page4;figure6)forrecommendedelectricalsupplysource (WALLOVENINSTALLEDBELOW30"COOKTOP)
(ovations.
NOTE2:Itmaybenecessarytoextendgassupplypipingforthisappliance 7 =_'_EReox
intoadjacentunder-countercabinetrywhenawallovenisinstalledbelow j _ (Rz,_oF_a
thisappliance.
Joina 1/2"NPTpipeelbow(locallyavailable)tothemalethreadsatthe I
manifoldentrance.Whenjoined,causetheopenthreadsoftheelbowto
facetowardtheleftsideoftheappliance.Installtheapplianceinkscounter
cutout.
Joina 1/2"NPTpipenippletotheelbowusingapipesectionofsufficient
lengthtoextend,horizontally,beyondtheleftsideofthewalloven.(To I _"¢"
t_="_ [ lr,.N.p.,. ]
accomplishthisitmaybenecessarytoextendthepipesectionintoadjacent I ALL_PEao_xrs
cabinetry.)Joinadditional1/2" NPT elbow(s)and pipenipples,as
necessary,toaccomplishthefollowing:
Jointhe outletof the appliancepressureregulatorsuppliedwiththis
appliancetothemalethreadsofthenewlyinstalledgassupplypiping. __.
InstaUtheapplianceregulatorina locationwhichwillbeaccessiblebeside _N_
orbelowthewalloven.Insuretheapplianceregulatorisinstalledwithits L- _ .,%._
directionalarrowpointinginthedirectionofgasflow.Tightentheappliance ,_FgCO_MA_CROSSSZC'nU_
pROFILE OF WALL OVEN
regulatorto20to30ft-lbsoftorque. FIGURE4
IMPORTANT ]
NevertJghtantomorethan35ft-lbsoftorque.AlwaysuseanapprovedI
pipejointcompoundresistanttotheactionofLPgas. ] Note,regardingFigure4,above:
Forconvenienceinserviceagroundjointunion(notshown:locally
Locateandjoinamanualshut-offvalveinanaccessiblelocationinthegas available)shouldbeincludedinthepipingillustratedinfigure4,in
lineaheadoftheapplianceregulatorandexternaltotheapplianceforthe locationmostpracticedfortheinstallation.Generally,apracticaliccatlor
purposeofturningonorshuttingoffgastotheappliance, isinthe_binetbelowthisappliance,nearthemanifoldentrance,rathe
thaninanadjoiningcabinet.
Makeadditionalpipeconnectionsasnecessaryaheadoftheshut-offvalve Ifthealternativepipingmethodshowninfigure5 is selectedforthe
tothegassupplysource.Assureallpipejointconnectionsaregastight, installation,nogroundjointunionisrequired.(Theflexibleapplianc_
connectorillustratedprovidestheunionjointsnecessaryforservicing.I
IMPORTANT Whenadividingwallispresentanda flexibleconnectorisusediti=
Applyanon-corrosiveleakdetectionfluidtoalljointsandfittingsinthe recommendedforconvenJanse,inbethinstallationandservice,th_
gasconnectionbetweenthesupplylineshut-offvalveandtherange, flexibleconnector,itself,passthroughthedividingwall.Anyflexlbl
includegasfittingsandjointsintherangeifconnectionsweredisturbed connectorusedwiththisappliancemustsatisfyallrequirement
duringinstallation.Checkforleaks!Bubblesappearingaroundfittings statedinthetextaccompanyingfigureS.
andconnectionswillindicatealeak.Ifaleakappears,turnoffsupplyline
'gasshut-offvalve,tightenconnections,turnonthesupplylinegasshut
Ioffvalve,andretestforleaks.Nevertestforgasleakswithanopen
iflame.
ALTERNATIVEPIPINGMETHODSTOCONNECT
APPUANCETOGASSUPPLY
A TRAINEDSERVICEMANORGASAPPLIANCEINSTALLERMUST CAU11ON:Donot_empt toattachtheflexibleconnectordirectlytoan
MAKETHEGASSUPPLYCONNECTION.LeakIastingoftheappliance externalpipethread.Connectionrequiresflareunionadapters.
shallbeconductedbythe installeraccordingto theinstruation8
given. IMPORTANT
Unlessprohibitedbylocalcodesorordinances,anewA.G.A.- Certified, Applya non-corrosiveleakdetectionfluidtoalljointsandfittingsinthe
flexiblemetalapplianceconnectormaybeusedtoconnectthisappliance gasconnectionbetweenthesupplylineshut-offvalveandtherange.
toitsgassupply.Theconnectormusthaveaninternaldiameternotless Includegasfittingsandjointsintherangeifconnectionsweredisturbed
thannominal1/2"NPTpipeandbenomorethan5feetinlength.A1/2" duringinstallation.CheckforleakalBubblesappearingaroundfittings
NPTx 1/2"flareunionadapteris requiredateachendof theflexible andconnectionswillindicatealeak.Ifaleakappears,tumoffsuppiyline
connector,ff a flexibleconnectorisusedassurethatb_h theappliance gasshut-o_1valve,tightenconnections,turnonthesupldylinegasshut
pressureregulatorandmanualshut-offvalvearejoinedsolidlytoother offvalve,andretestfor leaks.Nevertestforgasleakswithanopen
permanenthardpiping(eithergassupplyortheappliancemanifold)soas flame.
tobephysicallystationary.Seaillustrationsbelow:
PRESSURETESTING
ILLUSTRATIVE ALTERNATIVE PIPING Theappliancemustbeisolated#orethegassupplypipingsystemby
closingitsindividualmanualshut-offvalveduringanypressuretestingof
thegassupplypipingsystemattestpressuresequaltoorlessthan1/2
PSIG(3.5kPa).
Thisappliance,as wall as its individualshut-offvalve, mustbe
disconnectedfromthegassupplypipingsystemduringanypressure
testingofthesystemattestpressuresinexcessof1/2PSIG(3.5kPa).
I Whencheckingapplianceregulatorfunction,makecertainpressureof
I t naturalgassupplyis between6 and14 inchesofwatercolumnor,if
e.-..- .._ convertedforLPgas,between11and14inches.
m !
R I
jCalt
I
I
NOAPPL.JANOE _ Guut._
MOUI/11_DBELOW _ vz_
THISCOOKTOP
I
WALLOVENMOUNTED __-_NPTP_
INCABINETRYBELOW
II ] (_
THIS COOK_OP _[!,ml supplypipe)
FIGURE5
ELECTRICALWIRINGINFORMATION
Thisapplianceisequippedwitha groundedtypepowercord.Agrounded and,ifnecessary,throughtheslatssupportingtheshelf.Theclearance
outletmustbeprovided.Itisrecommended,forconvenience,theoutletbe holeshouldbelocatedasnearaspracticaltotherearoftheshelfand
located(withreferencetofigure6)asinAor8,below: (iftheovenismodelW30XXX)asnearaspracticaltotheleftrearcomer.
A. Ifnootherapplianceistobeinstalledbelowthisappliance:within_ther 3. WhenmodelW3OXXXismountedbelowthisappliance,andifthepower
theshadedareaorthecrosshatchedareashowninfigure6. outletforthisapplianceistobelocatedinthecrosshatchedareaof
figure6, it isrecommendedthepowercordberoutedthroughthe
B. Ifa ModelW30XXXorW131electricovenistobeinstalledbelowthis externalverticalclearancechannelattheleftrearoftheoven.The
appliance,either: channel'scrosssectionisapproximately4.2"x2.25"(10.7x5.7cm),
1. withintheorosshatchedareaoffigure6,or, extendingthefullheightoftheoven.(ModelW131providesa similar,
2. withinanadjacentcabinet, butlarger,vetticalchannelnearthecenterofthemainbackoftheoven.)
Iftheoutletistobemountedineithera leftorrightadjacentcabinet,a
clearancehole,asdescribedabove,mustbeprovidedinthedividingwall
betweenthecabinets.Figure4;page3, illustratesa typical(leftside)
I dividingwall.Theclearancehole(notshowninfigure4)canbelocatedas
isconvenientinthisleftwallorinthecorrespondingrightwall.
