Daniel 3410 Series Gas Ultrasonic Flow Meters Owner's manual

Type
Owner's manual
Maintenance and Troubleshooting manual
P/N 3-9000-791, Rev DB
February 2020
Daniel
3410 Series Gas Ultrasonic Flow
meters
Models 3415, 3416 and 3417
2
Flow Lifecycle Services for Daniel products
Location Telephone number Fax number
North America/Latin America +1.713.467.6000 +1.713.827.4805
Flow Lifecycle Services for Daniel products +1.713.827.6314 +1.713.827.6312
USA (toll free) +1.888.356.9001 +1.713.827.3380
Asia Pacific (Republic of Singapore) +65.6777.8211 +65.6777.0947.0743
Europe (Stirling Scotland, UK) +44 (0)1786.433400 +44 (0)1786.433401
Middle East Africa (Dubai, UAE) +971 4 8118100 +971 4 8865465
Daniel Measurement and Control, Inc. (Headquarters)
11100 Brittmoore Park Drive
Houston, TX 77041 USA
http://www.emerson.com
Email
Customer Service: [email protected]
Customer Support: [email protected]
Field Lifecycle Services: [email protected]
Asia-Pacific: [email protected]
Europe: [email protected]
Return Material Authorization (RMA)
A Return Material Authorization (RMA) number must be obtained prior to returning any equipment for any reason. Access and
fill in the RMA form for Daniel products clicking on the link below.
http://go.emersonprocess.com/RMAOnlineForm
3
Signal words and symbols
Pay special attention to the following signal words, safety alert symbols and statements:
Safety alert symbol
This is a safety alert symbol. It is used to alert you to potential physical injury hazards. Obey all safety messages that follow this
symbol to avoid possible injury or death.
DANGER
Danger indicates a hazardous situation which, if not avoided, will result in death or serious injury.
WARNING
Warning indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
Caution indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE
Notice is used to address safety messages or practices not related to personal injury.
Important
Important is a statement the user needs to know and consider.
Tip
Tip provides information or suggestions for improved efficiency or best results.
Note
Note is “general by-the-way” content not essential to the main flow of information.
4
Important safety instructions
Daniel Measurement and Control, Inc. (Daniel) designs, manufactures and tests products to function within specific conditions.
Because these products are sophisticated technical instruments, it is important that the owner and operation personnel must
strictly adhere both to the information printed on the product and to all instructions provided in this manual prior to installation,
operation, and maintenance.
Daniel also urges you to integrate this manual into your training and safety program.
BE SURE ALL PERSONNEL READ AND FOLLOW THE INSTRUCTIONS IN THIS MANUAL AND ALL NOTICES AND PRODUCT WARNINGS.
WARNING
Failure to follow the installation, operation or maintenance instructions for a Daniel product could lead to serious injury or
death from explosion or exposure to dangerous substances.
To reduce the risk:
Comply with all information on the product, in this manual, and in any local and national codes that apply to this product.
Do not allow untrained personnel to work with this product.
Use Daniel parts and work procedures specified in this manual.
Product owners (Purchasers):
Use the correct product for the environment and pressures present. See technical data or product specifications for
limitations. If you are unsure, discuss your needs with your Daniel representative.
Inform and train all personnel in the proper installation, operation, and maintenance of this product.
To ensure safe and proper performance, only informed and trained personnel should install, operate, repair and maintain this
product.
Verify that this is the correct instruction manual for your Daniel product. If this is not the correct documentation, contact
Daniel at 1-713-827-6314. You may also download the correct manual from: https://www.emerson.com/en-us/automation/
daniel.
Save this instruction manual for future reference.
If you resell or transfer this product, it is your responsibility to forward this instruction manual along with the product to the
new owner or transferee.
ALWAYS READ AND FOLLOW THE INSTALLATION, OPERATIONS, MAINTENANCE AND TROUBLESHOOTING MANUAL(S) AND
ALL PRODUCT WARNINGS AND INSTRUCTIONS.
