Dometic Duo Therm 3108425.004 Hard Start Kit_AC Installation guide

Type
Installation guide
BLK
RED
BLK
BLK
WHT
RED
G/Y
MOTOR
FAN
BRN
WHT
COMPRESSOR
RS
C
RED
WHT
REVERSING VALVE
BLK
USE COPPER CONDUCTORS ONLY
115 VAC 60 HZ. 10
FIELD WIRING
FACTORY WIRING
LINE SPLICE
TO LOW VOLT THERMOSTAT CABLE
RED
RELAY
BLK
BLK
WHT
BLK
WHTBLK
WHT
HERM
C
FAN
NO
COMP
COM
TB8
TB7
AC WHITE
FAN
LOW
HIGH
FAN
RC
H
G
Y
WHT
RELAY BOARD
YEL
RUN CAP
YEL
BLU
BLU
BLK
BLK
VIO
JUNCTION
BOX
G/Y
VIO
ORN
RED
2
1
5
3
4
BLK
ORN
RED
START
CAP
1
2
5
RED
WHT
BLU
BLU
WHT
START
RELAY
RED
WHT
3108429.006
WHT
OL
3108425.004 HARD START KIT
for Model 41001.602
The Hard Start Kit will allow the compressor to start properly when operated with an Onan 2.8 Micro-Lite
Generator as the 120 volt power source.
High ambient temperatures can affect the ability of the air conditioner to start on generator power.
GENERAL INSTRUCTIONS
All field wiring modifications should be made in compliance with all National, State and Local Codes.
This Hard Start Kit should be installed only by a qualified serviceman who is familiar with air condition-
ers and electrical wiring.
Read and understand these instructions BEFORE attempting to install the Hard Start Kit. Keep these instruc-
tions with the air conditioner manuals.
INSTALLATION INSTRUCTIONS
1. Disconnect the 115 volt AC power to the air condi-
tioner.
2. The hard start kit must be mounted within 15" of
the unit electrical box, and with the arrow point-
ing up.
3. Remove cover from electrical box.
4. Remove the PTCR start device form the run capacitor
“Herm” terminal.
5. Remove the PTCR white wire from the “C” terminal. Dis-
card the PTCR.
6. Locate the red wire from the hard start kit. Route to
the run capacitor “Herm” terminal.
7. Locate the white wire from the hard start kit. Route to
the “AC White” terminal on the main board. Remove
the white wire currently on the “AC White” terminal, place
the white wire removed on the piggy back tab. Place
both wires on the terminal.
8. Locate the blue wire from the kit. Route to the relay #2
terminal. This terminal will have two black wires. Add
the blue wire to the terminal with the two black wires.
9. Recheck wiring for correctness and replace cover on
electrical box. Stick new wiring diagram 3108429.006
over old wiring diagram.
10. Install electrical box cover.
11. Turn on the 115 volt AC power supply and check the
operation per the Owner/Operator’s Manual.
WIRING DIAGRAM for 41001.602
REVISION
Form No. 3108428.024 4/01
(Replaces 3108428.016)
(French 3109120.018)
©2001 The Dometic Corporation
LaGrange, IN 46761
TAN
WHT
TO LOW VOLT
TO LOW VOLT
RED/
WHT T3
IF USED
IF USED
TO FURNACE
TO FURNACE
COM
BLU/
WHT
RED
K5
BLK
NO
CON 3
CON 3
FUSE
GRN
BLU
ORN YEL T4
COM
K4
CON 2
CON 2
NO
T2
CON 1
CON 1
T1
RED
BLK
TO 12 VOLT POWER
TO 12 VOLT POWER
BLK
SUPPLY
BLK VALVE
REV
TO 115 VAC
TO 115 VAC
WHT
G/Y
WHT
HERM
BLK
WHT
C
RUN CAP
RUN CAP
FAN
CONTROL
COLD
312
BRN
MOTOR
FAN
RED
BLK
COMPRESSOR
R
C
S
OL
G/Y
WHT
BLU
2
START
CAP
5
RELAY
START
1
WHT
RED
BLU/
WHT
WHT
THERMOSTAT CABLE
1O 60 Hz.
1O 60 Hz.
USE COPPER CONDUCTORS ONLY
USE COPPER CONDUCTORS ONLY
3108429.014
FOR MODEL: 41001.611
FOR MODEL: 41001.611
+
-
3108425.004 HARD START KIT
for Model 41001.611
The Hard Start Kit will allow the compressor to start properly when operated with an Onan 2.8 Micro-Lite
Generator as the 120 volt power source.
High ambient temperatures can affect the ability of the air conditioner to start on generator power.
GENERAL INSTRUCTIONS
All field wiring modifications should be made in compliance with all National, State and Local Codes.
This Hard Start Kit should be installed only by a qualified serviceman who is familiar with air condition-
ers and electrical wiring.
Read and understand these instructions BEFORE attempting to install the Hard Start Kit. Keep these instruc-
tions with the air conditioner manuals.
INSTALLATION INSTRUCTIONS
7. Locate the blue wire from the kit. Route to the K4 relay
“NO” terminal. This terminal will have one black wire
from the compressor. Add the blue wire to the “NO” ter-
minal with the black wire.
8. Recheck wiring for correctness and replace cover on
the electrical box. Stick new wiring diagram
3108429.014 over old wiring diagram.
9. Install electrical box cover.
10. Turn on the 115 volt AC power supply and check the
operation per the Owner/Operator’s Manual.
2
1. Disconnect the 115 volt AC power to the air condi-
tioner.
2. The hard start kit must be mounted within 15" of
the unit electrical box, and with the arrow point-
ing up.
3. Remove cover from electrical box.
4. Remove the PTCR start device form the run capacitor
“Herm” terminal.
5. Locate the red wire from the hard start kit. Route to
the run capacitor “Herm” terminal.
6. Remove the white wire from the PTCR off the “C” termi-
nal on the fan/run capacitor. Discard PTCR. Connect
the white wire from the hard start kit to the “C” terminal
of the fan/run capacitor.
WIRING DIAGRAM for 41001.611