91.44crn In planninganyinstallation,notethatthefreelengthofthisappliance's
I powercord,extendingbeyonda point3-3/4"(9.53cm)leftofthenominal
centeroftherearwalloftheburnerbox,whenviewedfromthefrontofthe
unit,isapproximately46" (117cm).
cAeiNs'rBO'r'rou T WARNING
FIGURE6 ELECTRICAL GROUNDING INSTRUCTIONS
DimenalonA: THIS APPLIANCEIS EQUIPPEDWITH A THREE PRONG
GROUNDINGPLUGFOR YOURPROTECTIONAGAINSTSHOCK
W30XXX:5-1/2"(13.97cm) HAZARDAND SHOULDBE PLUGGEDDIRECTLYINTO A
Wt31:4"(tO.16cm) PROPERLYGROUNDEDRECEPTACLE.DO NOT CUT OR
REMOVETHEGROUNDINGPRONGFROMTHISPLUG. i
Ifawallovenistobeinstalledbelowthisapplianceandthecounterunit's
outletistobemountedwithinthecrosshatchedareaoffigure6:
WARNING
I
1.The cabinet'slowerfrontpanel,belowthe oven,mustbemade ]
removableforaccesstotheoutlet.
!
THIS APPUANCEMUST BE DISCONNECTEDFROM ITS]
2. Aclearanceholeforthepowercord'splug(1-1/4"(3.18cm)diais ELECTRICALSUPPLYAT THE WALL RECEPTACLEBEFORE]
recommended)mustbeprovidedthroughtheoven'sfloorsupportshelf SERVICINGTHEAPPLIANCE.
CONVERTINGAPPLIANCEFORUSE INSTALLATIONOFLPORIFICESPUDS
WITH LP GAS 4 BURNER MODEL (30" WIDE)
WARNING
PropaneconversionistobeperformedbyaJENN-AIRAUTHORIZED
SERVICER(or otherqualifiedagency)in accordancewiththe
manufacturer'sinstructionsandallcodesandrequirementsofthe
authorityhavingjurisdiction.Failuretofollowinstructionscouldresultin
seriousinjuryorpropertydamage.Thequalifiedagencyperformingthis
workassumesresponsibilityforthisconversion.
WARNING
Electricalpowerandgasmustbeturnedoffpriorto
conversion. I _ O (_)
Thisappliancewasadjustedatthefactoryforusewithnaturalgas.To _ O (_
convertitforusewithLPgas(propaneorbutane),eachofthefollowing
modificationsmustbeperformed: _T _Z19-,O-O
A. Replaceallorificespuds
Step1: Removethegratesandburnerheads.
Step2: Removealuminumventuritube. FIGURE8
Step3: Trimasmallpieceofmaskingtapetothesizeofadimeand
a_fixitovertheendofa 5/16"nutdriver. 5 BURNER MODEL (36"WIDE)
Step4: Firmlypressthenutdriverovertheorificespud(figure7)and _ f..l---._-__ /,--"'_--_
loosenspudby turningcounterclockwise.Carefullylift nut / ,_--J.___\
driveroutofburnerthroat.Odficespudshouldbecapturedin
therecess.Repeatthisstepforeachburner.
REMOVAL OF ORIRCE SPUD
o
FIGURE9
Step6: Withthemaskingtapestillin placeintherecessofthenut
FIGURE7 driver,pressanLPorificespudintotherecesssothatitis
snuglycaptured.
Step5: LocatetheLPorificespudpackettapedtotheundersideoftheStep7:Carefullyinstalltheorificespudintheappropriatebumerthroat
byturningclockwisetotighten.Tightentoatorqueof15to20
burnerbox.Thespudshavesmallnumbersstampedonthe inch-lbs.
side.Thisnumbercodestheorificediameteranditscorrect
burnerlocation.ThefollowingillustrationsshowcorrectLP Step8: Replacecylindricalaluminumventuritubes.Replaceburner
orificespudlocationfor 4 burnerand5 burnermodels, headsandgrates.Indexeachgratetoitsburnerpan.
respectively. Step9: Savetheorificesremovedfromtheapplianceforfutureuse.