Do not use this equipment for any purpose other than its intended service. This may result in property damage and/or serious
personal injury or death.
5
Product operation (Personnel):
To prevent personal injury, personnel must follow all instructions of this manual prior to and during operation of the product.
Follow all warnings, cautions, and notices marked on, and supplied with, this product.
System should be designed to avoid over pressure conditions or exceeding maximum safe flow rate if meter losses
measurement.
Verify that this is the correct instruction manual for your Daniel product. If this is not the correct documentation, contact
Daniel at 1-713-827-6314. You may also download the correct manual from: https://www.emerson.com/en-us/automation/
daniel.
Read and understand all instructions and operating procedures for this product.
If you do not understand an instruction, or do not feel comfortable following the instructions, contact your Daniel
representative for clarification or assistance.
Install this product as specified in the INSTALLATION section of this manual per applicable local and national codes.
Follow all instructions during the installation, operation, and maintenance of this product.
Connect the product to the appropriate pressure and electrical sources when and where applicable. Never operate meter
above the maximum working pressure stated on the nameplate.
Ensure that all connections to pressure and electrical sources are secure prior to and during equipment operation.
Use only replacement parts specified by Daniel. Unauthorized parts and procedures can affect this product's performance,
safety, and invalidate the warranty. “Look-a-like” substitutions may result in deadly fire, explosion, release of toxic substances
or improper operation.
Save this instruction manual for future reference.
6
Notice
THE CONTENTS OF THIS PUBLICATION ARE PRESENTED FOR INFORMATIONAL PURPOSES ONLY, AND WHILE EVERY EFFORT HAS
BEEN MADE TO ENSURE THEIR ACCURACY, THEY ARE NOT TO BE CONSTRUED AS WARRANTIES OR GUARANTEES, EXPRESSED OR
IMPLIED, REGARDING THE PRODUCTS OR SERVICES DESCRIBED HEREIN OR THEIR USE OR APPLICABILITY. ALL SALES ARE
GOVERNED BY DANIEL'S TERMS AND CONDITIONS, WHICH ARE AVAILABLE UPON REQUEST. WE RESERVE THE RIGHT TO MODIFY
OR IMPROVE THE DESIGNS OR SPECIFICATIONS OF SUCH PRODUCTS AT ANY TIME.
DANIEL DOES NOT ASSUME RESPONSIBILITY FOR THE SELECTION, USE OR MAINTENANCE OF ANY PRODUCT. RESPONSIBILITY FOR
PROPER SELECTION, USE AND MAINTENANCE OF ANY DANIEL PRODUCT REMAINS SOLELY WITH THE PURCHASER AND END-USER.
TO THE BEST OF DANIEL'S KNOWLEDGE THE INFORMATION HEREIN IS COMPLETE AND ACCURATE. DANIEL MAKES NO
WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE WITH RESPECT TO THIS MANUAL AND, IN NO EVENT, SHALL DANIEL BE LIABLE FOR ANY INCIDENTAL,
PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES INCLUDING, BUT NOT LIMITED TO, LOSS OF PRODUCTION, LOSS OF PROFITS,
LOSS OF REVENUE OR USE AND COSTS INCURRED INCLUDING WITHOUT LIMITATION FOR CAPITAL, FUEL AND POWER, AND
CLAIMS OF THIRD PARTIES.
PRODUCT NAMES USED HEREIN ARE FOR MANUFACTURER OR SUPPLIER IDENTIFICATION ONLY AND MAY BE TRADEMARKS/
REGISTERED TRADEMARKS OF THESE COMPANIES.
7
Warranty and Limitations
1. LIMITED WARRANTY: Subject to the limitations contained in Section 2 herein, Daniel Measurement & Control, Inc. (“Daniel”)
warrants that the licensed firmware embodied in the Goods will execute the programming instructions provided by Daniel, and
that the Goods manufactured by Daniel will be free from defects in materials or workmanship under normal use and care and
Services will be performed by trained personnel using proper equipment and instrumentation for the particular Service provided.
The foregoing warranties will apply until the expiration of the applicable warranty period. Goods are warranted for twelve (12)
months from the date of initial installation or eighteen (18) months from the date of shipment by Daniel, whichever period expires
first. Consumables and Services are warranted for a period of 90 days from the date of shipment or completion of the Services.
Products purchased by Daniel from a third party for resale to Buyer (“Resale Products”) shall carry only the warranty extended by
the original manufacturer. Buyer agrees that Daniel has no liability for Resale Products beyond making a reasonable commercial
effort to arrange for procurement and shipping of the Resale Products. If Buyer discovers any warranty defects and notifies Daniel
thereof in writing during the applicable warranty period, Daniel shall, at its option, correct any errors that are found by Daniel in
the firmware or Services or repair or replace F.O.B. point of manufacture that portion of the Goods or firmware found by Daniel to
be defective, or refund the purchase price of the defective portion of the Goods/Services. All replacements or repairs necessitated
by inadequate maintenance, normal wear and usage, unsuitable power sources or environmental conditions, accident, misuse,
improper installation, modification, repair, use of unauthorized replacement parts, storage or handling, or any other cause not the
fault of Daniel are not covered by this limited warranty, and shall be at Buyer's expense. Daniel shall not be obligated to pay any
costs or charges incurred by Buyer or any other party except as may be agreed upon in writing in advance by Daniel. All costs of
dismantling, reinstallation and freight and the time and expenses of Daniel's personnel and representatives for site travel and
diagnosis under this warranty clause shall be borne by Buyer unless accepted in writing by Daniel. Goods repaired and parts
replaced by Daniel during the warranty period shall be in warranty for the remainder of the original warranty period or ninety (90)
days, whichever is longer. This limited warranty is the only warranty made by Daniel and can be amended only in a writing signed
by Daniel. THE WARRANTIES AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE. THERE ARE NO REPRESENTATIONS OR
WARRANTIES OF ANY KIND, EXPRESS OR IMPLIED, AS TO MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE OR ANY OTHER
MATTER WITH RESPECT TO ANY OF THE GOODS OR SERVICES. Buyer acknowledges and agrees that corrosion or erosion of
materials is not covered by this warranty.
2. LIMITATION OF REMEDY AND LIABILITY: Daniel shall not be liable for damages caused by delay in performance. The remedies of
Buyer set forth in this agreement are exclusive. In no event, regardless of the form of the claim or cause of action (whether based
in contract, infringement, negligence, strict liability, other tort or otherwise), shall Daniel's liability to Buyer and/or its customers
exceed the price to Buyer of the specific goods manufactured or services provided by Daniel giving rise to the claim or cause of
action. Buyer agrees that in no event shall Daniel's liability to Buyer and/or its customers extend to include incidental,
consequential or punitive damages. The term “consequential damages” shall include, but not be limited to, loss of anticipated
profits, revenue or use and costs incurred including without limitation for capital, fuel and power, and claims of Buyer's customers.
8
Contents
Chapter 1 Maintenance................................................................................................................11
1.1 Precautions for meter maintenance................................................................................................11
1.2 Field hydrostatic pressure testing procedures.................................................................................12
1.3 Routine maintenance..................................................................................................................... 13
Chapter 2 Troubleshooting.......................................................................................................... 19
2.1 Meter status alarms........................................................................................................................19
2.2 Troubleshooting the meter............................................................................................................ 22
2.3 Troubleshoot maintenance log files and trend files.........................................................................41
Chapter 3 Meter repairs............................................................................................................... 45
3.1 Precautions prior to repairs.............................................................................................................45
3.2 T-Slot transducer removal and installation......................................................................................48
3.3 T-Slot transducer holder removal and installation...........................................................................56
3.4 T-200 transducer assembly removal and installation...................................................................... 61
3.5 T-200 transducer capsule assembly removal and installation..........................................................64
3.6 T-200 transducer housing removal and installation........................................................................ 69
3.7 Transducer cable removal and installation......................................................................................71
3.8 Replace the meter electronics........................................................................................................ 78
3.9 Acquisition Module replacement....................................................................................................88
Appendix A Conversion factors....................................................................................................... 95
A.1 Conversion factors per units of measurement................................................................................ 95
A.2 K-Factor and inverse K-Factor conversions......................................................................................96
Appendix B Engineering drawings.................................................................................................. 97
B.1 Daniel 3410 Series Ultrasonic Flow Meter Drawings........................................................................97
Maintenance and Troubleshooting manual Contents
P/N 3-9000-791 February 2020
Maintenance and Troubleshooting manual ix
Contents Maintenance and Troubleshooting manual
February 2020 P/N 3-9000-791
x Models 3415, 3416 and 3417 GUSM
1 Maintenance
1.1 Precautions for meter maintenance
This section includes discussion of the maintenance of Daniel 3410 Series Ultrasonic
Meters.
For reference, you may download the Daniel MeterLink Quick Start Manual from: http://
www.emerson.com/en-us/catalog/measurement-instrumentation/daniel-meterlink.
CAUTION
SURFACE TEMPERATURE HAZARD
The meter body and piping may be extremely hot or cold.
Wear appropriate personal protective equipment when coming in contact with the
meter.
Failure to comply may result in injury.
CAUTION
TRANSPORTATION HAZARD
When moving the meter, do not insert the forks of a forklift into the bore.
Inserting the forks may cause the meter to become unstable, resulting in injury or
damage to the bore and sealing face.
CAUTION
TRIPPING HAZARD
Clear all obstacles or obstructions from the work area when transporting, installing or
removing the meter.
Failure to clear the work area may cause injury to personnel.
Maintenance and Troubleshooting manual Maintenance
P/N 3-9000-791 February 2020
Maintenance and Troubleshooting manual 11
WARNING
CRUSHING HAZARD
Do not remove flange stabilizers.
Attempting to do so could allow the meter to roll, resulting in serious injury or
equipment damage.
A. Flange stabilizers
CAUTION
ESCAPING FLUIDS HAZARD
The purchaser of the meter is responsible for the selection of Daniel components/seals
and materials compatible with the chemical properties of the measurement fluid.
Failure to select suitable meter components/seals may cause escaping fluids, resulting
in injury or equipment damage.
WARNING
HEARING DAMAGE
Wear proper hearing protection before approaching a metering system that is
generating a large amount of audible noise. Obey all facility safety rules.
Failure to comply could result in temporary or permanent hearing loss.
1.2 Field hydrostatic pressure testing procedures
CAUTION
LEAKAGE OR PRESSURE CONTAINING PARTS FAILURE
Use precautions to eliminate hazards to personnel in the event of leakage or failure of
the liquid ultrasonic meter pressure containing parts or failure of the test equipment
and to prevent over-pressurization during the test procedure.
Failure to comply may result in injury to personnel or cause damage to the equipment.
1.2.1
T-Slot transducer assembly and mount
Procedure
1. Slowly vent all line pressure on the 3410 Series Gas Ultrasonic Meter to atmosphere.
2. Disconnect transducer cable from the transducer holder.
Maintenance Maintenance and Troubleshooting manual
February 2020 P/N 3-9000-791
12 Models 3415, 3416 and 3417 GUSM
3. Loosen the T-Slot transducer assembly with a 1 1/4 inch (32 mm) wrench or socket.
Carefully remove the T-Slot transducer assembly.
4. Place a label on the transducer assembly to marks its location. Port locations are
marked on the transducer cable as well as on cast meter housings.
5. Apply a small amount of Nickel antiseize compound (P/N 3-9960-134) to the
threads of the Hydrotest plug from Hydrotest kit and install it into the mount.
Required kit part numbers are listed below.
Model 3415 Quantity 1 x 1-360-01-220
Quantity 1 x 1-360-01-221
Model 3416 Quantity 1 x 1-360-01-220
Quantity 1 x 1-360-01-222
Model 3417 Quantity 2 x 1-360-01-220
6. Repeat Step 3 through Step 5 for the other transducer(s) being careful to note the
location of each transducer in the meter assembly.
7. Run the field hydrostatic test.
8. Reverse the steps above to reinstall the transducers into their appropriate ports.
Before reinstalling the transducer assemblies, ensure the transducer ports, mounts,
and transducer holders are clean and free of debris. Apply a small amount of Nickel
antiseize compound to the outer threads of the transducer holders before installing
them into the mounts.
1.2.2
T-200 transducer assembly
The T-200 transducer assembly has full-metal structure and can remain in place during
field hydrostatic pressure test.
Procedure
1. Leave T-200 transducers installed on the 3410 Series Gas Ultrasonic Meter while the
line is pressurized.
2. Run the field hydrostatic test.
1.3 Routine maintenance
Routine maintenance operations requires adherence to all applicable regulations and laws
and safety training for personnel to perform the maintenance operations. Review your
organization's best practices procedures before performing routine maintenance.
1.3.1
Maintenance logs and reports
To monitor the performance health of the meter, and ensure it is operating within
acceptable specifications, routine diagnostics should be performed. Collecting a
maintenance log gives you a snapshot of the current health of the meter and you can
compare the inspection reports from previously saved logs. Use the Logs/Reports menu
and click Maintenance Logs and Reports. Daniel MeterLink
displays the Maintenance Logs
and Reports dialog box. Choose the time duration, log format and collection rate for the
Maintenance and Troubleshooting manual Maintenance
P/N 3-9000-791 February 2020
Maintenance and Troubleshooting manual 13
output file and click the Start button. You can open the file immediately after it is
generated or view it at a later time. It is recommended that a Maintenance log be
collected after an upset in the system.
In establishing a baseline to be used for the trending of the meter diagnostics, it is very
helpful if a set of log files are collected immediately after the meter has been installed in
the field. Preferably, collect the log files at several velocities within the operating range of
the meter. This helps establish that the flow profile is relatively constant throughout the
meters operating range (except velocities below 3 ft/sec where the profile may vary).
Maintenance log collection
Figure 1-1: Maintenance log collection parameters
Trend maintenance log collection
Merging the results of two or more Maintenance logs into a single file, allows you to build
a historical database of the meter's performance. Trending the logs indicates changes
from the original installation of the meter, or over time. Looking at a single inspection
report, that is either collected monthly or quarterly, can give you an indication of the
meter's health.
Maintenance Maintenance and Troubleshooting manual
February 2020 P/N 3-9000-791
14 Models 3415, 3416 and 3417 GUSM
Figure 1-2: Trend log collection
This is important since many diagnostics change slowly overtime. Trending the
maintenance logs helps identify these changes and makes problems much more obvious
than merely viewing a single inspection report. The Trending feature is integral to Daniel
MeterLink
which allows all important parameters to be trended. Daniel MeterLink
supports trending files in a Microsoft
®
Excel
®
workbook from multiple 3410 Series meter
maintenance logs. Some parameters like gain, signal level,and noise level may show a shift
over time which can be useful in detecting changes in the meter and the installation.
Maintenance logs or Trend files to be trended must all have matching column headings.
This means the logs must be in the same units (i.e. U.S. Customary or Metric), must have
the same pressure type (i.e. gage or absolute), and must have the same time base (1/
second, 1/minute, 1/hour, 1/day). If not, an error message will be displayed stating the
column headings do not match and the file will not be added to the Workbook to trend
list.
Archive log collection
Archive logs may be collected and the options include:
Daily log - generated every 24 hours on the Contract Hour
Hourly log - generated every hour at the top of the hour
Event log - collects the alarm and event log records
Maintenance and Troubleshooting manual Maintenance
P/N 3-9000-791 February 2020
Maintenance and Troubleshooting manual 15
Figure 1-3: Archive log collection parameters
The logs may be collected in a single file or you can choose to collect one type of log. Each
of the Meter Archive logs include the Meter Configuration file.
1.3.2 Pipe cleaning maintenance
WARNING
BURST HAZARD
Before pipeline cleaning and maintenance ("pigging operations"), remove straightening
vanes or flow conditioners.
Failure to comply may cause excessive pressure in the meter system, resulting in death,
serious injury or equipment damage.
Figure 1-4: 3410 Series Gas Ultrasonic Flow Meter with flow conditioner for uni-
directional flow
Figure 1-5: 3410 Series Gas Ultrasonic Flow Meter with flow conditioner for bi-
directional flow
Straightening vanes or flow profilers must be removed during pipeline cleaning
maintenance operations (“pigging operation”). If the meter run is pigged with a flow
conditioner in line, pressure may build up and cause the pipes and flanges to burst and
severely injure personnel. The excessive pressure may damage the meter or the
transducer ports may collect debris which may impede data acquisition and flow
measurement.
1.3.3
Visual inspection
Periodically inspect the meter and meter run for signs of components loosening or seals
leaking. This includes:
Maintenance Maintenance and Troubleshooting manual
February 2020 P/N 3-9000-791
16 Models 3415, 3416 and 3417 GUSM
Procedure
1. Fluids leaking from seals. This could be visually noticed for liquids leaking. It may be
audible for gasses leaking. Ice may also form at a point of a gas leak.
2. Movement of components that should be rigid.
3. Excessive noise due to vibration could be sign of a loose component.
Inspection should be more frequent in systems with a large amount of vibration.
Maintenance and Troubleshooting manual Maintenance
P/N 3-9000-791 February 2020
Maintenance and Troubleshooting manual 17
Maintenance Maintenance and Troubleshooting manual
February 2020 P/N 3-9000-791
18 Models 3415, 3416 and 3417 GUSM
2 Troubleshooting
2.1 Meter status alarms
Run Daniel MeterLink
and open the Meter Monitor (Summary) view to perform a
diagnostics health check.
Figure 2-1: Meter Monitor status alarms
If the meter is measuring flow and operating within the calibration parameters the Meter
Status LED is green. If the Meter Status LED is red, an active alarm exists that requires you
to take corrective action. Click the Check Status button to display the Status Summary
screen. The alarms are shown with the primary causes listed first. Click the question mark,
, next to the alarm to display a help topic related to the alarm and recommended actions
to resolve the issue.
Figure 2-2: Status summary
Maintenance and Troubleshooting manual Troubleshooting
P/N 3-9000-791 February 2020
Maintenance and Troubleshooting manual 19
2.1.1 Check status
Click the Check Status button if any of the LEDs are yellow or red to see more specific
information causing the status alarm. Some alarms do not require an acknowledge and
will clear automatically when the alarm condition goes away. Alarms that require a user to
acknowledge them will have a button to the right titled ACK. Clicking the ACK button
changes the button text to Wait and sends a request to the meter to clear the alarm. The
alarm will disappear from the Check Status dialog once the alarm actually clears.
Click the Check Status button and Daniel MeterLink
opens the Status Summary dialog
box that gives a short description of all alarms present.
Figure 2-3: Status Summary
A. Active alarm conditions from Meter Monitor page
B. Status summary page with alarm examples
Following is a list and a brief description of the types of alarms:
System
Power Loss
Field I/O
Validity
Comms
Check Status
2.1.2
System alarm
The System alarm indicates a failure in the hardware that should be addressed by a service
technician. This includes memory checksum errors and communication errors within the
hardware. A Red LED indicates a system alarm condition. Collect a Maintenance log and an
audit/alarm log and then, contact your Daniel service representative. This could be an
alarm condition that occurred and remains latched until the condition is resolved and the
alarm is cleared by clicking the ACK button on the Monitor Check Status Status
Summary page.
Troubleshooting Maintenance and Troubleshooting manual
February 2020 P/N 3-9000-791
20 Models 3415, 3416 and 3417 GUSM
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102

Daniel 3410 Series Gas Ultrasonic Flow Meters Owner's manual

Type
Owner's manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI