GE JSP26BWWH Installation guide

Type
Installation guide
INSTALLATION INSTRUCTIONS FOR YOUR NEW
30" ELECTRIC SLIDE-IN RANGE
Before you begin - Read these instructions completely and carefully.
IMPORTANT - Save these instructions for local inspector’s use.
IMPORTANT - OBSERVE ALL GOVERNING CODES AND ORDINANCES.
Note to Installer - Be sure to leave these instructions with the Consumer.
Note to Consumer - Keep these instructions with your Use and Care Book for
future reference.
NOTE: This appliance must be properly grounded.
All Ranges Can Tip
Injury To Persons Could
Result
Install Anti-tip Device Packed
With Range
See Installation Instructions
WARNING
FOR YOUR SAFETY
1
CAUTION: For Personal
Safety remove house fuse or
open circuit breaker before
beginning installation. Failure
to do so could result in
serious injury or even death.
All rough-in and spacing dimensions must be
met for safe use of your range. Electricity to the
range can be disconnected at the outlet without
moving the range if the outlet is in the preferred
location (remove lower drawer).
To reduce the risk of burns or fire when reaching
over hot surface elements, cabinet storage
space above the cooktop should be avoided. If
cabinet storage space is to be provided above
the cooktop, the risk can be reduced by installing
a range hood that sticks out at least 5" beyond
the front of the cabinets. Cabinets installed
above a cooktop may be no deeper than 13".
Be sure your appliance is properly installed and
grounded by a qualified technician.
WARNING: To reduce the risk
of tipping the appliance, the
appliance must be secured by
properly installed anti-tip device
packed with the appliance.
INSTALLATION OF THE
ANTI–TIP DEVICE
Before placing range in the counter, check the
factory location of the stability device on the
back of the range. For convenience you can
hook the stability chain in the upper set of
holes. Make sure there is no structural
interference when using the upper set of holes.
Remove all parts from the plastic bag found
inside the prepack of the oven and save
packaging tape.
STABILITY DEVICE
Fig. 1
INT303-6
Pub No. 31-10070
1. Decide on a location
that has no electrical
wiring or plumbing.
2. With the long screw
provided anchor the
chain to the floor or
wall.
3. Make sure the screw
is going into the wall
plate or stud at the
base of the wall at
least 3/4".
4. Attach the stability
chain so that it lines
up with the bracket on the back of the range.
5. Tug the chain to make sure it is securely
fastened.
6. Take the packaging tape
and temporarily attach
the loose end of the chain
to the rear of the
countertop.
7. Slide the range into the
counter leaving enough
space behind to attach
the chain to the bracket.
8. Slip the nearest
link of the chain
onto the bracket.
Pull to make sure it
is as snug as
possible.
9. Slide the range all
the way back. It is
normal to have
some slack in the
chain, but it should
not be excessive.
The distance from the floor to the top of the
counter must be at least 35 7/8". The
maximum counter height is 38".
30" ranges conform to U.L. requirements for
0" spacing from vertical walls above
countertops. However, some kitchen cabinet
finishes can be damaged by heat from the
range surface elements. Where varnished
wood or plastic film finishes are used, a
minimum clearance of 6" must be maintained.
For listed over-the-range microwave ovens,
the microwave ovens can be installed above
the cooktop as per manufacturer's installation
instructions.
The range may be placed with 0" clearance
(flush) at the back wall and side walls if the
range side trims extend beyond the cabinet
fronts at least 1/4".
See Figures 1 and 2 for all rough-in and
spacing dimensions. These dimensions must
be met for safe use of your range. The
location of the electrical outlet may be
changed as needed, but electricity to the
range can be disconnected at the outlet
without moving the range if the outlet is in the
suggested location (remove lower drawer).
2
18" MIN
30" MIN
6"
MIN
0"
0"
TAPE
MINIMUM CLEARANCES
TOOL LIST
Hand or electric drill
Hand or saber saw
Pencil
Tape measure
Straightedge
1/8" drill bit
Fig. 6
MINIMUM DIMENSIONS BETWEEN COOKTOP
AND CABINETS OR WALLS
3
PREPARING THE COUNTER
FIG. 7
The distance from the floor to the top of the
counter must be at least 35 7/8". The
maximum countertop height is 38".
Make sure the wall coverings, countertop and
cabinets around the cooktop can withstand the
heat (up to 200°F) generated by the range.
NOTE: Dimension for Wall to Front of Door
Handle (door closed).
