RAB EZPAN Operating instructions

  • Hello! I've reviewed the installation instructions for the RAB EZPAN FA series LED panels, including the 1x4, 2x2, and 2x4 models. This document covers how to install these panels in recessed ceilings, including wiring, dimming, and battery backup options. I understand the key features, such as adjustable wattage and color temperatures, and I'm ready to answer any questions you have about installing or using these LED panels.
  • What type of ceilings are these fixtures suitable for?
    Is this fixture suitable for damp locations?
    Can the fixture be dimmed?
    Can the wattage and color temperature be adjusted?
INSTRUCTIONS
EZPAN® FA 1x4, 2x2, 2x4 INSTALLATION
RAB Lighting is committed to creating high-quality, aordable, well-designed and energy-ecient LED lighting and controls that make it easy for electricians to install
and end users to save energy. We’d love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]
IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.



WARNING: Make certain power is OFF before installing or maintaining xture.
WARNING: Risk of re or electric shock. Suitable for damp locations.
WARNING: Suitable for 9/16” or 15/16” at tee grid in both insulated ceilings and non-insulated ceilings. Access above
ceiling required.
WARNING: Do not handle energized xture when hands are wet, when standing on wet or damp surfaces, or in water.
WARNING: Vapor barrier must be suitable for 90° C.
WARNING: Fixture to be independently supported to building structure.





 Grid Clips 

  Fixture
Tee-Grid Bar 
Fixture Tee-Grid Bar
 
FixtureSupport Wires (supplied by
others) Grid Clip Hole
 Splice BoxAccess
Plate
 Access Plate Screw Access Plate.
Conduit KnockoutsAccess Plate

(Fig. 4)
 
Splice Box

 WARNING: To prevent wiring damage or
abrasion, do not expose wiring to edges of sheet metal or
other sharp objects.
 Access PlateAccess Plate Screw.
EZPAN FA 1x4 EZPAN FA 2x2 EZPAN FA 2x4



 Access Plate Conduit Knockouts
Fixture
Grid Clip Tee-Grid Bar
Access Plate Screw
Splice Box
Fixture
Firmly bend Grid
Clips up and out
Grid Clip Hole
Grid Clip
Power Feed
Support Wire (supplied by others)
1.6”
INSTRUCTIONS
EZPAN® FA 1x4, 2x2, 2x4 INSTALLATION
RAB Lighting is committed to creating high-quality, aordable, well-designed and energy-ecient LED lighting and controls that make it easy for electricians to install
and end users to save energy. Wed love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]




.
 LINE
  COMMON 
 GROUND 
 
  (or gray)
NOTE: Do not connect DIM V+ (purple)/ DIM V- (pink/gray) to line
voltage or supply ground.


(1X4, 2X2)(40W (2X4)
  Selector Switches 
 

 
Silicone Cover

Selector Switches
Silicone Covers

 

 

CAUTION: Be sure xture temperature is cool enough to touch.
Do not clean or maintain while xture is energized.
 

 
PINK (or GRAY)
LIGHT
FIXTURE
Vaux 12V
YELLOW
GROUND
GROUND
( - ) DIM V
( + ) DIM V
COMMON
LINE BLACK
WHITE
PURPLE
INSTRUCTIONS
EZPAN® FA 1x4, 2x2, 2x4 INSTALLATION
RAB Lighting is committed to creating high-quality, aordable, well-designed and energy-ecient LED lighting and controls that make it easy for electricians to install
and end users to save energy. Wed love to hear your comments. Please call the Marketing Department at 888-RAB-1000 or email: [email protected]
EZPAN FA-IN-1021 RAB WARRANTY: RAB’s warranty is subject to all terms and conditions found at rablighting.com/warranty
 


CAUTION: FOR BATTERY BACKUP FIXTURE. 
BATTERY. 

BATTERY
 (Fig. 6)
NOTE: 



CAUTION: 




 

 

 

 
 

 
Note: These instructions do not cover all details or variations in
equipment nor do they provide for every possible situation during
installation, operation or maintenance.
 UNSWITCHED HOT HOT AC
 UNSWITCHED UNSWITCHED
SWITCHED
 SWITCHEDSWITCHED HOT

 (or gray)
 DIMDIM
GROUND
 
 
BATTERY.
 


 



 
BATTERY
 
(internal battery)


 

LIGHT
FIXTURE
INSIDE FIXTURE
BATTERY
Pink (or Gray)/DIM–
Black/Switched Line
Green/Ground
White/Neutral
Black/Unswitched Line
Purple/DIM+
BACKUP
DRIVER
BATTERY
CONNECTOR:
CONNECT
ONLY AFTER
AC SUPPLY
POWER IS
CONNECTED

Easy Answers
rablighting.com
Visit our website for product info
Tech Help Line
Call our experts: 888 722-1000
e-mail
Answered promptly - [email protected]
Free Lighting Layouts
Answered online or by request
© 2021 RAB LIGHTING Inc.

73665-RAB

Welcome
1 (844) LIGHTCLOUD
or 1 (844) 544-4825
WE RE HE R E TO HE LP:
Luminaire Sensor
Hello
PART NUMBER
Edge: LCLCSENSE/EG
Standard: LCLCSENSE/SH
High Bay: LCLCSENSE/HB
INPUT
5VDC
OPERATING TEMPERATURE
-40°C to 40°C
DIMENSIONS
Ceiling Mount: 2.25”W x 1.74”H x 2.25”D
Edge: 1.30”W x 0.99”H x 2.34”D
Standard: 1.20”W x 1.05”H x 1.20”D
High Bay: 1.75”W x 1.08”H x 1.75”D
SENSOR COVERAGE
Edge: 20 ft. diameter at 9 ft.
Standard: 30 ft. diameter at 9 ft.
High Bay: 40 ft. diameter at 30 ft.
50 ft. diameter at 45 ft.
MOUNTING HEIGHT
Edge: 8 to 12 ft.
Standard: 8 to 12 ft.
High Bay: 25 to 45 ft.
CONNECTOR
RJ9 (RJ22)
RATING
Standard and High Bay: IP66
Specications
The Lightcloud Luminaire Sensor is a dual-technology motion detector
and closed loop daylight harvester that can switch and dim both local
and remote circuits. The Luminaire Sensor requires a compatible
lightcloud controller or fixture.
Setup & Installation
1Remove Bezel
Twist counter-clockwise.
2Prepare Mounting Hole
Use knockout or cut hole for sensor.
Holes have +/- 1/8 in. tolerance.
STANDARD
7/8 IN. DIAMETER
CEILING MOUNT
2 IN. DIAMETER
HIGH BAY
1 IN. DIAMETER
3Installing the Sensor
Ceiling Mount
Place gasket and sensor into
ceiling mount.
Screw bezel onto sensor from
below ceiling.
Fold up tabs on ceiling
mount and push through
hole cut in step 2.
GASKET
SENSOR
BEZEL
3a
3b In-Fixture Mounting
Place gasket and sensor through the hole cut in step 2.
Screw bezel onto sensor.
SENSOR
GASKET
BEZEL
3Connect the Sensor
Controller: Use the adapter to
connect the sensor to the
Controller.
Lightcloud Driver: Plug the sensor
into the sensor port on the driver.
SENSOR
Grey Wire Short, Grey Wire
Female to Female
RJ9 (RJ22)
CONTROLLER
ADAPTER
SENSOR
Grey Wire
LIGHTCLOUD DRIVER
If a longer cable is needed, an extension cable (RJ9) up to 10 ft. can be used.
1 (844) LIGHTCLOUD
WE RE H ERE TO HEL P:
or 1 (844) 544-4825
Conguration
© RAB Lighting, Inc. 2020
170 Ludlow Ave., Northvale, NJ 07647
Custom manufactured in China
To configure the Luminaire Sensor, please login to the Web App at
control.lightcloud.com or call Lightcloud Support at 1(844) Lightcloud.
For additional startup information, please visit lightcloud.com/start.
Sensor Coverage
15’ 7.5’ 7.5’ 15’
30’
9’
0’
0’
7.5’
7.5’
15’
15’
STANDARDEDGE
20’ 14’ 14’ 20’
40’
30’
0’
0’
14’
14’
20’
20’
HIGH BAY
SIDE VIEWTOP VIEW
10’ 7.5’ 7.5’ 10’
20’
9’
0’
0’
7.5’
7.5’
15’
15’
/