4
To unpair the selected load(s)
• Tap the remote button 3 times to unpair the remote button from the switch.
• The load(s) will temporarily turn OFF and ON confirming the message was received.
• The green LED on the switch will stop flashing and exit pairing mode.
• The remote button should no longer control the load(s).
• Repeat steps above to unpair another button.
TO “UNPAIR” ALL CONNECTED DEVICES
Press and hold the Wall Switch Pairing button “P” for about 10 seconds, until all LEDs on the units start flashing all together.
TROUBLESHOOTING
Does the system work more reliably at close range (without obstructions)?
In an indoor environment, the wireless controls have a typical range of 30-150 feet. If there are obstructions and/or noise interference
the range will be less than the typical range.
Consider Factors Affecting the Environment:
The range can be reduced by metal objects (metal decreases the effectiveness of RF transmission). Switches also go into a reduced
range mode when in programming (under 15 feet)
• Identify nearby metal, concrete and other objects possibly affecting signal strength
• If possible, try relocating the device (even slightly) away from obstructions to improve the system performance.
Consider Factors Affecting the Environment:
• Device placement
• Obstructions (metal, concrete, other construction materials)
• Interference
Does the system work better at certain times of the day?
• Look for pieces of equipment that may affect wireless performance when they are ON
• Noise interference can be either line noise (from motors) or Radio Frequency (RF)
Product Performance:
• To isolate any variation in product performance replace one piece of hardware at a time
Load does not turn ON or OFF:
• If load does not shut off automatically, enter configuration mode to check settings for the load (if in manual mode switch to auto
mode). If you cannot switch then sensor is not paired to load.
• If load does not turn on/off from remote switch, check pairing of the switch to the load. (See pairing devices.)
CONTAINS FCC ID: SZV-PTM210U and IC: 5713A-PTM210U
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference
that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated
in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used
in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in
a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own
expense.