B. Invertmp Inappliancepresaureregulator
(Seefigures10and11.) 3. Insertaslender,thin-bladescrewdriverintotherecessatcenterof
Withtheapplianceinstalled,theapplienceregulatorshouldbelocated valvesternendengagebladewithslotinadjustingscrew.
asshowninfigure3or4.Identifythetypeofapplianceregulatoronthe 4. Turncenterstemadjustingscrewtosetflamesize.
unitandfollowtheinstructionsintheappropriateillustration. ... clockwisetoreduce
... counterclockwisetoincrease
CONVERSION OF MAX1TROLAPPLIANCE 5.Replacecontrolknobwhenadjustmentiscompleted.
PRESSUREREGULATOR
Properadjustmentwillproducea stable,steadyblueflameofminimum
APPLYDO_IWN_ size.Thefinaladjustmentshouldbecheckedbyturningknobfromhighto
RN_RPRESSURE
ATDISCED6ESTO lOWsever_timeswithoutextinguishingtheflame.
CO_IVERTE APPLYSI_'A_ _w.,v Thisadjustment,atlowsetting,willautomaticaJlyprovidetheproperflame
¢/# _ sizeatmediumsetting.
J
fJqqPTORB_OVERN
PiN,j. CL_j RK_ICAP
_ COUNTERCLOCk3NISE
TOINCREASEFLAME
SIZE
CLOCk3NISE
REDUCE
FLAMESIZE
FIGURE10
..""'-1 [----_ ..WLVE
CONVERSIONPRESSUREOFHARPER-WYMANREGULAToRAPPUANCE _ :_:,_u
FIGURE12
AfterConversionStepsA, B andC havebeencornpleted,checkthe
appearanceofeachburner'sflameattheHiandLosettingsagainstfigure
13.Iftheflamesappeartoo(argeortoosmall,revieweachsteptomake
sureitwascompletedcorrectly.
_ FLAMEAPPEARANCEATHIANDLO
NaturalSetting _LP ,Setting =_"
FIGURE11
C, LOWFlameAdjustment _ (__
(Seefigure12.) L, , o,,, ,,,,.,
Thisapplianceisshippedfromthefactorywithlowandmediumflame
settingsadjustedforusewithnatura)gas.Iffurtheradjustmentis o,
necessary,ortoreadjustforusewithLP,proceedasfollows:
1, Lightburnerandsetcontrolknowforlowflame.
2. Removecontrolknobfromvalvestem. _,["/ "_
HI
CAUTION:NEVERUSEAMETALBLADETOPRYKNOBOFF.IF
KNOBCANNOTBEEASILYREMOVED,TUCKTHEFOLDSOFA
CLOTHDISHTOWELUNDERTHEKNOBANDPULLTHETOWEL ow FIGURE13
UPWARDWITHSTEADY,EVENPRESSURE.
TOCONVERTAPPLIANCEFORUSEWITH INSTALLATIONOFNATURALGAS
NATURALGAS ORIFICESPUDS
WARNING I 4 BURNER MODEL
J
Electricalpowerandgasmustbeturnedoffpriorto
conversion.
If thisappliancehasbeenconvertedforusewithLPgas,eachofthe
followingmodificationsmustbeperformedtoconverttheunitbackto
naturalgas.
A. Replaceallorificespuds
PerformSteps1through4onpage5.
ForStep5:Locatethecoloredbrassnaturalgasorificespudsthatwere
originallyinstalledinthisappliancebeforeitsconversionforusewithLP
gas.Observethecolorofeachofthespudsandnotethecorrectburner (_ (_
locationforeachspudasshowninfigures14and15. _ (_ (_
CompleteSteps6through9 onpage5tocompletetheinstallationof
naturalgasmainspudsintheircorrectlocations. _ ,,RT_2_,,-,9_-.0
Savetheorificesremovedfromtheapplianceforfutureuse.Theywill //
beneededifthisapplianceisagainconvertedforusewithLPgas.
B.Invertcapinapplianceprassumregulator. FIGURE14
(Seefigures10and11.)
Withtheapplianceinstalledtheapplianceregulatorshouldbelocated 5 BURNER MODEL(36"WIDE)
asshownin eitherfigure3 orfigure4 (page3).Identifythetypeof
applianceregulatorandfollowtheinstructionsin theappropriate
illustration.
C.Adjustlowflameasinstructedonpage6 itemC. k
AfterStepsA,BandChavebeencompleted,checktheappearanceof
eachburner'sflameattheHiandLosettingsagainstfigure13.Ifthe
flamesappeartoo largeor too small,makesureall stepswere
completedcorrectly.
_RTt_21W-993-_ (_
FIGURE15
BURNERIGNITIONANDAUTO-REIGNITION TOPGRATEREPLACEMENT
Thisapplianceisequippedforelectronicauto-raignitionbymeansofa Thetopgratesonthiscooktophaveundersideprojectionlugsdesigned
sparkigniterlocatedattherearofeachburner.Theburnersaredesigned nestinmatchingdepressionsinthesplllnvertrays.Duringgratepleceme
tolightatanyvaJverotationthatadmitssufficientgesflowtosupportaflame elwayspesitiongratestomakethisengagement.Correctindexingofgrat_
andtoautomaticallyrelightfollowinga lessofflameduetoadraftorother aboveburnerportswillpreservethegrates'appearanceandhelpassut
adversecondition.Thisfeatureisprovidedasa convenienceandis not longlife.
intendedasasafetyfeature.
CAUTION:Neverusea metalbladeto pryoffa controlknob.Ifa knob
cannotbeeasilyremovedtuckthefoldsofa clothdishtowelunderand
aroundtheknobandpullthetowelupwardwithsteadyevenpressure.
CAUTION:Nevercovercontrolknobsorsurroundingcontrolsurfacewith
utensils,towels,orotherobjects.Neverobstructfreeairpassagepastthe
controlknobs.Theknobopeningshavebeensizedtoproperlycontrolair
entrytotheinterioroftheapplianceduringoperation.
This appliancehas no air shutters.Primaryair adjustmentsare
unnecessary.Theburnersaredesignedtoprovideoptimumaer_ionforall
gaseswithoutair shutters.Whenoperatingproperty,burnersshould
produceclearlydefined,evenblueflames.Iftheflameshaveyellowtipsor
arehazyandotherwiseappeartohaveinsufficientair,obtaintheservices
ofa qualifiedservicetechnician.
Specifiedinputr=esareasshowninfigures16and17,below.
REQUIREDADJUSTMENTSATTIME
4BURNERMODEL OF INSTALLATION
Theinstail=ienofthisappliancemustconformwithIo_ codes,orinthe
E_ _ absenceoflecelcodes,withthelatesteditionoftheNationalFuelGas
CodeANSIZ223.1USAor currentCAN/CGA-Bf49INSTALLATION
CODE.
FIGURE16 [] ThisappliancewasmanufacturedforusewithNaturalGas.IfLPgas
isthefuelofchoice,followtheconversiontoLPprocedurefoundinthe
installationinstructions.
BURNER INPUTRATES- NATURALGAS(BTU/HR)
LOCATION Hi Lo [] Testallexternalconnectionsforgasleaks.Nevertestforgasleaks
RightFront 12,000 1,500 withanopenflame.
RightRear 9,100 1,050
LeftFront 6,500 830 [] Testallelectricalconnections.
LeftRear 10,500 1,500
5BURNERMODEL
FIGURE17
BURNER INPUTRATES.NATURALGAS(BTU/I'IR)
LOCATION Hi Lo
RightFront 12,000 1,5_
RightRear 9,100 1,050
Center 6,500 830
LeftFront 9,100 1,050
LeftRear 10,500 1,500
f0
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10

Jenn-Air CCG2523 User manual

Category
Cookers
Type
User manual
This manual is also suitable for

Jenn-Air CCG2523 is a sealed gas cooktop with 5 burners, including a 15,000 BTU burner. It has a countertop cutout of 21 3/16" x 28 5/8" and a BTU rating of 63,000. The cooktop is designed for use with natural gas or LP gas and includes an appliance pressure regulator. It requires a 120-volt, 60-hertz electrical connection and has a maximum depth of cabinets installed above the cooking top of 13".

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI