To adjust the internal temperature
(if necessary):
Turn the thermostat control knob (1):
- Towards position 1 for less cold internal
temperatures.
- Towards position 3 for colder
temperatures.
- To position to use the fast freeze
function.
Recommended thermostat setting: 2-3.
How to freeze fresh food
1. 24 hours before freezing fresh food, turn the knob (1) to position
; When turning from 3 to pos. , the knob is slightly stiff and
the yellow indicator (3) near the symbol lights up.
2. Place food in the drawer, leaving enough space for air to circulate
around packs.
3. For more efficient freezing, turn the knob (2) to position 7.
4. Leave the fast freeze function activated for the next 24 hours
5. When freezing is complete, turn both knobs (1), (2) back to their
recommended positions.
CONTROL PANEL DESCRIPTION
On/Off buttons
1. Alarm resetting button.
2. Alarm indicator lamp.
3. Function selection button.
4. Party Mode function indicator lamp.
5. Fast Cooling function indicator lamp.
6. Anti-bacterial filter replacement indicator lamp.
7. Anti-bacterial filter alarm resetting button.
FUNCTION DESCRIPTION
Functions and settings
Other abnormal appliance operations
In case of abnormal appliance operation, a red alarm light will flash
and a beep will sound.
After pressing and holding the alarm deactivation “RESET” button,
the beep will stop and the indicator lamps (Party Mode, Fast Cooling,
Antibacterial Filter) will light up, allowing the user to determine the
alarm code (in accordance with the following table listing possible
alarm codes).
When several alarms occur simultaneously, the alarm with the highest
priority is displayed (the highest priority is alarm code 01).
When the “RESET” button is released, the red indicator lamp will
flash until the fault is eliminated.
If the sensor failure alarm is displayed (alarm code 01), the Party
Mode function is available until the fault is rectified. If the
potentiometer failure alarm is displayed (alarm code 02), the Party
Mode and Fast Cooling functions are available.
After determining the alarm code (from 01 to 03), the user:
• Can eliminate the reason of the code 03 alarm unaided by closing
the door.
• The other alarms (codes 01, 02) require contacting the
service and providing the alarm code.
REPLACING THE LIGHT BULB
Always disconnect the refrigerator from the power supply before
replacing any light bulb. If the inside light is not working, it is necessary
to:
1. Remove the light cover: put the fingers into the side ventilation
holes (1), stretch the cover gently and move it upwards.
2. Remove the bulb pulling it out of the holder (do not rotate).
3. Check the bulb and replace (if necessary) by pushing its terminals
into the holder sockets until it stops.
4. Replace the light cover or holder.
The appliance is equipped with a special push-in light bulb.
This bulb is available only from our After-Sales Service.
The bulb should not exceed 15W.
Do not leave uncovered the bulb.
Care and Maintenance
When cleaning, especially with the light cover removed, take
special safety precautions and do not touch the light bulb.
Alarm resetting (deactivation)
Party Mode: Activate this function before cooling
products in the freezer compartment. To activate this
function, press button Party Mode/Fast Cooling - 1
green LED lights up on the panel. After 30 minutes, the
LED will flash and a beep is heard. To reset the alarm press
button Party Mode/Fast Cooling - the green LED goes
off.
Fast cooling: Activate this function before cooling fresh
products in the refrigerator compartment. To activate this
function, press and hold for 3 seconds the Party Mode/
Fast Cooling button - green LED 2 lights up on the panel.
This function turns off automatically after 6 hours. To
deactivate this function earlier, press and hold for 3
seconds the Party Mode/Fast Cooling button - green
LED 2 goes off.
“Anti-Bacterial filter”- The antibacterial filter assures
maintaining a higher level of hygiene in the refrigerator by
continuously purifying the circulating air of bacteria. When
it is necessary to replace the filter, a yellow LED (6) lights
up. After replacing the filter, press and hold for 3 seconds
the Reset filter button (7) to deactivate the alarm.
Alarm type
Alarm
codes
Indicator Lamp on
Party
Mode
Fast
cooling
AntiBacterial
filter
Air sensor failure 01 NO NO YES
Potentiometer failure 02 NO YES NO
Open door alarm 03 YES NO NO
5019 637 01041