*-28" FOR MODELS- JSP26, JSS26, JSC26,
JSS16, RS734, RS504
**- 28 1/2" FOR MODELS- JSP39, JSP38,
JSP31, JSP28,
RS744, RS622,
JS960, JSP40,
JSP34
REMOVING PACKAGING
MATERIAL
Any packaging materials must
be removed during installation.
This will include adhesive tape, wire ties,
cardboard and protective plastic. Failure
to remove these materials could result in
damage to the appliance once the
appliance has been turned on and
surfaces have heated.
Remove all tape and packaging. Be sure to
remove clear plastic film that covers some
chrome parts (around glass oven doors, side
trim) and any tape and packaging from inside
the oven.
Take the accessory pack out of the oven.
Check to be sure that no range parts have
come loose during shipping.
PREPARATION
If you have an existing 30" wide cutout that goes
all the way to the wall, you have the option to buy
a 4" Backguard, Model #JXS31 (white), JXS32
(chrome), JXS33 (almond), JXS34 (black), or
JXS35 (bisque) or a Main Top Rear Filler Kit,
Model # JXS62BB (black), JXS63WW (white),
JXS64AA (almond), or JXS65CC (bisque).
These kits are available through your GE dealer,
if the existing cutout is in a counter that has a
backsplash (postformed top) we recommend that
you use the 4" backguard kit.
FIG. 8
Determine the dimension of your cutout. See
Fig. 9 and Fig. 10. Dimensions given are from
front of counter and not from cabinet face. To
minimize chipping you may want to apply
masking tape to the counter and mark the cut on
top of the tape. Use a hand or saber saw to
make the cut. For best appearance it is
important that the cut be smooth and straight.
If you are NOT using the Filler or Backguard:
If you have a countertop deeper than 25" and
you wish to set the range further back into the
counter, the cutout may be cut deeper (up to 24
1/2"), but there must be at least 24 1/2" from the
front edge of the countertop and back wall.
FIG. 9
23 3/16"
30"
4
30"
25"
If you are using the Filler or Backguard:
NOTE: If the distance from the back wall to the
front of the counter backsplash (Dimension A in
Fig. 11) is greater than the standard 1 1/8", there
will be a small gap between the wall behind the
range and the backguard. This is normal and
should not be visually objectionable.
Fig.10
FIG. 11
SIDE TRIM EXTENSION KIT
If there is a small gap between the sides of the
range and the cabinets (up to 1/4" each side),
you can order a side trim extension kit,
Pub, #3-A040, through the GE service center.
We recommend that you have the electrical
hookup of your range done by a qualified
electrician. Have the electrician show you
where your range disconnect is located.
Call your Electric Company and ask which
codes apply in your area. If there are no codes,
you must follow the NATIONAL ELECTRICAL
CODE, ANSI/NFPA NO. 70-Latest Edition.You
can get a copy by writing:
National Fire Protection Association
Battermarch Park
Quincy, MA 02269
Effective January 1, 1996, the National Electrical
Code requires that new or rewired construction
utilize a 4 conductor connection to an electric
range. When installing an electric range in a
new construction, follow the instructions in NEW
CONSTRUCTION AND FOUR-CONDUCTOR
BRANCH CIRCUIT CONNECTION.
If you fail to wire your range in accordance with
governing codes, you may create a hazardous
condition.
You must use a three-wire, single-phase AC
120/240 Volt or 208Y/120 Volt, 60 Hertz
electrical system to operate your range.
Use #8 wire and 40 Amp fuse or circuit breaker
for 120/240 Volt and 208Y/120 Volt systems.
The range connector block is approved for
copper wire connection only. If you are
connecting to aluminum house wiring, you must
use a special U.L. approved connector for
joining copper to aluminum.
ELECTRICAL CONNECTION
Remove the junction block access cover (on
range back). See Fig. 12A or 12B. SOME
MODELS will have a one-piece wire cover
shown in Fig.12B. When re-installing one-piece
wire cover, make sure that wire does not
become pinched between wire cover and
mainback.
5
Fig.12A
Fig.12B
TO MAKE ELECTRICAL
CONNECTION
All new constructions, mobile homes and
installations where local codes do not allow
grounding through neutral, require a four-wire
flexible cord kit. If the range is rated between
8,750 and 16,500 watts, the cord kit must be
rated for 40 Amps-125/250 volts. If the range is
rated between 16,501 and 22,500 watts, the
cord kit must be rated for 50 Amps-125/250
volts. For existing construction, a three wire
flexible cord kit may be used, and the same
ratings apply as described above.
When using a cord rated 40 Amps, remove the
next to outermost knockout (1 3/8" diameter) in
the connection plate. Likewise, when using a
cord rated 50 Amps, remove the outermost
knockout (1 3/4" diameter) in the plate.
