Hologic SecurViewDX-RT 10.1.2 User guide

Type
User guide

Hologic SecurViewDX-RT 10.1.2 is an advanced medical imaging workstation that provides comprehensive tools for visualizing and analyzing medical images. With its latest version 10.1.2, the workstation offers enhanced capabilities for breast imaging.

Key features of Hologic SecurViewDX-RT 10.1.2 include:

  • Focus Mode: Easily visualize the correlation between a region of interest in a synthesized 2D image and the most representative reconstructed slice. This feature is particularly useful for tomosynthesis images, allowing for more precise analysis.
  • Improved Image Quality: The workstation utilizes advanced image processing algorithms to deliver high-quality images with enhanced clarity and detail. This enables more accurate diagnoses and reduces the need for additional imaging studies.

Hologic SecurViewDX-RT 10.1.2 is an advanced medical imaging workstation that provides comprehensive tools for visualizing and analyzing medical images. With its latest version 10.1.2, the workstation offers enhanced capabilities for breast imaging.

Key features of Hologic SecurViewDX-RT 10.1.2 include:

  • Focus Mode: Easily visualize the correlation between a region of interest in a synthesized 2D image and the most representative reconstructed slice. This feature is particularly useful for tomosynthesis images, allowing for more precise analysis.
  • Improved Image Quality: The workstation utilizes advanced image processing algorithms to deliver high-quality images with enhanced clarity and detail. This enables more accurate diagnoses and reduces the need for additional imaging studies.
SecurView
®
DX/RT Workstation User Guide Addendum
Using Focus Mode
MAN-05701-002 Revision 001, July 2018 Hologic, Inc. Page 1 of 2
36 Apple Ridge Road, Danbury, CT 06810 USA 800.447.1856
© 2018 Hologic, Inc. The information contained in this document is proprietary. Unauthorized distribution is prohibited.
Using Focus Mode
ThisaddendumappliestoSecurViewversions10.1.2andlater.Placethisdocumentwith
yourSecurViewDX/RTWorkstationUserGuideforfuturereference.
InSecurViewversions10.1.2andlater,Focusmodecanbeusedtoeasilyvisualizethe
correlationfromaregionofinterestinaHologicsynthesized2D(Intelligent2D™orC
View™)imagetothemostrepresentativereconstructedslice.Focusmodeisavailablein
SingleandDoubletiling.
Note
TheFocusbuttonisdisplayedinthetilewiththesynthesized2Dimageonly
whenthesynthesized2Dimageandthecorrespondingreconstructedslices
hangsidebyside.InDoubletilingtheyneedtohanginadjacenttilesonthe
leftorrightside.
Note
TheFocusbuttonisdisplayedevenifʹOmitTomosynthesistoolsʹis
configuredforthetile.(FormoreinformationonʹOmitTomosynthesistoolsʹ,
seetheSecurViewDX/RTWorkstationUserGuide.)
TouseFocus:
Focus
1. ClickFocusinthetiledisplayingthesynthesized2Dimageorpressthe[V]keyon
thekeyboardtoactivateFocusmodeforthetile.Thepointerchangestoacrosshair
toindicateFocusmodeisactive.
Note
FocusmodeisonlyactiveinthetileinwhichtheFocusbuttonisclicked.
Note
Focusmoderemainsactiveuntildeactivated(seestep3).ToapplyFocusina
singleinstancewithoutactivatingthefeature,pressandhold[CTRL]onthe
keyboardwhileclickingtheleftmousebuttoninthesynthesized2Dimage.
2. Clickonaregionofinterestwithinthesynthesized2Dimage.Theassociated
reconstructedslicetileswitchestothemostrepresentativeslice.
Note
IftheFocusdataiscorrupt,thedisplayedslicemaynotbethemost
representativeslice.
a. Whenthepointerisinthetilewiththesynthesized2Dimage,scrolling(for
example,usingthescrollwheel)isappliedtothetilewiththecorresponding
reconstructedslices.
b. IfCinemodeisappliedtoafocusedreconstructedslice,LocalCinemodeis
appliedautomaticallywiththefocusedreconstructedsliceasthecenterslice.
SecurView® DX/RT Workstation User Guide Addendum
Using Focus Mode
MAN-05701-002 Revision 001, July 2018 Hologic, Inc. Page 2 of 2
36 Apple Ridge Road, Danbury, CT 06810 USA 800.447.1856
© 2018 Hologic, Inc. The information contained in this document is proprietary. Unauthorized distribution is prohibited.
Note
ClickingwithinaMagnifierdoesnotactivateFocusmode.
Note
Whenclickingontheimagebackground,nocorrespondingfocused
reconstructedsliceisassigned.Thecurrentlydisplayedreconstructedslice
willnotchange.
3. ClickFocusinthetiledisplayingthesynthesized2Dimageorpressthe[V]keyto
deactivateFocusmodeforthetile.
Note
Focusmodeisnotdeactivatedbyselectinganotherimageevaluationtool.
Note
Focusmodeisautomaticallydeactivatedwhenthecurrenthangingchanges,
forexample,bygoingtothenextorpreviousstepintheReportFlow,
manuallydraggingadifferentimagefromtheMammoNavigator,switching
toadifferentimageineithertileusingtheTomosynthesisNavigation
buttons,orclickingapredefinedhangingbutton.
  • Page 1 1
  • Page 2 2

Hologic SecurViewDX-RT 10.1.2 User guide

Type
User guide

Hologic SecurViewDX-RT 10.1.2 is an advanced medical imaging workstation that provides comprehensive tools for visualizing and analyzing medical images. With its latest version 10.1.2, the workstation offers enhanced capabilities for breast imaging.

Key features of Hologic SecurViewDX-RT 10.1.2 include:

  • Focus Mode: Easily visualize the correlation between a region of interest in a synthesized 2D image and the most representative reconstructed slice. This feature is particularly useful for tomosynthesis images, allowing for more precise analysis.
  • Improved Image Quality: The workstation utilizes advanced image processing algorithms to deliver high-quality images with enhanced clarity and detail. This enables more accurate diagnoses and reduces the need for additional imaging studies.