1100 Old Honeycutt Road, Fuquay-Varina, NC 27526
(919) 762-1000 www.southbendnc.com
Models:
REAR VIEW
7" (178)
FRONT VIEW
16" (406)
37-1/2"
(953)
24"
(610)
60"
(1524)
41"
(1041)
72"
(1829)
5" Flue Riser
24" Flue Riser
36" Flue Riser
36"
(914)
TOP VIEW
20"
(508)
Rear Gas
Connection
SIDE VIEW
37-1/2" (953)
34" (864)
40" (1016)
43-1/2" (1105)
12-1/2"
(318)
33-3/4"
(857)
5" (127)
8-1/2" (216)
SIDE VIEW of MODULAR MODEL
Front Gas
Manifold
9-1/4"
(235)
Optional extra-deep flue riser (cooking area is
same as for models with standard flue riser).
P16N-C P16C-C
INTENDED FOR COMMERCIAL USE ONLY.
NOT FOR HOUSEHOLD USE.
OPTIONS and ACCESSORIES
MISCELLANEOUS
UTILITY INFORMATION
GAS:Eachunithasa1-1/4"frontmanifoldthatcouplestothe
adjacentsectionalunit(s),anda1"reargasconnectionwithamale
NPTconnector.Minimumgassupplypressureis7"W.C.fornatural
gasand11"W.C.forpropane.Allsectionalunitsrequirearegulated
gassupply(apressureregulatormustbeorderedseparately).If
usingaexible-hosegasconnection,theinsidediameterofthehose
mustnotbesmallerthantheconnectorontheunitandmustcomply
withANSIZ21.69,providinganadequatemeansofrestraintto
preventunduestrainonthegasconnection.
• Ifcastersareusedwithaexible-hosegasconnection,a
restrainingdeviceshouldbeusedtopreventunduestrain
onthehose.
• Minimumclearancefromnoncombustibleconstructionis
zero.Installationnexttocombustibleconstructionisnot
recommended.
• Installationunderaventedhoodisrecommended.
• Checklocalcodesforreandsanitaryregulations.
NOTICE:
Southbendhasapolicyofcontinuousproductresearchand
improvement.Wereservetherighttochangespecicationsand
productdesignwithoutnotice.Suchrevisionsdonotentitlethebuyer
tocorrespondingchanges,improvements,additionsorreplacements
forpreviouslypurchasedequipment.
Externalpressureregulator
Frontrailoptions:
Cutoutsinfrontrailforsaucepans
7-1/4"deepfrontrail(tomatchold
stylesectional)
Squarebellybarmountedon7-1/4"
deepfrontrail
Casters(fronttwocasterslock)
Cablerestraintkit(torestrict
movementwhenoncasters)
24"or36"highueriser
Open-framebasewithcastersfor
battery
FormP16-CRev3(September/2009)
Dimensionsshownininchesand(millimeters)
Extra-deeprear-extendingueriser
Removableshelfinsidecabinet
Platedshgrids
Model
Gas (BTU/hoUr)
NaTUral ProPaNe
P16N-C 40,000 36,000
P16C-C 40,000 36,000
shiPPiNG CraTe diMeNsioNs & WeiGhT
Model WidTh heiGhT dePTh VolUMe WeiGhT
P16N-C
20"
(508)
21"
(533)
42.5"
(1080)
10.3 cu ft
(0.29 cu m)
240 lbs
(108.9 kg)
P16C-C
20"
(508)
45"
(1143)
42.5"
(1080)
22.1 cu ft
(0.63 cu m)
270 lbs
(122.5 kg)