Terminations shall be either closed loop
terminals or open-end spade lugs with
upturned ends. You must use a clamp or
strain relief to hold the cord.
NEW CONSTRUCTION AND
FOUR-WIRE CORD CONNECTION
Remove the screws on the terminal block.
Remove the ground screw, then remove the
ground strap.
Install the four-wire cord and strain relief in the
hole in the strain relief bracket.
Attach the green lead below the junction block
with the ground screw that was removed earlier
Connect the red and black lead to the outside
terminals and the white lead to the center
terminal.
Push the strain relief upward (to relieve
strain), while tightening the strain relief clamp.
Re-install the junction block access cover
making sure that wire does not become
pinched between wire cover and mainback.
Fig. 13
Remove the screws on the terminal block.
Install the three-wire cord and the strain relief
in the hole in the strain relief bracket.
Connect the outer leads to the outer terminals
and the center lead to the center terminal.
Push the cord upward, (to relieve strain), while
tightening the strain relief clamp.
If local codes require an ungrounded neutral:
a. Remove ground strap.
b. Fasten the white wire to the center terminal.
c. Use grounding terminal or lead to ground unit
in accordance with local codes.
Re-install the wire cover making sure that the
wire does not become pinched between wire
cover and mainback.
THREE-WIRE CORD CONNECTION
Fig. 14
OVEN DOOR REMOVAL
Before installing the range, you may remove the
oven door to lessen the weight of the unit. DO
NOT lift unit by door handle.
To remove oven door:
1. Open the door to the stop position. See
Fig. 15A.
2. Grasp the door at each side and lift up and off
the hinges. See Fig. 15B.
6
Fig. 15A
Fig. 15B
CAUTION: When the door is
removed and hinge arms are at
stop position, do not bump or
try to move the hinge arms.
The hinges could snap back
causing an injury to the hands or dam-
age to the porcelain on the front of the
oven. Cover the hinges with toweling or
insert empty towel rolls behind the
hinges while working in the oven area.
For proper cooking and baking the range must
be leveled. Do not place range in cutout until
you are sure that the flanges below the sides of
the cooktop are above the top of the counter.
Lift cooktop to see flanges. Damage to the
cooktop could result if adjusted improperly.
a. Install the oven racks (see use and care
section for instructions).
b. Use a 1 3/8" open end wrench or an
adjustable wrench to equally back out
the four leg levelers until the flanges
(rims) below the sides of the maintop are
above the top of the counter. Check by
measuring the height of the counter and
comparing it with the measurement from
the floor to the flanges below the sides of
the cooktop. Place range in cutout when
adjustments are complete.
Fig. 16
c. Put a spirit level or a glass measuring
cup partially filled with water on one of
the oven racks. See Fig. 17.
d. Use the wrench to adjust the leg levelers.
Level range front to back and side to
side. See Fig. 16.
Fig. 17
LEVELING THE RANGE
IMPORTANT INSTALLATION INSTRUCTIONS FOR
RANGES USED WITH COUNTERTOP HEIGHTS UP TO 38"
7
The height of the range must be adjusted to the
countertop height. For countertop heights
greater than 37", additional measurements may
need to be taken as detailed below.
When the range is elevated to the maximum
height, there is a large space between the
bottom of the range and the floor, referred to as
the toe space. This may be visually
objectionable. The legs should not be extended
any further than to provide a maximum of 3" toe
space. See Fig. 18.
The range is designed to provide a minimum of
1" air gap at the bottom of the range. See Fig.
19. (Example: When legs are screwed all the
way into the base rail.)
Build the filler as shown in Fig.19. Make sure to
provide the 3/4" gap at the top and the 5/16" gap
at the bottom. These gaps will provide the
proper ventilation as mentioned before.
If you wish to attach the filler to the floor or
adjacent cabinets, use screws or other
removable fasteners, so that the range can be
readily removed if necessary.
Fig. 20
3" MAX. HEIGHT
This gap is very important to the proper
ventilation of the range and must be maintained
when treating the appearance of the toe space.
The following is a suggested method of making a
filler for the toe space when the legs are
extended as mentioned before.
After the range is installed with the longer legs
and is in position and level, measure from the
bottom of the bodyside to the floor. This will be
the required height of the toe space filler. See
Fig. 19. This height may range from 2 1/16" to
3". Any height less than 2 1/16" may not be
visually objectionable and not need the filler.
1" MIN. HEIGHT
Fig. 19
Fig. 18
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

GE JSP26BWWH Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI