Mammoth R6GP 6, 7.5 - 10 Ton Archived 2/23/12 Product information

Category
Camera cables
Type
Product information

This manual is also suitable for

SEE
NOTE 4
SEE
NOTE 3
SEE
NOTE 3
SEE NOTE 1
SEE
NOTE 4
INDOOR
BLOWER
RELAY
123 5467810911121314 15
123 546781091112131514
WH
MAX TEMP
LIMIT
LOWER
SECONDARY
LIMIT
FLAME
ROLLOUT
SWITCH
3 MIN TDR
31
BK
INDUCER
MOTOR
GAS VALVE
BLOWER
TIME-DELAY
3
2
1
4
36
9
B
A
4
7
1
AUTOTRANSFORMER
(460 AND 575 MODELS
ONLY)
SEE
NOTE 2
L2
L3
BK
BK
230V
OR
ECONOMIZER
PLUG
FACTORY JUMPER PLUG
(REMOVE FOR ECONOMIZER OPERATION-
SEE ECONOMIZER INSTALLATION INST. FOR DETAILS)
YELLOW
BROWN
LOW VOLTAGE
CONNECTIONS
C1
HV
C2GV2
GV1
BLOWER
RELAY
CONTROL WIRING LEADS
REFER TO INSTALLATION INSTRUCTIONS
FOR CONNECTION TO INDOOR THERMOSTAT
TYP. INDOOR
THERMOSTAT
TERMINALS
R
Y1
Y2
W2
W1
G
W2
C
W1
R
Y2
G
Y1
PRI.
SEC.
24V
TRANSFORMER
GND
TO FIELD SUPPLIED
DISCONNECT
(3 PHASE POWER ONLY)
FLAME
SENSOR
IGNITOR
GND V2 or COM
V1 or MVS1 or FSTH or W
IGNITION CONTROL
GND
OUTDOOR
FAN
RELAY
1ST
STAGE
COMP.
RELAY
H.P. SWITCH
L.P. SWITCH
H.P. SWITCH
L.P. SWITCH
STG. 2 EVAP
FRE-STAT
STG. 1 EVAP
FRE-STAT
BL
BR BR BR BR
BR BR
BR BR
BK
BK
YE
BR
BR
YE
BK
BR
BR
YE
BK
C
RS
C
RS
T1
T3
T2
T1
T3
T2
T2
T1
T3
L2 L1
T2 T1
L2 L1
T2 T1
L3
T3
L2 L1
T2 T1
L3
T3
L2 L1
T2 T1
L3
T3
CCH2
CCH1
2ND
STAGE
COMP.
RELAY
BLOWER
LIMIT-RELAY
3
1
6
5
4
2
42
6
5
3
1
L1
L2
L3
BK
BK
BK
BK
BK
BK
INDUCER
MOTOR
RELAY
RED
BLACK
BLACK
WHITE
BROWN
WHITE
BLACK
WHITE
BLACK
BROWN
WHITE
RED
BLACK
ORANGE
GREY
OR
OR
BROWN
RED
RED
RED
BLACK
GREY
BLACK
BROWN
YELLOW
RED
BLACK
BLACK
YELLOW
BLACK
RED
BLACK
BLACK
YE/BK STRIPE
RED
BLACK
RED
YELLOW
BLACK
ORANGE
BLACK
ORANGE
RED
ORANGE
BLACK
RD/BK STRIPE
BLACK
RED
RED
BLUE
ORANGE
YELLOW
BLACK
BLACK
RED
BLACK
GREY
GN/YE
ORANGE
GREY
GREY
YE/BK STRIPE
RD/BK STRIPE
BK/WH STRIPE
BK/WH STRIPE
ORANGE
ORANGE
RED
YELLOW
GN/YE
7107510
02/08
FIELD WIRING
LEGEND:
LOW VOLTAGE
HIGH VOLTAGE
NOTES:
208-230/460/575 VOLTR6GP-090(C/D) SERIES THREE PHASE / 60 Hz
1. This wire replaced by autotransformer when used.
2. For 090C models only. For 208 VAC operation remove wire at
240V tap and place on 208V tap.
3. Wires attached to normally open contacts of auxillary switch.
4. Wires attached to normally closed contacts of auxillary switch.
5. Disconnect all power before servicing.
6. For supply connections use copper conductors only.
7. If any of the original wire as supplied with the furnace must be
replaced, it must be replaced with wiring material having a
temperature rating of at least 105C.
8. For supply wire ampacities and overcurrent protection, see unit
rating label.
WIRING DIAGRAM
¢710751§¤
  • Page 1 1